메뉴 건너뛰기




Volumn 8, Issue 2, 2012, Pages 267-274

Longitudinal stent deformation: A retrospective analysis of frequency and mechanisms

Author keywords

Coronary stents; Longitudinal stent deformation; Percutaneous coronary intervention; Procedural complications

Indexed keywords

ACUTE CORONARY SYNDROME; ADULT; AGED; ARTICLE; BALLOON DILATATION; CATHETERIZATION; CLINICAL ARTICLE; CLINICAL FEATURE; CONTROLLED STUDY; DEVICE SAFETY; DISEASE ASSOCIATION; DRUG ELUTING STENT; EQUIPMENT DESIGN; FEMALE; FOLLOW UP; GUIDE WIRE; HUMAN; IATROGENIC DISEASE; INTERMETHOD COMPARISON; MALE; OUTCOME ASSESSMENT; POSTOPERATIVE COMPLICATION; RETROSPECTIVE STUDY; ST SEGMENT ELEVATION MYOCARDIAL INFARCTION; STENT THROMBOSIS; SURGICAL APPROACH;

EID: 84865612477     PISSN: 1774024X     EISSN: 19696213     Source Type: Journal    
DOI: 10.4244/EIJV8I2A41     Document Type: Article
Times cited : (107)

References (6)
  • 3
    • 79954480864 scopus 로고    scopus 로고
    • Periprocedural (30-day) risk of myocardial infarction after drug-eluting coronary stent implantation: A meta-analysis comparing cobalt-chromium and stainless steel drug-eluting coronary stents
    • Moreno R, Jimenez-Valero S, Sanchez-Recalde A, Galeote G, Calvo L, Martin-Reyes R, Sabate M, Plaza I, Macaya C, Lopez- Sendon JL. Periprocedural (30-day) risk of myocardial infarction after drug-eluting coronary stent implantation: a meta-analysis comparing cobalt-chromium and stainless steel drug-eluting coronary stents. EuroIntervention. 2011;6:1003-10.
    • (2011) EuroIntervention , vol.6 , pp. 1003-1010
    • Moreno, R.1    Jimenez-Valero, S.2    Sanchez-Recalde, A.3    Galeote, G.4    Calvo, L.5    Martin-Reyes, R.6    Sabate, M.7    Plaza, I.8    Macaya, C.9    Lopez-Sendon, J.L.10
  • 4
    • 80155191186 scopus 로고    scopus 로고
    • Longitudinal compression: A "new" complication with modern coronary stent platfroms - Time to think beyond deliverability?
    • Hanratty CG, Walsh SJ. Longitudinal compression: a "new" complication with modern coronary stent platfroms - time to think beyond deliverability? EuroIntervention 2011;7:872-877.
    • (2011) EuroIntervention , vol.7 , pp. 872-877
    • Hanratty, C.G.1    Walsh, S.J.2
  • 5
    • 80155191184 scopus 로고    scopus 로고
    • Stent design back in the picture: An engineering perspective on longitudinal stent compression
    • Mortier P, De Beule M. Stent design back in the picture: an engineering perspective on longitudinal stent compression. EuroIntervention. 2011;7:773-776.
    • (2011) EuroIntervention , vol.7 , pp. 773-776
    • Mortier, P.1    De Beule, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.