메뉴 건너뛰기




Volumn 95, Issue 12, 2009, Pages 964-969

Meta-analysis of randomised trials comparing the effectiveness of miniaturised versus conventional cardiopulmonary bypass in adult cardiac surgery

Author keywords

[No Author keywords available]

Indexed keywords

AORTA VALVE REPLACEMENT; ARTICLE; BLOOD TRANSFUSION; CARDIOPULMONARY BYPASS; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CORONARY ARTERY BYPASS SURGERY; HEART ATRIUM FIBRILLATION; HUMAN; INTENSIVE CARE UNIT; INTERMETHOD COMPARISON; LENGTH OF STAY; META ANALYSIS; MORTALITY; POSTOPERATIVE HEMORRHAGE; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL; RISK ASSESSMENT; STERNOTOMY; STROKE; SYSTEMATIC REVIEW; THROMBOCYTE COUNT; TREATMENT OUTCOME;

EID: 67649234446     PISSN: 13556037     EISSN: 1468201X     Source Type: Journal    
DOI: 10.1136/hrt.2008.158709     Document Type: Article
Times cited : (103)

References (35)
  • 1
    • 0036168128 scopus 로고    scopus 로고
    • Cardiopulmonary bypass induced inflammation: Pathophysiology and treatment. An update
    • DOI 10.1016/S1010-7940(01)01099-5, PII S1010794001010995
    • Paparella D, Yau TM, Young E. Cardiopulmonary bypass induced inflammation: pathophysiology and treatment. An update. Eur J Cardio-thorac Surg 2002;21:232-244 (Pubitemid 34135370)
    • (2002) European Journal of Cardio-thoracic Surgery , vol.21 , Issue.2 , pp. 232-244
    • Paparella, D.1    Yau, T.M.2    Young, E.3
  • 2
    • 0015420351 scopus 로고
    • Changes in serum complement and the immunoglobulins after cardiopulmonary bypass
    • Parker DJ, Cantrell G, Stroud R, et al. Changes in serum complement and the immunoglobulins after cardiopulmonary bypass. Br J Surg 1972;59:910-911
    • (1972) Br J Surg , vol.59 , pp. 910-911
    • Parker, D.J.1    Cantrell, G.2    Stroud, R.3
  • 3
    • 0033610734 scopus 로고    scopus 로고
    • Improving the quality of reports of metaanalyses of randomised controlled trials: The QUOROM statement. Quality of Reporting of Meta-analyses
    • Moher D, Cook DJ, Eastwood S, et al. Improving the quality of reports of metaanalyses of randomised controlled trials: the QUOROM statement. Quality of Reporting of Meta-analyses. Lancet 1999;354:1896-1900
    • (1999) Lancet , vol.354 , pp. 1896-1900
    • Moher, D.1    Cook, D.J.2    Eastwood, S.3
  • 4
    • 34247248388 scopus 로고    scopus 로고
    • A new PRECiSe (priming reduced extracorporeal circulation setup) minimizes the need for blood transfusions: First clinical results in coronary artery bypass grafting
    • DOI 10.1532/HSF98.20041065
    • Beholz S, Zheng L, Kessler M, et al. A new PRECiSe (priming reduced extracorporeal circulation setup) minimizes the need for blood transfusions: first clinical results in coronary artery bypass grafting. Heart Surg Forum 2005;8:E132-5. (Pubitemid 46621921)
    • (2005) Heart Surgery Forum , vol.8 , Issue.3 , pp. 160-163
    • Beholz, S.1    Zheng, L.2    Kessler, M.3    Rusche, M.4    Konertz, W.5
  • 6
    • 27544433546 scopus 로고    scopus 로고
    • Minimal versus conventional cardiopulmonary bypass: Assessment of intraoperative myocardial damage in coronary bypass surgery
    • DOI 10.1016/j.ejcts.2005.08.019, PII S1010794005006469
    • Immer FF, Pirovino C, Gygax E, et al. Minimal versus conventional cardiopulmonary bypass: assessment of intraoperative myocardial damage in coronary bypass surgery. Eur J Cardio-thorac Surg 2005;28:701-704 (Pubitemid 41539324)
    • (2005) European Journal of Cardio-thoracic Surgery , vol.28 , Issue.5 , pp. 701-704
    • Immer, F.F.1    Pirovino, C.2    Gygax, E.3    Englberger, L.4    Tevaearai, H.5    Carrel, T.P.6
  • 7
    • 29244455014 scopus 로고    scopus 로고
    • Comparison of conventional extracorporeal circulation and minimal extracorporeal circulation with respect to microbubbles and microembolic signals
    • DOI 10.1191/0267659105pf828oa
    • Perthel M, Kseibi S, Sagebiel F, et al. Comparison of conventional extracorporeal circulation and minimal extracorporeal circulation with respect to microbubbles and microembolic signals. Perfusion 2005;20:329-333 (Pubitemid 41824362)
    • (2005) Perfusion , vol.20 , Issue.6 , pp. 329-333
    • Perthel, M.1    Kseibi, S.2    Sagebiel, F.3    Alken, A.4    Laas, J.5
  • 9
    • 4444333445 scopus 로고    scopus 로고
    • Mini extracorporeal circuit for coronary artery bypass grafting: Initial clinical and biochemical results: a comparison with conventional and off-pump coronary artery bypass grafts concerning global oxidative stress and alveolar function
    • DOI 10.1191/0267659104pf746oa
    • van Boven WJ, Gerritsen WB, Waanders FG, et al. Mini extracorporeal circuit for coronary artery bypass grafting: initial clinical and biochemical results: a comparison with conventional and off-pump coronary artery bypass grafts concerning global oxidative stress and alveolar function. Perfusion 2004;19:239-246 (Pubitemid 39173455)
    • (2004) Perfusion , vol.19 , Issue.4 , pp. 239-246
    • Van Boven, W.-J.1    Gerritsen, W.B.2    Waanders, F.G.3    Haas, F.J.4    Aarts, L.P.5
  • 10
    • 19044363005 scopus 로고    scopus 로고
    • Pneumoproteins as a lung-specific biomarker of alveolar permeability in conventional on-pump coronary artery bypass graft surgery vs mini-extracorporeal circuit: A pilot study
    • DOI 10.1378/chest.127.4.1190
    • van Boven WJ, Gerritsen WB, Zanen P, et al. Pneumoproteins as a lung-specific biomarker of alveolar permeability in conventional on-pump coronary artery bypass graft surgery vs miniextracorporeal circuit: a pilot study. Chest 2005;127:1190-1195 (Pubitemid 46224280)
    • (2005) Chest , vol.127 , Issue.4 , pp. 1190-1195
    • Van Boven, W.-J.P.1    Gerritsen, W.B.M.2    Zanen, P.3    Grutters, J.C.4    Van Dongen, H.P.A.5    Bernard, A.6    Aarts, L.P.H.J.7
  • 12
    • 34250804398 scopus 로고    scopus 로고
    • Minimized cardiopulmonary bypass combined with a smart suction device: The future of cardiopulmonary bypass?
    • Stalder M, Gygax E, Immer FF, et al. Minimized cardiopulmonary bypass combined with a smart suction device: the future of cardiopulmonary bypass? Heart Surg Forum 2007;10:235-238
    • (2007) Heart Surg Forum , vol.10 , pp. 235-238
    • Stalder, M.1    Gygax, E.2    Immer, F.F.3
  • 13
    • 39149125144 scopus 로고    scopus 로고
    • Comparison of Mini-Cardiopulmonary Bypass System with Air-Purge Device to Conventional Bypass System
    • DOI 10.1016/j.athoracsur.2007.09.001, PII S0003497507018541
    • Ti LK, Goh BL, Wong PS, et al. Comparison of mini-cardiopulmonary bypass system with air-purge device to conventional bypass system. Ann Thorac Surg 2008;85:994-1000. (Pubitemid 351253491)
    • (2008) Annals of Thoracic Surgery , vol.85 , Issue.3 , pp. 994-1000
    • Ti, L.K.1    Goh, B.-L.2    Wong, P.-S.3    Ong, P.4    Goh, S.-G.5    Lee, C.-N.6
  • 14
    • 10044231710 scopus 로고    scopus 로고
    • Four years' experience with a miniaturized extracorporeal circulation system and its influence on clinical outcome
    • DOI 10.1111/j.1525-1594.2004.00030.x
    • Wiesenack C, Liebold A, Philipp A, et al. Four years' experience with a miniaturized extracorporeal circulation system and its influence on clinical outcome. Artif Organs 2004;28:1082-1088 (Pubitemid 39601202)
    • (2004) Artificial Organs , vol.28 , Issue.12 , pp. 1082-1088
    • Wiesenack, C.1    Liebold, A.2    Philipp, A.3    Ritzka, M.4    Koppenberg, J.5    Birnbaum, D.E.6    Keyl, C.7
  • 15
    • 33645348265 scopus 로고    scopus 로고
    • Mini-cardiopulmonary bypass system: Results of a prospective randomized study
    • Beghi C, Nicolini F, Agostinelli A, et al. Mini-cardiopulmonary bypass system: results of a prospective randomized study. Ann Thorac Surg 2006;81:1396-1400
    • (2006) Ann Thorac Surg , vol.81 , pp. 1396-1400
    • Beghi, C.1    Nicolini, F.2    Agostinelli, A.3
  • 16
    • 33646086738 scopus 로고    scopus 로고
    • Comparison of the inflammatory response between miniaturized and standard CPB circuits in aortic valve surgery
    • Bical OM, Fromes Y, Gaillard D, et al. Comparison of the inflammatory response between miniaturized and standard CPB circuits in aortic valve surgery. Eur J Cardiothorac Surg 2006;29:699-702.
    • (2006) Eur J Cardiothorac Surg , vol.29 , pp. 699-702
    • Bical, O.M.1    Fromes, Y.2    Gaillard, D.3
  • 18
    • 34248184985 scopus 로고    scopus 로고
    • Clinical advantages of using mini-bypass systems in terms of blood product use, postoperative bleeding and air entrainment: An in vivo clinical perspective
    • DOI 10.1016/j.ejcts.2007.01.065, PII S1010794007001479
    • Perthel M, El-Ayoubi L, Bendisch A, et al. Clinical advantages of using mini-bypass systems in terms of blood product use, postoperative bleeding and air entrainment: an in vivo clinical perspective. Eur J Cardio-thorac Surg 2007;31:1070-1075 (Pubitemid 46719957)
    • (2007) European Journal of Cardio-thoracic Surgery , vol.31 , Issue.6 , pp. 1070-1075
    • Perthel, M.1    El-Ayoubi, L.2    Bendisch, A.3    Laas, J.4    Gerigk, M.5
  • 20
    • 34748907894 scopus 로고    scopus 로고
    • New mini-extracorporeal circulation system (ECC.O) is a safe technique in coronary surgery
    • DOI 10.1080/14017430701446933, PII 779455610
    • Valtonen M, Vähäsilta T, Kaila-Keinänen T, et al. New mini-extracorporeal circulation system (ECC.O) is a safe technique in coronary surgery. Scand Cardiovasc J 2007;41:345-350 (Pubitemid 47470874)
    • (2007) Scandinavian Cardiovascular Journal , vol.41 , Issue.5 , pp. 345-350
    • Valtonen, M.1    Vahasilta, T.2    Kaila-Keinanen, T.3    Kuttila, K.4
  • 23
    • 34347370456 scopus 로고    scopus 로고
    • Reduction in blood product usage associated with routine use of mini bypass systems in extracorporeal circulation
    • DOI 10.1177/0267659106075660
    • Perthel M, Klingbeil A, El-Ayoubi L, et al. Reduction in blood product usage associated with routine use of mini bypass systems in extracorporeal circulation. Perfusion 2007;22:9.14. (Pubitemid 47018356)
    • (2007) Perfusion , vol.22 , Issue.1 , pp. 9-14
    • Perthel, M.1    Klingbeil, A.2    El-Ayoubi, L.3    Gerick, M.4    Laas, J.5
  • 24
    • 20544469491 scopus 로고    scopus 로고
    • Initial experience with a minimized extracorporeal bypass system: Is there a clinical benefit?
    • Abdel-Rahman U, Ozaslan F, Risteski PS, et al. Initial experience with a minimized extracorporeal bypass system: is there a clinical benefit? Ann Thorac Surg 2005;80:238-243
    • (2005) Ann Thorac Surg , vol.80 , pp. 238-243
    • Abdel-Rahman, U.1    Ozaslan, F.2    Risteski, P.S.3
  • 27
    • 4444242608 scopus 로고    scopus 로고
    • Aortic valve replacement with the minimal extracorporeal circulation (Jostra MECC System) versus standard cardiopulmonary bypass: A randomized prospective trial
    • DOI 10.1016/j.jtcvs.2004.01.041, PII S0022522304004945
    • Remadi JP, Rakotoarivello Z, Marticho P, et al. Aortic valve replacement with the minimal extracorporeal circulation (Jostra MECC System) versus standard cardiopulmonary bypass: a randomized prospective trial. J Thorac Cardiovasc Surg 2004;128:436-441 (Pubitemid 39194702)
    • (2004) Journal of Thoracic and Cardiovascular Surgery , vol.128 , Issue.3 , pp. 436-441
    • Remadi, J.P.1    Rakotoarivello, Z.2    Marticho, P.3    Trojette, F.4    Benamar, A.5    Poulain, H.6    Tribouilloy, C.7
  • 28
    • 33846426475 scopus 로고    scopus 로고
    • Minimizing cardiopulmonary bypass attenuates myocardial damage after cardiac surgery
    • DOI 10.1097/01.mat.0000249868.96923.1e, PII 0000248020070100000006
    • Skrabal CA, Steinhoff G, Liebold A. Minimizing cardiopulmonary bypass attenuates myocardial damage after cardiac surgery. ASAIO J 2007;53:32-35 (Pubitemid 46145489)
    • (2007) ASAIO Journal , vol.53 , Issue.1 , pp. 32-35
    • Skrabal, C.A.1    Steinhoff, G.2    Liebold, A.3
  • 29
    • 29144528843 scopus 로고    scopus 로고
    • Prospective randomized study comparing coronary artery bypass grafting with the new mini-extracorporeal circulation Jostra System or with a standard cardiopulmonary bypass
    • DOI 10.1016/j.ahj.2005.03.067, PII S0002870305005351
    • Remadi JP, Rakotoarivelo Z, Marticho P, et al. Prospective randomized study comparing coronary artery bypass grafting with the new mini-extracorporeal circulation Jostra System or with a standard cardiopulmonary bypass. Am Heart J 2006;151:198.e1-7 (Pubitemid 41815355)
    • (2006) American Heart Journal , vol.151 , Issue.1
    • Remadi, J.P.1    Rakotoarivelo, Z.2    Marticho, P.3    Benamar, A.4
  • 30
    • 33845414207 scopus 로고    scopus 로고
    • Preliminary experience with the mini-extracorporeal circulation system (Medtronic resting heart system)
    • DOI 10.1510/icvts.2006.129999
    • Kamiya H, Kofidis T, Haverich A, et al. Preliminary experience with the miniextracorporeal circulation system (Medtronic resting heart system). Interact Cardiovasc Thorac Surg 2006;5:680-682 (Pubitemid 44901220)
    • (2006) Interactive Cardiovascular and Thoracic Surgery , vol.5 , Issue.6 , pp. 680-682
    • Kamiya, H.1    Kofidis, T.2    Haverich, A.3    Klima, U.4
  • 31
    • 41349122085 scopus 로고    scopus 로고
    • Is there really a clinical benefit of using minimized extracorporeal circulation for coronary artery bypass grafting?
    • Schöttler J, Lutter G, Böning A, et al. Is there really a clinical benefit of using minimized extracorporeal circulation for coronary artery bypass grafting? Thorac Cardiovasc Surg 2008;56:65-70.
    • (2008) Thorac Cardiovasc Surg , vol.56 , pp. 65-70
    • Schöttler, J.1    Lutter, G.2    Böning, A.3
  • 33
    • 21244435975 scopus 로고    scopus 로고
    • Comparison of minimally invasive closed circuit extracorporeal circulation with conventional cardiopulmonary bypass and with off-pump technique in CABG patients: Selected parameters of coagulation and inflammatory system
    • DOI 10.1016/j.ejcts.2005.03.032, PII S1010794005002757
    • Wippermann J, Albes JM, Hartrumpf M, et al. Comparison of minimally invasive closed circuit extracorporeal circulation with conventional cardiopulmonary bypass and with off-pump technique in CABG patients: selected parameters of coagulation and inflammatory system. Eur J Cardio-thorac Surg 2005;28:127-132 (Pubitemid 40883946)
    • (2005) European Journal of Cardio-thoracic Surgery , vol.28 , Issue.1 , pp. 127-132
    • Wippermann, J.1    Albes, J.M.2    Hartrumpf, M.3    Kaluza, M.4    Vollandt, R.5    Bruhin, R.6    Wahlers, T.7
  • 34
    • 28344447156 scopus 로고    scopus 로고
    • Miniaturized cardiopulmonary bypass in coronary artery bypass surgery: Marginal impact on inflammation and coagulation but loss of safety margins
    • DOI 10.1016/j.athoracsur.2005.05.080, PII S0003497505009768
    • Nollert G, Schwabenland I, Maktav D, et al. Miniaturized cardiopulmonary bypass in coronary artery bypass surgery: marginal impact on inflammation and coagulation but loss of safety margins. Ann Thorac Surg 2005;80:2326-2332 (Pubitemid 41718082)
    • (2005) Annals of Thoracic Surgery , vol.80 , Issue.6 , pp. 2326-2332
    • Nollert, G.1    Schwabenland, I.2    Maktav, D.3    Kur, F.4    Christ, F.5    Fraunberger, P.6    Reichart, B.7    Vicol, C.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.