메뉴 건너뛰기




Volumn 27, Issue 12, 2006, Pages

Design and preliminary evaluation of a portable device for the measurement of bioimpedance spectroscopy

Author keywords

Bioimpedance spectroscopy; Gain phase detector; Magnitude ratio and phase difference detection method; Sweep frequency measurements; Three reference calibration algorithm

Indexed keywords

CALIBRATION; PORTABLE EQUIPMENT; PRODUCT DESIGN; SIGNAL DETECTION; SPECTROSCOPY;

EID: 33846043580     PISSN: 09673334     EISSN: 13616579     Source Type: Journal    
DOI: 10.1088/0967-3334/27/12/004     Document Type: Article
Times cited : (82)

References (27)
  • 1
    • 9644268889 scopus 로고    scopus 로고
    • Skin cancer identification using multifrequency electrical impedance-a potential screening tool
    • Åberg P, Nicander I, Hansson J, Geladi P, Holmgren U and Ollmar S 2004 Skin cancer identification using multifrequency electrical impedance-a potential screening tool IEEE Trans. Biomed. Eng. 51 2097-102
    • (2004) IEEE Trans. Biomed. Eng. , vol.51 , Issue.12 , pp. 2097-2102
    • Åberg, P.1    Nicander, I.2    Hansson, J.3    Geladi, P.4    Holmgren, U.5    Ollmar, S.6
  • 2
    • 33846105801 scopus 로고    scopus 로고
    • AD8302 Data Sheet 2002 Analog Devices, Corporate Headquarters, One Technology Way, PO Box 9106, Norwood, MA 02062-9106, USA (available in PDF format from http://www.analog.com/UploadedFiles/Data_Sheets/797075782AD8302_a. pdf)
    • (2002)
  • 3
    • 33846099893 scopus 로고    scopus 로고
    • AD9833 Data Sheet 2003 Analog Devices, Corporate Headquarters, One Technology Way, PO Box 9106, Norwood, MA 02062-9106, USA (available in PDF format from http://www.analog.com/UploadedFiles/Data_Sheets/ 37150134474160AD9833_a.pdf)
    • (2003)
  • 4
    • 0027573677 scopus 로고
    • Impedance system spectroscopy of human erythrocytes calibration and nonlinear modeling
    • Bao J-Z, Davis C C and Schmukler R E 1993 Impedance system spectroscopy of human erythrocytes calibration and nonlinear modeling IEEE Trans. Biomed. Eng. 40 364-78
    • (1993) IEEE Trans. Biomed. Eng. , vol.40 , Issue.4 , pp. 364-378
    • Bao, J.-Z.1    Davis, C.C.2    Schmukler, R.E.3
  • 5
    • 0028263483 scopus 로고
    • A wide-band AC-coupled current source for electrical impedance tomography
    • Bragos R, Rosell J and Riu P 1994 A wide-band AC-coupled current source for electrical impedance tomography Physiol. Meas. 15 A91-A99
    • (1994) Physiol. Meas. , vol.15
    • Bragos, R.1    Rosell, J.2    Riu, P.3
  • 6
    • 22944488889 scopus 로고    scopus 로고
    • Differential synchronous emodulator for modulating sensors and impedance measurements
    • Casanella R, Casas O and Pallàs-Areny R 2005 Differential synchronous emodulator for modulating sensors and impedance measurements Meas. Sci. Technol. 16 1637-43
    • (2005) Meas. Sci. Technol. , vol.16 , Issue.8 , pp. 1637-1643
    • Casanella, R.1    Casas, O.2    Pallàs-Areny, R.3
  • 7
    • 1842580077 scopus 로고    scopus 로고
    • Accurate gain/phase measurement at radio frequencies up to 2.5 GHz
    • Cowles J and Gilbert B 2001 Accurate gain/phase measurement at radio frequencies up to 2.5 GHz Analog Dialogue 35 (October) (available in PDF format from http://www.analog.com/library/analogDialogue/archives/35-05/AD8302/AD8302. pdf)
    • (2001) Analog Dialogue , vol.35 , Issue.OCTOBER
    • Cowles, J.1    Gilbert, B.2
  • 9
    • 0032742068 scopus 로고    scopus 로고
    • The electric resistivity of human tissues (100 Hz-10 MHz): A meta-analysis of review studies
    • Faes T J C, Meij H A v d, Munck J C d and Heethaar R M 1999 The electric resistivity of human tissues (100 Hz-10 MHz): a meta-analysis of review studies Physiol. Meas. 20 R1-R10
    • (1999) Physiol. Meas. , vol.20 , Issue.4
    • Faes, T.J.C.1    Meij, H.A.V.D.2    Munck, J.C.D.3    Heethaar, R.M.4
  • 10
    • 33846076983 scopus 로고    scopus 로고
    • INA163 Data Sheet 2000 Texas Instruments, Company Headquarters, 12500 TI Boulevard, PO Box 660199, Dallas, TX 75243-4136, USA (available in PDF format from http://www-s.ti.com/sc/ds/ina163.pdf)
    • (2000)
  • 11
    • 0344925584 scopus 로고    scopus 로고
    • Algorithm for tissue ischemia estimation based on electrical impedance spectroscopy
    • Kun S, Ristic B, Peura R A and Dunn R M 2003 Algorithm for tissue ischemia estimation based on electrical impedance spectroscopy IEEE Trans. Biomed. Eng. 50 1352-9
    • (2003) IEEE Trans. Biomed. Eng. , vol.50 , Issue.12 , pp. 1352-1359
    • Kun, S.1    Ristic, B.2    Peura, R.A.3    Dunn, R.M.4
  • 12
    • 0029842404 scopus 로고    scopus 로고
    • Fast EIT data acquisition system with active electrodes and its application to cardiac imaging
    • Li J H, Joppek C and Faust U 1996 Fast EIT data acquisition system with active electrodes and its application to cardiac imaging Physiol. Meas. 17 A25-A32
    • (1996) Physiol. Meas. , vol.17
    • Li, J.H.1    Joppek, C.2    Faust, U.3
  • 13
    • 0345148328 scopus 로고    scopus 로고
    • Accuracy improvement of impedance measurements by using the self-calibration
    • Liu J-G, Frühauf U and Schönecker A 1999 Accuracy improvement of impedance measurements by using the self-calibration Measurement 25 213-25
    • (1999) Measurement , vol.25 , Issue.3 , pp. 213-225
    • Liu, J.-G.1    Frühauf, U.2    Schönecker, A.3
  • 14
    • 33846059256 scopus 로고    scopus 로고
    • LTC1560-1 Data Sheet Linear Technology Corporate Headquarters 1630 McCarthy Blvd. Milpitas, CA 95035-7417, USA (available in PDF format from http://www.linear.com/pc/downloadDocument.do?navId=H0,C1,C1154,C1008,C1148, P1547,D3990)
  • 15
    • 0141918773 scopus 로고    scopus 로고
    • Validity and accuracy of regional bioelectrical impedance devices to determine whole-body fatness
    • Lukaski H C and Siders W A 2003 Validity and accuracy of regional bioelectrical impedance devices to determine whole-body fatness Nutrition 19 851-7
    • (2003) Nutrition , vol.19 , Issue.10 , pp. 851-857
    • Lukaski, H.C.1    Siders, W.A.2
  • 16
    • 23844493206 scopus 로고    scopus 로고
    • Monitoring of lung edema using focused impedance spectroscopy: A feasibility study
    • Mayer M, Brunner P, Merwa R and Scharfetter H 2005 Monitoring of lung edema using focused impedance spectroscopy: a feasibility study Physiol. Meas. 26 185-92
    • (2005) Physiol. Meas. , vol.26 , Issue.3 , pp. 185-192
    • Mayer, M.1    Brunner, P.2    Merwa, R.3    Scharfetter, H.4
  • 17
    • 0033857273 scopus 로고    scopus 로고
    • A method for bio-electrical impedance analysis based on a step-voltage response
    • Neves C E B and Souza M N 2000 A method for bio-electrical impedance analysis based on a step-voltage response Physiol. Meas. 21 395-408
    • (2000) Physiol. Meas. , vol.21 , Issue.3 , pp. 395-408
    • Neves, C.E.B.1    Souza, M.N.2
  • 18
    • 0029153921 scopus 로고
    • Tissue impedance spectra and the appropriate frequencies for EIT
    • Osypka M and Gersing E 1995 Tissue impedance spectra and the appropriate frequencies for EIT Physiol. Meas. 16 A49-A55
    • (1995) Physiol. Meas. , vol.16
    • Osypka, M.1    Gersing, E.2
  • 19
    • 0027731458 scopus 로고
    • Bioelectric impedance measurements using synchronous sampling
    • Pallas-Areny R and Webster J G 1993 Bioelectric impedance measurements using synchronous sampling IEEE Trans. Biomed. Eng. 40 824-9
    • (1993) IEEE Trans. Biomed. Eng. , vol.40 , Issue.8 , pp. 824-829
    • Pallas-Areny, R.1    Webster, J.G.2
  • 20
    • 0029823582 scopus 로고    scopus 로고
    • Broadband quasi-differential multifrequency electrical impedance imaging system
    • Riu P J, Bragós R and Rosell J 1996 Broadband quasi-differential multifrequency electrical impedance imaging system Physiol. Meas. 17 A39
    • (1996) Physiol. Meas. , vol.17
    • Riu, P.J.1    Bragós, R.2    Rosell, J.3
  • 21
    • 33846117423 scopus 로고    scopus 로고
    • RJL Systems Inc. 2005 website http://www.rjlsystems.com/products/ more_desktop.shtml
    • (2005)
  • 22
    • 0038100605 scopus 로고    scopus 로고
    • Current source design for electrical impedance tomography
    • Ross A S, Saulnier G J, Newell J C and Isaacson D 2003 Current source design for electrical impedance tomography Physiol. Meas. 24 509-16
    • (2003) Physiol. Meas. , vol.24 , Issue.2 , pp. 509-516
    • Ross, A.S.1    Saulnier, G.J.2    Newell, J.C.3    Isaacson, D.4
  • 23
    • 0031807043 scopus 로고    scopus 로고
    • A model of artefacts produced by stray capacitance during whole body or segmental bioimpedance spectroscopy
    • Scharfettery H, Hartingery P, Hinghofer-Szalkayz H and Hutteny H 1998 A model of artefacts produced by stray capacitance during whole body or segmental bioimpedance spectroscopy Physiol. Meas. 19 247-61
    • (1998) Physiol. Meas. , vol.19 , Issue.2 , pp. 247-261
    • Scharfettery, H.1    Hartingery, P.2    Hinghofer-Szalkayz, H.3    Hutteny, H.4
  • 25
    • 1342311379 scopus 로고    scopus 로고
    • Feasibility studies of electrical impedance spectroscopy for early tumor detection in rats
    • Skourou C, Hoopes P J, Strawbridge R R and Paulsen K D 2004 Feasibility studies of electrical impedance spectroscopy for early tumor detection in rats Physiol. Meas. 25 335-46
    • (2004) Physiol. Meas. , vol.25 , Issue.1 , pp. 335-346
    • Skourou, C.1    Hoopes, P.J.2    Strawbridge R, R.3    Paulsen, K.D.4
  • 26
    • 33746787772 scopus 로고    scopus 로고
    • A practical approach to electrode-skin impedance unbalance measurement
    • Spinelli E M, Mayosky M A and Pallàs-Areny R 2006 A practical approach to electrode-skin impedance unbalance measurement IEEE Trans. Biomed. Eng. 53 1451-3
    • (2006) IEEE Trans. Biomed. Eng. , vol.53 , Issue.7 , pp. 1451-1453
    • Spinelli, E.M.1    Mayosky, M.A.2    Pallàs-Areny, R.3
  • 27
    • 0027692797 scopus 로고
    • The four-electrode resistivity technique in anisotropic media: Theoretical analysis and application on myocardial tissue in vivo
    • Steendijk P, Mur G, Velde E T V D and Baan J 1993 The four-electrode resistivity technique in anisotropic media: theoretical analysis and application on myocardial tissue in vivo IEEE Trans. Biomed. Eng. 40 1138-48
    • (1993) IEEE Trans. Biomed. Eng. , vol.40 , Issue.11 , pp. 1138-1148
    • Steendijk, P.1    Mur, G.2    Velde, E.T.V.D.3    Baan, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.