메뉴 건너뛰기




Volumn 11, Issue 5, 2012, Pages 441-445

Direct response to proton beam linear energy transfer (LET) in a novel polymer gel dosimeter formulation

Author keywords

Linear energy transfer; Polymer gel dosimetry; Proton therapy

Indexed keywords

POLYMER;

EID: 84865858664     PISSN: 15330346     EISSN: None     Source Type: Journal    
DOI: 10.7785/tcrt.2012.500263     Document Type: Article
Times cited : (13)

References (19)
  • 3
    • 0034636889 scopus 로고    scopus 로고
    • Response of multiwire proportional counter for energy loss measurement
    • Kohno, T., Kiyota, T., Matsufuji, N., Futami, Y., Kanai, T. Response of multiwire proportional counter for energy loss measurement. Nucl Instrum Meth A 450, 456-466 (2000).
    • (2000) Nucl Instrum Meth A , vol.450 , pp. 456-466
    • Kohno, T.1    Kiyota, T.2    Matsufuji, N.3    Futami, Y.4    Kanai, T.5
  • 4
    • 9244221609 scopus 로고    scopus 로고
    • Comparisons of LET distributions for protons with energies between 50 and 200 MeV determined using a spherical tissue-equivalent proportional counter (TEPC) and a position-sensitive silicon spectrometer (RRMD-III)
    • Borak, T. B., Doke, T., Fuse, T., Guetersloh, S., Heilbronn, L., Hara, K., Moyers, M., Suzuki, S., Taddei, P., Terasawa, K., Zeitlin, C. J. Comparisons of LET distributions for protons with energies between 50 and 200 MeV determined using a spherical tissue-equivalent proportional counter (TEPC) and a position-sensitive silicon spectrometer (RRMD-III). Radiat Res 162, 687-692 (2004).
    • (2004) Radiat Res , vol.162 , pp. 687-692
    • Borak, T.B.1    Doke, T.2    Fuse, T.3    Guetersloh, S.4    Heilbronn, L.5    Hara, K.6    Moyers, M.7    Suzuki, S.8    Taddei, P.9    Terasawa, K.10    Zeitlin, C.J.11
  • 6
    • 4644294473 scopus 로고    scopus 로고
    • Passive spectrometry of linear energy transfer: Development and use
    • Spurny, F., Molokanov, A. G., Bamblevski, V. P. Passive spectrometry of linear energy transfer: development and use. Radiat Prot Dosimetry 110, 675-679 (2004).
    • (2004) Radiat Prot Dosimetry , vol.110 , pp. 675-679
    • Spurny, F.1    Molokanov, A.G.2    Bamblevski, V.P.3
  • 7
    • 33749820744 scopus 로고    scopus 로고
    • Dosimetry of densely ionising radiation with three LiF phosphors for space applications
    • Bilski, P. Dosimetry of densely ionising radiation with three LiF phosphors for space applications. Radiat Prot Dosimetry 120, 397-400 (2006).
    • (2006) Radiat Prot Dosimetry , vol.120 , pp. 397-400
    • Bilski, P.1
  • 10
    • 4644290784 scopus 로고    scopus 로고
    • Linear energy transfer dependence of a normoxic polymer gel dosimeter investigated using proton beam absorbed dose measurements
    • Gustavsson, H., Bjack, S. A. J., Medin, J., Grusell, E., Olsson, L. E. Linear energy transfer dependence of a normoxic polymer gel dosimeter investigated using proton beam absorbed dose measurements. Phys Med Biol 49, 3847-3855 (2004).
    • (2004) Phys Med Biol , vol.49 , pp. 3847-3855
    • Gustavsson, H.1    Bjack, S.A.J.2    Medin, J.3    Grusell, E.4    Olsson, L.E.5
  • 11
    • 0038715468 scopus 로고    scopus 로고
    • Use of BANG(R) polymer gel for dose measurements in a 68 MeV proton beam
    • Heufelder, J., Stiefel, S., Pfaender, M., Ludemann, L., Grebe, G., Heese, J. Use of BANG(R) polymer gel for dose measurements in a 68 MeV proton beam. Med Phys 30, 1235-1240 (2003).
    • (2003) Med Phys , vol.30 , pp. 1235-1240
    • Heufelder, J.1    Stiefel, S.2    Pfaender, M.3    Ludemann, L.4    Grebe, G.5    Heese, J.6
  • 12
    • 42449118498 scopus 로고    scopus 로고
    • Characterizing the response of miniature scintillation detectors when irradiated with proton beams
    • Archambault, L., Polf, J. C., Beaulieu, L., Beddar, S. Characterizing the response of miniature scintillation detectors when irradiated with proton beams. Phys Med Biol 53, 1865-1876 (2008).
    • (2008) Phys Med Biol , vol.53 , pp. 1865-1876
    • Archambault, L.1    Polf, J.C.2    Beaulieu, L.3    Beddar, S.4
  • 13
    • 0031148917 scopus 로고    scopus 로고
    • Radiochromic film dosimetry for clinical proton beams
    • Vatnitsky, S. M. Radiochromic film dosimetry for clinical proton beams. Appl Rad Isotopes 48, 643-651 (1997).
    • (1997) Appl Rad Isotopes , vol.48 , pp. 643-651
    • Vatnitsky, S.M.1
  • 16
    • 0037573249 scopus 로고    scopus 로고
    • Analytical linear energy transfer calculations for proton therapy
    • Wilkens, J. J., Oelfke, U. Analytical linear energy transfer calculations for proton therapy. Med Phys 30, 806-815 (2003).
    • (2003) Med Phys , vol.30 , pp. 806-815
    • Wilkens, J.J.1    Oelfke, U.2
  • 17
    • 0031467140 scopus 로고    scopus 로고
    • An analytical approximation of the bragg curve for therapeutic proton beams
    • Bortfeld, T. An analytical approximation of the bragg curve for therapeutic proton beams. Med Phys 24, 2024-2033 (1997).
    • (1997) Med Phys , vol.24 , pp. 2024-2033
    • Bortfeld, T.1
  • 18
    • 0033023694 scopus 로고    scopus 로고
    • Range modulation in proton therapy-an optimization technique for clinical and experimental applications
    • Gardey, K.-U., Oelfke, U., Lam, G. K. Y. Range modulation in proton therapy-an optimization technique for clinical and experimental applications. Phys Med Biol 44, N81-N88 (1999).
    • (1999) Phys Med Biol , vol.44
    • Gardey, K.-U.1    Oelfke, U.2    Lam, G.K.Y.3
  • 19
    • 0029801087 scopus 로고    scopus 로고
    • Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: II. Optical properties of the BANG polymer gel
    • Maryanski, M. J., Zastavker, Y. Z., Gore, J. C. Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: II. Optical properties of the BANG polymer gel. Phys Med Biol 41, 2705-2717 (1996).
    • (1996) Phys Med Biol , vol.41 , pp. 2705-2717
    • Maryanski, M.J.1    Zastavker, Y.Z.2    Gore, J.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.