메뉴 건너뛰기




Volumn 33, Issue 7, 2012, Pages 1176-1180

Finite element analysis of damage by cochlear implant electrode array's proximal section to the basilar membrane

Author keywords

Basilar membrane; Damage; Electrode array; Insertion; Scala tympani

Indexed keywords

ARTICLE; BASILAR MEMBRANE; COCHLEA; COCHLEA PROSTHESIS; ELECTRODE IMPLANT; FINITE ELEMENT ANALYSIS; HUMAN; INJURY; THEORETICAL MODEL;

EID: 84865599245     PISSN: 15317129     EISSN: 15374505     Source Type: Journal    
DOI: 10.1097/MAO.0b013e318263545f     Document Type: Article
Times cited : (13)

References (13)
  • 2
    • 0035126110 scopus 로고    scopus 로고
    • The Contour electrode array: Safety study and initial patient trials of a new perimodiolar design
    • Tykocinski M, Saunders E, Cohen LT, et al. The Contour electrode array: safety study and initial patient trials of a new perimodiolar design. Otol Neurotol 2001;22:33-41.
    • (2001) Otol Neurotol , vol.22 , pp. 33-41
    • Tykocinski, M.1    Saunders, E.2    Cohen, L.T.3
  • 3
    • 18044377967 scopus 로고    scopus 로고
    • A temporal bone study of insertion trauma and intracochlear position of cochlear implant electrodes. I: Comparison of Nucleus banded and Nucleus ContourTM electrodes
    • Wardrop P, Whinney D, Rebscher SJ, et al. A temporal bone study of insertion trauma and intracochlear position of cochlear implant electrodes. I: comparison of Nucleus banded and Nucleus ContourTM electrodes. Hear Res 2005;203:54-67.
    • (2005) Hear Res , vol.203 , pp. 54-67
    • Wardrop, P.1    Whinney, D.2    Rebscher, S.J.3
  • 4
    • 0022002625 scopus 로고
    • Banded intracochlear electrode array: Evaluation of insertion trauma in human temporal bones
    • Shepherd RK, Clark GM, Pyman BC et al. Banded intracochlear electrode array: evaluation of insertion trauma in human temporal bones. Ann Otol Rhinol Laryngol 1985;94:55-9.
    • (1985) Ann Otol Rhinol Laryngol , vol.94 , pp. 55-59
    • Shepherd, R.K.1    Clark, G.M.2    Pyman, B.C.3
  • 5
    • 0020264425 scopus 로고
    • Otopathological findings in a patient with bilateral cochlear implants
    • Johnsson LG, House WF, Linthicum FH. Otopathological findings in a patient with bilateral cochlear implants. Ann Otol Rhinol Laryngol 1982;91:74-89.
    • (1982) Ann Otol Rhinol Laryngol , vol.91 , pp. 74-89
    • Johnsson, L.G.1    House, W.F.2    Linthicum, F.H.3
  • 6
    • 0021674736 scopus 로고
    • Initial observations of a human temporal bone with a multi-channel implant
    • Galey FR. Initial observations of a human temporal bone with a multi-channel implant. Acta Otolaryngol 1984;411:38-44.
    • (1984) Acta Otolaryngol , vol.411 , pp. 38-44
    • Galey, F.R.1
  • 7
    • 0032751589 scopus 로고    scopus 로고
    • Growth factor therapy to the damaged inner ear: Clinical prospects
    • Malgrange B, Rigo JM, Thomas R, et al. Growth factor therapy to the damaged inner ear: clinical prospects. Int J Pediatr Otorhinolaryngol 1999;49:19-25.
    • (1999) Int J Pediatr Otorhinolaryngol , vol.49 , pp. 19-25
    • Malgrange, B.1    Rigo, J.M.2    Thomas, R.3
  • 8
    • 0347926364 scopus 로고    scopus 로고
    • Evaluation of trajectories and contact pressures for the straight nucleus cochlear implant electrode arrayVa two-dimensional application of finite element analysis
    • Chen BK, Clark GM, Jones R. Evaluation of trajectories and contact pressures for the straight nucleus cochlear implant electrode arrayVa two-dimensional application of finite element analysis. Med Eng Phys 2003;25:141-7.
    • (2003) Med Eng Phys , vol.25 , pp. 141-147
    • Chen, B.K.1    Clark, G.M.2    Jones, R.3
  • 9
    • 0029868754 scopus 로고    scopus 로고
    • Improved and simplified methods for specifying positions of the electrode bands of a cochlear implant array
    • Cohen LT, Xu J, Xu SA, et al. Improved and simplified methods for specifying positions of the electrode bands of a cochlear implant array. Am J Otol 1996;17:859-65.
    • (1996) Am J Otol , vol.17 , pp. 859-865
    • Cohen, L.T.1    Xu, J.2    Xu, S.A.3
  • 10
    • 4744344929 scopus 로고    scopus 로고
    • Stiffness properties for Nucleus standard straight and Contour electrode arrays
    • Kha HN, Chen BK, Clark GM, et al. Stiffness properties for Nucleus standard straight and Contour electrode arrays. Med Eng Phys 2004;26:677-85.
    • (2004) Med Eng Phys , vol.26 , pp. 677-685
    • Kha, H.N.1    Chen, B.K.2    Clark, G.M.3
  • 12
    • 33745477619 scopus 로고    scopus 로고
    • Determination of frictional conditions between electrode array and endosteum lining for use in cochlear implant models
    • Kha HN, Chen BK. Determination of frictional conditions between electrode array and endosteum lining for use in cochlear implant models. J Biomech 2006;39:1752-6.
    • (2006) J Biomech , vol.39 , pp. 1752-1756
    • Kha, H.N.1    Chen, B.K.2
  • 13
    • 0023093307 scopus 로고
    • Characterization of mechanical properties of single electrodes and multi-electrodes
    • Patrick JF, MacFarlane JC. Characterization of mechanical properties of single electrodes and multi-electrodes. Ann Otol Rhinol Laryngol 1987;96:46-8.
    • (1987) Ann Otol Rhinol Laryngol , vol.96 , pp. 46-48
    • Patrick, J.F.1    MacFarlane, J.C.2