Volumn 107, Issue 2, 2012, Pages 74-86

Development of a fully automated open-column chemicalseparation system-COLUMNSPIDER-and its application to Sr-Nd-Pb isotope analyses of igneous rock samples

Author keywords

Chemical separation; Fully automated; Open column; Pipetting robot; Sr Nd Pb isotope

Indexed keywords


EID: 84865815673     PISSN: 13456296     EISSN: 13493825     Source Type: Journal    
DOI: 10.2465/jmps.110520     Document Type: Article
Times cited : (22)

References (57)
  • 1
    • 11544273695 scopus 로고
    • The use of ion exchange columns in mineral analysis for age determination
    • Aldrich, L.T., Doak, J.B. and Davis, G.L. (1953) The use of ion exchange columns in mineral analysis for age determination. American Journal of Science, 251, 377-387.
    • (1953) American Journal of Science , vol.251 , pp. 377-387
    • Aldrich, L.T.1    Doak, J.B.2    Davis, G.L.3
  • 2
    • 78649449769 scopus 로고    scopus 로고
    • 144Nd isotopic ratios of Nd separated from geological standards by chromatographic methods
    • 144Nd isotopic ratios of Nd separated from geological standards by chromatographic methods. International Journal of Mass Spectrometry, 299, 27-34.
    • (2011) International Journal of Mass Spectrometry , vol.299 , pp. 27-34
    • Ali, A.1    Srinivasan, G.2
  • 3
    • 0027062209 scopus 로고
    • 144Nd ratios of twelve GSJ rock reference samples and reproducibility of the data
    • 144Nd ratios of twelve GSJ rock reference samples and reproducibility of the data. Geochemical Journal, 26, 105-109.
    • (1992) Geochemical Journal , vol.26 , pp. 105-109
    • Arakawa, Y.1
  • 4
    • 1442283665 scopus 로고    scopus 로고
    • 204Pb double spike and thallium to correct for mass bias with adouble-focusing MC-ICP-MS
    • 204Pb double spike and thallium to correct for mass bias with adouble-focusing MC-ICP-MS. Chemical Geology, 211, 275-303.
    • (2004) Chemical Geology , vol.211 , pp. 275-303
    • Baker, J.1    Peate, D.2    Waight, T.3    Meyzen, C.4
  • 6
    • 0022926178 scopus 로고
    • Precision K-Rb-Sr isotopic analysis: Application to Rb-Sr chronology
    • Birck, J.L. (1986) Precision K-Rb-Sr isotopic analysis: Application to Rb-Sr chronology. Chemical Geology, 56, 73-83.
    • (1986) Chemical Geology , vol.56 , pp. 73-83
    • Birck, J.L.1
  • 7
    • 72749086414 scopus 로고    scopus 로고
    • Hawaiian hot spot dynamics as inferred from the Hf and Pb isotope evolution of Mauna Kea volcanoGeochemistry, Geophysics, Geosystems,
    • doi: 10 1029/2002GC000340.
    • Blichert-Toft, J., Weis, D., Maerschalk, C., Agranier, A. and Albarède, F. (2003) Hawaiian hot spot dynamics as inferred from the Hf and Pb isotope evolution of Mauna Kea volcanoGeochemistry, Geophysics, Geosystems, 4(2), 8704, doi: 10.1029/2002GC000340.
    • (2003) , vol.4 , Issue.2 , pp. 8704
    • Blichert-Toft, J.1    Weis, D.2    Maerschalk, C.3    Agranier, A.4    Albarède, F.5
  • 8
    • 70350222073 scopus 로고    scopus 로고
    • Precise determination of Sm, Nd concentrations and Nd isotopic compositions at the nanogram level in geological samples bythermal ionization mass spectrometry
    • Chu, Z.-Y., Chen F.-K., Yang Y.-H. and Guo J.-H. (2009) Precise determination of Sm, Nd concentrations and Nd isotopic compositions at the nanogram level in geological samples bythermal ionization mass spectrometry. Journal of Analytical Atomic Spectrometry, 24, 1534-1544.
    • (2009) Journal of Analytical Atomic Spectrometry , vol.24 , pp. 1534-1544
    • Chu, Z.-Y.1    Chen, F.-K.2    Yang, Y.-H.3    Guo, J.-H.4
  • 10
    • 0030579075 scopus 로고    scopus 로고
    • A new method for extracting and purifying lead from difficult matrices for isotopic analysis
    • Gale, N.H. (1996) A new method for extracting and purifying lead from difficult matrices for isotopic analysis. Analytica Chimica Acta, 332, 15-21.
    • (1996) Analytica Chimica Acta , vol.332 , pp. 15-21
    • Gale, N.H.1
  • 15
    • 0028206172 scopus 로고
    • A lead-selective extraction chromatographic resin and its application to the isolation of lead from geological samples
    • Horwitz, E.P., Dietz, M.L., Rhoads, S., Felinto, C., Gale, N.H. and Houghton, J. (1994) A lead-selective extraction chromatographic resin and its application to the isolation of lead from geological samples. Analytica Chimica Acta, 292, 263-273.
    • (1994) Analytica Chimica Acta , vol.292 , pp. 263-273
    • Horwitz, E.P.1    Dietz, M.L.2    Rhoads, S.3    Felinto, C.4    Gale, N.H.5    Houghton, J.6
  • 18
    • 0038006015 scopus 로고    scopus 로고
    • Fluid-mantle interaction in an intra-oceanic arc: constraints from high-precision Pb isotopes
    • Ishizuka, O., Taylor, R.N., Milton, J.A. and Nesbitt, R.W. (2003) Fluid-mantle interaction in an intra-oceanic arc: constraints from high-precision Pb isotopes, Earth and Planetary Science Letters, 211, 221-236.
    • (2003) Earth and Planetary Science Letters , vol.211 , pp. 221-23
    • Ishizuka, O.1    Taylor, R.N.2    Milton, J.A.3    Nesbitt, R.W.4
  • 20
    • 33644629828 scopus 로고    scopus 로고
    • precise lead isotope analysis using Multiple Colector-Inductively Coupled Plasma-Mass Spectrometry (MC-ICP-MS): Analytical technique and evaluation of mass fractionation during Pbseparation
    • Kimura, J.-I. and Nakano, N. (2004) Precise lead isotope analysis using Multiple Colector-Inductively Coupled Plasma-Mass Spectrometry (MC-ICP-MS): Analytical technique and evaluation of mass fractionation during Pb separation. Geoscience Report of Shimane University, 23, 9-15.
    • (2004) Geoscience Report of Shimane University , vol.23 , pp. 9-15
    • Kimura, J.-I.1    Nakano, N.2
  • 21
    • 84865816325 scopus 로고
    • Lead isotope analyses of standard rock samples
    • E.2002 Precise isotope analysis of nanogram-level Pb for natural rock samples without use of double spikes. Chemical Geology
    • Koide, Y. and Nakamura, E. (1990) Lead isotope analyses of standard rock samples. Mass Spectroscopy, 38, 241-252. Kuritani, T and Nakamura, E. (2002) Precise isotope analysis of nanogram-level Pb for natural rock samples without use of double spikes. Chemical Geology, 186, 31-43
    • (1990) Mass Spectroscopy, 38, 241-252. Kuritani, T and Nakamura, , vol.186 , pp. 31-43
    • Koide, Y.1    Nakamura, E.2
  • 22
    • 20444421511 scopus 로고    scopus 로고
    • Astraightforward separation scheme for concomitant Lu-Hf and Sm-Nd isotope ratio and isotope dilution analysis
    • Le Fèvre, B. and Pin, C. (2005) A straightforward separation scheme for concomitant Lu-Hf and Sm-Nd isotope ratio and isotope dilution analysis. Analytica Chimica Acta, 543, 209-221.
    • (2005) Analytica Chimica Acta , vol.543 , pp. 209-221
    • Le Fèvre, B.1    Pin, C.2
  • 23
    • 34548442963 scopus 로고    scopus 로고
    • Precise isotopic measurements of sub-nanogram Nd of standard reference material by thermal ionization mass spectrometry using the NdO+ technique
    • Li, C.-F., Chen, F. and Li, X.-H. (2007) Precise isotopic measurements of sub-nanogram Nd of standard reference material by thermal ionization mass spectrometry using the NdO+ technique. International Journal of Mass Spectrometry, 266, 34-41.
    • (2007) International Journal of Mass Spectrometry , vol.266 , pp. 34-41
    • Li, C.-F.1    Chen, F.2    Li, X.-H.3
  • 24
    • 84862929680 scopus 로고    scopus 로고
    • Directly determining 143Nd/144Nd isotope ratios using thermal ionization mass spectrometry for geological samples without separation of Sm-Nd
    • doi: 10.1039/C0JA00081G
    • Li, C.-F., Li, X.-H, Li, Q.-L., Guo, J.-H. and Li, X.-H. (2011) Directly determining 143Nd/144Nd isotope ratios using thermal ionization mass spectrometry for geological samples without separation of Sm-Nd. Journal of Analytical Atomic Spectrometry, doi: 10.1039/C0JA00081G.
    • (2011) Journal of Analytical Atomic Spectrometry
    • Li, C.-F.1    Li X.-H Li, Q.-L.2    Guo, J.-H.3    Li, X.-H.4
  • 25
    • 0026273098 scopus 로고
    • Precise measurement of cerium isotope composition in rock samples
    • Makishima, A. and Nakamura, E. (1991) Precise measurement of cerium isotope composition in rock samples. Chemical Geology, 94, 1-11.
    • (1991) Chemical Geology , vol.94 , pp. 1-11
    • Makishima, A.1    Nakamura, E.2
  • 26
    • 34047168736 scopus 로고    scopus 로고
    • Precise determination of Pb isotope ratios by simple double spike MCICP-MS technique without Tl addition
    • Makishima, A., Nath, B.N. and Nakamura, E. (2007) Precise determination of Pb isotope ratios by simple double spike MCICP-MS technique without Tl addition. Journal of Analytical Atomic Spectrometry, 22, 407-410.
    • (2007) Journal of Analytical Atomic Spectrometry , vol.22 , pp. 407-410
    • Makishima, A.1    Nath, B.N.2    Nakamura, E.3
  • 27
    • 55349133094 scopus 로고    scopus 로고
    • New sequential separation procedure for Sr, Nd and Pb isotope ratio measurement in geological material using MC-ICP-MS and TIMS
    • Makishima, A., Nath, B.N. and Nakamura, E. (2008) New sequential separation procedure for Sr, Nd and Pb isotope ratio measurement in geological material using MC-ICP-MS and TIMS. Geochemical Journal, 42, 237-246.
    • (2008) Geochemical Journal , vol.42 , pp. 237-246
    • Makishima, A.1    Nath, B.N.2    Nakamura, E.3
  • 28
    • 49349125445 scopus 로고
    • Comparative uranium-thorium-lead and rubidium-strontium study of the Saint Severin amphoterite: consequences for early solar system chronology
    • Manhes, G., Minster, J.F. and Allègre, C.J. (1978) Comparative uranium-thorium-lead and rubidium-strontium study of the Saint Severin amphoterite: consequences for early solar system chronology. Earth and Planetary Science Letters, 39, 14-24.
    • (1978) Earth and Planetary Science Letters , vol.39 , pp. 14-24
    • Manhes, G.1    Minster, J.F.2    Allègre, C.J.3
  • 29
    • 33344477163 scopus 로고    scopus 로고
    • Automated separation of Sr from natural water samples or carbonate rocks by high performance ion chromatography
    • Meynadier, L., Gorge, C., Birck, J.-L. and Allègre, C.J. (2006) Automated separation of Sr from natural water samples or carbonate rocks by high performance ion chromatography. Chemical Geology, 227, 26-36.
    • (2006) Chemical Geology , vol.227 , pp. 26-36
    • Meynadier, L.1    Gorge, C.2    Birck, J.-L.3    Allègre, C.J.4
  • 30
    • 42049096122 scopus 로고    scopus 로고
    • Modified chromatographic separation scheme for Sr and Nd isotope analysis in geological silicate samples
    • Míková, J. and Denková, P. (2007) Modified chromatographic separation scheme for Sr and Nd isotope analysis in geological silicate samples. Journal of Geosciences, 52, 221-226.
    • (2007) Journal of Geosciences , vol.52 , pp. 221-226
    • Míková, J.1    Denková, P.2
  • 31
    • 0034023081 scopus 로고    scopus 로고
    • Separaiton of rare earth elements and strontium from chondritic meteorites by miniaturized extraction chromatography for elemental and isotopic analyses
    • Misawa, K., Yamazaki, F., Ihira, N. and Nakamura, N. (2000) Separaiton of rare earth elements and strontium from chondritic meteorites by miniaturized extraction chromatography for elemental and isotopic analyses. Geochemical Journal, 34, 11-21.
    • (2000) Geochemical Journal , vol.34 , pp. 11-21
    • Misawa, K.1    Yamazaki, F.2    Ihira, N.3    Nakamura, N.4
  • 32
    • 0005358939 scopus 로고    scopus 로고
    • Sr and Nd isotope ratios of twelve GSJ rock reference samples
    • Miyazaki, T. and Shuto, K. (1998) Sr and Nd isotope ratios of twelve GSJ rock reference samples. Geochemical Journal, 32, 345-350.
    • (1998) Geochemical Journal , vol.32 , pp. 345-350
    • Miyazaki, T.1    Shuto, K.2
  • 34
    • 0028794412 scopus 로고
    • A systematic and practical method of liquid chromatography for the determination of Sr and Nd isotopic ratios and REE concentrations in geological samples
    • Na, C.-K., Nakano, T., Tazawa, K., Sakagawa, M. and Ito, T. (1995). A systematic and practical method of liquid chromatography for the determination of Sr and Nd isotopic ratios and REE concentrations in geological samples. Chemical Geology, 123, 225-237.
    • (1995) Chemical Geology , vol.123 , pp. 225-237
    • Na, C.-K.1    Nakano, T.2    Tazawa, K.3    Sakagawa, M.4    Ito, T.5
  • 35
    • 46149102434 scopus 로고    scopus 로고
    • Simultaneous determination of mass-dependent isotopic fractionation and radiogenic isotope variation of Strontium in geochemical samples by Multiple Collector-ICP-Mass Spectrometry
    • Ohno, T. and Hirata, T. (2007) Simultaneous determination of mass-dependent isotopic fractionation and radiogenic isotope variation of Strontium in geochemical samples by Multiple Collector-ICP-Mass Spectrometry. Analytical Sciences, 23, 1275-1280.
    • (2007) Analytical Sciences , vol.23 , pp. 1275-1280
    • Ohno, T.1    Hirata, T.2
  • 36
    • 0031712694 scopus 로고    scopus 로고
    • Sr and Nd isotopic data for the seven GSJ rock reference samples; JA-1, JB-1a, JB-2, JB-3, JG-1a, JGb-1 and JR-1.
    • Orihashi, Y., Maeda, J., Tanaka, R., Zeniya, R. and Niida, K. (1998) Sr and Nd isotopic data for the seven GSJ rock reference samples; JA-1, JB-1a, JB-2, JB-3, JG-1a, JGb-1 and JR-1. Geochemical Journal, 32, 205-211.
    • (1998) Geochemical Journal , vol.32 , pp. 205-211
    • Orihashi, Y.1    Maeda, J.2    Tanaka, R.3    Zeniya, R.4    Niida, K.5
  • 37
    • 0026458515 scopus 로고
    • valuation of a strontium-specific extraction chromatographic method for isotopic analysis in geological materials
    • Pin, C. and Bassin, C. (1992) Evaluation of a strontium-specific extraction chromatographic method for isotopic analysis in geological materials. Analytica Chimica Acta, 269, 249-255.
    • (1992) Analytica Chimica Acta , vol.269 , pp. 249-255
    • Pin, C.1    Bassin, C.2
  • 38
    • 0028127258 scopus 로고
    • Concomitant separation of strontium and samarium-neodymium for isotopic analysis in silicate samples, based on specific extraction chromatography
    • Pin, C., Briot, D., Bassin, C. and Poitrasson, F. (1994) Concomitant separation of strontium and samarium-neodymium for isotopic analysis in silicate samples, based on specific extraction chromatography. Analytica Chimica Acta, 298, 209-217.
    • (1994) Analytica Chimica Acta , vol.298 , pp. 209-217
    • Pin, C.1    Briot, D.2    Bassin, C.3    Poitrasson, F.4
  • 39
    • 0031588777 scopus 로고    scopus 로고
    • equential separation of light rare-earth elements, thorium and uranium by miniaturized extraction chromatography: Application to isotopic analyses of silicate rocks
    • Pin, C. and Zalduegui, J.-F.S. (1997) Sequential separation of light rare-earth elements, thorium and uranium by miniaturized extraction chromatography: Application to isotopic analyses of silicate rocks. Analytica Chimica Acta, 339, 79-89.
    • (1997) Analytica Chimica Acta , vol.339 , pp. 79-89
    • Pin, C.1    Zalduegui, J.-F.S.2
  • 40
    • 4344639619 scopus 로고    scopus 로고
    • eodymium and Strontium Isotope Data for USGS Reference Materials BCR-1, BCR-2, BHVO-1, BHVO-2, AGV-1, AGV-2, GSP-1, GSP-2 and Eight MPI-DING Reference Glasses
    • Raczek, I., Peter Jochum, K. and Hofmann, A.W. (2003) Neodymium and Strontium Isotope Data for USGS Reference Materials BCR-1, BCR-2, BHVO-1, BHVO-2, AGV-1, AGV-2, GSP-1, GSP-2 and Eight MPI-DING Reference Glasses. Geostandards Newsletter: The Journal of Geostandards and Geoanalysis, 27, 173-179.
    • (2003) Geostandards Newsletter: The Journal of Geostandards and Geoanalysis , vol.27 , pp. 173-179
    • Raczek, I.1    Peter Jochum, K.2    Hofmann, A.W.3
  • 42
    • 73749085296 scopus 로고    scopus 로고
    • Breaking the glass ceiling for high resolution Nd isotope records in early Cenozoic paleoceanography
    • Scher, H.D. and Delaney, M.L. (2010) Breaking the glass ceiling for high resolution Nd isotope records in early Cenozoic paleoceanography. Chemical Geology, 269, 329-338.
    • (2010) Chemical Geology , vol.269 , pp. 329-338
    • Scher, H.D.1    Delaney, M.L.2
  • 43
    • 14744298896 scopus 로고    scopus 로고
    • An analytical method for determining precise Sr and Nd isotopic compositions and result for thirteen rock standard materials
    • Shibata, T., Yoshikawa, M. and Tatsumi, Y. (2003) An analytical method for determining precise Sr and Nd isotopic compositions and result for thirteen rock standard materials. Frontier Research on Earth Evolution, 1, 363-367.
    • (2003) Frontier Research on Earth Evolution , vol.1 , pp. 363-367
    • Shibata, T.1    Yoshikawa, M.2    Tatsumi, Y.3
  • 44
    • 33751082744 scopus 로고    scopus 로고
    • Precise isotope determination of trace amounts of Nd in Magnesium-rich samples
    • Shibata, T. and Yoshikawa, M. (2004) Precise isotope determination of trace amounts of Nd in Magnesium-rich samples. Journal of the Mass Spectrometry Society of Japan, 52, 317-324.
    • (2004) Journal of the Mass Spectrometry Society of Japan , vol.52 , pp. 317-324
    • Shibata, T.1    Yoshikawa, M.2
  • 46
    • 0027068832 scopus 로고
    • Improved HPLC method for the separation of Rb and Sr in connection with Rb-Sr dating
    • Stray, H. (1992) Improved HPLC method for the separation of Rb and Sr in connection with Rb-Sr dating. Chemical Geology, 102, 129-135.
    • (1992) Chemical Geology , vol.102 , pp. 129-135
    • Stray, H.1
  • 49
    • 33645143514 scopus 로고    scopus 로고
    • Development of rapid and precise Pb isotope analytical techniques using MC-ICP-MS and new results for GSJ rock reference samples
    • Tanimizu, M. and Ishikawa, T. (2006) Development of rapid and precise Pb isotope analytical techniques using MC-ICP-MS and new results for GSJ rock reference samples. Geochemcal Journal, 40, 121-133.
    • (2006) Geochemcal Journal , vol.40 , pp. 121-133
    • Tanimizu, M.1    Ishikawa, T.2
  • 50
    • 0024485189 scopus 로고
    • Os, Sr, Nd, and Pb isotope systematics of southern African peridotite xenoliths: Implications for the chemical evolution of subcontinental mantle
    • Walker, R.J., Carlson, R.W., Shirey, S.B. and Boyd, F.R. (1989) Os, Sr, Nd, and Pb isotope systematics of southern African peridotite xenoliths: Implications for the chemical evolution of subcontinental mantle. Geochimica et Cosmochimica Acta, 53, 1583-1595.
    • (1989) Geochimica et Cosmochimica Acta , vol.53 , pp. 1583-1595
    • Walker, R.J.1    Carlson, R.W.2    Shirey, S.B.3    Boyd, F.R.4
  • 54
    • 75749148277 scopus 로고    scopus 로고
    • Combined chemical separation of Lu, Hf, Rb, Sr, Sm and Nd from a single rock digest and precise and accurate isotope determinations of Lu-Hf, Rb-Sr and Sm-Nd isotope systems using Multi-Collector ICP-MS and TIMS
    • Yang, Y.-H., Zhang, H.-F., Chu, Z.-Y., Xie, L.-W. and Wu, F.-Y. (2010a) Combined chemical separation of Lu, Hf, Rb, Sr, Sm and Nd from a single rock digest and precise and accurate isotope determinations of Lu-Hf, Rb-Sr and Sm-Nd isotope systems using Multi-Collector ICP-MS and TIMS. International Journal of Mass Spectrometry, 290, 120-126.
    • (2010) International Journal of Mass Spectrometry , vol.290 , pp. 120-126
    • Yang, Y.-H.1    Zhang, H.-F.2    Chu, Z.-Y.3    Xie, L.-W.4    Wu, F.-Y.5
  • 55
    • 74349101492 scopus 로고    scopus 로고
    • High-Precision Measurements of the 143Nd/144Nd Isotope Ratio in Certified Reference Materials without Nd and Sm Separation by Multiple Collector Inductively Coupled Plasma Mass Spectrometry
    • Yang, Y.-H., Wu, F.-Y., Xie, L.-W. and Zhang, Y.-B. (2010b) High-Precision Measurements of the 143Nd/144Nd Isotope Ratio in Certified Reference Materials without Nd and Sm Separation by Multiple Collector Inductively Coupled Plasma Mass Spectrometry. Analytical Letters, 43, 142-150.
    • (2010) Analytical Letters , vol.43 , pp. 142-150
    • Yang, Y.-H.1    Wu, F.-Y.2    Xie, L.-W.3    Zhang, Y.-B.4
  • 56
    • 79960719183 scopus 로고    scopus 로고
    • Precise and accurate determination of Sm, Nd concentrations and Nd isotopic compositions in geological samples by MC-ICP-MS
    • Yang, Y.-H., Chu, Z.-Y., Wu, F.-Y., Xie, L.-W. and Yang, J.-H. (2011) Precise and accurate determination of Sm, Nd concentrations and Nd isotopic compositions in geological samples by MC-ICP-MS. Journal of Analytical Atomic Spectrometry, 26, 1237-1244.
    • (2011) Journal of Analytical Atomic Spectrometry , vol.26 , pp. 1237-1244
    • Yang, Y.-H.1    Chu, Z.-Y.2    Wu, F.-Y.3    Xie, L.-W.4    Yang, J.-H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.