메뉴 건너뛰기




Volumn 51, Issue , 2008, Pages 168-170

CMOS electro-chemical DNA-detection array with on-chip ADC

Author keywords

[No Author keywords available]

Indexed keywords

CHEMICAL DETECTION; CMOS INTEGRATED CIRCUITS; DISEASES; DNA; ELECTRODES; ELECTROLYTES; MICROSENSORS; SIGNAL TO NOISE RATIO; VIRUSES;

EID: 49549113862     PISSN: 01936530     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ISSCC.2008.4523110     Document Type: Conference Paper
Times cited : (59)

References (8)
  • 1
    • 0036188531 scopus 로고    scopus 로고
    • Stains, labels and detection strategies for nucleic acids assays
    • Mar
    • L. J. Kricka, "Stains, labels and detection strategies for nucleic acids assays," Annals of Clinical Biochemistry vol. 39, pt 2, pp.114-129, Mar. 2002.
    • (2002) Annals of Clinical Biochemistry , vol.39 , Issue.PART 2 , pp. 114-129
    • Kricka, L.J.1
  • 2
    • 10444230343 scopus 로고    scopus 로고
    • A Fully Electronic DNA Sensor With 128 Positions and In-Pixel A/D Conversion
    • Dec
    • M. Schienle, C. Paulus, A. Frey et al., "A Fully Electronic DNA Sensor With 128 Positions and In-Pixel A/D Conversion," IEEE J. Solid-State Circuits, pp. 2438-2445, Dec. 2004.
    • (2004) IEEE J. Solid-State Circuits , pp. 2438-2445
    • Schienle, M.1    Paulus, C.2    Frey, A.3
  • 3
    • 39749094332 scopus 로고    scopus 로고
    • Fully Electronic CMOS DNA Detection Array Based on Capacitance Measurement with On-Chip Analog-to-Digital Conversion
    • C. S. D. Esposti, C. Guiducci, C. Paulus et al., "Fully Electronic CMOS DNA Detection Array Based on Capacitance Measurement with On-Chip Analog-to-Digital Conversion," ISSCC Dig. Tech. Papers, pp. 48-49, 2006.
    • (2006) ISSCC Dig. Tech. Papers , pp. 48-49
    • Esposti, C.S.D.1    Guiducci, C.2    Paulus, C.3
  • 5
    • 21844466991 scopus 로고    scopus 로고
    • Impedance Characterization and Modeling of Electrodes for Biomedical Applications
    • July
    • W. Franks, I. Schenker, P. Schmutz et al., "Impedance Characterization and Modeling of Electrodes for Biomedical Applications," IEEE T. Biomed. Eng., pp.1295-1302, July 2005.
    • (2005) IEEE T. Biomed. Eng , pp. 1295-1302
    • Franks, W.1    Schenker, I.2    Schmutz, P.3
  • 6
    • 0037438482 scopus 로고    scopus 로고
    • Label-Free DNA Hybridization Probe Based on a Conducting Polymer
    • Jan. 15
    • L. A. Thompson, J. Kowalik, M. Josowicz et al., "Label-Free DNA Hybridization Probe Based on a Conducting Polymer, "J. Am. Chem. Soc., vol. 125, No. 2, pp. 324-325, Jan. 15, 2003.
    • (2003) J. Am. Chem. Soc , vol.125 , Issue.2 , pp. 324-325
    • Thompson, L.A.1    Kowalik, J.2    Josowicz, M.3
  • 7
    • 49549120330 scopus 로고    scopus 로고
    • Label-Free DNA Detection of Hepatitis C Virus (HCV-1), 210th Meeting of The Electrochemcial Society in Cancun Mexico, Abstract # 2091, 2006, and Anal
    • submitted
    • C. D. Riccardi, J. Kowalik, M. Josowicz, et al, "Label-Free DNA Detection of Hepatitis C Virus (HCV-1)," 210th Meeting of The Electrochemcial Society in Cancun Mexico, Abstract # 2091, 2006, and Anal. Chem. submitted.
    • Chem
    • Riccardi, C.D.1    Kowalik, J.2    Josowicz, M.3
  • 8
    • 20444489194 scopus 로고    scopus 로고
    • Transfer and Evaluation of an Automated, Low-Cost Real-Time Reverse Transcription-PCR Test for Diagnosis and Monitoring of Human Immunodeficiency Virus Type 1 Infection in a West African Re source-Limited Setting
    • June
    • F. Rouet, D. K. Elkouevi, M-L. Chaix et al., "Transfer and Evaluation of an Automated, Low-Cost Real-Time Reverse Transcription-PCR Test for Diagnosis and Monitoring of Human Immunodeficiency Virus Type 1 Infection in a West African Re source-Limited Setting," Journal of Clinical Microbiology, vol. 43, No. 6, pp. 2709-2017, June 2005.
    • (2005) Journal of Clinical Microbiology , vol.43 , Issue.6 , pp. 2709-2017
    • Rouet, F.1    Elkouevi, D.K.2    Chaix, M.-L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.