Volumn 20, Issue 2, 2012, Pages 131-140

Compton spectroscopy for rotation-mode computed tomography

Author keywords

Compton spectroscopy; computed tomography; rotation mode; X ray spectrum

Indexed keywords

COMPTON; COMPTON SPECTROSCOPY; COMPUTED TOMOGRAPHY; CT IMAGING; CT SYSTEM; HEAVY-ION THERAPY; PRACTICAL SOLUTIONS; PRIMARY SPECTRA; ROTATION MODE; SECONDARY BEAMS; X RAY SPECTRUM; X-RAY ENERGIES;

EID: 84866140223     PISSN: 08953996     EISSN: None     Source Type: Journal    
DOI: 10.3233/XST-2012-0324     Document Type: Article
Times cited : (1)

References (16)
  • 1
    • 0017194431 scopus 로고
    • Spectroscopy of diagnostic x ray by a Compton-scatter method
    • M. Yaffe, K.W. Taylor and H.E. Johns, Spectroscopy of diagnostic x ray by a Compton-scatter method, Med Phy 3 (1976), 328-334.
    • (1976) Med Phy , vol.3 , pp. 328-334
    • Yaffe, M.1    Taylor, K.W.2    Johns, H.E.3
  • 2
    • 0023229176 scopus 로고
    • A Compton scattering spectrometer for determining X-ray photon energy spectra
    • G.Matscheko and R. Ribberfors, A Compton scattering spectrometer for determining X-ray photon energy spectra, Phys Med Biol 32 (1987), 577-594.
    • (1987) Phys Med Biol , vol.32 , pp. 577-594
    • Matscheko, G.1    Ribberfors, R.2
  • 3
    • 0024491675 scopus 로고
    • Compton spectroscopy in the diagnostic x-ray energy range. I. Spectrometer design
    • G. Matscheko and G.A. Carlsso, Compton spectroscopy in the diagnostic x-ray energy range. I. Spectrometer design, Phys Med Biol 34 (1989), 185-197.
    • (1989) Phys Med Biol , vol.34 , pp. 185-197
    • Matscheko, G.1    Carlsso, G.A.2
  • 4
    • 0024558620 scopus 로고
    • Compton spectroscopy in the diagnostic x-ray energy range. II. Effects of scattering material and energy resolution
    • G. Matscheko, G.A. Carlsson and R. Ribberfors, Compton spectroscopy in the diagnostic x-ray energy range. II. Effects of scattering material and energy resolution, Phys Med Biol 34 (1989), 199-208.
    • (1989) Phys Med Biol , vol.34 , pp. 199-208
    • Matscheko, G.1    Carlsson, G.A.2    Ribberfors, R.3
  • 5
    • 84866104257 scopus 로고    scopus 로고
    • Simulation models to obtain X-ray spectra using the Compton scattering technique
    • J. Rodenas, S. Gallardo and M.C. Burgos, Simulation models to obtain X-ray spectra using the Compton scattering technique, Proceedings of the Physics and Control 1 (2003), 228-231.
    • (2003) Proceedings of the Physics and Control , vol.1 , pp. 228-231
    • Rodenas, J.1    Gallardo, S.2    Burgos, M.C.3
  • 8
    • 3142736392 scopus 로고    scopus 로고
    • Monte Carlo simulation of the Compton scattering technique applied to characterize diagnostic x-ray spectra
    • S.Gallardo, J. Rodenas and G.Verdu, Monte Carlo simulation of the Compton scattering technique applied to characterize diagnostic x-ray spectra, Med Phys 31 (2004), 2082-2090.
    • (2004) Med Phys , vol.31 , pp. 2082-2090
    • Gallardo, S.1    Rodenas, J.2    Verdu, G.3
  • 10
    • 0024499846 scopus 로고
    • Measurements of absolute energy spectra from a clinical CT machine under working conditions using a Compton spectrometer
    • G. Matscheko and G.A. Carlsson, Measurements of absolute energy spectra from a clinical CT machine under working conditions using a Compton spectrometer, Phys Med Biol 34 (1989), 209-222.
    • (1989) Phys Med Biol , vol.34 , pp. 209-222
    • Matscheko, G.1    Carlsson, G.A.2
  • 11
    • 51349104871 scopus 로고    scopus 로고
    • A Monte Carlo study of the accuracy of CT-numbers for range calculations in Carbon ion therapy
    • PhD thesis
    • S. Qamhiyeh, A Monte Carlo study of the accuracy of CT-numbers for range calculations in Carbon ion therapy. 2007, PhD thesis, Ruperto-Carola University of Heidelberg.
    • (2007) Ruperto-Carola University of Heidelberg
    • Qamhiyeh, S.1
  • 12
    • 8544271686 scopus 로고    scopus 로고
    • Monte Carlo simulation of x-ray spectra in diagnostic radiology and mammography using MCNP4C
    • M.R. Ay, M. Shahriari, S. Sarkar, M. Adib and H. Zaidi, Monte Carlo simulation of x-ray spectra in diagnostic radiology and mammography using MCNP4C, Med Biol 49 (2004), 4897-4917.
    • (2004) Med Biol , vol.49 , pp. 4897-4917
    • Ay, M.R.1    Shahriari, M.2    Sarkar, S.3    Adib, M.4    Zaidi, H.5
  • 13
    • 0018399326 scopus 로고
    • Computation of Bremsstrahlung X-ray spectra and comparison with spectra measured with a Ge(Li) detector
    • R. Birch and M. Marshall, Computation of Bremsstrahlung X-ray spectra and comparison with spectra measured with a Ge(Li) detector, Phys Med Biol 24 (1979), 505-517.
    • (1979) Phys Med Biol , vol.24 , pp. 505-517
    • Birch, R.1    Marshall, M.2
  • 14
    • 23844486770 scopus 로고    scopus 로고
    • X-ray spectrum of CT system acquired by Compton spectroscopy using high resolution Schottky CdTe detector
    • K. Maeda and M. Matsumoto, X-ray spectrum of CT system acquired by Compton spectroscopy using high resolution Schottky CdTe detector, Proceedings of the SPIE 5745 (2005), 1229-1236.
    • (2005) Proceedings of the SPIE 5745 , pp. 1229-1236
    • Maeda, K.1    Matsumoto, M.2
  • 15
    • 84866137905 scopus 로고    scopus 로고
    • Effects of scatterer material and position dependence on X-ray CT spectra measured by Compton spectroscopy
    • N. Wakai, Y. Matsuyama and M. Matsumoto, Effects of scatterer material and position dependence on X-ray CT spectra measured by Compton spectroscopy, Med Phys 27 (2007), 96-97.
    • (2007) Med Phys , vol.27 , pp. 96-97
    • Wakai, N.1    Matsuyama, Y.2    Matsumoto, M.3
  • 16
    • 70449371671 scopus 로고    scopus 로고
    • Investigation of the response function of the Schottky CdTe detector with guard-ring cathode through Monte Carlo calculation and measurement
    • A. Mohammadi, M. Baba and H. Ohuchi, Investigation of the response function of the Schottky CdTe detector with guard-ring cathode through Monte Carlo calculation and measurement, Journal of Radiation Safety management 6 (2007), 14-17
    • (2007) Journal of Radiation Safety Management , vol.6 , pp. 14-17
    • Mohammadi, A.1    Baba, M.2    Ohuchi, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.