메뉴 건너뛰기




Volumn 154, Issue 2, 2012, Pages

Long-term effect of surface light scattering and glistenings of intraocular lenses on visual function

Author keywords

[No Author keywords available]

Indexed keywords

POLY(METHYL METHACRYLATE); SILICONE;

EID: 84866351428     PISSN: 00029394     EISSN: 18791891     Source Type: Journal    
DOI: 10.1016/j.ajo.2012.03.011     Document Type: Article
Times cited : (58)

References (37)
  • 1
    • 0031899326 scopus 로고    scopus 로고
    • Relationship between intraocular lens biomaterials and posterior capsule opacification
    • Ursell PG, Spalton DJ, Pande MV, et al. Relationship between intraocular lens biomaterials and posterior capsule opacification. J Cataract Refract Surg 1998;24(3):352-360.
    • (1998) J Cataract Refract Surg , vol.24 , Issue.3 , pp. 352-360
    • Ursell, P.G.1    Spalton, D.J.2    Pande, M.V.3
  • 2
    • 0032622426 scopus 로고    scopus 로고
    • The effect of polymethylmethacrylate, silicone, and polyacrylic intraocular lenses on posterior capsular opacification 3 years after cataract surgery
    • discussion 54-55
    • Hollick EJ, Spalton DJ, Ursell PG, et al. The effect of polymethylmethacrylate, silicone, and polyacrylic intraocular lenses on posterior capsular opacification 3 years after cataract surgery. Ophthalmology 1999;106(1):49 -54; discussion 54-55.
    • (1999) Ophthalmology , vol.106 , Issue.1 , pp. 49-54
    • Hollick, E.J.1    Spalton, D.J.2    Ursell, P.G.3
  • 3
    • 0032424289 scopus 로고    scopus 로고
    • Quantitative comparison of posterior capsule opacification after polymethylmethacrylate, silicone, and soft acrylic intraocular lens implantation
    • Hayashi H, Hayashi K, Nakao F, Hayashi F. Quantitative comparison of posterior capsule opacification after polymethylmethacrylate, silicone, and soft acrylic intraocular lens implantation. Arch Ophthalmol 1998;116(12):1579 -1582.
    • (1998) Arch Ophthalmol , vol.116 , Issue.12 , pp. 1579-1582
    • Hayashi, H.1    Hayashi, K.2    Nakao, F.3    Hayashi, F.4
  • 4
    • 0034975265 scopus 로고    scopus 로고
    • Changes in posterior capsule opacification after poly(methyl methacrylate), silicone, and acrylic intraocular lens implantation
    • Hayashi K, Hayashi H, Nakao F, Hayashi F. Changes in posterior capsule opacification after poly(methyl methacrylate), silicone, and acrylic intraocular lens implantation. J Cataract Refract Surg 2001;27(6):817-824.
    • (2001) J Cataract Refract Surg , vol.27 , Issue.6 , pp. 817-824
    • Hayashi, K.1    Hayashi, H.2    Nakao, F.3    Hayashi, F.4
  • 5
    • 77955705410 scopus 로고    scopus 로고
    • Glistenings and surface light scattering in intraocular lens
    • Werner L. Glistenings and surface light scattering in intraocular lens. J Cataract Refract Surg 2010;36(8):1398 -1420.
    • (2010) J Cataract Refract Surg , vol.36 , Issue.8 , pp. 1398-1420
    • Werner, L.1
  • 6
    • 0031916642 scopus 로고    scopus 로고
    • In vitro analysis of AcrySof intraocular lens glistenings in AcryPak and Wagon Wheel package
    • Omar O, Pirayesh A, Mamalis N, Olson RJ. In vitro analysis of AcrySof intraocular lens glistenings in AcryPak and Wagon Wheel package. J Cataract Refract Surg 1998;24(1): 107-113.
    • (1998) J Cataract Refract Surg , vol.24 , Issue.1 , pp. 107-113
    • Omar, O.1    Pirayesh, A.2    Mamalis, N.3    Olson, R.J.4
  • 9
    • 0035689833 scopus 로고    scopus 로고
    • Clinical and experimental observation of glistenings in acrylic intraocular lens
    • Miyata A, Uchida N, Nakajima K, Yaguchi S. Clinical and experimental observation of glistenings in acrylic intraocular lens. Jpn J Ophthalmol 2001;45(6):564 -569.
    • (2001) Jpn J Ophthalmol , vol.45 , Issue.6 , pp. 564-569
    • Miyata, A.1    Uchida, N.2    Nakajima, K.3    Yaguchi, S.4
  • 10
    • 0036069088 scopus 로고    scopus 로고
    • In vitro comparison of glistening formation among hydrophobic acrylic intraocular lenses
    • Gregori NZ, Spencer TS, Mamalis N, Olson RJ. In vitro comparison of glistening formation among hydrophobic acrylic intraocular lenses. J Cataract Refract Surg 2002; 28(7):1262-1268.
    • (2002) J Cataract Refract Surg , vol.28 , Issue.7 , pp. 1262-1268
    • Gregori, N.Z.1    Spencer, T.S.2    Mamalis, N.3    Olson, R.J.4
  • 12
    • 34250746519 scopus 로고    scopus 로고
    • Glistenings in the singlepiece hydrophobic, acrylic intraocular lenses
    • Waite A, Faulkner N, Olson RJ. Glistenings in the singlepiece hydrophobic, acrylic intraocular lenses. Am J Ophthalmol 2007;144(1):143-144.
    • (2007) Am J Ophthalmol , vol.144 , Issue.1 , pp. 143-144
    • Waite, A.1    Faulkner, N.2    Olson, R.J.3
  • 13
    • 33846632288 scopus 로고    scopus 로고
    • Early opacification of a single-piece hydrophobic acrylic intraocular lens after a triple procedure
    • Iwase T, Sugiyama K. Early opacification of a single-piece hydrophobic acrylic intraocular lens after a triple procedure. J Cataract Refract Surg 2007;33(2):329 -332.
    • (2007) J Cataract Refract Surg , vol.33 , Issue.2 , pp. 329-332
    • Iwase, T.1    Sugiyama, K.2
  • 15
    • 46249096888 scopus 로고    scopus 로고
    • Light scatter on the surface of AcrySof intraocular lenses: Part I. Analysis of lenses retreived from pseudophakic postmortem human eyes
    • Yaguchi S, Nishihara H, Kambhiranond W, Stanley D, Apple DJ. Light scatter on the surface of AcrySof intraocular lenses: part I. Analysis of lenses retreived from pseudophakic postmortem human eyes. Ophthalmic Surg Lasers Imaging 2008;39(3):209 -213.
    • (2008) Ophthalmic Surg Lasers Imaging , vol.39 , Issue.3 , pp. 209-213
    • Yaguchi, S.1    Nishihara, H.2    Kambhiranond, W.3    Stanley, D.4    Apple, D.J.5
  • 16
    • 57649170657 scopus 로고    scopus 로고
    • Quantification of glistenings in intraocular lenses using Scheimpflug photography
    • Behndig A, Mönestam E. Quantification of glistenings in intraocular lenses using Scheimpflug photography. J Cataract Refract Surg 2009;35(1):14 -17.
    • (2009) J Cataract Refract Surg , vol.35 , Issue.1 , pp. 14-17
    • Behndig, A.1    Mönestam, E.2
  • 17
    • 0033997682 scopus 로고    scopus 로고
    • Optical and atomic force microscopy of an explanted AcrySof intraocular lens with glistenings
    • Dogru M, Tetsumoto K, Tagami Y, Kato K, Nakamae K. Optical and atomic force microscopy of an explanted AcrySof intraocular lens with glistenings. J Cataract Refract Surg 2000;26(4):571-575.
    • (2000) J Cataract Refract Surg , vol.26 , Issue.4 , pp. 571-575
    • Dogru, M.1    Tetsumoto, K.2    Tagami, Y.3    Kato, K.4    Nakamae, K.5
  • 18
    • 0034821447 scopus 로고    scopus 로고
    • Glistenings formation in AcrySof lens initiated by spinoidal decomposition of the polymer network by temperature change
    • Kato K, Nishida M, Yamane H, Nakamae K, Tagami Y, Tetsumoto K. Glistenings formation in AcrySof lens initiated by spinoidal decomposition of the polymer network by temperature change. J Cataract Refract Surg 2001;27(9): 1493-1498.
    • (2001) J Cataract Refract Surg , vol.27 , Issue.9 , pp. 1493-1498
    • Kato, K.1    Nishida, M.2    Yamane, H.3    Nakamae, K.4    Tagami, Y.5    Tetsumoto, K.6
  • 19
    • 1042302009 scopus 로고    scopus 로고
    • In vitro analysis of AcrySof intraocular lens glistening
    • Shiba T, Mitooka K, Tsuneoka H. In vitro analysis of AcrySof intraocular lens glistening. Eur J Ophthalmol 2003; 13(9-10):759 -763.
    • (2003) Eur J Ophthalmol , vol.13 , Issue.9-10 , pp. 759-763
    • Shiba, T.1    Mitooka, K.2    Tsuneoka, H.3
  • 20
    • 4143136525 scopus 로고    scopus 로고
    • Equilibrium water content and glistenings in acrylic intraocular lenses
    • Miyata A, Yaguchi S. Equilibrium water content and glistenings in acrylic intraocular lenses. J Cataract Refract Surg 2004;30(8):1768 -1772.
    • (2004) J Cataract Refract Surg , vol.30 , Issue.8 , pp. 1768-1772
    • Miyata, A.1    Yaguchi, S.2
  • 21
    • 79952936233 scopus 로고    scopus 로고
    • Observation of whitening by cryo-focused ion beam scanning electron microscopy
    • Matsushima H, Katsuki Y, Mukai K, Nagata M, Senoo T. Observation of whitening by cryo-focused ion beam scanning electron microscopy. J Cataract Refract Surg 2011;37(4): 788-789.
    • (2011) J Cataract Refract Surg , vol.37 , Issue.4 , pp. 788-789
    • Matsushima, H.1    Katsuki, Y.2    Mukai, K.3    Nagata, M.4    Senoo, T.5
  • 22
    • 72149088756 scopus 로고    scopus 로고
    • Analysis of surface whitening of extracted hydrophobic acrylic intraocular lenses
    • Matsusima H, Mukai K, Nagata M, Gotoh N, Matsui E, Senoo T. Analysis of surface whitening of extracted hydrophobic acrylic intraocular lenses. J Cataract Refract Surg 2009;35(11):1927-1934.
    • (2009) J Cataract Refract Surg , vol.35 , Issue.11 , pp. 1927-1934
    • Matsusima, H.1    Mukai, K.2    Nagata, M.3    Gotoh, N.4    Matsui, E.5    Senoo, T.6
  • 23
    • 0029964482 scopus 로고    scopus 로고
    • Visual significance of glistenings seen in the AcrySof intraocular lens
    • Dhaliwal DK, Mamalis N, Olson R, et al. Visual significance of glistenings seen in the AcrySof intraocular lens. J Cataract Refract Surg 1996;22(4):452-457.
    • (1996) J Cataract Refract Surg , vol.22 , Issue.4 , pp. 452-457
    • Dhaliwal, D.K.1    Mamalis, N.2    Olson, R.3
  • 24
    • 0034751498 scopus 로고    scopus 로고
    • Effects on visual function of glistenings and folding marks in AcrySof intraocular lenses
    • Gunenc U, Oner FH, Tongai S, Ferliel M. Effects on visual function of glistenings and folding marks in AcrySof intraocular lenses. J Cataract Refract Surg 2001;27(10):1611-1614.
    • (2001) J Cataract Refract Surg , vol.27 , Issue.10 , pp. 1611-1614
    • Gunenc, U.1    Oner, F.H.2    Tongai, S.3    Ferliel, M.4
  • 25
    • 0034852629 scopus 로고    scopus 로고
    • Influence of glistenings on the optical quality of acrylic foldable intraocular lens
    • Oshika T, Shiokawa Y, Amano S, Mitono K. Influence of glistenings on the optical quality of acrylic foldable intraocular lens. Br J Ophthalmol 2001;85(9):1034 -1037.
    • (2001) Br J Ophthalmol , vol.85 , Issue.9 , pp. 1034-1037
    • Oshika, T.1    Shiokawa, Y.2    Amano, S.3    Mitono, K.4
  • 26
    • 66149124536 scopus 로고    scopus 로고
    • Comparison of postoperative surface light scattering of different intraocular lenses
    • Miyata K, Otani S, Nejima R, et al. Comparison of postoperative surface light scattering of different intraocular lenses. Br J Ophthalmol 2009;93(5):684-687.
    • (2009) Br J Ophthalmol , vol.93 , Issue.5 , pp. 684-687
    • Miyata, K.1    Otani, S.2    Nejima, R.3
  • 27
    • 0033772861 scopus 로고    scopus 로고
    • Fourier analysis of irregular astigmatism after implantation of 3 types of intraocular lenses
    • Hayashi K, Hayashi H, Oshika T, Hayashi F. Fourier analysis of irregular astigmatism after implantation of 3 types of intraocular lenses. J Cataract Refract Surg 2000;26:1510-1516.
    • (2000) J Cataract Refract Surg , vol.26 , pp. 1510-1516
    • Hayashi, K.1    Hayashi, H.2    Oshika, T.3    Hayashi, F.4
  • 28
    • 78649527775 scopus 로고    scopus 로고
    • Clinical evaluation of the transparency of hydrophobic acrylic intraocular lens optics
    • Nagata M, Matsushima H, Mukai K, et al. Clinical evaluation of the transparency of hydrophobic acrylic intraocular lens optics. J Cataract Refract Surg 2010; 36(12):2056 -2060.
    • (2010) J Cataract Refract Surg , vol.36 , Issue.12 , pp. 2056-2060
    • Nagata, M.1    Matsushima, H.2    Mukai, K.3
  • 29
    • 24944579209 scopus 로고    scopus 로고
    • Posterior capsule opacification in the presence of an intraocular lens with a sharp versus rounded optic edge
    • Hayashi K, Hayashi H. Posterior capsule opacification in the presence of an intraocular lens with a sharp versus rounded optic edge. Ophthalmology 2005;112(9):1550 -1556.
    • (2005) Ophthalmology , vol.112 , Issue.9 , pp. 1550-1556
    • Hayashi, K.1    Hayashi, H.2
  • 30
    • 65349118089 scopus 로고    scopus 로고
    • Correlation of higherorder wavefront aberrations with visual function in pseudophakic eyes
    • Hayashi K, Yoshida M, Hayashi H. Correlation of higherorder wavefront aberrations with visual function in pseudophakic eyes. Eye 2008;22(12):1476 -1482.
    • (2008) Eye , vol.22 , Issue.12 , pp. 1476-1482
    • Hayashi, K.1    Yoshida, M.2    Hayashi, H.3
  • 31
    • 0035790429 scopus 로고    scopus 로고
    • Compensation of corneal aberrations by the internal optics in the human eye
    • Artal P, Guirao A, Berrio E, Williams DR. Compensation of corneal aberrations by the internal optics in the human eye. J Vis 2001;1(1):1-8.
    • (2001) J Vis , vol.1 , Issue.1 , pp. 1-8
    • Artal, P.1    Guirao, A.2    Berrio, E.3    Williams, D.R.4
  • 32
    • 0141920544 scopus 로고    scopus 로고
    • Optical aberrations of intraocular lenses measured in vivo and in vitro
    • Barbero S, Marcos S, Jimenez-Alfaro I. Optical aberrations of intraocular lenses measured in vivo and in vitro. J Opt Soc Am Opt Image Sci Vis 2003;20(10):1841-1851.
    • (2003) J Opt Soc Am Opt Image Sci Vis , vol.20 , Issue.10 , pp. 1841-1851
    • Barbero, S.1    Marcos, S.2    Jimenez-Alfaro, I.3
  • 33
    • 49649127434 scopus 로고    scopus 로고
    • Unusual pattern of glistening formation on a 3-piece hydrophobic acrylic intraocular lens
    • Werner L, Storsberg J, Chem D, et al. Unusual pattern of glistening formation on a 3-piece hydrophobic acrylic intraocular lens. J Cataract Refract Surg 2008;34(9): 1604 -1609.
    • (2008) J Cataract Refract Surg , vol.34 , Issue.9 , pp. 1604-1609
    • Werner, L.1    Storsberg, J.2    Chem, D.3
  • 34
    • 61349084987 scopus 로고    scopus 로고
    • Posterior capsule opacification and neodymium: YAG laser capsulotomy rates with a rounded-edged silicone and a sharp-edged hydrophobic acrylic intraocular lens 10 years after surgery
    • Vock L, Menapace R, Stifter E, Georgopoulos M, Sacu S, Büehl W. Posterior capsule opacification and neodymium: YAG laser capsulotomy rates with a rounded-edged silicone and a sharp-edged hydrophobic acrylic intraocular lens 10 years after surgery. J Cataract Refract Surg 2009(3); 35:459-465.
    • (2009) J Cataract Refract Surg , vol.3 , Issue.35 , pp. 459-465
    • Vock, L.1    Menapace, R.2    Stifter, E.3    Georgopoulos, M.4    Sacu, S.5    Büehl, W.6
  • 35
    • 72149097090 scopus 로고    scopus 로고
    • Comparison of posterior capsule opacification development with 3 intraocular lens types: Five year prospective study
    • Rönbeck M, Zetterström C, Wejde G, Kugelberg M. Comparison of posterior capsule opacification development with 3 intraocular lens types: five year prospective study. J Cataract Refract Surg 2009;35(11):1935-1940.
    • (2009) J Cataract Refract Surg , vol.35 , Issue.11 , pp. 1935-1940
    • Rönbeck, M.1    Zetterström, C.2    Wejde, G.3    Kugelberg, M.4
  • 36
    • 62649160387 scopus 로고    scopus 로고
    • Posterior capsule opacification in silicone and hydrophobic acrylic intraocular lenses with sharp-edge optics six years after surgery
    • Vock L, Crnej A, Findl O, et al. Posterior capsule opacification in silicone and hydrophobic acrylic intraocular lenses with sharp-edge optics six years after surgery. Am J Ophthalmol 2009;147(4):683-690.
    • (2009) Am J Ophthalmol , vol.147 , Issue.4 , pp. 683-690
    • Vock, L.1    Crnej, A.2    Findl, O.3
  • 37
    • 42649097233 scopus 로고    scopus 로고
    • Effect of AcrySof versus silicone or polymethyl methacrylate intraocular lens on posterior capsule opacification
    • Li N, Chen X, Zhang J, et al. Effect of AcrySof versus silicone or polymethyl methacrylate intraocular lens on posterior capsule opacification. Ophthalmology 2008;115(5):830-838.
    • (2008) Ophthalmology , vol.115 , Issue.5 , pp. 830-838
    • Li, N.1    Chen, X.2    Zhang, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.