메뉴 건너뛰기




Volumn 36, Issue 10, 2012, Pages 875-885

Clinical Evaluation of New Generation Oxygenators With Integrated Arterial Line Filters for Cardiopulmonary Bypass

Author keywords

Arterial filter; Cardiopulmonary bypass; Integrated arterial filters; Oxygenators

Indexed keywords

BANDPASS FILTERS; BIOSYNTHESIS; BLOOD VESSELS; BODY FLUIDS; DROPS; PORE SIZE; PROTEINS;

EID: 84867208023     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2012.01469.x     Document Type: Article
Times cited : (19)

References (32)
  • 1
    • 33746343009 scopus 로고    scopus 로고
    • An evidence-based review of the practice of cardiopulmonary bypass in adults: a focus on neurologic injury, glycemic control, hemodilution, and the inflammatory response
    • Shann KG, Likosky DS, Murkin JM, etal. An evidence-based review of the practice of cardiopulmonary bypass in adults: a focus on neurologic injury, glycemic control, hemodilution, and the inflammatory response. J Thorac Cardiovasc Surg 2006;132:283-90.
    • (2006) J Thorac Cardiovasc Surg , vol.132 , pp. 283-290
    • Shann, K.G.1    Likosky, D.S.2    Murkin, J.M.3
  • 2
    • 65349109242 scopus 로고    scopus 로고
    • Optimal perfusion during cardiopulmonary bypass: an evidence-based approach
    • Murphy GS, Hessel EA, Groom RC. Optimal perfusion during cardiopulmonary bypass: an evidence-based approach. Anesth Analg 2009;108:1394-417.
    • (2009) Anesth Analg , vol.108 , pp. 1394-1417
    • Murphy, G.S.1    Hessel, E.A.2    Groom, R.C.3
  • 3
    • 58149389700 scopus 로고    scopus 로고
    • Effects of phosphorylcoline coating on extracorporeal circulation management and postoperative outcome: a double-blind randomized study
    • Lorusso R, De Cicco G, Totaro P, Gelsomino S. Effects of phosphorylcoline coating on extracorporeal circulation management and postoperative outcome: a double-blind randomized study. Interact Cardiovasc Thorac Surg 2009;8:7-11.
    • (2009) Interact Cardiovasc Thorac Surg , vol.8 , pp. 7-11
    • Lorusso, R.1    De Cicco, G.2    Totaro, P.3    Gelsomino, S.4
  • 4
    • 0036672682 scopus 로고    scopus 로고
    • Coagulation, fibrinolysis, and cell activation in patients and shed mediastinal blood during coronary artery bypass grafting with a new heparin-coated surface
    • Johnell M, Elgue G, Larsson R, Larsson A, Thelin S, Siegbahn A. Coagulation, fibrinolysis, and cell activation in patients and shed mediastinal blood during coronary artery bypass grafting with a new heparin-coated surface. J Thorac Cardiovasc Surg 2002;124:321-32.
    • (2002) J Thorac Cardiovasc Surg , vol.124 , pp. 321-332
    • Johnell, M.1    Elgue, G.2    Larsson, R.3    Larsson, A.4    Thelin, S.5    Siegbahn, A.6
  • 5
    • 0032765340 scopus 로고    scopus 로고
    • Transfusions after coronary artery bypass surgery: the impact of heparin-bonded circuits
    • Mahoney CB, Lemole GM. Transfusions after coronary artery bypass surgery: the impact of heparin-bonded circuits. Eur J Cardiothorac Surg 1999;16:206-10.
    • (1999) Eur J Cardiothorac Surg , vol.16 , pp. 206-210
    • Mahoney, C.B.1    Lemole, G.M.2
  • 6
    • 0035052093 scopus 로고    scopus 로고
    • Cardiac surgical patients exposed to heparin-bonded circuits develop less postoperative cerebral dysfunction than patients to non-heparin-bonded circuits
    • Mongero LB, Beck JR, Manspeizer EJ, etal. Cardiac surgical patients exposed to heparin-bonded circuits develop less postoperative cerebral dysfunction than patients to non-heparin-bonded circuits. Perfusion 2001;16:107-11.
    • (2001) Perfusion , vol.16 , pp. 107-111
    • Mongero, L.B.1    Beck, J.R.2    Manspeizer, E.J.3
  • 7
    • 0343183931 scopus 로고    scopus 로고
    • Heparin-coated circuits reduce occult myocardial damage during CPB: a randomized, single blind clinical trial
    • Belboul A, Löfgren C, Storm C, Jungbeck M. Heparin-coated circuits reduce occult myocardial damage during CPB: a randomized, single blind clinical trial. Eur J Cardiothorac Surg 2000;17:580-6.
    • (2000) Eur J Cardiothorac Surg , vol.17 , pp. 580-586
    • Belboul, A.1    Löfgren, C.2    Storm, C.3    Jungbeck, M.4
  • 8
    • 34247269097 scopus 로고    scopus 로고
    • Perioperative blood transfusion and blood conservation in cardiac surgery: the Society of Thoracic Surgeons and The Society of Cardiovascular Anesthesiologists clinical practice guideline
    • Society of Thoracic Surgeons Blood Conservation Guideline Task Force, .
    • Society of Thoracic Surgeons Blood Conservation Guideline Task Force, Ferraris VA, Ferraris SP, etal. Perioperative blood transfusion and blood conservation in cardiac surgery: the Society of Thoracic Surgeons and The Society of Cardiovascular Anesthesiologists clinical practice guideline. Ann Thorac Surg 2007;83(Suppl. 5):S27-86.
    • (2007) Ann Thorac Surg , vol.83 , Issue.5 SUPPL.
    • Ferraris, V.A.1    Ferraris, S.P.2
  • 9
    • 78649576964 scopus 로고    scopus 로고
    • Evaluation of Capiox FX-05 oxygenator with an integrated arterial filter on trapping gaseous microemboli and pressure drop with open and closed purge line
    • Qiu F, Peng S, Kunselman A, Undar A. Evaluation of Capiox FX-05 oxygenator with an integrated arterial filter on trapping gaseous microemboli and pressure drop with open and closed purge line. Artif Organs 2010;34:1053-7.
    • (2010) Artif Organs , vol.34 , pp. 1053-1057
    • Qiu, F.1    Peng, S.2    Kunselman, A.3    Undar, A.4
  • 10
    • 41949116693 scopus 로고    scopus 로고
    • Arterial line filters ranked for gaseous micro-emboli separation performance: an in vitro study
    • Riley JB. Arterial line filters ranked for gaseous micro-emboli separation performance: an in vitro study. J Extra Corpor Technol 2008;40:21-6.
    • (2008) J Extra Corpor Technol , vol.40 , pp. 21-26
    • Riley, J.B.1
  • 11
    • 33746209060 scopus 로고    scopus 로고
    • Circulating endothelial cells demonstrate an attenuation of endothelial damage by minimizing the extracorporeal circulation
    • Skrabal CA, Choi YH, Kaminski A, etal. Circulating endothelial cells demonstrate an attenuation of endothelial damage by minimizing the extracorporeal circulation. J Thorac Cardiovasc Surg 2006;132:291-6.
    • (2006) J Thorac Cardiovasc Surg , vol.132 , pp. 291-296
    • Skrabal, C.A.1    Choi, Y.H.2    Kaminski, A.3
  • 12
    • 67649234446 scopus 로고    scopus 로고
    • Meta-analysis of randomized trials comparing the effectiveness of miniaturized versus conventional cardiopulmonary bypass in adult cardiac surgery
    • Biancari F, Rimpilainen R. Meta-analysis of randomized trials comparing the effectiveness of miniaturized versus conventional cardiopulmonary bypass in adult cardiac surgery. Heart 2009;95:964-9.
    • (2009) Heart , vol.95 , pp. 964-969
    • Biancari, F.1    Rimpilainen, R.2
  • 13
    • 79953269247 scopus 로고    scopus 로고
    • Mini-cardiopulmonary bypass impact on blood conservation strategy in coronary artery bypass grafting
    • Aal MA, El-Nahal N, Bakir BM, Fouda M. Mini-cardiopulmonary bypass impact on blood conservation strategy in coronary artery bypass grafting. Interact Cardiovasc Thorac Surg 2011;12:600-4.
    • (2011) Interact Cardiovasc Thorac Surg , vol.12 , pp. 600-604
    • Aal, M.A.1    El-Nahal, N.2    Bakir, B.M.3    Fouda, M.4
  • 14
    • 56349156090 scopus 로고    scopus 로고
    • Cardiopulmonary bypass duration is an independent predictor of morbidity and mortality after cardiac surgery
    • Salis S, Mazzanti VV, Merli G, etal. Cardiopulmonary bypass duration is an independent predictor of morbidity and mortality after cardiac surgery. J Cardiothorac Vasc Anesth 2008;22:814-22.
    • (2008) J Cardiothorac Vasc Anesth , vol.22 , pp. 814-822
    • Salis, S.1    Mazzanti, V.V.2    Merli, G.3
  • 15
    • 79959793231 scopus 로고    scopus 로고
    • Leukocyte filtration ameliorates the inflammatory response in patients with mild to moderate lung dysfunction
    • Onorati F, Santini F, Mariscalco G, etal. Leukocyte filtration ameliorates the inflammatory response in patients with mild to moderate lung dysfunction. Ann Thorac Surg 2011;92:111-21.
    • (2011) Ann Thorac Surg , vol.92 , pp. 111-121
    • Onorati, F.1    Santini, F.2    Mariscalco, G.3
  • 16
    • 0037332427 scopus 로고    scopus 로고
    • Evaluation of Mimesys phosphorylcholine (PC)-coated oxygenators during cardiopulmonary bypass in adults
    • Myers GJ, Johnstone DR, Swyer WJ, etal. Evaluation of Mimesys phosphorylcholine (PC)-coated oxygenators during cardiopulmonary bypass in adults. J Extra Corpor Technol 2003;35:6-12.
    • (2003) J Extra Corpor Technol , vol.35 , pp. 6-12
    • Myers, G.J.1    Johnstone, D.R.2    Swyer, W.J.3
  • 17
    • 35548953129 scopus 로고    scopus 로고
    • Insulin binding to the cardiopulmonary bypass biomaterials
    • Urban K, Redford D, Larson DF. Insulin binding to the cardiopulmonary bypass biomaterials. Perfusion 2007;22:207-10.
    • (2007) Perfusion , vol.22 , pp. 207-210
    • Urban, K.1    Redford, D.2    Larson, D.F.3
  • 18
    • 77950353860 scopus 로고    scopus 로고
    • Evaluation of blood components exposed to coated arterial filters in extracorporeal circuits
    • Hussaini BE, Treanor PR, Healey NA, etal. Evaluation of blood components exposed to coated arterial filters in extracorporeal circuits. Perfusion 2009;24:317-23.
    • (2009) Perfusion , vol.24 , pp. 317-323
    • Hussaini, B.E.1    Treanor, P.R.2    Healey, N.A.3
  • 19
    • 75749153220 scopus 로고    scopus 로고
    • Clinical evaluation of the Terumo Capiox FX05 hollow fiber oxygenator with integrated arterial line filter
    • Deptula J, Valleley M, Glogowski K, Detwiler J, Hammel J, Duncan K. Clinical evaluation of the Terumo Capiox FX05 hollow fiber oxygenator with integrated arterial line filter. J Extra Corpor Technol 2009;41:220-5.
    • (2009) J Extra Corpor Technol , vol.41 , pp. 220-225
    • Deptula, J.1    Valleley, M.2    Glogowski, K.3    Detwiler, J.4    Hammel, J.5    Duncan, K.6
  • 20
    • 79951972309 scopus 로고    scopus 로고
    • 2011 update to the Society of Thoracic Surgeons and the Society of Cardiovascular Anesthesiologists blood conservation clinical practice guidelines
    • Ferraris V, Brown JR, Despotis GJ, etal. 2011 update to the Society of Thoracic Surgeons and the Society of Cardiovascular Anesthesiologists blood conservation clinical practice guidelines. Ann Thorac Surg 2011;91:944-82.
    • (2011) Ann Thorac Surg , vol.91 , pp. 944-982
    • Ferraris, V.1    Brown, J.R.2    Despotis, G.J.3
  • 21
    • 33846652529 scopus 로고    scopus 로고
    • Effect of polymer coating (poly 2-methoxyethylacrylate) of the oxygenator on hemostatic markers during cardiopulmonary bypass in children
    • Eisses MJ, Geiduschek JM, Jonmarker C, Cohen GA, Chandler WL. Effect of polymer coating (poly 2-methoxyethylacrylate) of the oxygenator on hemostatic markers during cardiopulmonary bypass in children. J Cardiothorac Vasc Anesth 2007;21:28-34.
    • (2007) J Cardiothorac Vasc Anesth , vol.21 , pp. 28-34
    • Eisses, M.J.1    Geiduschek, J.M.2    Jonmarker, C.3    Cohen, G.A.4    Chandler, W.L.5
  • 22
    • 21244458098 scopus 로고    scopus 로고
    • Changes in platelet aggregation during cardiopulmonary bypass: comparison of poly-2-methoxyethylacrylate and heparin as a circuit coating material
    • Izuha H, Hattori M, Igari T, Wakamatsu D, Watanabe T, Yokoyama H. Changes in platelet aggregation during cardiopulmonary bypass: comparison of poly-2-methoxyethylacrylate and heparin as a circuit coating material. J Artif Organs 2005;8:41-6.
    • (2005) J Artif Organs , vol.8 , pp. 41-46
    • Izuha, H.1    Hattori, M.2    Igari, T.3    Wakamatsu, D.4    Watanabe, T.5    Yokoyama, H.6
  • 23
    • 77950362081 scopus 로고    scopus 로고
    • Outcomes comparison of 5 coated cardiopulmonary bypass circuits versus an uncoated control group of patients undergoing cardiac surgery
    • Marcoux J, Sohn N, McNair E, etal. Outcomes comparison of 5 coated cardiopulmonary bypass circuits versus an uncoated control group of patients undergoing cardiac surgery. Perfusion 2009;24:307-15.
    • (2009) Perfusion , vol.24 , pp. 307-315
    • Marcoux, J.1    Sohn, N.2    McNair, E.3
  • 24
    • 0034332701 scopus 로고    scopus 로고
    • Phosphorylcholine coating of extracorporeal circuits provides natural protection against blood activation by the material surface
    • De Somer F, Francois K, van Oeveren W, etal. Phosphorylcholine coating of extracorporeal circuits provides natural protection against blood activation by the material surface. Eur J Cardiothorac Surg 2000;18:602-6.
    • (2000) Eur J Cardiothorac Surg , vol.18 , pp. 602-606
    • De Somer, F.1    Francois, K.2    van Oeveren, W.3
  • 25
    • 0036147152 scopus 로고    scopus 로고
    • Phosphorylcholine coating offers natural platelet preservation during cardiopulmonary bypass
    • De Somer F, Van Belleghem Y, Caes F, etal. Phosphorylcholine coating offers natural platelet preservation during cardiopulmonary bypass. Perfusion 2002;17:39-44.
    • (2002) Perfusion , vol.17 , pp. 39-44
    • De Somer, F.1    Van Belleghem, Y.2    Caes, F.3
  • 26
    • 32644482947 scopus 로고    scopus 로고
    • Phosphorylcholine coating may limit thrombin formation during high-risk cardiac surgery: a randomized controlled trial
    • Pappalardo F, Della Valle P, Crescenzi G, etal. Phosphorylcholine coating may limit thrombin formation during high-risk cardiac surgery: a randomized controlled trial. Ann Thorac Surg 2006;81:886-91.
    • (2006) Ann Thorac Surg , vol.81 , pp. 886-891
    • Pappalardo, F.1    Della Valle, P.2    Crescenzi, G.3
  • 27
    • 68549132474 scopus 로고    scopus 로고
    • Post-arterial filter gaseous microemboli activity of five integral cardiotomy reservoirs during venting: an in vitro study
    • Myers GJ, Voorhees C, Haynes R, Eke B. Post-arterial filter gaseous microemboli activity of five integral cardiotomy reservoirs during venting: an in vitro study. J Extra Corpor Technol 2009;41:20-7.
    • (2009) J Extra Corpor Technol , vol.41 , pp. 20-27
    • Myers, G.J.1    Voorhees, C.2    Haynes, R.3    Eke, B.4
  • 28
    • 27144506167 scopus 로고    scopus 로고
    • Microbubbles: pathophysiology and clinical implications
    • Barak M, Katz Y. Microbubbles: pathophysiology and clinical implications. Chest 2005;128:2918-32.
    • (2005) Chest , vol.128 , pp. 2918-2932
    • Barak, M.1    Katz, Y.2
  • 29
    • 39049184851 scopus 로고    scopus 로고
    • In vitro evaluation of the air separation ability of four cardiovascular manufacturer extracorporeal circuit designs
    • Dickinson TA, Riley JB, Crowley JC, Zabetakis PM. In vitro evaluation of the air separation ability of four cardiovascular manufacturer extracorporeal circuit designs. J Extra Corpor Technol 2006;38:206-13.
    • (2006) J Extra Corpor Technol , vol.38 , pp. 206-213
    • Dickinson, T.A.1    Riley, J.B.2    Crowley, J.C.3    Zabetakis, P.M.4
  • 31
    • 77949903653 scopus 로고    scopus 로고
    • Statin prophylaxis and inflammatory mediators following cardiopulmonary bypass: a systematic review
    • Morgan C, Zappitelli M, Gill P. Statin prophylaxis and inflammatory mediators following cardiopulmonary bypass: a systematic review. Crit Care 2009;13:165-76.
    • (2009) Crit Care , vol.13 , pp. 165-176
    • Morgan, C.1    Zappitelli, M.2    Gill, P.3
  • 32
    • 67650561376 scopus 로고    scopus 로고
    • Extracorporeal circulation: the response of humoral and cellular elements of blood to extracorporeal circulation
    • Cohn L, ed. New York: McGraw-Hill
    • Hammon JW. Extracorporeal circulation: the response of humoral and cellular elements of blood to extracorporeal circulation. In: Cohn L, ed. Cardiac Surgery in the Adult. New York: McGraw-Hill, 2008;370-89.
    • (2008) Cardiac Surgery in the Adult , pp. 370-389
    • Hammon, J.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.