메뉴 건너뛰기




Volumn 83, Issue 11, 2012, Pages 1307-1308

Push hard and fast (but not too fast)

Author keywords

[No Author keywords available]

Indexed keywords

COMPRESSION; COMPRESSION DEPTH; DEFIBRILLATOR; EDITORIAL; HUMAN; MEDICAL PARAMETERS; MEDICAL PRACTICE; PRACTICE GUIDELINE; PRIORITY JOURNAL; QUALITY OF LIFE; RESUSCITATION; RETURN OF SPONTANEOUS CIRCULATION; THORAX COMPRESSION;

EID: 84867233140     PISSN: 03009572     EISSN: 18731570     Source Type: Journal    
DOI: 10.1016/j.resuscitation.2012.08.325     Document Type: Editorial
Times cited : (3)

References (9)
  • 1
    • 78049475784 scopus 로고    scopus 로고
    • Part 5: Adult basic life support: 2010 international consensus on cardiopulmonary resuscitation and emergency cardiovascular care science with treatment recommendations
    • Koster R.W., Sayre M.R., Botha M., et al. Part 5: Adult basic life support: 2010 international consensus on cardiopulmonary resuscitation and emergency cardiovascular care science with treatment recommendations. Resuscitation 2010, 81(Suppl. 1):e48-e70.
    • (2010) Resuscitation , vol.81 , Issue.SUPPL. 1
    • Koster, R.W.1    Sayre, M.R.2    Botha, M.3
  • 2
    • 33750173272 scopus 로고    scopus 로고
    • Effects of compression depth and pre-shock pauses predict defibrillation failure during cardiac arrest
    • Edelson D.P., Abella B.S., Kramer-Johansen J., et al. Effects of compression depth and pre-shock pauses predict defibrillation failure during cardiac arrest. Resuscitation 2006, 71:137-145.
    • (2006) Resuscitation , vol.71 , pp. 137-145
    • Edelson, D.P.1    Abella, B.S.2    Kramer-Johansen, J.3
  • 3
    • 33751254313 scopus 로고    scopus 로고
    • Quality of out-of-hospital cardiopulmonary resuscitation with real time automated feedback: a prospective interventional study
    • Kramer-Johansen J., Myklebust H., Wik L., et al. Quality of out-of-hospital cardiopulmonary resuscitation with real time automated feedback: a prospective interventional study. Resuscitation 2006, 71:283-292.
    • (2006) Resuscitation , vol.71 , pp. 283-292
    • Kramer-Johansen, J.1    Myklebust, H.2    Wik, L.3
  • 4
    • 84876325990 scopus 로고    scopus 로고
    • http://www.bhf.org.uk/heart-health/life-saving-skills/hands-only-cpr.aspx.
  • 5
    • 84857044630 scopus 로고    scopus 로고
    • The impact of chest compression rates on quality of chest compressions - a manikin study
    • Field R., Soar J., Davies R.P., Akhtar N., Perkins G.D. The impact of chest compression rates on quality of chest compressions - a manikin study. Resuscitation 2012, 83:360-364.
    • (2012) Resuscitation , vol.83 , pp. 360-364
    • Field, R.1    Soar, J.2    Davies, R.P.3    Akhtar, N.4    Perkins, G.D.5
  • 6
    • 81755171280 scopus 로고    scopus 로고
    • A higher chest compression rate may be necessary for metronome-guided cardiopulmonary resuscitation
    • Chung T.N., Kim S.W., You J.S., Cho Y.S., Chung S.P., Park I. A higher chest compression rate may be necessary for metronome-guided cardiopulmonary resuscitation. Am J Emerg Med 2012, 30:226-230.
    • (2012) Am J Emerg Med , vol.30 , pp. 226-230
    • Chung, T.N.1    Kim, S.W.2    You, J.S.3    Cho, Y.S.4    Chung, S.P.5    Park, I.6
  • 8
    • 84869088227 scopus 로고    scopus 로고
    • " Stayin' Alive" : a novel mental metronome to maintain compression rates in simulated cardiac arrests
    • Hafner J.W., Sturgell J.L., Matlock D.L., Bockewitz E.G., Barker L.T. " Stayin' Alive" : a novel mental metronome to maintain compression rates in simulated cardiac arrests. J Emerg Med 2012, 1-5.
    • (2012) J Emerg Med , pp. 1-5
    • Hafner, J.W.1    Sturgell, J.L.2    Matlock, D.L.3    Bockewitz, E.G.4    Barker, L.T.5
  • 9
    • 84867229245 scopus 로고    scopus 로고
    • Excessive chest compression rate is associated with insufficient compression depth in prehospital cardiac arrest
    • Monsieurs K.G., De Regge M., Vansteelandt K., et al. Excessive chest compression rate is associated with insufficient compression depth in prehospital cardiac arrest. Resuscitation 2012, 83:1319-1323.
    • (2012) Resuscitation , vol.83 , pp. 1319-1323
    • Monsieurs, K.G.1    De Regge, M.2    Vansteelandt, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.