메뉴 건너뛰기




Volumn 14, Issue 1, 2012, Pages

Quantitative myocardial perfusion in mice based on the signal intensity of flow sensitized CMR

Author keywords

Arterial spin labeling; Mice; Myocardial perfusion; T1

Indexed keywords

ANIMAL EXPERIMENT; ARTICLE; CARDIOVASCULAR MAGNETIC RESONANCE; HEART MUSCLE PERFUSION; IN VIVO STUDY; MOUSE; NONHUMAN; PHANTOM; PRIORITY JOURNAL; QUALITATIVE ANALYSIS; QUANTITATIVE ANALYSIS; REPERFUSION INJURY;

EID: 84867685162     PISSN: 10976647     EISSN: 1532429X     Source Type: Journal    
DOI: 10.1186/1532-429X-14-73     Document Type: Article
Times cited : (11)

References (20)
  • 1
    • 0030032648 scopus 로고    scopus 로고
    • Magnetization exchange in capillaries by microcirculation affects diffusion-controlled spin-relaxation: A model which describes the effect of perfusion on relaxation enhancement by intravascular contrast agents
    • 10.1002/mrm.1910350107 8771021
    • Magnetization exchange in capillaries by microcirculation affects diffusion-controlled spin-relaxation: a model which describes the effect of perfusion on relaxation enhancement by intravascular contrast agents. Bauer WR, Hiller KH, Roder F, Rommel E, Ertl G, Haase A, Magn Reson Med 1996 35 1 43 55 10.1002/mrm.1910350107 8771021
    • (1996) Magn Reson Med , vol.35 , Issue.1 , pp. 43-55
    • Bauer, W.R.1    Hiller, K.H.2    Roder, F.3    Rommel, E.4    Ertl, G.5    Haase, A.6
  • 2
    • 64549100646 scopus 로고    scopus 로고
    • Resting myocardial perfusion quantification with CMR arterial spin labeling at 1.5 T and 3.0 T
    • 10.1186/1532-429X-10-53 19014709
    • Resting myocardial perfusion quantification with CMR arterial spin labeling at 1.5 T and 3.0 T. Northrup BE, McCommis KS, Zhang H, Ray S, Woodard PK, Gropler RJ, Zheng J, J Cardiovasc Magn Reson 2008 10 1 53 10.1186/1532-429X-10-53 19014709
    • (2008) J Cardiovasc Magn Reson , vol.10 , Issue.1 , pp. 53
    • Northrup, B.E.1    McCommis, K.S.2    Zhang, H.3    Ray, S.4    Woodard, P.K.5    Gropler, R.J.6    Zheng, J.7
  • 3
    • 0242268580 scopus 로고    scopus 로고
    • Quantitative assessment of myocardial perfusion with a spin-labeling technique: Preliminary results in patients with coronary artery disease
    • 10.1002/jmri.10386 14579398
    • Quantitative assessment of myocardial perfusion with a spin-labeling technique: preliminary results in patients with coronary artery disease. Wacker CM, Fidler F, Dueren C, Hirn S, Jakob PM, Ertl G, Haase A, Bauer WR, J Magn Reson Imaging 2003 18 5 555 560 10.1002/jmri.10386 14579398
    • (2003) J Magn Reson Imaging , vol.18 , Issue.5 , pp. 555-560
    • Wacker, C.M.1    Fidler, F.2    Dueren, C.3    Hirn, S.4    Jakob, P.M.5    Ertl, G.6    Haase, A.7    Bauer, W.R.8
  • 4
    • 0031727183 scopus 로고    scopus 로고
    • In vivo quantitative mapping of cardiac perfusion in rats using a noninvasive MR spin-labeling method
    • 10.1002/jmri.1880080610 9848735
    • In vivo quantitative mapping of cardiac perfusion in rats using a noninvasive MR spin-labeling method. Belle V, Kahler E, Waller C, Rommel E, Voll S, Hiller KH, Bauer WR, Haase A, J Magn Reson Imaging 1998 8 6 1240 1245 10.1002/jmri.1880080610 9848735
    • (1998) J Magn Reson Imaging , vol.8 , Issue.6 , pp. 1240-1245
    • Belle, V.1    Kahler, E.2    Waller, C.3    Rommel, E.4    Voll, S.5    Hiller, K.H.6    Bauer, W.R.7    Haase, A.8
  • 5
    • 0345742637 scopus 로고    scopus 로고
    • High-resolution myocardial perfusion mapping in small animals in vivo by spin-labeling gradient-echo imaging
    • 10.1002/mrm.10676 14705046
    • High-resolution myocardial perfusion mapping in small animals in vivo by spin-labeling gradient-echo imaging. Kober F, Iltis I, Izquierdo M, Desrois M, Ibarrola D, Cozzone PJ, Bernard M, Magn Reson Med 2004 51 1 62 67 10.1002/mrm.10676 14705046
    • (2004) Magn Reson Med , vol.51 , Issue.1 , pp. 62-67
    • Kober, F.1    Iltis, I.2    Izquierdo, M.3    Desrois, M.4    Ibarrola, D.5    Cozzone, P.J.6    Bernard, M.7
  • 6
    • 14744290653 scopus 로고    scopus 로고
    • In vivo assessment of absolute perfusion and intracapillary blood volume in the murine myocardium by spin labeling magnetic resonance imaging
    • 10.1002/mrm.20327 15723416
    • In vivo assessment of absolute perfusion and intracapillary blood volume in the murine myocardium by spin labeling magnetic resonance imaging. Streif JU, Nahrendorf M, Hiller KH, Waller C, Wiesmann F, Rommel E, Haase A, Bauer WR, Magn Reson Med 2005 53 3 584 592 10.1002/mrm.20327 15723416
    • (2005) Magn Reson Med , vol.53 , Issue.3 , pp. 584-592
    • Streif, J.U.1    Nahrendorf, M.2    Hiller, K.H.3    Waller, C.4    Wiesmann, F.5    Rommel, E.6    Haase, A.7    Bauer, W.R.8
  • 7
    • 18244409380 scopus 로고    scopus 로고
    • Accurate myocardial T1 measurements: Toward quantification of myocardial blood flow with arterial spin labeling
    • 10.1002/mrm.20461 15844151
    • Accurate myocardial T1 measurements: toward quantification of myocardial blood flow with arterial spin labeling. Zhang H, Shea SM, Park V, Li D, Woodard PK, Gropler RJ, Zheng J, Magn Reson Med 2005 53 5 1135 1142 10.1002/mrm.20461 15844151
    • (2005) Magn Reson Med , vol.53 , Issue.5 , pp. 1135-1142
    • Zhang, H.1    Shea, S.M.2    Park, V.3    Li, D.4    Woodard, P.K.5    Gropler, R.J.6    Zheng, J.7
  • 8
    • 0031821720 scopus 로고    scopus 로고
    • A general kinetic model for quantitative perfusion imaging with arterial spin labeling
    • 10.1002/mrm.1910400308 9727941
    • A general kinetic model for quantitative perfusion imaging with arterial spin labeling. Buxton RB, Frank LR, Wong EC, Siewert B, Warach S, Edelman RR, Magn Reson Med 1998 40 3 383 396 10.1002/mrm.1910400308 9727941
    • (1998) Magn Reson Med , vol.40 , Issue.3 , pp. 383-396
    • Buxton, R.B.1    Frank, L.R.2    Wong, E.C.3    Siewert, B.4    Warach, S.5    Edelman, R.R.6
  • 10
    • 70349622976 scopus 로고    scopus 로고
    • Assessment of myocardial blood flow (MBF) in humans using arterial spin labeling (ASL): Feasibility and noise analysis
    • 10.1002/mrm.22088 19672944
    • Assessment of myocardial blood flow (MBF) in humans using arterial spin labeling (ASL): feasibility and noise analysis. Zun Z, Wong EC, Nayak KS, Magn Reson Med 2009 62 4 975 983 10.1002/mrm.22088 19672944
    • (2009) Magn Reson Med , vol.62 , Issue.4 , pp. 975-983
    • Zun, Z.1    Wong, E.C.2    Nayak, K.S.3
  • 11
    • 0032957305 scopus 로고    scopus 로고
    • Implementation of quantitative FAIR perfusion imaging with a short repetition time in time-course studies
    • 10.1002/(SICI)1522-2594(199904)41:4<829: AID-MRM24>3.0.CO;2-U 10332861
    • Implementation of quantitative FAIR perfusion imaging with a short repetition time in time-course studies. Pell GS, Thomas DL, Lythgoe MF, Calamante F, Howseman AM, Gadian DG, Ordidge RJ, Magn Reson Med 1999 41 4 829 840 10.1002/(SICI)1522-2594(199904)41:4<829::AID-MRM24>3.0.CO;2-U 10332861
    • (1999) Magn Reson Med , vol.41 , Issue.4 , pp. 829-840
    • Pell, G.S.1    Thomas, D.L.2    Lythgoe, M.F.3    Calamante, F.4    Howseman, A.M.5    Gadian, D.G.6    Ordidge, R.J.7
  • 12
    • 0030608757 scopus 로고    scopus 로고
    • The effect of perfusion on T1 after slice-selective spin inversion in the isolated cardioplegic rat heart: Measurement of a lower bound of intracapillary-extravascular water proton exchange rate
    • 10.1002/mrm.1910380610 9402192
    • The effect of perfusion on T1 after slice-selective spin inversion in the isolated cardioplegic rat heart: measurement of a lower bound of intracapillary-extravascular water proton exchange rate. Bauer WR, Roder F, Hiller KH, Han H, Frohlich S, Rommel E, Haase A, Ertl G, Magn Reson Med 1997 38 6 917 923 10.1002/mrm.1910380610 9402192
    • (1997) Magn Reson Med , vol.38 , Issue.6 , pp. 917-923
    • Bauer, W.R.1    Roder, F.2    Hiller, K.H.3    Han, H.4    Frohlich, S.5    Rommel, E.6    Haase, A.7    Ertl, G.8
  • 13
    • 0026767091 scopus 로고
    • Theory of contrast agents in magnetic resonance imaging: Coupling of spin relaxation and transport
    • 10.1002/mrm.1910260104 1625562
    • Theory of contrast agents in magnetic resonance imaging: coupling of spin relaxation and transport. Bauer WR, Schulten K, Magn Reson Med 1992 26 1 16 39 10.1002/mrm.1910260104 1625562
    • (1992) Magn Reson Med , vol.26 , Issue.1 , pp. 16-39
    • Bauer, W.R.1    Schulten, K.2
  • 14
    • 14744293746 scopus 로고    scopus 로고
    • Myocardial blood flow mapping in mice using high-resolution spin labeling magnetic resonance imaging: Influence of ketamine/xylazine and isoflurane anesthesia
    • 10.1002/mrm.20373 15723407
    • Myocardial blood flow mapping in mice using high-resolution spin labeling magnetic resonance imaging: influence of ketamine/xylazine and isoflurane anesthesia. Kober F, Iltis I, Cozzone PJ, Bernard M, Magn Reson Med 2005 53 3 601 606 10.1002/mrm.20373 15723407
    • (2005) Magn Reson Med , vol.53 , Issue.3 , pp. 601-606
    • Kober, F.1    Iltis, I.2    Cozzone, P.J.3    Bernard, M.4
  • 16
    • 0033840444 scopus 로고    scopus 로고
    • Fluospheres for cardiovascular phenotyping genetically modified mice
    • 10.1097/00005344-200009000-00017 10975599
    • Fluospheres for cardiovascular phenotyping genetically modified mice. Richer C, Domergue V, Gervais M, Bruneval P, Giudicelli JF, J Cardiovasc Pharmacol 2000 36 3 396 404 10.1097/00005344-200009000-00017 10975599
    • (2000) J Cardiovasc Pharmacol , vol.36 , Issue.3 , pp. 396-404
    • Richer, C.1    Domergue, V.2    Gervais, M.3    Bruneval, P.4    Giudicelli, J.F.5
  • 17
    • 77649092074 scopus 로고    scopus 로고
    • Improved arterial spin labeling after myocardial infarction in mice using cardiac and respiratory gated look-locker imaging with fuzzy C-means clustering
    • 10.1002/mrm.22280 20187175
    • Improved arterial spin labeling after myocardial infarction in mice using cardiac and respiratory gated look-locker imaging with fuzzy C-means clustering. Vandsburger MH, Janiczek RL, Xu Y, French BA, Meyer CH, Kramer CM, Epstein FH, Magn Reson Med 2010 63 3 648 657 10.1002/mrm.22280 20187175
    • (2010) Magn Reson Med , vol.63 , Issue.3 , pp. 648-657
    • Vandsburger, M.H.1    Janiczek, R.L.2    Xu, Y.3    French, B.A.4    Meyer, C.H.5    Kramer, C.M.6    Epstein, F.H.7
  • 18
    • 78649599330 scopus 로고    scopus 로고
    • First-pass contrast-enhanced myocardial perfusion MRI in mice on a 3-T clinical MR scanner
    • 10.1002/mrm.22470 20928891
    • First-pass contrast-enhanced myocardial perfusion MRI in mice on a 3-T clinical MR scanner. Makowski M, Jansen C, Webb I, Chiribiri A, Nagel E, Botnar R, Kozerke S, Plein S, Magn Reson Med 2010 64 6 1592 1598 10.1002/mrm.22470 20928891
    • (2010) Magn Reson Med , vol.64 , Issue.6 , pp. 1592-1598
    • Makowski, M.1    Jansen, C.2    Webb, I.3    Chiribiri, A.4    Nagel, E.5    Botnar, R.6    Kozerke, S.7    Plein, S.8
  • 19
  • 20
    • 36249001590 scopus 로고    scopus 로고
    • Multi-parameter in vivo cardiac magnetic resonance imaging demonstrates normal perfusion reserve despite severely attenuated beta-adrenergic functional response in neuronal nitric oxide synthase knockout mice
    • 10.1093/eurheartj/ehm241 17602202
    • Multi-parameter in vivo cardiac magnetic resonance imaging demonstrates normal perfusion reserve despite severely attenuated beta-adrenergic functional response in neuronal nitric oxide synthase knockout mice. Vandsburger MH, French BA, Helm PA, Roy RJ, Kramer CM, Young AA, Epstein FH, Eur Heart J 2007 28 22 2792 2798 10.1093/eurheartj/ehm241 17602202
    • (2007) Eur Heart J , vol.28 , Issue.22 , pp. 2792-2798
    • Vandsburger, M.H.1    French, B.A.2    Helm, P.A.3    Roy, R.J.4    Kramer, C.M.5    Young, A.A.6    Epstein, F.H.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.