-
1
-
-
33846337181
-
Radiofrequency ablation permits an effective treatment for colorectal liver metastasis
-
Abitabile P, Hartl U, Lange J, Maurer CA. Radiofrequency ablation permits an effective treatment for colorectal liver metastasis. Eur J Surg Oncol 2007;33:67-71.
-
(2007)
Eur J Surg Oncol
, vol.33
, pp. 67-71
-
-
Abitabile, P.1
Hartl, U.2
Lange, J.3
Maurer, C.A.4
-
2
-
-
0033562656
-
Percutaneous radiofrequency interstitial thermal ablation of small hepatocellular carcinoma
-
Allgaier HP, Deibert P, Zuber I, Olschewski M, Blum HE. Percutaneous radiofrequency interstitial thermal ablation of small hepatocellular carcinoma. Lancet 1999;353:1676-7.
-
(1999)
Lancet
, vol.353
, pp. 1676-1677
-
-
Allgaier, H.P.1
Deibert, P.2
Zuber, I.3
Olschewski, M.4
Blum, H.E.5
-
3
-
-
33745282727
-
Long-term survival after radiofrequency ablation of complex unresectable liver tumors
-
Amersi FF, McElrath-Garza A, Ahmad A, Zogakis T, Allegra DP, Krasne R, et al. Long-term survival after radiofrequency ablation of complex unresectable liver tumors. Arch Surg 2006;141:581-8.
-
(2006)
Arch Surg
, vol.141
, pp. 581-588
-
-
Amersi, F.F.1
McElrath-Garza, A.2
Ahmad, A.3
Zogakis, T.4
Allegra, D.P.5
Krasne, R.6
-
4
-
-
40849092809
-
Overcoming the heat-sink phenomenon: Successful radiofrequency thermal ablation of liver tumors in contact with blood vessels
-
Thanos L, Mylona S, Galani P, Pomoni A, Koskinas I. Overcoming the heat-sink phenomenon: successful radiofrequency thermal ablation of liver tumors in contact with blood vessels. Diagn Interv Radiol 2008;14:51-6.
-
(2008)
Diagn Interv Radiol
, vol.14
, pp. 51-56
-
-
Thanos, L.1
Mylona, S.2
Galani, P.3
Pomoni, A.4
Koskinas, I.5
-
5
-
-
62949221086
-
CT-guided radiofrequency ablation for hepatocellular carcinomas that were undetectable at US: Therapeutic effectiveness and safety
-
Park BJ, Byun JH, Jin YH, Won HJ, Shin YM, Kim KW, et al. CT-guided radiofrequency ablation for hepatocellular carcinomas that were undetectable at US: Therapeutic effectiveness and safety. J Vasc Interv Radiol 2009;20:490-9.
-
(2009)
J Vasc Interv Radiol
, vol.20
, pp. 490-499
-
-
Park, B.J.1
Byun, J.H.2
Jin, Y.H.3
Won, H.J.4
Shin, Y.M.5
Kim, K.W.6
-
6
-
-
70350566119
-
Thermal ablation a comparison of thermal dose required for radio-frequency-, microwave-, and laser-induced coagulation in an ex-vivo bovine liver model
-
Mertyna P, Goldberg W, Yang W, Goldberg SN. Thermal ablation a comparison of thermal dose required for radio-frequency-, microwave-, and laser-induced coagulation in an ex-vivo bovine liver model. Acad Radiol 2009;16:1539-48.
-
(2009)
Acad Radiol
, vol.16
, pp. 1539-1548
-
-
Mertyna, P.1
Goldberg, W.2
Yang, W.3
Goldberg, S.N.4
-
7
-
-
28544448874
-
Comparison of cryoablation, radiofrequency ablation and high-intensity focused ultrasound for treating small renal tumors
-
Weld KJ, Landman J. Comparison of cryoablation, radiofrequency ablation and high-intensity focused ultrasound for treating small renal tumors. BJU Int 2005;96:1224-9.
-
(2005)
BJU Int
, vol.96
, pp. 1224-1229
-
-
Weld, K.J.1
Landman, J.2
-
8
-
-
0034853643
-
Image radiofrequency tumor ablation: Challenges and opportunities - Part 1
-
Goldberg SN, Dupuy DE. Image radiofrequency tumor ablation: challenges and opportunities - part 1. J Vasc Interv Eadiol 2001;12:1021-32.
-
(2001)
J Vasc Interv Eadiol
, vol.12
, pp. 1021-1032
-
-
Goldberg, S.N.1
Dupuy, D.E.2
-
9
-
-
0032521469
-
Practical limitation of interstitial thermometry during deep hyperthermia
-
Van der Zee J, Peer-Valstar JN, Rietveld PJ, de Graaf- Strukowska L, van Rhoon GC. Practical limitation of interstitial thermometry during deep hyperthermia. Int J Radiation Oncology Biol Phys 1998;40:1205-12.
-
(1998)
Int J Radiation Oncology Biol Phys
, vol.40
, pp. 1205-1212
-
-
Van Der Zee, J.1
Peer-Valstar, J.N.2
Rietveld, P.J.3
De Graaf-Strukowska, L.4
Van Rhoon, G.C.5
-
10
-
-
0032527945
-
Rationale for using invasive thermometry for regional hyperthermia of pelvic tumors
-
Wust P, Gellerman J, Harder C, Tilly W, Rau B, Dinges S, et al. Rationale for using invasive thermometry for regional hyperthermia of pelvic tumors. Int J Radiation Oncology Biol Phys 1998;41:1129-37.
-
(1998)
Int J Radiation Oncology Biol Phys
, vol.41
, pp. 1129-1137
-
-
Wust, P.1
Gellerman, J.2
Harder, C.3
Tilly, W.4
Rau, B.5
Dinges, S.6
-
11
-
-
0034010360
-
Microwave radiometric thermometry andits potential applicability to ablative therapy
-
Wang SS, VanderBrink BA, Regan J, Carr K, Link MS, Homoud MK, et al. Microwave radiometric thermometry andits potential applicability to ablative therapy. J Interv Card Electrophysiol 2000;4:295-300.
-
(2000)
J Interv Card Electrophysiol
, vol.4
, pp. 295-300
-
-
Wang, S.S.1
VanderBrink, B.A.2
Regan, J.3
Carr, K.4
Link, M.S.5
Homoud, M.K.6
-
12
-
-
0041590978
-
Real-time MR temperature mapping of rabbit liver in vivo during thermal ablation
-
Weidensteiner C, Quesson B, Caire-Gana B, Kerioui N, Rullier A, Trillaud H, et al. Real-time MR temperature mapping of rabbit liver in vivo during thermal ablation. Magn Reson Med 2003;50:322-30.
-
(2003)
Magn Reson Med
, vol.50
, pp. 322-330
-
-
Weidensteiner, C.1
Quesson, B.2
Caire-Gana, B.3
Kerioui, N.4
Rullier, A.5
Trillaud, H.6
-
13
-
-
33745686043
-
Real time monitoring of radiofrequency ablation of rabbit liver by respiratory gated quantitative temperature MRI
-
Lepetit-Coiffe M, Quesson B, Seror O, Dumont E, Bail BL, Moonen CTW, et al. Real time monitoring of radiofrequency ablation of rabbit liver by respiratory gated quantitative temperature MRI. J Magn Reson Imaging 2006;24:152-9.
-
(2006)
J Magn Reson Imaging
, vol.24
, pp. 152-159
-
-
Lepetit-Coiffe, M.1
Quesson, B.2
Seror, O.3
Dumont, E.4
Bail, B.L.5
Moonen, C.T.W.6
-
14
-
-
0038715618
-
Noninvasive temperature estimation based on the energy of backscattered ultrasound
-
Arthur RM, Straube WL, Starman JD, Moros EG. Noninvasive temperature estimation based on the energy of backscattered ultrasound. Med Phys 2003;30:1021-9.
-
(2003)
Med Phys
, vol.30
, pp. 1021-1029
-
-
Arthur, R.M.1
Straube, W.L.2
Starman, J.D.3
Moros, E.G.4
-
15
-
-
0029347489
-
Noninvasive estimation of tissue temperature response to heating fields using diagnostic ultrasound
-
Seip R, Ebbini ES. Noninvasive estimation of tissue temperature response to heating fields using diagnostic ultrasound. IEEE Trans Biomed Eng 1995;42:828-39.
-
(1995)
IEEE Trans Biomed Eng
, vol.42
, pp. 828-839
-
-
Seip, R.1
Ebbini, E.S.2
-
16
-
-
0019929446
-
Noninvasive thermometry with a clinical x-ray CT scanner
-
Fallone BG, Moran PR, Podgorsak EB. Noninvasive thermometry with a clinical x-ray CT scanner. Med Phys 1982;9:715-21.
-
(1982)
Med Phys
, vol.9
, pp. 715-721
-
-
Fallone, B.G.1
Moran, P.R.2
Podgorsak, E.B.3
-
17
-
-
0021147837
-
Jørgensen J. Isotherm mapping in hyperthermia using subtraction X-ray computed tomography
-
Bentzen SM, Overgaard J, Jørgensen J. Isotherm mapping in hyperthermia using subtraction X-ray computed tomography. Radiother Oncol 1984;2:255-60.
-
(1984)
Radiother Oncol
, vol.2
, pp. 255-260
-
-
Bentzen, S.M.1
Overgaard, J.2
-
19
-
-
77952497054
-
Multi-slice computed tomography: A tool for non-invasive temperature measurement?
-
Bruners P, Levit E, Penzkofer T, Isfort P, Ocklenburg C, Schmidt B, et al. Multi-slice computed tomography: A tool for non-invasive temperature measurement? Int J Hyperthermia 2010;26:359-65.
-
(2010)
Int J Hyperthermia
, vol.26
, pp. 359-365
-
-
Bruners, P.1
Levit, E.2
Penzkofer, T.3
Isfort, P.4
Ocklenburg, C.5
Schmidt, B.6
-
20
-
-
0031386774
-
CT on-line monitoring of HIFU therapy
-
Jenne JW, Bahner M, Spoo J, Huber P, Rastert R. CT on-line monitoring of HIFU therapy. IEEE Ultrason Symp 1997;2:1377-80.
-
(1997)
IEEE Ultrason Symp
, vol.2
, pp. 1377-1380
-
-
Jenne, J.W.1
Bahner, M.2
Spoo, J.3
Huber, P.4
Rastert, R.5
-
21
-
-
79957790721
-
Feasibility of noninvasive temperature assessment during radiofrequency liver ablation on computed tomography
-
Pandeya GD, Greuter MJW, de Jong KP, Schmidt B, Flohr T, Oudkerk M. Feasibility of noninvasive temperature assessment during radiofrequency liver ablation on computed tomography. J Comput Assist Tomogr 2011;35:356-60.
-
(2011)
J Comput Assist Tomogr
, vol.35
, pp. 356-360
-
-
Pandeya, G.D.1
Greuter, M.J.W.2
De Jong, K.P.3
Schmidt, B.4
Flohr, T.5
Oudkerk, M.6
-
22
-
-
80052668505
-
Feasibility of computed tomography based thermometry during interstitial laser heating in bovine liver
-
Pandeya GD, Klaessens JHGM, Greuter MJW, Schmidt B, Flohr T, van Hillegersberg R, et al. Feasibility of computed tomography based thermometry during interstitial laser heating in bovine liver. Eur Radiol 2011;21:1733-8.
-
(2011)
Eur Radiol
, vol.21
, pp. 1733-1738
-
-
Pandeya, G.D.1
Klaessens, J.H.G.M.2
Greuter, M.J.W.3
Schmidt, B.4
Flohr, T.5
Van Hillegersberg, R.6
-
23
-
-
77950604342
-
Estimating effective dose for CT using dose-length product compared with using organ doses: Consequences of adopting International Commission on Radiological Protection publication 103 or dual-energy scanning
-
Christner JA, Kofler JM, McCollough CH. Estimating effective dose for CT using dose-length product compared with using organ doses: consequences of adopting International Commission on Radiological Protection publication 103 or dual-energy scanning. AJR Am J Roentgenol 2010;194:881-9.
-
(2010)
AJR Am J Roentgenol
, vol.194
, pp. 881-889
-
-
Christner, J.A.1
Kofler, J.M.2
McCollough, C.H.3
-
24
-
-
32144431646
-
Non-invasive thermometry for monitoring hepatic radiofrequency ablation
-
Frich L. Non-invasive thermometry for monitoring hepatic radiofrequency ablation. Minim Invasive Ther 2006;15:18-25.
-
(2006)
Minim Invasive Ther
, vol.15
, pp. 18-25
-
-
Frich, L.1
-
25
-
-
0028332615
-
Recent developments in modeling heat transfer in blood perfused tissues
-
Arkin H, Xu LX, Holmes KR. Recent developments in modeling heat transfer in blood perfused tissues. IEEE Trans Biomed Eng 1994;41:97-107.
-
(1994)
IEEE Trans Biomed Eng
, vol.41
, pp. 97-107
-
-
Arkin, H.1
Xu, L.X.2
Holmes, K.R.3
-
26
-
-
0028814576
-
Investigations of large vessel cooling during interstitial laser heating
-
Whelan WM, Wyman DR, Wilson BC. Investigations of large vessel cooling during interstitial laser heating. Med Phys 1995;22:105-15.
-
(1995)
Med Phys
, vol.22
, pp. 105-115
-
-
Whelan, W.M.1
Wyman, D.R.2
Wilson, B.C.3
-
27
-
-
34247392012
-
Investigation of the influence of blood flow rate on large vessel cooling in hepatic radiofrequency ablation
-
Welp C, Siebers S, Ermert H, Werner J. Investigation of the influence of blood flow rate on large vessel cooling in hepatic radiofrequency ablation. Biomed Tech (Berl) 2006;51:337-46.
-
(2006)
Biomed Tech (Berl)
, vol.51
, pp. 337-346
-
-
Welp, C.1
Siebers, S.2
Ermert, H.3
Werner, J.4
-
28
-
-
33745603519
-
In-vivo evaluation of a novel bipolar radiofrequency device for interstitial thermotherapy of liver tumor during normal and interrupted hepatic perfusion
-
Ritz J, Lehmann KS, Isbert C, Reissfelder C, Albrecht T, Stein T, et al. In-vivo evaluation of a novel bipolar radiofrequency device for interstitial thermotherapy of liver tumor during normal and interrupted hepatic perfusion. J Surg Res 2006;133:174-84.
-
(2006)
J Surg Res
, vol.133
, pp. 174-184
-
-
Ritz, J.1
Lehmann, K.S.2
Isbert, C.3
Reissfelder, C.4
Albrecht, T.5
Stein, T.6
-
29
-
-
29144479258
-
Dynamic modelling of photothermal interactions for laser-induced interstitial thermotherapy: Parameter sensitivity analysis
-
Jiang SC, Zhang XX. Dynamic modelling of photothermal interactions for laser-induced interstitial thermotherapy: parameter sensitivity analysis. Lasers Med Sci 2005;20:122-31.
-
(2005)
Lasers Med Sci
, vol.20
, pp. 122-131
-
-
Jiang, S.C.1
Zhang, X.X.2
-
30
-
-
0030095011
-
Radiofrequency tissue ablation: Importance of local temperature along the electrode tip exposure in determining lesion shape and size
-
Goldberg SN, Gazelle GS, Halpern EF, Rittman WJ, Mueller PR, Rosenthal DI. Radiofrequency tissue ablation: importance of local temperature along the electrode tip exposure in determining lesion shape and size. Acad Radiol 1996;3:212-18,
-
(1996)
Acad Radiol
, vol.3
, pp. 212-218
-
-
Goldberg, S.N.1
Gazelle, G.S.2
Halpern, E.F.3
Rittman, W.J.4
Mueller, P.R.5
Rosenthal, D.I.6
-
31
-
-
0018406259
-
The temperature dependence of computed tomography attenuation values
-
Bydder GM, Kreel L. The temperature dependence of computed tomography attenuation values. J Comput Assist Tomogr 1979;3:506-10,
-
(1979)
J Comput Assist Tomogr
, vol.3
, pp. 506-510
-
-
Bydder, G.M.1
Kreel, L.2
|