메뉴 건너뛰기




Volumn 29, Issue 7, 2003, Pages 1385-1388

Surface scattering in implanted hydrophobic intraocular lenses

Author keywords

[No Author keywords available]

Indexed keywords

POLYACRYLIC ACID;

EID: 0041704570     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0886-3350(02)01994-6     Document Type: Article
Times cited : (68)

References (14)
  • 1
    • 0036734316 scopus 로고    scopus 로고
    • Practice styles and preferences of ASCRS members - 2001 Survey
    • Leaming DV. Practice styles and preferences of ASCRS members - 2001 survey. J Cataract Refract Surg 2000; 28:1681-1688
    • (2000) J Cataract Refract Surg , vol.28 , pp. 1681-1688
    • Leaming, D.V.1
  • 2
    • 0031596652 scopus 로고    scopus 로고
    • Biocompatibility of poly(methyl methacrylate), silicone, and AcrySof intraocular lenses: Randomized comparison of the cellular reaction on the anterior lens surface
    • Hollick EJ, Spalton DJ, Ursell PG, Pande MV. Biocompatibility of poly(methyl methacrylate), silicone, and AcrySof intraocular lenses: randomized comparison of the cellular reaction on the anterior lens surface. J Cataract Refract Surg 1998; 24:361-366
    • (1998) J Cataract Refract Surg , vol.24 , pp. 361-366
    • Hollick, E.J.1    Spalton, D.J.2    Ursell, P.G.3    Pande, M.V.4
  • 3
    • 0031471972 scopus 로고    scopus 로고
    • Anterior capsule stability in eyes with intraocular lenses made of poly(methyl methacrylate), silicone, and AcrySof
    • Ursell PG, Spalton DJ, Pande MV. Anterior capsule stability in eyes with intraocular lenses made of poly(methyl methacrylate), silicone, and AcrySof. J Cataract Refract Surg 1997; 23:1532-1538
    • (1997) J Cataract Refract Surg , vol.23 , pp. 1532-1538
    • Ursell, P.G.1    Spalton, D.J.2    Pande, M.V.3
  • 4
    • 0031899326 scopus 로고    scopus 로고
    • Relationship between intraocular lens biomaterials and posterior capsule opacification
    • Ursell PG, Spalton DJ, Pande MV, et al. Relationship between intraocular lens biomaterials and posterior capsule opacification. J Cataract Refract Surg 1998; 24:352-360
    • (1998) J Cataract Refract Surg , vol.24 , pp. 352-360
    • Ursell, P.G.1    Spalton, D.J.2    Pande, M.V.3
  • 5
    • 0033795712 scopus 로고    scopus 로고
    • Clinical assessment of long-term safety and efficacy of a widely implanted polyacrylic intraocular lens material
    • Kobayashi H, Ikeda H, Imamura S, et al. Clinical assessment of long-term safety and efficacy of a widely implanted polyacrylic intraocular lens material. Am J Ophthalmol 2000; 130:310-321
    • (2000) Am J Ophthalmol , vol.130 , pp. 310-321
    • Kobayashi, H.1    Ikeda, H.2    Imamura, S.3
  • 6
    • 0032100759 scopus 로고    scopus 로고
    • In vivo quantitative measurement of posterior capsule opacification after extracapsular cataract surgery
    • Hayashi K, Hayashi H, Nakao F, Hayashi F. In vivo quantitative measurement of posterior capsule opacification after extracapsular cataract surgery. Am J Ophthalmol 1998; 125:837-843
    • (1998) Am J Ophthalmol , vol.125 , pp. 837-843
    • Hayashi, K.1    Hayashi, H.2    Nakao, F.3    Hayashi, F.4
  • 7
    • 0032881328 scopus 로고    scopus 로고
    • Effect of tranilast eyedrops in preventing posterior capsule opacification: Preliminary report
    • Tobari I, Iwaki Y, Miyake K. Effect of tranilast eyedrops in preventing posterior capsule opacification: preliminary report. J Cataract Refract Surg 1999; 25:1394-1399
    • (1999) J Cataract Refract Surg , vol.25 , pp. 1394-1399
    • Tobari, I.1    Iwaki, Y.2    Miyake, K.3
  • 8
    • 0031916642 scopus 로고    scopus 로고
    • In vitro analysis of AcrySof intraocular lens glistenings in AcryPak and Wagon Wheel packaging
    • Omar O, Pirayesh A, Mamalis N, Olson RJ. In vitro analysis of AcrySof intraocular lens glistenings in AcryPak and Wagon Wheel packaging. J Cataract Refract Surg 1998; 24:107-113
    • (1998) J Cataract Refract Surg , vol.24 , pp. 107-113
    • Omar, O.1    Pirayesh, A.2    Mamalis, N.3    Olson, R.J.4
  • 9
    • 0025991283 scopus 로고
    • Ultrastructural study of adsorbed protein on extracted intraocular lenses
    • Shigemitsu T. Ultrastructural study of adsorbed protein on extracted intraocular lenses. Jpn J Ophthalmol 1991; 35:354-358
    • (1991) Jpn J Ophthalmol , vol.35 , pp. 354-358
    • Shigemitsu, T.1
  • 10
    • 0033485845 scopus 로고    scopus 로고
    • Lens epithelial cell layer formation related to hydrogel foldable intraocular lenses
    • Koch MU, Kalicharan D, van der Want JJL. Lens epithelial cell layer formation related to hydrogel foldable intraocular lenses. J Cataract Refract Surg 1999; 25:1637-1640
    • (1999) J Cataract Refract Surg , vol.25 , pp. 1637-1640
    • Koch, M.U.1    Kalicharan, D.2    Van der Want, J.J.L.3
  • 11
    • 0032779836 scopus 로고    scopus 로고
    • Surface cytologic features on intraocular lenses; can increased biocompatibility have disadvantages?
    • Hollick EJ, Spalton DJ, Ursell PG. Surface cytologic features on intraocular lenses; can increased biocompatibility have disadvantages? Arch Ophthalmol 1999; 117:872-878
    • (1999) Arch Ophthalmol , vol.117 , pp. 872-878
    • Hollick, E.J.1    Spalton, D.J.2    Ursell, P.G.3
  • 12
    • 0023760017 scopus 로고
    • Light scattering caused by cells on the intraocular lens
    • Fukaya Y, Hara T, Hara T, Iwata S. Light scattering caused by cells on the intraocular lens. J Cataract Refract Surg 1988; 14:396-399
    • (1988) J Cataract Refract Surg , vol.14 , pp. 396-399
    • Fukaya, Y.1    Hara, T.2    Hara, T.3    Iwata, S.4
  • 14
    • 0022560291 scopus 로고
    • Streulicht bei implantierten kunststofflinsen im modellversuch
    • Aust W. Streulicht bei implantierten Kunststofflinsen im Modellversuch. Klin Monatsbl Augenheilkd 1986; 188: 69-71
    • (1986) Klin Monatsbl Augenheilkd , vol.188 , pp. 69-71
    • Aust, W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.