메뉴 건너뛰기




Volumn 116, Issue 1-4, 2005, Pages 627-630

Assessment of mammography spectra using compton spectrometry techniques

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ANALYTIC METHOD; ARTICLE; COMPTON EFFECT; CONTROLLED STUDY; IMAGE QUALITY; MAMMOGRAPHY; METHODOLOGY; MONTE CARLO METHOD; QUALITY CONTROL; RADIATION DETECTION; RADIATION DOSE; RADIATION DOSE DISTRIBUTION; SIMULATION; SPECTROMETER; X RAY SPECTROMETRY;

EID: 31544442457     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/nci243     Document Type: Article
Times cited : (2)

References (13)
  • 1
    • 0031693491 scopus 로고    scopus 로고
    • Mammography spectrum measurement using an x-ray diffraction device
    • Boone, J. M., Yu, T. and Siebert, A. Mammography spectrum measurement using an x-ray diffraction device. Phys. Med. Biol. 43, 2569-2582 (1998).
    • (1998) Phys. Med. Biol. , vol.43 , pp. 2569-2582
    • Boone, J.M.1    Yu, T.2    Siebert, A.3
  • 2
    • 0035011178 scopus 로고    scopus 로고
    • A comparison of mammography spectral measurements with spectra produced using several different mathematical models
    • Wilkinson, L. E., Johnston, P. N. and Heggie, J. C. P. A comparison of mammography spectral measurements with spectra produced using several different mathematical models. Phys. Med. Biol. 46, 1575-1589 (2001).
    • (2001) Phys. Med. Biol. , vol.46 , pp. 1575-1589
    • Wilkinson, L.E.1    Johnston, P.N.2    Heggie, J.C.P.3
  • 3
    • 3142720828 scopus 로고    scopus 로고
    • Diagnostic quality and absorbed dose in mammography. Influence of X-ray spectra and breast anatomy
    • Ph.D. thesis, Department of Radiation Physics, University of Göteborg, Sweden
    • Thilander Klang, A. Diagnostic quality and absorbed dose in mammography. Influence of X-ray spectra and breast anatomy. Ph.D. thesis, Department of Radiation Physics, University of Göteborg, Sweden (1997).
    • (1997)
    • Thilander Klang, A.1
  • 4
    • 0004123520 scopus 로고    scopus 로고
    • Germanium Detectors. Canberra Industries, USA
    • Germanium Detectors. User's Manual. Canberra Industries, USA (1998).
    • (1998) User's Manual
  • 5
    • 0002765166 scopus 로고    scopus 로고
    • A Compton spectrometer for measurements of primary photon energy spectra from clinical X-ray units under working conditions
    • Ph.D. thesis, Department of radiation physics, Linköping University, Linköping, Sweden
    • Matscheko, G. A Compton spectrometer for measurements of primary photon energy spectra from clinical X-ray units under working conditions. Ph.D. thesis, Department of radiation physics, Linköping University, Linköping, Sweden (1998).
    • (1998)
    • Matscheko, G.1
  • 7
    • 3142736392 scopus 로고    scopus 로고
    • Monte Carlo simulation of the Compton scattering technique applied to characterise diagnostic X-ray spectra
    • Gallardo, S., Ródenas, J. and Verdú, G. Monte Carlo simulation of the Compton scattering technique applied to characterise diagnostic X-ray spectra. Med. Phys. 31, 2082-2090 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 2082-2090
    • Gallardo, S.1    Ródenas, J.2    Verdú, G.3
  • 9
    • 0004152630 scopus 로고    scopus 로고
    • Catalogue of diagnostic x-ray spectra and other data
    • IPEM Report 78 (York: IPEM)
    • Cranley, K., Gilmore, B., Fogarty, G. and Desponds, L. Catalogue of diagnostic x-ray spectra and other data. IPEM Report 78 (York: IPEM) (1997).
    • (1997)
    • Cranley, K.1    Gilmore, B.2    Fogarty, G.3    Desponds, L.4
  • 10
    • 0004236492 scopus 로고    scopus 로고
    • 3rd edn. (Baltimore, MD, The Johns Hopkins Unviersity Press)
    • Golub, G. H. and Van Loan, C. F. Matrix Computations, 3rd edn. (Baltimore, MD, The Johns Hopkins Unviersity Press) (1996).
    • (1996) Matrix Computations
    • Golub, G.H.1    Van Loan, C.F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.