메뉴 건너뛰기




Volumn 47, Issue 11, 2012, Pages 662-670

In Vivo cardiac diffusion-weighted magnetic resonance imaging: Quantification of normal perfusion and diffusion coefficients with intravoxel incoherent motion imaging

Author keywords

diffusion weighted imaging; heart; in vivo; IVIM; PCA; temporal MIP

Indexed keywords

ACCURACY; ADULT; ALGORITHM; ARTICLE; BREATH HOLDING; CARDIAC IMAGING; CARDIOVASCULAR MAGNETIC RESONANCE; CONTROLLED STUDY; DIASTOLE; DIFFUSION COEFFICIENT; DIFFUSION WEIGHTED IMAGING; FEASIBILITY STUDY; FEMALE; HEART CYCLE; HUMAN; HUMAN EXPERIMENT; IN VIVO STUDY; INFORMATION PROCESSING; INTRAVOXEL INCOHERENT MOTION IMAGING; MALE; METHODOLOGY; NORMAL HUMAN; PERFUSION; PRINCIPAL COMPONENT ANALYSIS; PRIORITY JOURNAL; SCINTIGRAPHY; SIMULATION; STATISTICAL SIGNIFICANCE;

EID: 84867237972     PISSN: 00209996     EISSN: 15360210     Source Type: Journal    
DOI: 10.1097/RLI.0b013e31826ef901     Document Type: Article
Times cited : (52)

References (28)
  • 1
    • 0022969218 scopus 로고
    • MR imaging of intravoxel incoherent motions: Applications to diffusion and perfusion in neurologic disorders
    • Le Bihan D, Breton E, Lallemand D, et al. MR imaging of intravoxel incoherent motions: applications to diffusion and perfusion in neurologic disorders. Radiology. 1986;1161:401-407.
    • (1986) Radiology , vol.1161 , pp. 401-407
    • Le Bihan, D.1    Breton, E.2    Lallemand, D.3
  • 2
    • 0035080580 scopus 로고    scopus 로고
    • Diffusion tensor imaging: Concepts and applications
    • Le Bihan D, Mangin J, Poupon C, et al. Diffusion tensor imaging: concepts and applications. J Magn Reson Imaging. 2001;13:534-546.
    • (2001) J Magn Reson Imaging , vol.13 , pp. 534-546
    • Le Bihan, D.1    Mangin, J.2    Poupon, C.3
  • 3
    • 0023678634 scopus 로고
    • Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging
    • Le Bihan D, Breton E, Lallemand D, et al. Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging. Radiology. 1988;168:497-505.
    • (1988) Radiology , vol.168 , pp. 497-505
    • Le Bihan, D.1    Breton, E.2    Lallemand, D.3
  • 4
    • 0032975435 scopus 로고    scopus 로고
    • Diffusion coefficients in abdominal organs and hepatic lesions: Evaluation with intravoxel incoherent motion echo-planar MR imaging
    • Yamada I, AungW, Himeno Y, et al. Diffusion coefficients in abdominal organs and hepatic lesions: evaluation with intravoxel incoherent motion echo-planar MR imaging. Radiology. 1999;210:617-623.
    • (1999) Radiology , vol.210 , pp. 617-623
    • Yamada, I.1    Aungw Himeno, Y.2
  • 5
    • 79954733420 scopus 로고    scopus 로고
    • Comparison of biexponential and monoexponential model of diffusion weighted imaging in evaluation of renal lesions: Preliminary experience
    • Chandarana H, Lee VS, Hecht E, et al. Comparison of biexponential and monoexponential model of diffusion weighted imaging in evaluation of renal lesions: preliminary experience. Invest Radiol. 2011;46:285-291.
    • (2011) Invest Radiol , vol.46 , pp. 285-291
    • Chandarana, H.1    Lee, V.S.2    Hecht, E.3
  • 6
    • 73349104651 scopus 로고    scopus 로고
    • Differentiation of pancreas carcinoma from healthy pancreatic tissue using multiple b-values: Comparison of apparent diffusion coefficient and intravoxel incoherent motion derived parameters
    • Lemke A, Laun FB, Klau M, et al. Differentiation of pancreas carcinoma from healthy pancreatic tissue using multiple b-values: comparison of apparent diffusion coefficient and intravoxel incoherent motion derived parameters. Invest Radiol. 2009;44:769-775.
    • (2009) Invest Radiol , vol.44 , pp. 769-775
    • Lemke, A.1    Laun, F.B.2    Klau, M.3
  • 7
    • 58149179092 scopus 로고    scopus 로고
    • Liver cirrhosis: Intravoxel incoherent motion MR imagingVpilot study
    • Luciani A, Vignaud A, Cavet M, et al. Liver cirrhosis: intravoxel incoherent motion MR imagingVpilot study. Radiology. 2008;249:891-899.
    • (2008) Radiology , vol.249 , pp. 891-899
    • Luciani, A.1    Vignaud, A.2    Cavet, M.3
  • 8
    • 77649216180 scopus 로고    scopus 로고
    • Diagnosis of cirrhosis with intravoxel incoherent motion diffusion MRI and dynamic contrast-enhanced MRI alone and in combination: Preliminary experience
    • Patel J, Sigmund EE, Rusinek H, et al. Diagnosis of cirrhosis with intravoxel incoherent motion diffusion MRI and dynamic contrast-enhanced MRI alone and in combination: preliminary experience. J Magn Reson Imaging. 2010;31: 589-600.
    • (2010) J Magn Reson Imaging , vol.31 , pp. 589-600
    • Patel, J.1    Sigmund, E.E.2    Rusinek, H.3
  • 9
    • 78649555277 scopus 로고    scopus 로고
    • An in vivo verification of the intravoxel incoherent motion effect in diffusion-weighted imaging of the abdomen
    • Lemke A, Laun FB, Simon D, et al. An in vivo verification of the intravoxel incoherent motion effect in diffusion-weighted imaging of the abdomen. Magn Reson Med. 2010;64:1580-1585.
    • (2010) Magn Reson Med , vol.64 , pp. 1580-1585
    • Lemke, A.1    Laun, F.B.2    Simon, D.3
  • 10
    • 0042817820 scopus 로고    scopus 로고
    • Vivo study of microcirculation in canine myocardium using the IVIM method
    • Callot V, Bennett E, Decking UKM, et al. In vivo study of microcirculation in canine myocardium using the IVIM method. Magn Reson Med. 2003;50: 531-540.
    • (2003) Magn Reson Med , vol.50 , pp. 531-540
    • Callot, V.1    Bennett, E.2    Decking, U.K.M.3
  • 11
    • 81855213068 scopus 로고    scopus 로고
    • Low b-value diffusion-weighted cardiac magnetic resonance imaging initial results in humans using an optimal timewindow imaging approach
    • Rapacchi S, Wen H, Viallon M, et al. Low b-value diffusion-weighted cardiac magnetic resonance imaging initial results in humans using an optimal timewindow imaging approach. Invest Radiol. 2011;46:751-758.
    • (2011) Invest Radiol , vol.46 , pp. 751-758
    • Rapacchi, S.1    Wen, H.2    Viallon, M.3
  • 12
    • 78650552408 scopus 로고    scopus 로고
    • Diffusion-weighted echo planar imaging in patients with recent myocardial infarction
    • Deux J-F, Maatouk M, Vignaud A, et al. Diffusion-weighted echo planar imaging in patients with recent myocardial infarction. Eur Radiol. 2011;21: 46-53.
    • (2011) Eur Radiol , vol.21 , pp. 46-53
    • Deux, J.-F.1    Maatouk, M.2    Vignaud, A.3
  • 13
    • 79953013835 scopus 로고    scopus 로고
    • Diffusion-weighted MR imaging of native and transplanted kidne-S
    • Thoney HC, De Keyzer F. Diffusion-weighted MR imaging of native and transplanted kidne-S. Radiology. 2011;259:25-38.
    • (2011) Radiology , vol.259 , pp. 25-38
    • Thoney, H.C.1    De Keyzer, F.2
  • 14
    • 0030278692 scopus 로고    scopus 로고
    • Anal-Sis and comparison of motioncorrection techniques in diffusion-weighted imaging
    • Trouard T, Sabharwal Y, Altlbach M, et al. Anal-Sis and comparison of motioncorrection techniques in diffusion-weighted imaging. J Magn Reson Imaging. 1996;6:925-935.
    • (1996) J Magn Reson Imaging , vol.6 , pp. 925-935
    • Trouard, T.1    Sabharwal, Y.2    Altlbach, M.3
  • 15
    • 79958254588 scopus 로고    scopus 로고
    • PCATMIP: Enhancing signal intensity in diffusion-weighted magnetic resonance imaging
    • Pai VM, Rapacchi S, Kellman P, et al. PCATMIP: enhancing signal intensity in diffusion-weighted magnetic resonance imaging. Magn Reson Med. 2011; 65:1611-1619.
    • (2011) Magn Reson Med , vol.65 , pp. 1611-1619
    • Pai, V.M.1    Rapacchi, S.2    Kellman, P.3
  • 16
    • 84867250772 scopus 로고    scopus 로고
    • Bipolar diffusion encoding with implicit spoiling of undesired coherence pathwa-S
    • Paper presented at the conference Montreal, Canada. ISMRM Abstract 2011. 2010
    • Feiweier T. Bipolar diffusion encoding with implicit spoiling of undesired coherence pathwa-S. Paper presented at the conference, International Society of Magnetic Resonance in Medicine (ISMM); 2011; Montreal, Canada. ISMRM Abstract 2011. 2010;1-1.
    • (2011) International Society of Magnetic Resonance in Medicine (ISMM) , pp. 1-1
    • Feiweier, T.1
  • 17
    • 0023276045 scopus 로고
    • Gradient reversal technique and its applications to chemical-shift- related NMR imaging
    • Park HW, Kim DJ, Cho ZH. Gradient reversal technique and its applications to chemical-shift-related NMR imaging. Magn Reson Med. 1987;4: 526-536.
    • (1987) Magn Reson Med , vol.4 , pp. 526-536
    • Park, H.W.1    Kim, D.J.2    Cho, Z.H.3
  • 18
    • 4644328024 scopus 로고    scopus 로고
    • Modified look-locker inversion recovery (MOLLI) for high-resolution T1 mapping of the heart
    • Messroghli DR, Radjenovic A, Kozerke S, et al. Modified Look-Locker Inversion Recovery (MOLLI) for high-resolution T1 mapping of the heart. Magn Reson Med. 2004;52:141-146.
    • (2004) Magn Reson Med , vol.52 , pp. 141-146
    • Messroghli, D.R.1    Radjenovic, A.2    Kozerke, S.3
  • 19
    • 84861231992 scopus 로고    scopus 로고
    • Motion correction for myocardial T1 mapping using image registration with synthetic image estimation
    • Xue H, Shah S, Greiser A, et al. Motion correction for myocardial T1 mapping using image registration with synthetic image estimation. Magn Reson Med. 2012;67:1644-1655.
    • (2012) Magn Reson Med , vol.67 , pp. 1644-1655
    • Xue, H.1    Shah, S.2    Greiser, A.3
  • 20
    • 77649199303 scopus 로고    scopus 로고
    • T2 quantification for improved detection of myocardial edema
    • Giri S, Chung Y-C, Merchant A, et al. T2 quantification for improved detection of myocardial edema. J Cardiovasc Magn Reson. 2009;11:56.
    • (2009) J Cardiovasc Magn Reson , vol.11 , pp. 56
    • Giri, S.1    Chung, Y.-C.2    Merchant, A.3
  • 21
    • 34547879249 scopus 로고    scopus 로고
    • Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters
    • Dietrich O, Raya J, Reeder S, et al. Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters. J Magn Reson Imaging. 2007;26:375-385.
    • (2007) J Magn Reson Imaging , vol.26 , pp. 375-385
    • Dietrich, O.1    Raya, J.2    Reeder, S.3
  • 23
    • 79959223816 scopus 로고    scopus 로고
    • Toward an optimal distribution of b values for intravoxel incoherent motion imaging
    • Lemke A, Stieltjes B, Schad LR, et al. Toward an optimal distribution of b values for intravoxel incoherent motion imaging. Magn Reson Imaging. 2011;29:766-776.
    • (2011) Magn Reson Imaging , vol.29 , pp. 766-776
    • Lemke, A.1    Stieltjes, B.2    Schad, L.R.3
  • 24
    • 0028133448 scopus 로고
    • In vivo measurement of water diffusion in the human heart
    • Edelman RR, Gaa J, Wedeen VJ, et al. In vivo measurement of water diffusion in the human heart. Magn Reson Med. 1994;32:423-428.
    • (1994) Magn Reson Med , vol.32 , pp. 423-428
    • Edelman, R.R.1    Gaa, J.2    Wedeen, V.J.3
  • 25
    • 0037022234 scopus 로고    scopus 로고
    • Dynamic changes in three-dimensional architecture and vascular volume of transmural coronary microvasculature between diastolic-and s-Stolic-arrested rat hearts
    • Toyota E, FujimotoK,OgasawaraY, et al. Dynamic changes in three-dimensional architecture and vascular volume of transmural coronary microvasculature between diastolic-and s-Stolic-arrested rat hearts. Circulation. 2002;105:621-626.
    • (2002) Circulation , vol.105 , pp. 621-626
    • Toyota, E.1    Fujimoto, K.2    Ogasawara, Y.3
  • 26
    • 24144448806 scopus 로고    scopus 로고
    • T1, T2 relaxation and magnetization transfer in tissue at 3T
    • Stanisz GJ, Odrobina EE, Pun J, et al. T1, T2 relaxation and magnetization transfer in tissue at 3T. Magn Reson Med. 2005;54:507-512.
    • (2005) Magn Reson Med , vol.54 , pp. 507-512
    • Stanisz, G.J.1    Odrobina, E.E.2    Pun, J.3
  • 27
    • 0025676589 scopus 로고
    • Does IVIM measure classical perfusion?
    • Henkelman RM. Does IVIM measure classical perfusion? Magn Reson Med. 1990;16:470-475.
    • (1990) Magn Reson Med , vol.16 , pp. 470-475
    • Henkelman, R.M.1
  • 28
    • 0026657951 scopus 로고
    • The capillary network: A link between IVIM and classical perfusion
    • Le Bihan D, Turner R. The capillary network: a link between IVIM and classical perfusion. Magn Reson Med. 1992;27:171-178.
    • (1992) Magn Reson Med , vol.27 , pp. 171-178
    • Le Bihan, D.1    Turner, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.