메뉴 건너뛰기




Volumn 39, Issue 9, 2006, Pages 1752-1756

Determination of frictional conditions between electrode array and endosteum lining for use in cochlear implant models

Author keywords

Cochlear implant (CI); Contour array; Endosteum lining; Friction coefficient; Nucleus straight array

Indexed keywords

CONTOUR MEASUREMENT; ELECTRODES; FRICTION MATERIALS; LUBRICANTS; MATHEMATICAL MODELS;

EID: 33745477619     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2005.04.031     Document Type: Article
Times cited : (21)

References (33)
  • 1
    • 0347926364 scopus 로고    scopus 로고
    • Evaluation of trajectories and contact pressures for the straight Nucleus cochlear implant electrode array-a two-dimensional application of finite element analysis
    • Chen B.K., Clark G.M., and Jones R. Evaluation of trajectories and contact pressures for the straight Nucleus cochlear implant electrode array-a two-dimensional application of finite element analysis. Medical Engineering and Physics 25 (2003) 141-147
    • (2003) Medical Engineering and Physics , vol.25 , pp. 141-147
    • Chen, B.K.1    Clark, G.M.2    Jones, R.3
  • 3
    • 0035038241 scopus 로고    scopus 로고
    • Psychophysics of a prototype peri-modiolar cochlear implant electrode array
    • Cohen L.T., Saunders E., and Clark G.M. Psychophysics of a prototype peri-modiolar cochlear implant electrode array. Journal of Hearing Research 155 (2001) 1-2
    • (2001) Journal of Hearing Research , vol.155 , pp. 1-2
    • Cohen, L.T.1    Saunders, E.2    Clark, G.M.3
  • 4
    • 0016841087 scopus 로고
    • Stress-strain relationships during uniform and non-uniform expansion of isolated lung
    • D'Angelo E. Stress-strain relationships during uniform and non-uniform expansion of isolated lung. Respiratory Physiology & Neurobiology 23 (1975) 87-107
    • (1975) Respiratory Physiology & Neurobiology , vol.23 , pp. 87-107
    • D'Angelo, E.1
  • 6
    • 0025156574 scopus 로고
    • A new assessment in vitro of human salivary lubrication using a compliant substrate
    • Gans R.F., Watson G.E., and Tabak L.A. A new assessment in vitro of human salivary lubrication using a compliant substrate. Archives Oral Biology 35 7 (1990) 487-492
    • (1990) Archives Oral Biology , vol.35 , Issue.7 , pp. 487-492
    • Gans, R.F.1    Watson, G.E.2    Tabak, L.A.3
  • 7
    • 0027576491 scopus 로고
    • Water lubrication of polyurethane grafted with dimethylacrylamide for medical use
    • Ikeuchi K., Takii T., Norikane H., Tomita N., Ohsumi T., Uyama Y., and Ikada Y. Water lubrication of polyurethane grafted with dimethylacrylamide for medical use. Wear 161 (1993) 179-185
    • (1993) Wear , vol.161 , pp. 179-185
    • Ikeuchi, K.1    Takii, T.2    Norikane, H.3    Tomita, N.4    Ohsumi, T.5    Uyama, Y.6    Ikada, Y.7
  • 8
    • 33745438106 scopus 로고    scopus 로고
    • ISO 5725-2, 1994. Accuracy (trueness and precision) of measurement methods and results-Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method.
  • 9
    • 0037389833 scopus 로고    scopus 로고
    • Cochlear implant failure: imaging evaluation of the electrode course
    • Jain R., and Mukherji S.K. Cochlear implant failure: imaging evaluation of the electrode course. Clinical Radiology 58 (2003) 288-293
    • (2003) Clinical Radiology , vol.58 , pp. 288-293
    • Jain, R.1    Mukherji, S.K.2
  • 10
    • 0023121862 scopus 로고
    • Multi-channel intracochlear electrodes: mechanism of insertion trauma
    • Kennedy D.W. Multi-channel intracochlear electrodes: mechanism of insertion trauma. Laryngoscope 97 (1987) 42-49
    • (1987) Laryngoscope , vol.97 , pp. 42-49
    • Kennedy, D.W.1
  • 11
    • 4744344929 scopus 로고    scopus 로고
    • Stiffness properties for Nucleus standard straight and Contour electrode arrays
    • Kha H.N., Chen B.K., Clark G.M., and Jones R. Stiffness properties for Nucleus standard straight and Contour electrode arrays. Medical Engineering and Physics 26 (2004) 677-685
    • (2004) Medical Engineering and Physics , vol.26 , pp. 677-685
    • Kha, H.N.1    Chen, B.K.2    Clark, G.M.3    Jones, R.4
  • 12
    • 0031851977 scopus 로고    scopus 로고
    • Spatial resolution of cochlear implants: The electrical field and excitation of auditory afferents
    • Kral A., Hartmann R., Mortazavi D., and Kline R. Spatial resolution of cochlear implants: The electrical field and excitation of auditory afferents. Hearing Research 121 (1998) 11-28
    • (1998) Hearing Research , vol.121 , pp. 11-28
    • Kral, A.1    Hartmann, R.2    Mortazavi, D.3    Kline, R.4
  • 13
    • 1842853914 scopus 로고    scopus 로고
    • Experimental verification of the role of interstitial fluid pressurization in cartilage lubrication
    • Krishnan R., Kopacz M., and Ateshian G.A. Experimental verification of the role of interstitial fluid pressurization in cartilage lubrication. Journal of Orthopaedic Research 22 (2004) 565-570
    • (2004) Journal of Orthopaedic Research , vol.22 , pp. 565-570
    • Krishnan, R.1    Kopacz, M.2    Ateshian, G.A.3
  • 14
    • 0036237675 scopus 로고    scopus 로고
    • Intracochlear insertion of electrodes using hyaluronic acid in cochlear implants
    • Laszig R., Ridder G.J., and Fradis M. Intracochlear insertion of electrodes using hyaluronic acid in cochlear implants. Journal of Laryngology and Otology 116 5 (2002) 371-372
    • (2002) Journal of Laryngology and Otology , vol.116 , Issue.5 , pp. 371-372
    • Laszig, R.1    Ridder, G.J.2    Fradis, M.3
  • 15
    • 0027712559 scopus 로고
    • Cochlear implants: New perspectives
    • Fraysse B., and Deguine O. (Eds), Basel, Karger
    • Lehnhardt E. Cochlear implants: New perspectives. In: Fraysse B., and Deguine O. (Eds). Advances in Otorhinolaryngology vol. 48 (1993), Basel, Karger 62-64
    • (1993) Advances in Otorhinolaryngology , vol.48 , pp. 62-64
    • Lehnhardt, E.1
  • 17
    • 33745470198 scopus 로고    scopus 로고
    • Meriam, J.L., Kraige, L.G., 1993. Engineering Mechanics, vol. 1, Statics, third ed. John Wiley & Sons Inc., USA, pp. 389-390.
  • 19
    • 0031106697 scopus 로고    scopus 로고
    • Tribological evaluation of oxidized zirconium using an articular cartilage counterface: a novel material for potential use in hemiarthroplasty
    • Patel A.M., and Spector M. Tribological evaluation of oxidized zirconium using an articular cartilage counterface: a novel material for potential use in hemiarthroplasty. Biomaterials 18 (1997) 441-447
    • (1997) Biomaterials , vol.18 , pp. 441-447
    • Patel, A.M.1    Spector, M.2
  • 20
    • 0029081792 scopus 로고
    • Effects of glycerin, hyaluronic acid, and hydroxypropyl methylcellulose on the spiral ganglion of the guinea pig cochlea
    • Roland Jr. J.T., Magardino T.M., Go J.T., et al. Effects of glycerin, hyaluronic acid, and hydroxypropyl methylcellulose on the spiral ganglion of the guinea pig cochlea. Ann. Otol. Rhinol. Laryngol. 166 Suppl. (1995) 64-68
    • (1995) Ann. Otol. Rhinol. Laryngol. , vol.166 , Issue.SUPPL , pp. 64-68
    • Roland Jr., J.T.1    Magardino, T.M.2    Go, J.T.3
  • 21
    • 0037212673 scopus 로고    scopus 로고
    • Friction between human finger flexor tendons and pulleys at high loads
    • Schweizer A., Frank O., Ochsner P.E., and Jacob H.A.C. Friction between human finger flexor tendons and pulleys at high loads. Biomechanics 36 (2003) 63-71
    • (2003) Biomechanics , vol.36 , pp. 63-71
    • Schweizer, A.1    Frank, O.2    Ochsner, P.E.3    Jacob, H.A.C.4
  • 23
    • 0022002625 scopus 로고
    • Banded intracochlear electrode array: Evaluation of insertion trauma in human temporal bones
    • Shepherd R.K., Pyman B.C., Clark G.M., and Webb B.L. Banded intracochlear electrode array: Evaluation of insertion trauma in human temporal bones. Otology, Rhinology and Laryngology 94 (1985) 55-59
    • (1985) Otology, Rhinology and Laryngology , vol.94 , pp. 55-59
    • Shepherd, R.K.1    Pyman, B.C.2    Clark, G.M.3    Webb, B.L.4
  • 24
    • 33745435874 scopus 로고    scopus 로고
    • The design and development of peri-modiolar electrode array [online]. Available from: http://www.ci-centrum.de/CI-info/Nucleus-%204pp.pdf (Accessed 12 September 2002).
  • 26
  • 27
    • 0029408310 scopus 로고
    • Recent developments in the tribology of artificial joints
    • Unsworth A. Recent developments in the tribology of artificial joints. Tribology International 28 7 (1995) 485-495
    • (1995) Tribology International , vol.28 , Issue.7 , pp. 485-495
    • Unsworth, A.1
  • 28
    • 0031214403 scopus 로고    scopus 로고
    • The normal stress effect and equilibrium friction coefficient of articular cartilage under steady frictional shear
    • Wang H., and Ateshian G.A. The normal stress effect and equilibrium friction coefficient of articular cartilage under steady frictional shear. Biomechanics 30 8 (1997) 771-776
    • (1997) Biomechanics , vol.30 , Issue.8 , pp. 771-776
    • Wang, H.1    Ateshian, G.A.2
  • 32
    • 0036315554 scopus 로고    scopus 로고
    • Remodeling of the gliding surface after flexor tendon repair in a canine model in vitro
    • Zhao C., Amadio P.C., Momose T., Zobitz M.E., Couvreur P., and An K.N. Remodeling of the gliding surface after flexor tendon repair in a canine model in vitro. Orthopaedic Research 20 (2002) 857-862
    • (2002) Orthopaedic Research , vol.20 , pp. 857-862
    • Zhao, C.1    Amadio, P.C.2    Momose, T.3    Zobitz, M.E.4    Couvreur, P.5    An, K.N.6
  • 33
    • 0031231573 scopus 로고    scopus 로고
    • Comparison of the friction properties of four ceramic materials for joint replacements
    • Zhou Y.S., Ikeuchi K., and Ohashi M. Comparison of the friction properties of four ceramic materials for joint replacements. Wear 210 (1997) 171-177
    • (1997) Wear , vol.210 , pp. 171-177
    • Zhou, Y.S.1    Ikeuchi, K.2    Ohashi, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.