메뉴 건너뛰기




Volumn 21, Issue 3 PART 1, 2011, Pages 477-480

Multi-channel squid-based ultra-high-sensitivity in-vitro detections for bio-markers of alzheimer's disease via immunomagnetic reduction

Author keywords

Alzheimer's disease; Immunoassay; Magnetic nanoparticles; SQUIDs

Indexed keywords

ALZHEIMER'S DISEASE; IMMUNOASSAY; IN-VITRO; MAGNETIC NANOPARTICLES; MAGNETIC SIGNALS; MULTI-CHANNEL; SINGLE CHANNELS; SQUID MAGNETOMETERS; SUPERCONDUCTING QUANTUM INTERFERENCE DEVICE; ULTRA-HIGH; ULTRA-HIGH-SENSITIVITY; WORKING PRINCIPLES;

EID: 79957958462     PISSN: 10518223     EISSN: None     Source Type: Journal    
DOI: 10.1109/TASC.2010.2087304     Document Type: Conference Paper
Times cited : (40)

References (17)
  • 2
    • 0034778586 scopus 로고    scopus 로고
    • Magnetoencephalography in the detection of focal lesions in West syndrome
    • DOI 10.1016/S0387-7604(01)00311-4, PII S0387760401003114
    • H. Hattori, T. Yamano, T. Tsutada, N. Tsuyuguchi, H. Kawawaki, and M. Shimogawar, "Magnetoencephalography in the detection of focal lesions in West syndrome," Brain and Development, vol. 23, pp. 528-532, Nov. 2001. (Pubitemid 32999120)
    • (2001) Brain and Development , vol.23 , Issue.7 , pp. 528-532
    • Hattori, H.1    Yamano, T.2    Tsutada, T.3    Tsuyuguchi, N.4    Kawawaki, H.5    Shimogawara, M.6
  • 4
    • 0032814236 scopus 로고    scopus 로고
    • Spatial distribution of QT dispersion measured by magnetocardiography under stress in coronary artery disease
    • DOI 10.1016/S0022-0736(99)90103-6
    • B. Hailer, P. Van Leeuwen, S. Lange, and M. Wehr, "Spatial distribution of QTdispersion measured by magnetocardiography munder stress in coronary artery disease," J. Electrocard., vol. 32, pp. 207-216, Jul. 1999. (Pubitemid 29380159)
    • (1999) Journal of Electrocardiology , vol.32 , Issue.3 , pp. 207-216
    • Hailer, B.1    Van Leeuwen, P.2    Lange, S.3    Wehr, M.4
  • 5
    • 84859543025 scopus 로고    scopus 로고
    • Measurements of the magnetocardiography in unshielded environment using high-Tc rf SQUID gradiometer
    • Nov
    • D. F. He, F. Zhang, F. X. Xie, Y. D. Dai, S. G. Wang, P. Ma, T. Yang, S. Z. Wang, W. C. Chen, and Z. Q. Wang, "Measurements of the magnetocardiography in unshielded environment using high-Tc rf SQUID gradiometer," Physica C, vol. 341-348, pp. 2635-2636, Nov. 2000.
    • (2000) Physica C , vol.341-348 , pp. 2635-2636
    • He, D.F.1    Zhang, F.2    Xie, F.X.3    Dai, Y.D.4    Wang, S.G.5    Ma, P.6    Yang, T.7    Wang, S.Z.8    Chen, W.C.9    Wang, Z.Q.10
  • 7
    • 0037749861 scopus 로고    scopus 로고
    • Determination of the binding reaction between avidin and biotin by relaxation measurements of magnetic nanoparticles
    • Nov
    • R. Kötitz, W. Weitschies, L. Trahms, W. Brewer, and W. J. Semmler, "Determination of the binding reaction between avidin and biotin by relaxation measurements of magnetic nanoparticles," Magn. Magn. Mater., vol. 194, pp. 62-68, Nov. 1999.
    • (1999) Magn. Magn. Mater. , vol.194 , pp. 62-68
    • Kötitz, R.1    Weitschies, W.2    Trahms, L.3    Brewer, W.4    Semmler, W.J.5
  • 11
    • 33745466335 scopus 로고    scopus 로고
    • Enhancement of nuclear magnetic resonance in microtesla magnetic field with prepolarization field detected with high- Tc superconducting quantum interference device
    • Jun
    • H.-C. Yang, S.-H. Liao, H.-E. Horng, S.-L. Kuo, H.-H. Chen, and S. Y. Yang, "Enhancement of nuclear magnetic resonance in microtesla magnetic field with prepolarization field detected with high- Tc superconducting quantum interference device," Appl. Phys. Lett., vol. 88, p. 252505, Jun. 2006.
    • (2006) Appl. Phys. Lett. , vol.88 , pp. 252505
    • Yang, H.-C.1    Liao, S.-H.2    Horng, H.-E.3    Kuo, S.-L.4    Chen, H.-H.5    Yang, S.Y.6
  • 13
    • 33747888030 scopus 로고    scopus 로고
    • Improvement of sensitivity of multisample biological immunoassay system using HTS SQUID and magnetic nanoparticles
    • DOI 10.1016/j.physc.2006.06.019, PII S0921453406006150, Proceedings on the 18th International Symposium on Superconductivity
    • A. Tsukamoto, K. Saitoh, N. Sugita, H.Kuma, Y. Sugiura, S. Hamaoka, N. Hamasaki, and K. Enpuku, "Improvement of sensitivity of multisample biological immunoassay system using HTS SQUID and magnetic nanoparticles," Physica C, vol. 445-448, pp. 975-978, Oct. 2006. (Pubitemid 44293340)
    • (2006) Physica C: Superconductivity and its Applications , vol.445-448 , Issue.1-2 , pp. 975-978
    • Tsukamoto, A.1    Saitoh, K.2    Sugita, N.3    Kuma, H.4    Sugiura, Y.5    Hamaoka, S.6    Hamasaki, N.7    Enpuku, K.8
  • 14
    • 12144287428 scopus 로고    scopus 로고
    • Magnetorelaxometry-A new binding specific detection method based on magnetic nanoparticles
    • Nov
    • J. Lange, R. Kötitz, A. Haller, L. Trahms, W. Semmler, and W. Weitschies, "Magnetorelaxometry-A new binding specific detection method based on magnetic nanoparticles," J. Magn. Magn. Mater., vol. 252, pp. 381-383, Nov. 2002.
    • (2002) J. Magn. Magn. Mater. , vol.252 , pp. 381-383
    • Lange, J.1    Kötitz, R.2    Haller, A.3    Trahms, L.4    Semmler, W.5    Weitschies, W.6
  • 16
    • 0035997222 scopus 로고    scopus 로고
    • β-amyloid (Aβ) protein in cerebrospinal fluid as a biomarker for Alzheimer's disease
    • Jul
    • N. Andreasen and K. Blennow, " β-Amyloid (Aβ) protein in cerebrospinal fluid as a biomarker for Alzheimer's disease," Peptides, vol. 23, pp. 1205-1211, Jul. 2002.
    • (2002) Peptides , vol.23 , pp. 1205-1211
    • Andreasen, N.1    Blennow, K.2
  • 17
    • 62449262536 scopus 로고    scopus 로고
    • Cerebrospinal fluid β-amyloid 42 and tau proteins as biomarkers of Alzheimer-type pathologic changes in the brain
    • Mar
    • T. Tapiola, I. Alafuzoff, S. K. Herukka, L. Parkkinen, P. Hartikainen, H. Soininen, and T. Pirttilä, "Cerebrospinal fluid β-amyloid 42 and tau proteins as biomarkers of Alzheimer-type pathologic changes in the brain," Arch. Neurol., vol. 66, pp. 382-389, Mar. 2009.
    • (2009) Arch. Neurol. , vol.66 , pp. 382-389
    • Tapiola, T.1    Alafuzoff, I.2    Herukka, S.K.3    Parkkinen, L.4    Hartikainen, P.5    Soininen, H.6    T. Pirttilä7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.