메뉴 건너뛰기




Volumn 13, Issue 5, 2012, Pages 12-23

Comparing dose in the build-up region between compensator-and MLC-based IMRT

Author keywords

Build up dose; Compensator; IMRT; MLC; Monte carlo

Indexed keywords


EID: 84867058416     PISSN: None     EISSN: 15269914     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (8)

References (18)
  • 1
    • 3042559687 scopus 로고    scopus 로고
    • Comparative skin dose measurement in the treatment of anal canal cancer: conventional versus conformal therapy
    • Devic S, Hegyi G, Vuong T, Muanza T, Podgorsak EB. Comparative skin dose measurement in the treatment of anal canal cancer: conventional versus conformal therapy. Med Phys. 2004;31(6):1316-21.
    • (2004) Med Phys , vol.31 , Issue.6 , pp. 1316-1321
    • Devic, S.1    Hegyi, G.2    Vuong, T.3    Muanza, T.4    Podgorsak, E.B.5
  • 2
    • 14544282452 scopus 로고    scopus 로고
    • De Wagter C, VanEsch A, Duthoy W, Depuydt T DeNeve W. Comparison of build-up dose between Elekta and Varian linear accelerators for high-energy photon beams using radiochromic film and clinical implications for IMRT head and neck treatments
    • Paelinck L, De Wagter C, VanEsch A, Duthoy W, Depuydt T, DeNeve W. Comparison of build-up dose between Elekta and Varian linear accelerators for high-energy photon beams using radiochromic film and clinical implications for IMRT head and neck treatments. Phys Med Biol. 2005;50(3):413-28.
    • (2005) Phys Med Biol , vol.50 , Issue.3 , pp. 413-428
    • Paelinck, L.1
  • 3
    • 34249320540 scopus 로고    scopus 로고
    • Effects of prolongation of overall treatment time due to unplanned interruptions during radiotherapy of different tumor sites and practical methods for compensation
    • Bese NS, Hendry J, Jeremic B. Effects of prolongation of overall treatment time due to unplanned interruptions during radiotherapy of different tumor sites and practical methods for compensation. Int J Radiat Oncol Biol Phys. 2007;68(3):654-61.
    • (2007) Int J Radiat Oncol Biol Phys , vol.68 , Issue.3 , pp. 654-661
    • Bese, N.S.1    Hendry, J.2    Jeremic, B.3
  • 4
    • 23944493580 scopus 로고    scopus 로고
    • Evaluation of surface and build-up region dose for intensity-modulated radiation therapy in head and neck cancer
    • Chung H, Jin H, Dempsey JF, et al. Evaluation of surface and build-up region dose for intensity-modulated radiation therapy in head and neck cancer. Med Phys. 2005;32(8):2682-89.5.
    • (2005) Med Phys , vol.32 , Issue.8 , pp. 2682-2689
    • Chung, H.1    Jin, H.2    Dempsey, J.F.3
  • 5
    • 0142028261 scopus 로고    scopus 로고
    • The physical basis of IMRT and inverse planning
    • Webb S. The physical basis of IMRT and inverse planning. Br J Radiol. 2003;76(910):678-89.
    • (2003) Br J Radiol , vol.76 , Issue.910 , pp. 678-689
    • Webb, S.1
  • 6
    • 0019947658 scopus 로고
    • Contamination of a 15-MV photon beam by electrons and scattered photons
    • Mackie TR and Scrimger JW. Contamination of a 15-MV photon beam by electrons and scattered photons. Radiology. 1982;144(2):403-09.
    • (1982) Radiology , vol.144 , Issue.2 , pp. 403-409
    • Mackie, T.R.1    Scrimger, J.W.2
  • 7
    • 0023907265 scopus 로고
    • Skin dose near compensating filters in radiotherapy
    • Thomas SJ and Bruce G. Skin dose near compensating filters in radiotherapy. Phys Med Biol. 1988;33(6):703-10.
    • (1988) Phys Med Biol , vol.33 , Issue.6 , pp. 703-710
    • Thomas, S.J.1    Bruce, G.2
  • 8
    • 0025021187 scopus 로고
    • Measurement of dose in the buildup region using fixed-separation plane-parallel ionization chambers
    • Gerbi BJ and Khan FM. Measurement of dose in the buildup region using fixed-separation plane-parallel ionization chambers. Med Phys. 1990;17(1):17-26.
    • (1990) Med Phys , vol.17 , Issue.1 , pp. 17-26
    • Gerbi, B.J.1    Khan, F.M.2
  • 9
    • 0022601347 scopus 로고
    • Fluence perturbation in photon beams under nonequilibrium conditions
    • Nilsson B and Montelius A. Fluence perturbation in photon beams under nonequilibrium conditions. Med Phys. 1986;13(2):191-95.
    • (1986) Med Phys , vol.13 , Issue.2 , pp. 191-195
    • Nilsson, B.1    Montelius, A.2
  • 10
    • 0016652027 scopus 로고
    • Oliver GD Jr Build-up region of megavoltage photon radiation sources
    • Velkley DE, Manson DJ, Purdy JA, Oliver GD Jr. Build-up region of megavoltage photon radiation sources. Med Phys. 1975;2(1):14-19.
    • (1975) Med Phys , vol.2 , Issue.1 , pp. 14-19
    • Velkley, D.E.1    Manson, D.J.2    Purdy, J.A.3
  • 11
    • 0026695986 scopus 로고
    • Design of parallel plate ion chambers for buildup measurements in megavoltage photon beams
    • Rawlinson JA, Arlen D, Newcombe D. Design of parallel plate ion chambers for buildup measurements in megavoltage photon beams. Med Phys. 1992;19(3):641-48.
    • (1992) Med Phys , vol.19 , Issue.3 , pp. 641-648
    • Rawlinson, J.A.1    Arlen, D.2    Newcombe, D.3
  • 12
    • 33645519422 scopus 로고    scopus 로고
    • Accurate skin dose measurements using radiochromic film in clinical applications
    • Devic S, Seuntjens J, Abdel-Rahman W, et al. Accurate skin dose measurements using radiochromic film in clinical applications. Med Phys. 2006;33(4):1116-24.
    • (2006) Med Phys , vol.33 , Issue.4 , pp. 1116-1124
    • Devic, S.1    Seuntjens, J.2    Abdel-Rahman, W.3
  • 13
    • 18844366606 scopus 로고    scopus 로고
    • Characterization of electron contamination in megavoltage photon beams
    • Lopez Medina A, Teijeiro A, Garcia J, et al. Characterization of electron contamination in megavoltage photon beams. Med Phys. 2005;32(5):1281-92.
    • (2005) Med Phys , vol.32 , Issue.5 , pp. 1281-1292
    • Lopez Medina, A.1    Teijeiro, A.2    Garcia, J.3
  • 14
    • 0024416182 scopus 로고
    • Surface dose measurements in clinical photon beams
    • Nilsson B and Sorcini B. Surface dose measurements in clinical photon beams. Acta Oncol. 1989;28(4):537-42.
    • (1989) Acta Oncol , vol.28 , Issue.4 , pp. 537-542
    • Nilsson, B.1    Sorcini, B.2
  • 15
    • 0034104708 scopus 로고    scopus 로고
    • Accurate condensed history Monte Carlo simulation of electron transport
    • Kawrakow I. Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version. Med Phys. 2000;27(3):485-98.
    • (2000) I. EGSnrc, the new EGS4 version. Med Phys. , vol.27 , Issue.3 , pp. 485-498
    • Kawrakow, I.1
  • 17
    • 0001232892 scopus 로고
    • A survey of depth dose data
    • Mayneord WV and Lamerton LF. A survey of depth dose data. Br J Radiol. 1941;14(164):255-64.
    • (1941) Br J Radiol , vol.14 , Issue.164 , pp. 255-264
    • Mayneord, W.V.1    Lamerton, L.F.2
  • 18
    • 79960524770 scopus 로고    scopus 로고
    • Commissoning compensator-based IMRT on the Pinnacle treatment planning system
    • Opp D, Forster K, Feygelman V. Commissoning compensator-based IMRT on the Pinnacle treatment planning system. J Appl Clin Med Phy. 2011;12(2):310-25.
    • (2011) J Appl Clin Med Phy , vol.12 , Issue.2 , pp. 310-325
    • Opp, D.1    Forster, K.2    Feygelman, V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.