Volumn 6, Issue 8, 2011, Pages 1003-1010

Periprocedural (30-day) risk of myocardial infarction after drug-eluting coronary stent implantation: A meta-analysis comparing cobalt-chromium and stainless steel drug-eluting coronary stents

Author keywords

Acute myocardial infarction; Coronary stent; Drug eluting stent; Meta analysis

Indexed keywords

CHROMIUM; COBALT; EVEROLIMUS; PACLITAXEL; RAPAMYCIN; STAINLESS STEEL; ZOTAROLIMUS;

EID: 79954480864     PISSN: 1774024X     EISSN: 19696213     Source Type: Journal    
DOI: 10.4244/EIJV6I8A173     Document Type: Review
Times cited : (11)

References (28)
  • 5
    • 79954500608 scopus 로고    scopus 로고
    • SPIRIT-IV: A prospective randomized trial of everolimuseluting vs. paclitaxel-eluting stents
    • Presented Available accessed on 6th November, 2009
    • Stone GW. SPIRIT-IV: a prospective randomized trial of everolimuseluting vs. paclitaxel-eluting stents. Presented in: Transcatheter and Therapeutics intervention 2009. Available in: http://www.tctmd.com/show.aspx?id=84104 (accessed on 6th November, 2009).
    • Transcatheter and Therapeutics Intervention 2009
    • Stone, G.W.1
  • 6
    • 73949122498 scopus 로고    scopus 로고
    • Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice (COMPARE): A randomised trial
    • Kedhi E, Joesoef KS, McFadden E, Wassing J, van Mieghem C, Goedhart D, SmitsPC. Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice (COMPARE): a randomised trial. Lancet 2010;375:201-09.
    • (2010) Lancet , vol.375 , pp. 201-209
    • Kedhi, E.1    Joesoef, K.S.2    McFadden, E.3    Wassing, J.4    Van Mieghem, C.5    Goedhart, D.6    Smits, P.C.7
  • 11
    • 79954459736 scopus 로고    scopus 로고
    • ZOMAXX II - A Randomized, Controlled Trial to Evaluate the ZoMaxx Compared to the TAXUS Express2 stent systems in de novo Coronary Artery Lesions
    • Presented at the Available accessed on 6th November, 2009
    • Gray WA. ZOMAXX II - A Randomized, Controlled Trial to Evaluate the ZoMaxx Compared to the TAXUS Express2 stent systems in de novo Coronary Artery Lesions. Presented at the EuroPCR 2008. Available in: http://www.tctmd.com/show. aspx?id=67822 (accessed on 6th November, 2009).
    • EuroPCR 2008
    • Gray, W.A.1
  • 12
    • 79954456723 scopus 로고    scopus 로고
    • Comparison of the Efficacy and Safety of Zotarolimus- Eluting Stent versus Sirolimus-Eluting Stent and PacliTaxel-Eluting Stent for Coronary Lesions: The ZEST Trial
    • Presented at the Available accessed on 6th November, 2009
    • Park SJ. Comparison of the Efficacy and Safety of Zotarolimus- Eluting Stent versus Sirolimus-Eluting Stent and PacliTaxel-Eluting Stent for Coronary Lesions: The ZEST Trial. Presented at the American College of Cardiology Session 2008. Available in: http://www.tctmd.com/show.aspx?id=77306 (accessed on 6th November, 2009).
    • American College of Cardiology Session 2008
    • Park, S.J.1
  • 13
    • 65249138756 scopus 로고    scopus 로고
    • A polymer-free dual drug-eluting stent in patients with coronary artery disease: A randomized trial vs. polymer-based drugeluting stents
    • Byrne RA, Mehilli J, Lijima R, Schulz S, Pache J, Seyfarth M, Schömig A, Kastrati A. A polymer-free dual drug-eluting stent in patients with coronary artery disease: a randomized trial vs. polymer-based drugeluting stents. Eur Heart J 2009;30:923-31.
    • (2009) Eur Heart J , vol.30 , pp. 923-931
    • Byrne, R.A.1    Mehilli, J.2    Lijima, R.3    Schulz, S.4    Pache, J.5    Seyfarth, M.6    Schömig, A.7    Kastrati, A.8
  • 15
    • 79954510068 scopus 로고    scopus 로고
    • 6-months results of the NEVO RES-ELUTION-I (RES-I) trial
    • th November, 2009
    • th November, 2009).
    • EuroPCR 2009
    • Spaulding, C.1
  • 17
    • 0033610734 scopus 로고    scopus 로고
    • Improving the quality of reports of meta-analysis of randomised controlled trials: The QUOROM statement
    • Moher D, Cook DJ, Eastwood S, Olkin I, Rennie D, Stroup DF, Improving the quality of reports of meta-analysis of randomised controlled trials: the QUOROM statement. Lancet 1999;354:1896-1900.
    • (1999) Lancet , vol.354 , pp. 1896-1900
    • Moher, D.1    Cook, D.J.2    Eastwood, S.3    Olkin, I.4    Rennie, D.5    Stroup, D.F.6
  • 21
    • 33646699603 scopus 로고    scopus 로고
    • Angiographic Adverse Events, Creatine Kinase-MB Elevation, and Ischemic End Points Complicating Percutaneous Coronary Intervention (a REPLACE-2 Substudy)
    • DOI 10.1016/j.amjcard.2005.12.050, PII S0002914906003687
    • Blankenship JC, Haldis T, Feit F, Hu T, Kleiman NS, Topol EJ, Lincoff AM; REPLACE-2 Investigators. Angiographic adverse events, creatine kinase-MB elevation, and ischemic end points complicating percutaneous coronary intervention (a REPLACE-2 substudy). Am J Cardiol 2006;97:1591-6. (Pubitemid 43737026)
    • (2006) American Journal of Cardiology , vol.97 , Issue.11 , pp. 1591-1596
    • Blankenship, J.C.1    Haldis, T.2    Feit, F.3    Hu, T.4    Kleiman, N.S.5    Topol, E.J.6    Lincoff, A.M.7
  • 22
    • 33847011333 scopus 로고    scopus 로고
    • Predictors of periprocedural creatine kinase-myocardial band elevation complicating elective percutaneous coronary intervention
    • Cai Q, Skelding KA, Armstrong AT Jr, Desai D, Wood GC, Blankenship JC. Predictors of periprocedural creatine kinase-myocardial band elevation complicating elective percutaneous coronary intervention. Am J Cardiol 2007;99:616-20.
    • (2007) Am J Cardiol , vol.99 , pp. 616-620
    • Cai, Q.1    Skelding, K.A.2    Armstrong Jr., A.T.3    Desai, D.4    Wood, G.C.5    Blankenship, J.C.6
  • 25
    • 62649157735 scopus 로고    scopus 로고
    • Determination of the influence of stent strut thickness using the finite element method: Implications for vascular injury and in-stent restenosis
    • Zahedmanesh H, Lally C. Determination of the influence of stent strut thickness using the finite element method: implications for vascular injury and in-stent restenosis. Med Biol Eng Comput 2009;47:385-93.
    • (2009) Med Biol Eng Comput , vol.47 , pp. 385-393
    • Zahedmanesh, H.1    Lally, C.2
  • 26
    • 3042567527 scopus 로고    scopus 로고
    • Stent design properties and deployment ratio influence indexes of wall shear stress: A three-dimensional computational fluid dynamics investigation within a normal artery
    • DOI 10.1152/japplphysiol.01329.2003
    • LaDisa JF Jr, Olson LE, Guler I, Hettrick DA, Audi SH, Kersten JR, Warltier DC, Pagel PS. Stent design properties and deployment ratio influence indexes of wall shear stress: a three-dimensional computational fluid dynamics investigation within a normal artery. J Appl Physiol 2004;97:424-30. (Pubitemid 38802547)
    • (2004) Journal of Applied Physiology , vol.97 , Issue.1 , pp. 424-430
    • LaDisa Jr., J.F.1    Olson, L.E.2    Guler, I.3    Hettrick, D.A.4    Audi, S.H.5    Kersten, J.R.6    Warltier, D.C.7    Pagel, P.S.8
  • 27
    • 0038610567 scopus 로고    scopus 로고
    • The stress-strain behavior of coronary stent struts is size dependent
    • Murphy BP, Savage P, McHugh PE, Quinn DF. The stress-strain behavior of coronary stent struts is size dependent. Ann Biomed Eng 2003;31:686-91.
    • (2003) Ann Biomed Eng , vol.31 , pp. 686-691
    • Murphy, B.P.1    Savage, P.2    McHugh, P.E.3    Quinn, D.F.4
  • 28
    • 64849091370 scopus 로고    scopus 로고
    • The influence of strut thickness and cell design on immediate apposition of drug-eluting stents assessed by optical coherence tomography
    • Tanigawa J, Barlis P, Dimopoulos K, Dalby M, Moore P, Di Mario C. The influence of strut thickness and cell design on immediate apposition of drug-eluting stents assessed by optical coherence tomography. Int J Cardiol 2009;134:180-8.
    • (2009) Int J Cardiol , vol.134 , pp. 180-188
    • Tanigawa, J.1    Barlis, P.2    Dimopoulos, K.3    Dalby, M.4    Moore, P.5    Di Mario, C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.