메뉴 건너뛰기




Volumn 48, Issue 11, 2012, Pages 2838-2841

Characterization of magnetic markers and sensors for liquid-phase immunoassays using brownian relaxation

Author keywords

Bio nanotechnology; biosensors; Brownian relaxation; magnetic sensors; nanoparticles

Indexed keywords

BIOLOGICAL TARGETS; BIONANOTECHNOLOGY; BROWNIAN RELAXATION; IMMUNOASSAY TECHNIQUES; KEY PARAMETERS; LIQUID PHASE; MAGNETIC MARKER; MAGNETIC NANOPARTICLES; NEEL RELAXATION; POLYMER BEADS; WASHING PROCESS;

EID: 84867795114     PISSN: 00189464     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMAG.2012.2194137     Document Type: Article
Times cited : (12)

References (13)
  • 1
    • 45849086137 scopus 로고    scopus 로고
    • Advances in giant magneto resistance biosensors with magnetic nanoparticle tags: Review and outlook
    • S. X. Wang and G. Li, "Advances in giant magneto resistance biosensors with magnetic nanoparticle tags: Review and outlook," IEEE Trans. Magn., vol. 44, pp. 1687-1702, 2008.
    • (2008) IEEE Trans. Magn. , vol.44 , pp. 1687-1702
    • Wang, S.X.1    Li, G.2
  • 2
    • 70350413464 scopus 로고    scopus 로고
    • Magnetic nanoparticle sensors
    • I. Koh and L. Josephson, "Magnetic nanoparticle sensors," Sensors, vol. 9, pp. 8130-8145, 2009.
    • (2009) Sensors , vol.9 , pp. 8130-8145
    • Koh, I.1    Josephson, L.2
  • 3
    • 79551612318 scopus 로고    scopus 로고
    • Detection of two different influenza A viruses using a nitrocellulose membrane and a magnetic biosensor
    • H. B. Hong, H. J. Krause, K. B. Song, C. J. Choi, M. A. Chung, S. W. Son, and A. Offenhausser, "Detection of two different influenza A viruses using a nitrocellulose membrane and a magnetic biosensor," J. Immunol. Meth., vol. 365, pp. 95-100, 2011.
    • (2011) J. Immunol. Meth. , vol.365 , pp. 95-100
    • Hong, H.B.1    Krause, H.J.2    Song, K.B.3    Choi, C.J.4    Chung, M.A.5    Son, S.W.6    Offenhausser, A.7
  • 4
    • 79955870892 scopus 로고    scopus 로고
    • Quantification of protein interactions and solution transport using high-density GMR sensor arrays
    • R. Gaster, L.Xu, S. J. Han, R. J. Wilson,D.A. Hall, S. J.Osterfeld, H. Yu, andS.X.Wang, "Quantification of protein interactions and solution transport using high-density GMR sensor arrays," Nat. Nanotechnol., vol. 6, pp. 314-320, 2011.
    • (2011) Nat. Nanotechnol. , vol.6 , pp. 314-320
    • Gaster, R.1    Xu, L.2    Han, S.J.3    Wilson, D.A.4    Hall, R.J.5    Osterfeld, J.S.6    Yu, H.7    Wang, S.X.8
  • 5
    • 0346458689 scopus 로고    scopus 로고
    • Determination of bacteria in suspension using a superconducting quantum interference device
    • H. Grossman, W. Myers, V. Vreeland, R. Bruehl, M. D. Alper, C. R. Bertozzi, and J. Clarke, "Determination of bacteria in suspension using a superconducting quantum interference device," PNAS U. S. A., vol. 101, pp. 129-134, 2004.
    • (2004) PNAS U. S. A. , vol.101 , pp. 129-134
    • Grossman, H.1    Myers, W.2    Vreeland, V.3    Bruehl, R.4    Alper, M.D.5    Bertozzi, C.R.6    Clarke, J.7
  • 8
    • 64249093264 scopus 로고    scopus 로고
    • Specific binding of magnetic nanoparticle probes to platelets in whole blood detected by magnetorelaxometry
    • D. Eberbeck, F.Wiekhorst,U. Steinhoff,K. O.Schwarz, A.Kummrow, M.Kammel, J. Neukammer, and L. Trahms, "Specific binding of magnetic nanoparticle probes to platelets in whole blood detected by magnetorelaxometry," J. Magn. Magn. Mater., vol. 321, pp. 1617-1620, 2009.
    • (2009) J. Magn. Magn. Mater. , vol.321 , pp. 1617-1620
    • Eberbeck, D.1    Wiekhorst, F.2    Steinhoff, U.3    Schwarz, K.O.4    Neukammer, J.5    Trahms, L.6
  • 9
    • 66149087318 scopus 로고    scopus 로고
    • Multiplex detection of DNA sequences using the volume-amplified magnetic nanobead detection assay
    • M. Stromberg, T. Torre, J. Goransson, K. Gunnarsson, M. Nilson, P. Svedlindh, and M. Stromme, "Multiplex detection of DNA sequences using the volume-amplified magnetic nanobead detection assay," Anal. Chem, vol. 81, pp. 3398-3406, 2009.
    • (2009) Anal. Chem , vol.81 , pp. 3398-3406
    • Stromberg, M.1    Torre, T.2    Goransson, J.3    Gunnarsson, K.4    Nilson, M.5    Svedlindh, P.6    Stromme, M.7
  • 10
    • 77955889159 scopus 로고    scopus 로고
    • AC susceptibility measurement of magnetic markers in suspension for liquid phase immunoassay
    • K. Enpuku, Y. Tamai, T. Mitake, T. Yoshida, andM.Matsuo, "AC susceptibility measurement of magnetic markers in suspension for liquid phase immunoassay," J. Appl. Phys., vol. 108, p. 034701, 2010.
    • (2010) J. Appl. Phys. , vol.108 , pp. 034701
    • Enpuku, K.1    Tamai, Y.2    Mitake, T.3    Yoshida, T.4    Matsuo, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.