-
1
-
-
0036570533
-
Axial and tangential fixation strength of pedicle screws versus hooks in the thoracic spine in relation to bone mineral density
-
DOI 10.1097/00007632-200205010-00010
-
Hackenberg L, Link T, Liljenqvist U. Axial and tangential fixation strength of pedicle screws versus hooks in the thoracic spine in relation to bone mineral density. Spine (Phila Pa 1976) 2002 ; 27 : 937-42. (Pubitemid 34506666)
-
(2002)
Spine
, vol.27
, Issue.9
, pp. 937-942
-
-
Hackenberg, L.1
Link, T.2
Liljenqvist, U.3
-
2
-
-
0029070230
-
Segmental pedicle screw fixation in the treatment of thoracic idiopathic scoliosis
-
Suk SI, Lee CK, Kim WJ, et al. Segmental pedicle screw fixation in the treatment of thoracic idiopathic scoliosis. Spine (Phila Pa 1976) 1995 ; 20 : 1399-405.
-
(1995)
Spine (Phila Pa 1976)
, vol.20
, pp. 1399-1405
-
-
Suk, S.I.1
Lee, C.K.2
Kim, W.J.3
-
3
-
-
0036373804
-
Comparative analysis of pedicle screw and hook instrumentation in posterior correction and fusion of idiopathic thoracic scoliosis
-
DOI 10.1007/s00586-002-0415-9
-
Liljenqvist U, Lepsien U, Hackenberg L, et al. Comparative analysis of pedicle screw and hook instrumentation in posterior correction and fusion of idiopathic thoracic scoliosis. Eur Spine J 2002; 11 : 336-43. (Pubitemid 34983936)
-
(2002)
European Spine Journal
, vol.11
, Issue.4
, pp. 336-343
-
-
Liljenqvist, U.1
Lepsien, U.2
Hackenberg, L.3
Niemeyer, T.4
Halm, H.5
-
4
-
-
0028567083
-
Comparison of Cotrel-Dubousset pedicle screws and hooks in the treatment of idiopathic scoliosis
-
Suk SI, Lee CK, Min HJ, et al. Comparison of Cotrel-Dubousset pedicle screws and hooks in the treatment of idiopathic scoliosis. Int Orthop 1994; 18 : 341-6.
-
(1994)
Int Orthop
, vol.18
, pp. 341-346
-
-
Suk, S.I.1
Lee, C.K.2
Min, H.J.3
-
5
-
-
0033982591
-
Scoliosis correction maintenance in skeletally immature patients with idiopathic scoliosis: Is anterior fusion really necessary?
-
DOI 10.1097/00007632-200001010-00012
-
Burton DC, Asher MA, Lai SM. Scoliosis correction maintenance in skeletally immature patients with idiopathic scoliosis. Is anterior fusion really necessary ? Spine (Phila Pa 1976) 2000 ; 25 : 61-8. (Pubitemid 30035984)
-
(2000)
Spine
, vol.25
, Issue.1
, pp. 61-68
-
-
Burton, D.C.1
Asher, M.A.2
Lai, S.M.3
-
6
-
-
14844302180
-
Accuracy and efficacy of thoracic pedicle screws in curves more than 90degrees
-
DOI 10.1097/01.brs.0000150482.26918.d8
-
Kuklo TR, Lenke LG, O'Brien MF, et al. Accuracy and efficacy of thoracic pedicle screws in curves more than 90 degrees. Spine (Phila Pa 1976) 2005 ; 30 : 222-6. (Pubitemid 40348214)
-
(2005)
Spine
, vol.30
, Issue.2
, pp. 222-226
-
-
Kuklo, T.R.1
Lenke, L.G.2
O'Brien, M.F.3
Lehman Jr., R.A.4
Polly Jr., D.W.5
Schroeder, T.M.6
-
7
-
-
13444291573
-
Comparative analysis of pedicle screw versus hook instrumentation in posterior spinal fusion of adolescent idiopathic scoliosis
-
DOI 10.1097/01.brs.0000138268.12324.1a
-
Kim YJ, Lenke LG, Bridwell KH. Comparative analysis of pedicle screw versus hook instrumentation in posterior spinal fusion of adolescent idiopathic scoliosis. Spine (Phila Pa 1976) 2004 ; 29 : 2040-8. (Pubitemid 40202276)
-
(2004)
Spine
, vol.29
, Issue.18
, pp. 2040-2048
-
-
Kim, Y.J.1
Lenke, L.G.2
Cho, S.K.3
Bridwell, K.H.4
Sides, B.5
Blanke, K.6
-
8
-
-
0028046151
-
Comprehensive literature review. Pedicle screw fixation devices
-
Yahiro MA. Comprehensive literature review. Pedicle screw fixation devices. Spine (Phila Pa 1976) 1994; 19 : S2274-8.
-
(1994)
Spine (Phila Pa 1976)
, vol.19
-
-
Yahiro, M.A.1
-
9
-
-
0035500223
-
In vivo accuracy of thoracic pedicle screws
-
DOI 10.1097/00007632-200111010-00010
-
Belmont PJ Jr, Klemme WR, Dhawan A, et al. In vivo accuracy of thoracic pedicle screws. Spine (Phila Pa 1976) 2001 ; 26 : 2340-6. (Pubitemid 33043316)
-
(2001)
Spine
, vol.26
, Issue.21
, pp. 2340-2346
-
-
Belmont Jr., P.J.1
Klemme, W.R.2
Dhawan, A.3
Polly Jr., D.W.4
-
10
-
-
0037099509
-
Accuracy of thoracic pedicle screws in patients with and without coronal plane spinal deformities
-
DOI 10.1097/00007632-200207150-00015
-
Belmont PJ Jr, Klemme WR, Robinson M, et al. Accuracy of thoracic pedicle screws in patients with and without coronal plane spinal deformities. Spine (Phila Pa 1976) 2002 ; 27 : 1558-66. (Pubitemid 34787183)
-
(2002)
Spine
, vol.27
, Issue.14
, pp. 1558-1566
-
-
Belmont Jr., P.J.1
Klemme, W.R.2
Robinson, M.3
Polly Jr., D.W.4
-
11
-
-
0031413907
-
Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis
-
DOI 10.1097/00007632-199710010-00008
-
Liljenqvist UR, Halm H, Link TM. Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis. Spine (Phila Pa 1976) 1997 ; 22 : 2239-45. (Pubitemid 28074054)
-
(1997)
Spine
, vol.22
, Issue.19
, pp. 2239-2245
-
-
Liljenqvist, U.R.1
Halm, H.F.H.2
Link, T.M.3
-
12
-
-
0035884966
-
Thoracic pedicle screw fixation in spinal deformities: Are they really safe ?
-
Suk SI, Kim WJ, Lee SM, et al. Thoracic pedicle screw fixation in spinal deformities: are they really safe ? Spine (Phila Pa 1976) 2001 ; 26 : 2049-57.
-
(2001)
Spine (Phila Pa 1976)
, vol.26
, pp. 2049-2057
-
-
Suk, S.I.1
Kim, W.J.2
Lee, S.M.3
-
13
-
-
33846683025
-
Pedicle screw placement accuracy: A meta-analysis
-
DOI 10.1097/01.brs.0000254048.79024.8b, PII 0000763220070201000022
-
Kosmopoulos V, Schizas C. Pedicle screw placement accuracy. A meta-analysis. Spine (Phila Pa 1976) 2007; 32 : E111-20. (Pubitemid 46197463)
-
(2007)
Spine
, vol.32
, Issue.3
-
-
Kosmopoulos, V.1
Schizas, C.2
-
14
-
-
0032912834
-
Unusual presentation of spinal cord compression related to misplaced pedicle screws in thoracic scoliosis
-
Papin P, Arlet V, Marchesi D, et al. Unusual presentation of spinal cord compression related to misplaced pedicle screws in thoracic scoliosis. Eur Spine J 1999; 8 : 156-9.
-
(1999)
Eur Spine J
, vol.8
, pp. 156-159
-
-
Papin, P.1
Arlet, V.2
Marchesi, D.3
-
15
-
-
0029009135
-
Reversible anterior cord syndrome due to penetration of the spinal canal by pedicular screws
-
Yalcin S, Guven O. Reversible anterior cord syndrome due to penetration of the spinal canal by pedicular screws. Paraplegia 1995; 33 : 423-5.
-
(1995)
Paraplegia
, vol.33
, pp. 423-425
-
-
Yalcin, S.1
Guven, O.2
-
16
-
-
0029852171
-
The removal of a transdural pedicle screw placed for thoracolumbar spine fracture
-
Donovan DJ, Polly DW, Ondra SL. The removal of a transdural pedicle screw placed for thoracolumbar spine fracture. Spine (Phila Pa 1976) 1996 ; 21 : 2495-8.
-
(1996)
Spine (Phila Pa 1976)
, vol.21
, pp. 2495-2498
-
-
Donovan, D.J.1
Polly, D.W.2
Ondra, S.L.3
-
17
-
-
0022501586
-
Spontaneous abdominal aortic rupture from erosion by a lumbar spine fixation device. A case report
-
Jendrisak MD. Spontaneous abdominal aortic rupture from erosion by a lumbar spine fixation device: a case report. Surgery 1986; 99 : 631-3. (Pubitemid 16024073)
-
(1986)
Surgery
, vol.99
, Issue.5
, pp. 631-633
-
-
Jendrisak, M.D.1
-
18
-
-
0033834616
-
Accuracy of pedicle screw insertion with and without computer assistance: A randomized controlled clinical study in 100 consecutive patients
-
Laine T, Lund T, Ylikoski M, et al. Accuracy of pedicle screw insertion with and without computer assistance: a randomized controlled clinical study in 100 consecutive patients. Eur Spine J 2000; 9 : 235-40.
-
(2000)
Eur Spine J
, vol.9
, pp. 235-240
-
-
Laine, T.1
Lund, T.2
Ylikoski, M.3
-
19
-
-
3242676907
-
Estimation of patient dose and associated radiogenic risks from fluoroscopically guided pedicle screw insertion
-
DOI 10.1097/01.BRS.0000131214.57597.21
-
Perisinakis K, Theocharopoulos N, Damilakis J, et al. Estimation of patient dose and associated radiogenic risks from fluoroscopically guided pedicle screw insertion. Spine (Phila Pa 1976) 2004 ; 29 : 1555-60. (Pubitemid 38943840)
-
(2004)
Spine
, vol.29
, Issue.14
, pp. 1555-1560
-
-
Perisinakis, K.1
Theocharopoulos, N.2
Damilakis, J.3
Katonis, P.4
Papadokostakis, G.5
Hadjipavlou, A.6
Gourtsoyiannis, N.7
-
20
-
-
33749519625
-
Radiation exposure during pedicle screw placement in adolescent idiopathic scoliosis: Is fluoroscopy safe?
-
DOI 10.1097/01.brs.0000238675.91612.2f, PII 0000763220061001000019
-
Ul Haque M, Shufflebarger HL, O'Brien MF, et al. Radiation exposure during pedicle screw placement in adolescent idiopathic scoliosis: is fluoroscopy safe ? Spine (Phila Pa 1976) 2006 ; 31 : 2516-20. (Pubitemid 44527037)
-
(2006)
Spine
, vol.31
, Issue.21
, pp. 2516-2520
-
-
Ul Haque, M.1
Shufflebarger, H.L.2
O'Brien, M.3
Macagno, A.4
-
21
-
-
0034667336
-
Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion
-
Rampersaud YR, Foley KT, Shen AC, et al. Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion. Spine (Phila Pa 1976) 2000 ; 25 : 2637-45.
-
(2000)
Spine (Phila Pa 1976)
, vol.25
, pp. 2637-2645
-
-
Rampersaud, Y.R.1
Foley, K.T.2
Shen, A.C.3
-
22
-
-
33644652164
-
A preliminary study of reliability of impedance measurement to detect iatrogenic initial pedicle perforation (in the porcine model)
-
DOI 10.1007/s00586-005-1024-1
-
Bolger C, Carozzo C, Roger T, et al. A preliminary study of reliability of impedance measurement to detect iatrogenic initial pedicle perforation (in the porcine model). Eur Spine J 2006; 15 : 316-20. (Pubitemid 43327665)
-
(2006)
European Spine Journal
, vol.15
, Issue.3
, pp. 316-320
-
-
Bolger, C.1
Carozzo, C.2
Roger, T.3
McEvoy, L.4
Nagaria, J.5
Vanacker, G.6
Bourlion, M.7
-
23
-
-
0032532465
-
Clinical relevance of accuracy of pedicle screw placement: A computed tomographic-supported analysis
-
DOI 10.1097/00007632-199810150-00014
-
Schulze CJ, Munzinger E, Weber U. Clinical relevance of accuracy of pedicle screw placement. A computed tomographic-supported analysis. Spine (Phila Pa 1976) 1998 ; 23 : 2215-20. (Pubitemid 28485179)
-
(1998)
Spine
, vol.23
, Issue.20
, pp. 2215-2220
-
-
Schulze, C.J.1
Munzinger, E.2
Weber, U.3
-
24
-
-
0031438992
-
Accuracy of pedicle screw insertion: A prospective CT study in 30 low back patients
-
DOI 10.1007/BF01834068
-
Laine T, Makitalo K, Schlenzka D, et al. Accuracy of pedicle screw insertion: a prospective CT study in 30 low back patients. Eur Spine J 1997; 6 : 402-5. (Pubitemid 28034372)
-
(1997)
European Spine Journal
, vol.6
, Issue.6
, pp. 402-405
-
-
Laine, T.1
Makitalo, K.2
Schlenzka, D.3
Tallroth, K.4
Poussa, M.5
Alho, A.6
-
25
-
-
0025267440
-
Accuracy of pedicular screw placement in vivo
-
Gertzbein SD, Robbins SE. Accuracy of pedicular screw placement in vivo. Spine (Phila Pa 1976) 1990 ; 15 : 11-4. (Pubitemid 20102491)
-
(1990)
Spine
, vol.15
, Issue.1
, pp. 11-14
-
-
Gertzbein, S.D.1
Robbins, S.E.2
-
26
-
-
1842564006
-
Assessment of Pedicle Screw Placement Utilizing Conventional Radiography and Computed Tomography: A Proposed Systematic Approach to Improve Accuracy of Interpretation
-
DOI 10.1097/01.BRS.0000112071.69448.A1
-
Learch TJ, Massie JB, Pathria MN, et al. Assessment of pedicle screw placement utilizing conventional radiography and computed tomography: a proposed systematic approach to improve accuracy of interpretation. Spine (Phila Pa 1976) 2004 ; 29 : 767-73. (Pubitemid 38437526)
-
(2004)
Spine
, vol.29
, Issue.7
, pp. 767-773
-
-
Learch, T.J.1
Massie, J.B.2
Pathria, M.N.3
Ahlgren, B.A.4
Garfin, S.R.5
-
27
-
-
0023790873
-
Spinal pedicle fixation: Reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement
-
DOI 10.1097/00007632-198809000-00008
-
Weinstein JN, Spratt KF, Spengler D, et al. Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine (Phila Pa 1976) 1988 ; 13 : 1012-8. (Pubitemid 18266476)
-
(1988)
Spine
, vol.13
, Issue.9
, pp. 1012-1018
-
-
Weinstein, J.N.1
Spratt, K.F.2
Spengler, D.3
Brick, C.4
Reid, S.5
-
28
-
-
0036237788
-
Transpedicular thoracic screws: General concepts and insertion technique using fluoroscopic guidance
-
Klemme WR, Belmont PJ Jr, Polly DW Jr. Transpedicular thoracic screws: general concepts and insertion technique using fluoroscopic guidance. Semin Spine Surg 2002; 14 : 43-7. (Pubitemid 34464921)
-
(2002)
Seminars in Spine Surgery
, vol.14
, Issue.1
, pp. 43-47
-
-
Klemme, W.R.1
Belmont Jr., P.J.2
Polly Jr., D.W.3
-
29
-
-
0036240952
-
Advanced image guidance for the placement of thoracic pedicle screws
-
Rampersaud YR. Advanced image guidance for the placement of thoracic pedicle screws. Semin Spine Surg 2002; 14 : 58-65. (Pubitemid 34464923)
-
(2002)
Seminars in Spine Surgery
, vol.14
, Issue.1
, pp. 58-65
-
-
Rampersaud, Y.R.1
-
31
-
-
0029986628
-
Evoked and spontaneous electromyography to evaluate lumbosacral pedicle screw placement
-
DOI 10.1097/00007632-199603010-00013
-
Clements DH, Morledge DE, Martin WH, et al. Evoked and spontaneous electromyography to evaluate lumbosacral pedicle screw placement. Spine (Phila Pa 1976) 1996 ; 21 : 600-4. (Pubitemid 26077800)
-
(1996)
Spine
, vol.21
, Issue.5
, pp. 600-604
-
-
Clements, D.H.1
Morledge, D.E.2
Martin, W.H.3
Betz, R.R.4
-
32
-
-
84875052093
-
A new device to detect iatrogenic initial vertebral cortex perforation: First clinical results [abstract]
-
Bolger C, Brayda-Bruno M, Kaelin A, et al. A new device to detect iatrogenic initial vertebral cortex perforation: first clinical results [abstract]. Eur Spine J 2003; 12.
-
(2003)
Eur Spine J
, vol.12
-
-
Bolger, C.1
Brayda-Bruno, M.2
Kaelin, A.3
|