메뉴 건너뛰기




Volumn , Issue , 2012, Pages 1079-1082

Bidirectional current conveyer with chopper stabilization and dynamic element matching

Author keywords

[No Author keywords available]

Indexed keywords

BIDIRECTIONAL CURRENT; CHOPPER STABILIZATION; CURRENT MIRRORS; DYNAMIC ELEMENT MATCHING; DYNAMIC RANGE; FLICKER NOISE; MIRROR IMAGES; SENSOR CURRENT; TRANSISTOR SIZE;

EID: 84866603351     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ISCAS.2012.6271416     Document Type: Conference Paper
Times cited : (5)

References (11)
  • 1
    • 72949116829 scopus 로고    scopus 로고
    • A wireless ic for time-share chemical and electrical neural recording
    • M. Roham, M. P. Garris, and P. Mohseni,"A Wireless IC for Time-Share Chemical and Electrical Neural Recording," IEEE J. Solid-State Circuits, pp. 3645-3658 ,2009.
    • (2009) IEEE J. Solid-State Circuits , pp. 3645-3658
    • Roham, M.1    Garris, M.P.2    Mohseni, P.3
  • 3
    • 48849089317 scopus 로고    scopus 로고
    • Active cmos sensor array for electrochemical biomolecular detection
    • P. M. Levine, P. Gong, R. Levicky, K.L. Shepard,"Active CMOS Sensor Array for Electrochemical Biomolecular Detection," IEEE J. Solid-State Circuits, vol. 43, no. 8, pp. 1859-1871, 2008.
    • (2008) IEEE J. Solid-State Circuits , vol.43 , Issue.8 , pp. 1859-1871
    • Levine, P.M.1    Gong, P.2    Levicky, R.3    Shepard, K.L.4
  • 4
    • 33845641002 scopus 로고    scopus 로고
    • A Programmable 0.18-m CMOS Electrochemical Sensor Microarray for Bimolecular Detection
    • A. Hassibi and T. H. Lee,"A Programmable 0.18-m CMOS Electrochemical Sensor Microarray for Bimolecular Detection," IEEE Sensors Journal, vol. 6, pp. 1380-1388, 2006.
    • (2006) IEEE Sensors Journal , vol.6 , pp. 1380-1388
    • Hassibi, A.1    Lee, T.H.2
  • 7
    • 33645163858 scopus 로고    scopus 로고
    • A time-based vlsi potentiostat for ion current measurement
    • H. S. Narula, J. G. Harris,"A Time-Based VLSI Potentiostat for Ion Current Measurement," IEEE Sensors Journal, vol. 6, pp. 239-247, 2006.
    • (2006) IEEE Sensors Journal , vol.6 , pp. 239-247
    • Narula, H.S.1    Harris, J.G.2
  • 8
    • 67651160770 scopus 로고    scopus 로고
    • Current-mirror-based potentiostats for three-electrode amperometric electrochemical sensors
    • M. Ahmadi and G. Jullien,"Current-Mirror-Based Potentiostats for Three-Electrode Amperometric Electrochemical Sensors," IEEE Transactions on Circuits and Systems I, vol. 56, pp. 1339-1348, 2009.
    • (2009) IEEE Transactions on Circuits and Systems i , vol.56 , pp. 1339-1348
    • Ahmadi, M.1    Jullien, G.2
  • 9
    • 77949373334 scopus 로고    scopus 로고
    • CMOS VLSI potentiostat for portable environmental sensing applications
    • S. Hwang and S. Sonkusale,"CMOS VLSI Potentiostat for Portable Environmental Sensing Applications," IEEE Sensors Journal, vol. 10, pp. 820-821, 2010.
    • (2010) IEEE Sensors Journal , vol.10 , pp. 820-821
    • Hwang, S.1    Sonkusale, S.2
  • 10
    • 34247258854 scopus 로고    scopus 로고
    • Design of a CMOS Potentiostat Circuit for Electrochemical Detector Arrays
    • April
    • S. Ayers, K. D. Gillis, M. Lindau and B. A. Minch,"Design of a CMOS Potentiostat Circuit for Electrochemical Detector Arrays," IEEE Transactions on Circuits and Systems I, vol. 54, no. 4, pp. 736-744, April 2007.
    • (2007) IEEE Transactions on Circuits and Systems i , vol.54 , Issue.4 , pp. 736-744
    • Ayers, S.1    Gillis, K.D.2    Lindau, M.3    Minch, B.A.4
  • 11
    • 84866635269 scopus 로고    scopus 로고
    • Accurate and high output impedance current mirror suitable for cmos current output stages
    • A. Zeki and H. Kuntman,"Accurate and High Output Impedance Current Mirror Suitable for CMOS Current Output Stages," IEEE Sensors Journal, vol. 6, pp. 1380-1388, 2006.
    • (2006) IEEE Sensors Journal , vol.6 , pp. 1380-1388
    • Zeki, A.1    Kuntman, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.