메뉴 건너뛰기




Volumn 173, Issue , 2012, Pages 927-934

Electrical characteristics analysis of various cancer cells using a microfluidic device based on single-cell impedance measurement

Author keywords

Cancer cell; Cell impedance measurement; Electrical analysis; Single cell trap

Indexed keywords

BIOMEDICAL APPLICATIONS; CANCER CELL LINES; CANCER CELLS; CELL IMPEDANCE; CELL MEMBRANE CAPACITANCE; CULTURE MEDIUM; ELECTRICAL ANALYSIS; ELECTRICAL CHARACTERISTIC; ELECTRICAL IMPEDANCE SPECTROSCOPY; ELECTROCHEMICAL MATERIALS; HELA CELL; IMPEDANCE ANALYZER; IMPEDANCE MEASUREMENT; IMPEDANCE SPECTRUM; IONIC CHANNELS; MCF-7 CELLS; MICRO-FLUIDIC DEVICES; OPERATING VOLTAGE; SINGLE-CELL TRAP; VOLTAGE RANGES;

EID: 84867080000     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2012.06.046     Document Type: Article
Times cited : (105)

References (31)
  • 4
    • 0027573677 scopus 로고
    • Impedance spectroscopy of human erythrocytes: System calibration and nonlinear modeling
    • J.Z. Bao, C.C. David, and R.E. Schmukler Impedance spectroscopy of human erythrocytes: system calibration and nonlinear modeling IEEE Transactions on Biomedical Engineering 40 4 1993 364 378
    • (1993) IEEE Transactions on Biomedical Engineering , vol.40 , Issue.4 , pp. 364-378
    • Bao, J.Z.1    David, C.C.2    Schmukler, R.E.3
  • 5
    • 0038460907 scopus 로고    scopus 로고
    • Biphasic effects of 17-β-estradiol on expression of occludin and transendothelial resistance and paracellular permeability in human vascular endothelial cells
    • L. Ye, T.A. Martin, C. Parr, G.M. Harrison, R.E. Mansel, and W.G. Jiang Biphasic effects of 17-β-estradiol on expression of occludin and transendothelial resistance and paracellular permeability in human vascular endothelial cells Journal of Cellular Physiology 196 2003 362 369
    • (2003) Journal of Cellular Physiology , vol.196 , pp. 362-369
    • Ye, L.1    Martin, T.A.2    Parr, C.3    Harrison, G.M.4    Mansel, R.E.5    Jiang, W.G.6
  • 6
    • 3142711824 scopus 로고    scopus 로고
    • Modification of endothelial cell functions by Hantaan virus infection: Prolonged hyper-permeability induced by TNF-alpha of hantaan virus-infected endothelial cell monolayers
    • M. Niikura, A. Maeda, T. Ikegami, M. Saijo, I. Kurane, and S. Morikawa Modification of endothelial cell functions by Hantaan virus infection: prolonged hyper-permeability induced by TNF-alpha of hantaan virus-infected endothelial cell monolayers Archives of Virology 149 2004 1279 1292
    • (2004) Archives of Virology , vol.149 , pp. 1279-1292
    • Niikura, M.1    Maeda, A.2    Ikegami, T.3    Saijo, M.4    Kurane, I.5    Morikawa, S.6
  • 7
    • 33846043580 scopus 로고    scopus 로고
    • Design and preliminary evaluation of a portable device for measurement of bioimpedance spectroscopy
    • Y. Yang, J. Wang, G. Yu, F. Niu, and P. He Design and preliminary evaluation of a portable device for measurement of bioimpedance spectroscopy Physiological Measurement 27 2006 1293 1310
    • (2006) Physiological Measurement , vol.27 , pp. 1293-1310
    • Yang, Y.1    Wang, J.2    Yu, G.3    Niu, F.4    He, P.5
  • 8
    • 0038094487 scopus 로고    scopus 로고
    • A disposable microbial based biosensor for quality control in milk
    • N. Verma, and M. Singh A disposable microbial based biosensor for quality control in milk Biosensors and Bioelectronics 18 2003 1219 1224
    • (2003) Biosensors and Bioelectronics , vol.18 , pp. 1219-1224
    • Verma, N.1    Singh, M.2
  • 9
    • 0034771453 scopus 로고    scopus 로고
    • A MEMS based amperometric detector for E. coli bacteria using self-assembled monolayers
    • J. Gau Jr., E.H. Lan, B. Dunn, C.-M. Ho, and J.C.S. Woo A MEMS based amperometric detector for E. coli bacteria using self-assembled monolayers Biosensors and Bioelectronics 16 2001 745 755
    • (2001) Biosensors and Bioelectronics , vol.16 , pp. 745-755
    • Gau, Jr.J.1    Lan, E.H.2    Dunn, B.3    Ho, C.-M.4    Woo, J.C.S.5
  • 11
    • 0001459005 scopus 로고
    • Toxic? Cells can tell
    • FEBRUARY
    • I. Giaever, and C.R. Keese Toxic? Cells can tell Chemtech February 1992 116 125
    • (1992) Chemtech , pp. 116-125
    • Giaever, I.1    Keese, C.R.2
  • 13
    • 3142726971 scopus 로고    scopus 로고
    • Dielectric spectroscopy in a micromachined flow cytometer: Theoretical and practical considerations
    • S. Gawad, K. Cheung, U. Seger, A. Bertsch, and P. Renaud Dielectric spectroscopy in a micromachined flow cytometer: theoretical and practical considerations Lab Chip 4 2004 241 251
    • (2004) Lab Chip , vol.4 , pp. 241-251
    • Gawad, S.1    Cheung, K.2    Seger, U.3    Bertsch, A.4    Renaud, P.5
  • 15
    • 0141929485 scopus 로고    scopus 로고
    • Dielectrophoresis separation and transportation of cells and bioparticles on microfabricated chips
    • J. Xu, L. Wu, M. Huang, W. Yang, J. Cheng, and X. Wang Dielectrophoresis separation and transportation of cells and bioparticles on microfabricated chips MicroTAS 2001 565 566
    • (2001) MicroTAS , pp. 565-566
    • Xu, J.1    Wu, L.2    Huang, M.3    Yang, W.4    Cheng, J.5    Wang, X.6
  • 17
    • 33748848866 scopus 로고    scopus 로고
    • Electrothermal flows generated by alternating and rotating electric fields in microsystems
    • A. Gonzalez, A. Ramos, H. Morgan, N.G. Green, and A. Castellanos Electrothermal flows generated by alternating and rotating electric fields in microsystems Journal of Fluid Mechanics 564 2006 415 433
    • (2006) Journal of Fluid Mechanics , vol.564 , pp. 415-433
    • Gonzalez, A.1    Ramos, A.2    Morgan, H.3    Green, N.G.4    Castellanos, A.5
  • 19
    • 58149234842 scopus 로고    scopus 로고
    • Impedance studies of bio-behavior and chemosensitivity of cancer cells by micro-electrode arrays
    • Q. Liu, J. Yu, L. Xiao, J.C.O. Tang, Y. Zhang, P. Wang, and M. Yang Impedance studies of bio-behavior and chemosensitivity of cancer cells by micro-electrode arrays Biosensors and Bioelectronics 24 2009 1305 1310
    • (2009) Biosensors and Bioelectronics , vol.24 , pp. 1305-1310
    • Liu, Q.1    Yu, J.2    Xiao, L.3    Tang, J.C.O.4    Zhang, Y.5    Wang, P.6    Yang, M.7
  • 21
    • 77954665560 scopus 로고    scopus 로고
    • Electrical properties of breast cancer cells from impedance measurement of cell suspensions
    • G. Qiao, W. Duan, A. Sinclair, and W.W. Wang Electrical properties of breast cancer cells from impedance measurement of cell suspensions Journal of Physics 224 2010 012081
    • (2010) Journal of Physics , vol.224 , pp. 012081
    • Qiao, G.1    Duan, W.2    Sinclair, A.3    Wang, W.W.4
  • 22
    • 0025360716 scopus 로고
    • Frequency domain analysis of membrane capacitance of cultured cells (HeLa and myeloma) using the micropipette technique
    • K. Asami, Y. Takahashi, and S. Takashima Frequency domain analysis of membrane capacitance of cultured cells (HeLa and myeloma) using the micropipette technique Biophysical Journal 58 1990 143 148
    • (1990) Biophysical Journal , vol.58 , pp. 143-148
    • Asami, K.1    Takahashi, Y.2    Takashima, S.3
  • 23
    • 2942720416 scopus 로고    scopus 로고
    • Highly ordered heterogeneous ion exchange membranes
    • Y. Oren, V. Freger, and C. Linder Highly ordered heterogeneous ion exchange membranes Journal of Membrane Science 239 2004 17 26
    • (2004) Journal of Membrane Science , vol.239 , pp. 17-26
    • Oren, Y.1    Freger, V.2    Linder, C.3
  • 24
    • 21244432458 scopus 로고    scopus 로고
    • Dielectrophoretic taps for single-particle patterning
    • A. Rosenthal, and J. Voldman Dielectrophoretic taps for single-particle patterning Biophysical Journal 88 2005 2193 2205
    • (2005) Biophysical Journal , vol.88 , pp. 2193-2205
    • Rosenthal, A.1    Voldman, J.2
  • 25
    • 67650086643 scopus 로고    scopus 로고
    • Single-cell trapping utilizing negative dielectrophoretic quadrupole and microwell electrodes
    • L.S. Jang, P.H. Huang, and K.C. Lan Single-cell trapping utilizing negative dielectrophoretic quadrupole and microwell electrodes Biosensors and Bioelectronics 24 2009 3637 3644
    • (2009) Biosensors and Bioelectronics , vol.24 , pp. 3637-3644
    • Jang, L.S.1    Huang, P.H.2    Lan, K.C.3
  • 26
    • 78650597808 scopus 로고    scopus 로고
    • Integration of single-cell trapping and impedance measurement utilizing microwell electrodes
    • K.C. Lan, and L.S. Jang Integration of single-cell trapping and impedance measurement utilizing microwell electrodes Biosensors and Bioelectronics 26 2011 2025 2031
    • (2011) Biosensors and Bioelectronics , vol.26 , pp. 2025-2031
    • Lan, K.C.1    Jang, L.S.2
  • 28
    • 4544272295 scopus 로고    scopus 로고
    • Simulation of microelectrode impedance changes due to cell growth
    • X. Huang, D.D. Nguyen, D.W. Greve, and M.M. Domach Simulation of microelectrode impedance changes due to cell growth IEEE Sensors Journal 4 5 2004 576 583
    • (2004) IEEE Sensors Journal , vol.4 , Issue.5 , pp. 576-583
    • Huang, X.1    Nguyen, D.D.2    Greve, D.W.3    Domach, M.M.4
  • 29
    • 41749089376 scopus 로고    scopus 로고
    • Analytical and numerical modeling methods for impedance analysis of single cells on-chip
    • T. Sun, N.G. Green, and H. Morgan Analytical and numerical modeling methods for impedance analysis of single cells on-chip Nano 3 1 2007 55 63
    • (2007) Nano , vol.3 , Issue.1 , pp. 55-63
    • Sun, T.1    Green, N.G.2    Morgan, H.3
  • 31
    • 34548319265 scopus 로고    scopus 로고
    • Microfluidic device for cell capture and impedance measurement
    • L.S. Jang, and M.H. Wang Microfluidic device for cell capture and impedance measurement Biomedical Microdevices 9 2007 737 743
    • (2007) Biomedical Microdevices , vol.9 , pp. 737-743
    • Jang, L.S.1    Wang, M.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.