-
1
-
-
20444498492
-
How much liver resection is too much?
-
15972178 10.1016/j.amjsurg.2005.01.043
-
Mullin EJ, Metcalfe MS, Maddern GJ (2005) How much liver resection is too much? Am J Surg 190:87-97
-
(2005)
Am J Surg
, vol.190
, pp. 87-97
-
-
Mullin, E.J.1
Metcalfe, M.S.2
Maddern, G.J.3
-
2
-
-
39749198275
-
Pushing back the frontiers of resectability in liver cancer surgery
-
17949941 10.1016/j.ejso.2007.07.201 1:STN:280:DC%2BD1c7msValtQ%3D%3D
-
Abu Hilal M, Lodge JP (2008) Pushing back the frontiers of resectability in liver cancer surgery. Eur J Surg Oncol 34:272-280
-
(2008)
Eur J Surg Oncol
, vol.34
, pp. 272-280
-
-
Abu Hilal, M.1
Lodge, J.P.2
-
3
-
-
37549026473
-
Preoperative portal vein embolization for major liver resection: A meta-analysis
-
18156923 10.1097/SLA.0b013e31815f6e5b
-
Abulkhir A, Limongelli P, Healey AJ et al (2008) Preoperative portal vein embolization for major liver resection: a meta-analysis. Ann Surg 247:49-57
-
(2008)
Ann Surg
, vol.247
, pp. 49-57
-
-
Abulkhir, A.1
Limongelli, P.2
Healey, A.J.3
-
4
-
-
64249087690
-
Long-term survival and disease recurrence following portal vein embolisation prior to major hepatectomy for colorectal metastases
-
19130138 10.1245/s10434-008-0269-4
-
Pamecha V, Glantzounis G, Davies N et al (2009) Long-term survival and disease recurrence following portal vein embolisation prior to major hepatectomy for colorectal metastases. Ann Surg Oncol 16:1202-1207
-
(2009)
Ann Surg Oncol
, vol.16
, pp. 1202-1207
-
-
Pamecha, V.1
Glantzounis, G.2
Davies, N.3
-
5
-
-
40949095671
-
Preoperative contralateral portal vein embolization before major hepatic resection is a safe and efficient procedure: A large single institution experience
-
18374044 10.1016/j.surg.2007.12.006
-
Giraudo G, Greget M, Oussoultzoglou E et al (2008) Preoperative contralateral portal vein embolization before major hepatic resection is a safe and efficient procedure: a large single institution experience. Surgery 143:476-482
-
(2008)
Surgery
, vol.143
, pp. 476-482
-
-
Giraudo, G.1
Greget, M.2
Oussoultzoglou, E.3
-
6
-
-
0036727567
-
Transhepatic portal vein embolization: Anatomy, indications, and technical considerations
-
12235336
-
Madoff DC, Hicks ME, Vauthey JN et al (2002) Transhepatic portal vein embolization: anatomy, indications, and technical considerations. Radiographics 22:1063-1076
-
(2002)
Radiographics
, vol.22
, pp. 1063-1076
-
-
Madoff, D.C.1
Hicks, M.E.2
Vauthey, J.N.3
-
7
-
-
35548954130
-
Preoperative portal vein embolization: Indications and technical considerations
-
17980321 10.1053/j.tvir.2007.08.003
-
de Baere T, Denys A, Madoff DC (2007) Preoperative portal vein embolization: indications and technical considerations. Tech Vasc Interv Radiol 10:67-78
-
(2007)
Tech Vasc Interv Radiol
, vol.10
, pp. 67-78
-
-
De Baere, T.1
Denys, A.2
Madoff, D.C.3
-
8
-
-
19944430451
-
Preoperative percutaneous portal vein embolization: Evaluation of adverse events in 188 patients
-
15591428 10.1148/radiol.2342031996
-
Stefano DRD, de Baere T, Denys A et al (2005) Preoperative percutaneous portal vein embolization: evaluation of adverse events in 188 patients. Radiology 234:625-630
-
(2005)
Radiology
, vol.234
, pp. 625-630
-
-
Stefano, D.R.D.1
De Baere, T.2
Denys, A.3
-
9
-
-
0037564117
-
Transjugular preoperative portal embolization (TJPE) a pilot study
-
12828044
-
Perarnau JM, Daradkeh S, Johann M et al (2003) Transjugular preoperative portal embolization (TJPE) a pilot study. Hepatogastroenterology 50:610-613
-
(2003)
Hepatogastroenterology
, vol.50
, pp. 610-613
-
-
Perarnau, J.M.1
Daradkeh, S.2
Johann, M.3
-
10
-
-
33947727760
-
Transarterial versus transhepatic portal vein embolization to induce selective hepatic hypertrophy: A comparative study in swine
-
17296708 10.1016/j.jvir.2006.10.018
-
Madoff DC, Gupta S, Pillsbury EP et al (2007) Transarterial versus transhepatic portal vein embolization to induce selective hepatic hypertrophy: a comparative study in swine. J Vasc Interv Radiol 18:79-93
-
(2007)
J Vasc Interv Radiol
, vol.18
, pp. 79-93
-
-
Madoff, D.C.1
Gupta, S.2
Pillsbury, E.P.3
-
11
-
-
0036581726
-
Wedged hepatic venography for targeting the portal vein during TIPS: Comparison of carbon dioxide and iodinated contrast agents
-
12058211 10.1007/s00270-001-0096-5
-
Krajina A, Lojik M, Chovanec V et al (2002) Wedged hepatic venography for targeting the portal vein during TIPS: comparison of carbon dioxide and iodinated contrast agents. Cardiovasc Intervent Radiol 25:171-175
-
(2002)
Cardiovasc Intervent Radiol
, vol.25
, pp. 171-175
-
-
Krajina, A.1
Lojik, M.2
Chovanec, V.3
-
12
-
-
33751278444
-
The use of carbon dioxide wedged hepatic venography to identify the portal vein: Comparison with direct catheter portography with iodinated contrast medium and analysis of predictive factors influencing level of opacification
-
17142707 10.1097/01.RVI.0000242185.26944.60
-
Maleux G, Nevens F, Heye S et al (2006) The use of carbon dioxide wedged hepatic venography to identify the portal vein: comparison with direct catheter portography with iodinated contrast medium and analysis of predictive factors influencing level of opacification. J Vasc Interv Radiol 17:1771-1779
-
(2006)
J Vasc Interv Radiol
, vol.17
, pp. 1771-1779
-
-
Maleux, G.1
Nevens, F.2
Heye, S.3
-
13
-
-
0034029889
-
CO(2) wedged hepatic venography in the evaluation of portal hypertension
-
10807900 10.1136/gut.46.6.856 1:STN:280:DC%2BD3c3ntVSmtg%3D%3D
-
Debernardi-Venon W, Bandi JC, Garcia-Pagan JC et al (2000) CO(2) wedged hepatic venography in the evaluation of portal hypertension. Gut 46:856-860
-
(2000)
Gut
, vol.46
, pp. 856-860
-
-
Debernardi-Venon, W.1
Bandi, J.C.2
Garcia-Pagan, J.C.3
-
14
-
-
0037393122
-
Segmental nature of the porcine liver and its potential as a model for experimental partial hepatectomy
-
12673745 10.1002/bjs.4053 1:STN:280:DC%2BD3s7ls1yitQ%3D%3D
-
Court FG, Wemyss-Holden SA, Morrison CP et al (2003) Segmental nature of the porcine liver and its potential as a model for experimental partial hepatectomy. Br J Surg 90:440-444
-
(2003)
Br J Surg
, vol.90
, pp. 440-444
-
-
Court, F.G.1
Wemyss-Holden, S.A.2
Morrison, C.P.3
-
15
-
-
0017590967
-
Intrahepatic vascular division in the pig: Basis for partial hepatectomies
-
318828 10.1001/archsurg.1977.01370010040007 1:STN:280: DyaE2s%2Fos1KrtQ%3D%3D
-
Camprodon R, Solsona J, Guerrero JA et al (1977) Intrahepatic vascular division in the pig: basis for partial hepatectomies. Arch Surg 112:38-40
-
(1977)
Arch Surg
, vol.112
, pp. 38-40
-
-
Camprodon, R.1
Solsona, J.2
Guerrero, J.A.3
-
16
-
-
0345164356
-
Nonadhesive liquid embolic agent for cerebral arteriovenous malformations: Preliminary histopathological studies in swine rete mirabile
-
9802860 10.1097/00006123-199811000-00081 1:STN:280:DyaK1M%2Fhslylsg%3D%3D
-
Murayama Y, Vinuela F, Ulhoa A et al (1998) Nonadhesive liquid embolic agent for cerebral arteriovenous malformations: preliminary histopathological studies in swine rete mirabile. Neurosurgery 43:1164-1175
-
(1998)
Neurosurgery
, vol.43
, pp. 1164-1175
-
-
Murayama, Y.1
Vinuela, F.2
Ulhoa, A.3
-
18
-
-
0036494282
-
A new liquid embolic material for liver tumors
-
12010301 1:STN:280:DC%2BD38zivVWhsw%3D%3D
-
Komemushi A, Tanigawa N, Okuda Y et al (2002) A new liquid embolic material for liver tumors. Acta Radiol 43:186-191
-
(2002)
Acta Radiol
, vol.43
, pp. 186-191
-
-
Komemushi, A.1
Tanigawa, N.2
Okuda, Y.3
-
19
-
-
2442713397
-
Catheter replacement of the needle in percutaneous arteriography: A new technique
-
13057644 10.3109/00016925309136722 1:STN:280:DyaG3s%2Fot1Kjtw%3D%3D
-
Seldinger SI (1953) Catheter replacement of the needle in percutaneous arteriography: a new technique. Acta Radiol 39:368-376
-
(1953)
Acta Radiol
, vol.39
, pp. 368-376
-
-
Seldinger, S.I.1
-
20
-
-
46149118864
-
Curative embolization of cerebral arteriovenous malformations (AVMs) with Onyx in 101 patients
-
18408923 10.1007/s00234-008-0382-x
-
Katsaridis V, Papagiannaki C, Aimar E (2008) Curative embolization of cerebral arteriovenous malformations (AVMs) with Onyx in 101 patients. Neuroradiology 50:589-597
-
(2008)
Neuroradiology
, vol.50
, pp. 589-597
-
-
Katsaridis, V.1
Papagiannaki, C.2
Aimar, E.3
-
21
-
-
0030932272
-
A general model for the origin of allometric scaling laws in biology
-
9082983 10.1126/science.276.5309.122 1:CAS:528:DyaK2sXitl2jtro%3D
-
West GB, Brown JH, Enquist BJ (1997) A general model for the origin of allometric scaling laws in biology. Science 276:122-126
-
(1997)
Science
, vol.276
, pp. 122-126
-
-
West, G.B.1
Brown, J.H.2
Enquist, B.J.3
-
22
-
-
0032861303
-
Experimental evaluation of cellulose acetate NF and ethylene-vinyl alcohol copolymer for selective arterial embolization
-
10527198 10.1016/S1051-0443(99)70221-6 1:STN:280:DyaK1MvlsVehsA%3D%3D
-
Wright KC, Greff RJ, Price RE (1999) Experimental evaluation of cellulose acetate NF and ethylene-vinyl alcohol copolymer for selective arterial embolization. J Vasc Interv Radiol 10:1207-1218
-
(1999)
J Vasc Interv Radiol
, vol.10
, pp. 1207-1218
-
-
Wright, K.C.1
Greff, R.J.2
Price, R.E.3
-
24
-
-
0036150733
-
Combined therapy of cerebral arteriovenous malformations: Histological differences between a non-adhesive liquid embolic agent and n-butyl 2-cyanoacrylate (NBCA)
-
11846039 1:STN:280:DC%2BD387hsVarsA%3D%3D
-
Duffner F, Ritz R, Bomemann A et al (2002) Combined therapy of cerebral arteriovenous malformations: histological differences between a non-adhesive liquid embolic agent and n-butyl 2-cyanoacrylate (NBCA). Clin Neuropathol 21:13-17
-
(2002)
Clin Neuropathol
, vol.21
, pp. 13-17
-
-
Duffner, F.1
Ritz, R.2
Bomemann, A.3
-
25
-
-
0037352820
-
Efficacy and low vascular toxicity of embolization with radical versus anionic polymerization of n-butyl-2-cyanoacrylate (NBCA). An experimental study in the swine
-
12717295 1:STN:280:DC%2BD3s7pslKhug%3D%3D
-
Levrier O, Mekkaoui C, Rolland PH et al (2003) Efficacy and low vascular toxicity of embolization with radical versus anionic polymerization of n-butyl-2-cyanoacrylate (NBCA). An experimental study in the swine. J Neuroradiol 30:95-102
-
(2003)
J Neuroradiol
, vol.30
, pp. 95-102
-
-
Levrier, O.1
Mekkaoui, C.2
Rolland, P.H.3
-
26
-
-
67349178858
-
Comparison of four embolic materials for portal vein embolization: Experimental study in pigs
-
19153743 10.1007/s00330-008-1277-2
-
de Baere T, Denys A, Paradis V (2009) Comparison of four embolic materials for portal vein embolization: experimental study in pigs. Eur Radiol 19(6):1435-1442
-
(2009)
Eur Radiol
, vol.19
, Issue.6
, pp. 1435-1442
-
-
De Baere, T.1
Denys, A.2
Paradis, V.3
-
27
-
-
0025767646
-
Liver units in three dimensions: I. Organization of argyrophilic connective tissue skeleton in porcine liver with particular reference to the compound hepatic lobule
-
1862757 10.1002/aja.1001910202 1:STN:280:DyaK3MzitVyhtg%3D%3D
-
Ekataksin W, Wake K (1991) Liver units in three dimensions: I. Organization of argyrophilic connective tissue skeleton in porcine liver with particular reference to the compound hepatic lobule. Am J Anat 191:113-153
-
(1991)
Am J Anat
, vol.191
, pp. 113-153
-
-
Ekataksin, W.1
Wake, K.2
|