-
1
-
-
0035312809
-
American College of Cardiology Clinical Expert Consensus Document on standards for acquisition, measurement and reporting of intravascular ultrasound studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents
-
Mintz GS, Nissen SE, Anderson WD, et al. American College of Cardiology Clinical Expert Consensus Document on standards for acquisition, measurement and reporting of intravascular ultrasound studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents. J Am Coll Cardiol 2001;37:1478-92.
-
(2001)
J Am Coll Cardiol
, vol.37
, pp. 1478-1492
-
-
Mintz, G.S.1
Nissen, S.E.2
Anderson, W.D.3
-
2
-
-
69049106503
-
Late-acquired incomplete stent apposition: Morphologic characterization
-
Hur SH, Ako J, Honda Y, et al. Late-acquired incomplete stent apposition: morphologic characterization. Cardiovasc Revasc Med 2009;10:236-46.
-
(2009)
Cardiovasc Revasc Med
, vol.10
, pp. 236-246
-
-
Hur, S.H.1
Ako, J.2
Honda, Y.3
-
3
-
-
10744221922
-
Incidence, mechanism, predictors, and long-term prognosis of late stent malapposition after bare-metal stent implantation
-
This study demonstrated an incidence of 5% LASM following BMS implantation. Major predictors were stenting in the setting of an AMI and directional coronary atherectomy before stent placement. No clinical events were recorded over a 3 year follow up period
-
Hong MK, Mintz GS, Lee CW, et al. Incidence, mechanism, predictors, and long-term prognosis of late stent malapposition after bare-metal stent implantation. Circulation 2004;109:881-6. This study demonstrated an incidence of 5% LASM following BMS implantation. Major predictors were stenting in the setting of an AMI and directional coronary atherectomy before stent placement. No clinical events were recorded over a 3 year follow up period.
-
(2004)
Circulation
, vol.109
, pp. 881-886
-
-
Hong, M.K.1
Mintz, G.S.2
Lee, C.W.3
-
4
-
-
41949111999
-
Stent Malapposition After Sirolimus-Eluting and Bare-Metal Stent Implantation in Patients with ST-Segment Elevation Myocardial Infarction. Acute and 9-Month Intravascular Ultrasound Results of the MISSION! Intervention Study
-
DOI 10.1016/j.jcin.2008.02.003, PII S1936879808000927
-
van der Hoeven BL, Liem SS, Dijkstra J, et al. Stent malapposition after sirolimus-eluting and bare-metal stent implantation in patients with ST-segment elevation myocardial infarction: acute and 9-month intravascular ultrasound results of the MISSION! intervention study. JACC Cardiovasc Interv 2008;1:192-201. This study reports the highest incidence of LASM in the literature, among patients having a sirolimus eluting stent implanted in the setting of an AMI. (Pubitemid 351506561)
-
(2008)
JACC: Cardiovascular Interventions
, vol.1
, Issue.2
, pp. 192-201
-
-
Van Der Hoeven, B.L.1
Liem, S.-S.2
Dijkstra, J.3
Bergheanu, S.C.4
Putter, H.5
Antoni, M.L.6
Atsma, D.E.7
Bootsma, M.8
Zeppenfeld, K.9
Jukema, J.W.10
Schalij, M.J.11
-
5
-
-
77952378647
-
Late stent malapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosis
-
In this meta-analysis, it is clearly demonstrated that the risk of LASM is higher after DES implantation, compared to BMS, while LASM seems to be associated with late and very late stent thrombosis
-
Hassan AK, Bergheanu SC, Stijnen T, et al. Late stent malapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosis. Eur Heart J 2010;31:1172-80. In this meta-analysis, it is clearly demonstrated that the risk of LASM is higher after DES implantation, compared to BMS, while LASM seems to be associated with late and very late stent thrombosis.
-
(2010)
Eur Heart J
, vol.31
, pp. 1172-1180
-
-
Hassan, A.K.1
Bergheanu, S.C.2
Stijnen, T.3
-
6
-
-
75749146310
-
Post-intervention IVUS is not predictive for very late in-stent thrombosis in drug-eluting stents
-
This study demonstrated that immediate post-intervention IVUS showing no malapposition does not guarantee an uneventful course after DES implantation
-
Bergheanu SC, Van der Hoeven BL, Hassan AK, et al. Post-intervention IVUS is not predictive for very late in-stent thrombosis in drug-eluting stents. Acta Cardiol 2009;64:611-16. This study demonstrated that immediate post-intervention IVUS showing no malapposition does not guarantee an uneventful course after DES implantation.
-
(2009)
Acta Cardiol
, vol.64
, pp. 611-616
-
-
Bergheanu, S.C.1
Van Der Hoeven, B.L.2
Hassan, A.K.3
-
7
-
-
34248227700
-
Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation
-
DOI 10.1161/CIRCULATIONAHA.106.658237, PII 0000301720070508000012
-
Cook S, Wenaweser P, Togni M, et al. Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation. Circulation 2007;115:2426-34. This study demonstrated a strong association between the prevalence of incomplete stent apposition and very late stent thrombosis after DES implantation, suggesting a role in the pathogenesis of this adverse event. (Pubitemid 46717965)
-
(2007)
Circulation
, vol.115
, Issue.18
, pp. 2426-2434
-
-
Cook, S.1
Wenaweser, P.2
Togni, M.3
Billinger, M.4
Morger, C.5
Seiler, C.6
Vogel, R.7
Hess, O.8
Meier, B.9
Windecker, S.10
-
8
-
-
34248202606
-
What to do about late incomplete stent apposition?
-
DOI 10.1161/CIRCULATIONAHA.107.697136, PII 0000301720070508000006
-
Mintz GS. What to do about late incomplete stent apposition? Circulation 2007;115:2379-81. (Pubitemid 46717959)
-
(2007)
Circulation
, vol.115
, Issue.18
, pp. 2379-2381
-
-
Mintz, G.S.1
-
9
-
-
33644861134
-
Late stent malapposition after drug-eluting stent implantation: An intravascular ultrasound analysis with long-term follow-up
-
DOI 10.1161/CIRCULATIONAHA.105.563403, PII 0000301720060124000014
-
Hong MK, Mintz GS, Lee CW, et al. Late stent malapposition after drug-eluting stent implantation: an intravascular ultrasound analysis with long-term follow-up. Circulation 2006;113:414-19. This study reports the incidence of LASM in a patient population where DES were implanted and identifies total stent length, primary stenting in the setting of AMI and chronic total occlusion lesions as significant predictors of LASM. (Pubitemid 43803203)
-
(2006)
Circulation
, vol.113
, Issue.3
, pp. 414-419
-
-
Hong, M.-K.1
Mintz, G.S.2
Lee, C.W.3
Park, D.-W.4
Park, K.-M.5
Lee, B.-K.6
Kim, Y.-H.7
Song, J.-M.8
Han, K.-H.9
Kang, D.-H.10
Cheong, S.-S.11
Song, J.-K.12
Kim, J.-J.13
Park, S.-W.14
Park, S.-J.15
-
10
-
-
0038241919
-
Regional remodeling as the cause of late stent malapposition
-
Mintz GS, Shah VM, Weissman NJ. Regional remodeling as the cause of late stent malapposition. Circulation 2003;107:2660-3. In this study the authors conclude that the main pathogenetic mechanism of LASM is positive arterial remodelling. (Pubitemid 36667237)
-
(2003)
Circulation
, vol.107
, Issue.21
, pp. 2660-2663
-
-
Mintz, G.S.1
Shah, V.M.2
Weissman, N.J.3
-
11
-
-
24944585578
-
Late incomplete stent apposition after sirolimus-eluting stent implantation: A serial intravascular ultrasound analysis
-
DOI 10.1016/j.jacc.2005.05.068, PII S0735109705013975
-
Ako J, Morino Y, Honda Y, et al. Late incomplete stent apposition after sirolimus-eluting stent implantation: a serial intravascular ultrasound analysis. J Am Coll Cardiol 2005;46:1002-5. (Pubitemid 41316506)
-
(2005)
Journal of the American College of Cardiology
, vol.46
, Issue.6
, pp. 1002-1005
-
-
Ako, J.1
Morino, Y.2
Honda, Y.3
Hassan, A.4
Sonoda, S.5
Yock, P.G.6
Leon, M.B.7
Moses, J.W.8
Bonneau, H.N.9
Fitzgerald, P.J.10
-
12
-
-
77449133793
-
Polymer coatings and delayed arterial healing following drug-eluting stent implantation
-
Byrne RA, Joner M, Kastrati A. Polymer coatings and delayed arterial healing following drug-eluting stent implantation. Minerva Cardioangiol 2009;57:567-84.
-
(2009)
Minerva Cardioangiol
, vol.57
, pp. 567-584
-
-
Byrne, R.A.1
Joner, M.2
Kastrati, A.3
-
13
-
-
10744229988
-
Localized Hypersensitivity and Late Coronary Thrombosis Secondary to a Sirolimus-Eluting Stent: Should We Be Cautious?
-
DOI 10.1161/01.CIR.0000116202.41966.D4
-
Virmani R, Guagliumi G, Farb A, et al. Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious? Circulation 2004;109:701-5. In this paper, a hypersensitivity reaction to sirolimus eluting stents is discussed, giving us some insights on the pathogenetic mechanisms probably involved in the positive arterial remodeling and LASM. (Pubitemid 38222887)
-
(2004)
Circulation
, vol.109
, Issue.6
, pp. 701-705
-
-
Virmani, R.1
Guagliumi, G.2
Farb, A.3
Musumeci, G.4
Grieco, N.5
Motta, T.6
Mihalcsik, L.7
Tespili, M.8
Valsecchi, O.9
Kolodgie, F.D.10
-
14
-
-
36849065425
-
Comparison of vascular response to zotarolimus-eluting stent versus sirolimus-eluting stent: Intravascular ultrasound results from ENDEAVOR III
-
DOI 10.1016/j.ahj.2007.08.008, PII S0002870307006734
-
Miyazawa A, Ako J, Hongo Y, et al. Comparison of vascular response to zotarolimus-eluting stent versus sirolimus-eluting stent: intravascular ultrasound results from ENDEAVOR III. Am Heart J 2008;155:108-13. (Pubitemid 350234763)
-
(2008)
American Heart Journal
, vol.155
, Issue.1
, pp. 108-113
-
-
Miyazawa, A.1
Ako, J.2
Hongo, Y.3
Hur, S.-H.4
Tsujino, I.5
Courtney, B.K.6
Hassan, A.H.M.7
Kandzari, D.E.8
Honda, Y.9
Fitzgerald, P.J.10
-
15
-
-
42549117199
-
Neointimal coverage of bare-metal and sirolimus-eluting stents evaluated with optical coherence tomography
-
DOI 10.1136/hrt.2007.118679
-
Chen BX, Ma FY, Luo W, et al. Neointimal coverage of bare-metal and sirolimus-eluting stents evaluated with optical coherence tomography. Heart 2008;94:566-70. (Pubitemid 351580126)
-
(2008)
Heart
, vol.94
, Issue.5
, pp. 566-570
-
-
Chen, B.X.1
Ma, F.Y.2
Luo, W.3
Ruan, J.H.4
Xie, W.L.5
Zhao, X.Z.6
Sun, S.H.7
Guo, X.M.8
Wang, F.9
Tian, T.10
Chu, X.W.11
-
16
-
-
80051549273
-
Delayed coverage in malapposed and side-branch struts with respect to well-apposed struts in drug-eluting stents: In vivo assessment with optical coherence tomography
-
Gutierrez-Chico JL, Regar E, Nuesch E, et al. Delayed coverage in malapposed and side-branch struts with respect to well-apposed struts in drug-eluting stents: in vivo assessment with optical coherence tomography. Circulation 2011;124:612-23.
-
(2011)
Circulation
, vol.124
, pp. 612-623
-
-
Gutierrez-Chico, J.L.1
Regar, E.2
Nuesch, E.3
-
17
-
-
80051543813
-
Polymer-free sirolimus- And probucol-eluting versus new generation zotarolimus-eluting stents in coronary artery disease: The Intracoronary Stenting and Angiographic Results: Test Efficacy of Sirolimus- and Probucol-Eluting versus Zotarolimus-eluting Stents (ISAR-TEST 5) trial
-
Massberg S, Byrne RA, Kastrati A, et al. Polymer-free sirolimus- and probucol-eluting versus new generation zotarolimus-eluting stents in coronary artery disease: the Intracoronary Stenting and Angiographic Results: Test Efficacy of Sirolimus- and Probucol-Eluting versus Zotarolimus-eluting Stents (ISAR-TEST 5) trial. Circulation 2011;124:624-32.
-
(2011)
Circulation
, vol.124
, pp. 624-632
-
-
Massberg, S.1
Byrne, R.A.2
Kastrati, A.3
-
18
-
-
79551692953
-
A comparative assessment by optical coherence tomography of the performance of the first and second generation of the everolimus-eluting bioresorbable vascular scaffolds
-
Gomez-Lara J, Brugaletta S, Diletti R, et al. A comparative assessment by optical coherence tomography of the performance of the first and second generation of the everolimus-eluting bioresorbable vascular scaffolds. Eur Heart J 2011;32:294-304.
-
(2011)
Eur Heart J
, vol.32
, pp. 294-304
-
-
Gomez-Lara, J.1
Brugaletta, S.2
Diletti, R.3
-
19
-
-
80355129156
-
Assessment of the safety and performance of the STENTYS self-expanding coronary stent in acute myocardial infarction: Results from the APPOSITION I study
-
This is a report about the safety and efficacy of the STENTYS self-expanding coronary stent. This stent, by optimising apposition in AMI patients, significantly reduces the risk of LASM as a result of thrombus dissolution in this high risk group
-
Amoroso G, van Geuns RJ, Spaulding C, et al. Assessment of the safety and performance of the STENTYS self-expanding coronary stent in acute myocardial infarction: results from the APPOSITION I study. EuroIntervention 2011;7:428-36. This is a report about the safety and efficacy of the STENTYS self-expanding coronary stent. This stent, by optimising apposition in AMI patients, significantly reduces the risk of LASM as a result of thrombus dissolution in this high risk group.
-
(2011)
EuroIntervention
, vol.7
, pp. 428-436
-
-
Amoroso, G.1
Van Geuns, R.J.2
Spaulding, C.3
-
20
-
-
79958099678
-
Incidence, risk factors, and clinical sequelae of angiographic peri-stent contrast staining after sirolimus-eluting stent implantation
-
Despite being based on angiographic findings, the authors demonstrated that per-stent contrast staining (an indirect indicator of significant degree of stent malapposition) is associated with a higher incidence of target lesion revascularisation and late stent thrombosis
-
Imai M, Kadota K, Goto T, et al. Incidence, risk factors, and clinical sequelae of angiographic peri-stent contrast staining after sirolimus-eluting stent implantation. Circulation 2011;123:2382-91. Despite being based on angiographic findings, the authors demonstrated that per-stent contrast staining (an indirect indicator of significant degree of stent malapposition) is associated with a higher incidence of target lesion revascularisation and late stent thrombosis.
-
(2011)
Circulation
, vol.123
, pp. 2382-2391
-
-
Imai, M.1
Kadota, K.2
Goto, T.3
|