메뉴 건너뛰기




Volumn 28, Issue 4, 2012, Pages 257-260

Comparative study of awake endotracheal intubation with Glidescope video laryngoscope versus flexible fiber optic bronchoscope in patients with traumatic cervical spine injury

Author keywords

Awake intubation; Cervical spine injury; Flexible fiber optic bronchoscope; Glidescope video laryngoscope; MILS; Remifentanil

Indexed keywords

GLYCOPYRRONIUM BROMIDE; MIDAZOLAM; REMIFENTANIL;

EID: 84867209295     PISSN: 11101849     EISSN: 16871804     Source Type: Journal    
DOI: 10.1016/j.egja.2012.05.002     Document Type: Article
Times cited : (27)

References (21)
  • 1
    • 33744959276 scopus 로고    scopus 로고
    • Airway management in adults after cervical spine trauma
    • E.T. Crosbay Airway management in adults after cervical spine trauma Anesthesiology 104 2006 1293 1318
    • (2006) Anesthesiology , vol.104 , pp. 1293-1318
    • Crosbay, E.T.1
  • 2
    • 0031837967 scopus 로고    scopus 로고
    • Practice patterns in managing the difficult airway by anesthesiologists in the United States
    • W.H. Rosenblatt, P.J. Wagner, A. Ovassapian, and Z.N. Kain Practice patterns in managing the difficult airway by anesthesiologists in the United States Anesth Analg 87 1998 153 157
    • (1998) Anesth Analg , vol.87 , pp. 153-157
    • Rosenblatt, W.H.1    Wagner, P.J.2    Ovassapian, A.3    Kain, Z.N.4
  • 3
    • 0031454801 scopus 로고    scopus 로고
    • Comparison of Bullard and Macintosh laryngoscopces for endotracheal intubation of patients with a potential cervical spine injury
    • A.D.J. Watts, A.W. Gelb, D.B. Bach, and D.M. Pm Comparison of Bullard and Macintosh laryngoscopces for endotracheal intubation of patients with a potential cervical spine injury Anesthesiology 87 1997 1335 1342
    • (1997) Anesthesiology , vol.87 , pp. 1335-1342
    • Watts, A.D.J.1    Gelb, A.W.2    Bach, D.B.3    Pm, D.M.4
  • 4
    • 0042424630 scopus 로고    scopus 로고
    • Use of a new videolaryngoscope (GlideScope) in the management of a difficult airway
    • R.M. Cooper Use of a new videolaryngoscope (GlideScope) in the management of a difficult airway Can J Anaesth 50 2003 611 613
    • (2003) Can J Anaesth , vol.50 , pp. 611-613
    • Cooper, R.M.1
  • 5
    • 2342648078 scopus 로고    scopus 로고
    • Awake intubation using the GlideScope video laryngoscope: Initial experience in four cases
    • D.J. Doyle Awake intubation using the GlideScope video laryngoscope: initial experience in four cases Can J Anaesth 51 2004 520 521
    • (2004) Can J Anaesth , vol.51 , pp. 520-521
    • Doyle, D.J.1
  • 6
    • 77449105751 scopus 로고    scopus 로고
    • Management of the predicted difficult airway: A comparison of conventional blade laryngoscopy with video-assisted blade laryngoscopy and the Glidescope
    • G. Serocki, B. Bein, J. Scholz, and V. Dorges Management of the predicted difficult airway: a comparison of conventional blade laryngoscopy with video-assisted blade laryngoscopy and the Glidescope Eur J Anesth 27 2010 24 30
    • (2010) Eur J Anesth , vol.27 , pp. 24-30
    • Serocki, G.1    Bein, B.2    Scholz, J.3    Dorges, V.4
  • 7
    • 0038394393 scopus 로고    scopus 로고
    • Tracheal intubation using a Macintosh laryngoscope or a GlideScope in 15 patients with cervical spine immobilization
    • F. Agro, G. Barzoi, and F. Montecchia Tracheal intubation using a Macintosh laryngoscope or a GlideScope in 15 patients with cervical spine immobilization Br J Anaesth 90 2003 705 706
    • (2003) Br J Anaesth , vol.90 , pp. 705-706
    • Agro, F.1    Barzoi, G.2    Montecchia, F.3
  • 8
    • 0043207607 scopus 로고    scopus 로고
    • Guidelines for emergency tracheal intubation immediately after traumatic injury
    • C.M. Dunham, R.D. Barraco, D.E. Clark, B.J. Daley, FEm Davis, and M.A. Gibbs Guidelines for emergency tracheal intubation immediately after traumatic injury J Trauma 55 2003 162 179
    • (2003) J Trauma , vol.55 , pp. 162-179
    • Dunham, C.M.1    Barraco, R.D.2    Clark, D.E.3    Daley, B.J.4    Davis, F.5    Gibbs, M.A.6
  • 9
    • 0027275548 scopus 로고
    • Fibreoptic intubation. Influence of tracheal tube tip design
    • H.E. Jones, A.C. Pearce, and P. Moore Fibreoptic intubation. Influence of tracheal tube tip design Anaesthesia 48 1993 672 674
    • (1993) Anaesthesia , vol.48 , pp. 672-674
    • Jones, H.E.1    Pearce, A.C.2    Moore, P.3
  • 10
    • 0442325407 scopus 로고    scopus 로고
    • Comparison of the Williams airway intubator and ovassapian fibreoptic intubating airway for fibreoptic orotracheal intubation
    • K.B. Greenland, M.C. Lam, and M.G. Irwin Comparison of the Williams airway intubator and ovassapian fibreoptic intubating airway for fibreoptic orotracheal intubation Anaesthesia 59 2004 173 176
    • (2004) Anaesthesia , vol.59 , pp. 173-176
    • Greenland, K.B.1    Lam, M.C.2    Irwin, M.G.3
  • 11
    • 0033756645 scopus 로고    scopus 로고
    • Cervical spine motion during airway management: A cinefluoroscopic study of the posteriorly destabilized third cervical vertebrae in human cadavers
    • J. Brimacombe, C. Keller, K.H. Kunzel, O. Gaber, M. Boehler, and F. Puhringer Cervical spine motion during airway management: a cinefluoroscopic study of the posteriorly destabilized third cervical vertebrae in human cadavers Anesth Analg 91 2000 1274 1278
    • (2000) Anesth Analg , vol.91 , pp. 1274-1278
    • Brimacombe, J.1    Keller, C.2    Kunzel, K.H.3    Gaber, O.4    Boehler, M.5    Puhringer, F.6
  • 12
    • 0026042901 scopus 로고
    • Cervical spine movement during airway management: Cinefluoroscopic appraisal in human cadavers
    • M. Hauswald, D.P. Sklar, D. Tandberg, and J.F. Garcia Cervical spine movement during airway management: cinefluoroscopic appraisal in human cadavers Am J Emerg Med 9 1991 535 538
    • (1991) Am J Emerg Med , vol.9 , pp. 535-538
    • Hauswald, M.1    Sklar, D.P.2    Tandberg, D.3    Garcia, J.F.4
  • 13
    • 0030912545 scopus 로고    scopus 로고
    • The effect of airway maneuvers on the unstable C1-C2 segment. A cadaver study
    • W.F. Donaldson 3rd, B.V. Heil, V.P. Donaldson, and V.J. Silvaggio The effect of airway maneuvers on the unstable C1-C2 segment. A cadaver study Spine 22 1997 1215 1218
    • (1997) Spine , vol.22 , pp. 1215-1218
    • Donaldson III, W.F.1    Heil, B.V.2    Donaldson, V.P.3    Silvaggio, V.J.4
  • 14
    • 13544263512 scopus 로고    scopus 로고
    • Evaluation of ease of intubation with the Glidscope or Macintosh laryngoscopy by anesthetists in stimulated easy and difficult laryngoscopy
    • T.J. Lim, Y. Lim, and E.H.C. Liu Evaluation of ease of intubation with the Glidscope or Macintosh laryngoscopy by anesthetists in stimulated easy and difficult laryngoscopy Anesthesia 60 2005 180 183
    • (2005) Anesthesia , vol.60 , pp. 180-183
    • Lim, T.J.1    Lim, Y.2    Liu, E.H.C.3
  • 15
    • 68849129824 scopus 로고    scopus 로고
    • Fiberoptic and videoscopic indirect intubation techniques for intubation in children
    • R. Levin, N. Kisson, and N. Froese Fiberoptic and videoscopic indirect intubation techniques for intubation in children Pediatr Emerg Care 25 2009 479
    • (2009) Pediatr Emerg Care , vol.25 , pp. 479
    • Levin, R.1    Kisson, N.2    Froese, N.3
  • 16
    • 65349141946 scopus 로고    scopus 로고
    • A comparison of cervical spine motion during orotracheal intubation with the Trachlight or the flexible fiberoptic bronchoscope
    • B.J. Houde, and S.R. Williams A comparison of cervical spine motion during orotracheal intubation with the Trachlight or the flexible fiberoptic bronchoscope Anesth Analg 108 2009 1638 1643
    • (2009) Anesth Analg , vol.108 , pp. 1638-1643
    • Houde, B.J.1    Williams, S.R.2
  • 17
    • 33646514660 scopus 로고    scopus 로고
    • Comparison of hemodynamic responses to orotracheal intubation with Glidescope videokaryngoscope and fiberoptic bronchoscope
    • F.S. Xue, G.H. Zhang, and X.Y. Li Comparison of hemodynamic responses to orotracheal intubation with Glidescope videokaryngoscope and fiberoptic bronchoscope Eur J Anesth 23 2006 522 526
    • (2006) Eur J Anesth , vol.23 , pp. 522-526
    • Xue, F.S.1    Zhang, G.H.2    Li, X.Y.3
  • 18
    • 17844399242 scopus 로고    scopus 로고
    • Endoscopic study of mechanisms of failure of endotracheal tube advancement into the trachea during awake fiberoptic orotracheal intubation
    • D.M. Johnson, A.M. From, and R.B. Smith Endoscopic study of mechanisms of failure of endotracheal tube advancement into the trachea during awake fiberoptic orotracheal intubation Anesthesiology 102 2005 910 914
    • (2005) Anesthesiology , vol.102 , pp. 910-914
    • Johnson, D.M.1    From, A.M.2    Smith, R.B.3
  • 19
    • 0036786579 scopus 로고    scopus 로고
    • Laryngeal trauma during awake fiberoptic intubation
    • M.A. Makabi, H. Hoffman, G. Funk, and R.P. From Laryngeal trauma during awake fiberoptic intubation Anesth Analg 95 2002 354 358
    • (2002) Anesth Analg , vol.95 , pp. 354-358
    • Makabi, M.A.1    Hoffman, H.2    Funk, G.3    From, R.P.4
  • 21
    • 34447628687 scopus 로고    scopus 로고
    • Perforation of the soft palate using the Glidescope videolaryngoscope
    • P. Cross, J. Cytryn, and K.K. Cheng Perforation of the soft palate using the Glidescope videolaryngoscope Can J Anesth 54 2007 588 589
    • (2007) Can J Anesth , vol.54 , pp. 588-589
    • Cross, P.1    Cytryn, J.2    Cheng, K.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.