Volumn 36, Issue 7, 2012, Pages 542-551

Improving the correction of eddy current-induced distortion in diffusion-weighted images by excluding signals from the cerebral spinal fluid

Author keywords

Diffusion tensor imaging; Diffusion weighted imaging; Distortion correction; Eddy current; Iterative cross correlation; Mutual information

Indexed keywords

AFFECTING FACTORS; BRAIN VENTRICLES; CEREBRAL SPINAL FLUIDS; CORRELATION COEFFICIENT; CROSS CORRELATIONS; DIFFUSION WEIGHTED IMAGES; DIFFUSION WEIGHTED IMAGING; DISTORTION CORRECTION; ERROR SOURCES; ERROR TOLERANCE; GRADIENT BASED; MUTUAL INFORMATIONS; PROCESS DATA;

EID: 84865564707     PISSN: 08956111     EISSN: 18790771     Source Type: Journal    
DOI: 10.1016/j.compmedimag.2012.06.004     Document Type: Article
Times cited : (8)

References (29)
  • 1
    • 0025323825 scopus 로고
    • Diffusion-weighted MR imaging of anisotropic water diffusion in cat central nervous system
    • Moseley M.E., Cohen Y., Kucharczyk J., Mintorovitch J., Asgari H.S., Wendland M.F., et al. Diffusion-weighted MR imaging of anisotropic water diffusion in cat central nervous system. Radiology 1990, 176:439-445.
    • (1990) Radiology , vol.176 , pp. 439-445
    • Moseley, M.E.1    Cohen, Y.2    Kucharczyk, J.3    Mintorovitch, J.4    Asgari, H.S.5    Wendland, M.F.6
  • 2
    • 0030162959 scopus 로고    scopus 로고
    • Microstructural and physiological features of tissues elucidated by quantitative-diffusion-tensor MRI
    • Basser P.J., Pierpaoli C. Microstructural and physiological features of tissues elucidated by quantitative-diffusion-tensor MRI. J Magn Reson B 1996, 111:209-219.
    • (1996) J Magn Reson B , vol.111 , pp. 209-219
    • Basser, P.J.1    Pierpaoli, C.2
  • 3
    • 61649101493 scopus 로고    scopus 로고
    • The ellipsoidal area ratio: an alternative anisotropy index for diffusion tensor imaging
    • Xu D., Cui J., Bansal R., Hao X., Liu J., Chen W., et al. The ellipsoidal area ratio: an alternative anisotropy index for diffusion tensor imaging. Magn Reson Imaging 2009, 27:311-323.
    • (2009) Magn Reson Imaging , vol.27 , pp. 311-323
    • Xu, D.1    Cui, J.2    Bansal, R.3    Hao, X.4    Liu, J.5    Chen, W.6
  • 5
    • 43949151247 scopus 로고
    • Self-compensating pulsed magnetic-field gradients for short recovery times
    • Wider G., Dotsch V., Wuthrich K. Self-compensating pulsed magnetic-field gradients for short recovery times. J Magn Reson Ser A 1994, 108:255-258.
    • (1994) J Magn Reson Ser A , vol.108 , pp. 255-258
    • Wider, G.1    Dotsch, V.2    Wuthrich, K.3
  • 6
    • 0030726221 scopus 로고    scopus 로고
    • Elimination of eddy current artifacts in diffusion-weighted echo-planar images: the use of bipolar gradients
    • Alexander A.L., Tsuruda J.S., Parker D.L. Elimination of eddy current artifacts in diffusion-weighted echo-planar images: the use of bipolar gradients. Magn Reson Med 1997, 38:1016-1021.
    • (1997) Magn Reson Med , vol.38 , pp. 1016-1021
    • Alexander, A.L.1    Tsuruda, J.S.2    Parker, D.L.3
  • 7
    • 0037229177 scopus 로고    scopus 로고
    • Reduction of eddy-current-induced distortion in diffusion MRI using a twice-refocused spin echo
    • Reese T.G., Heid O., Weisskoff R.M., Wedeen V.J. Reduction of eddy-current-induced distortion in diffusion MRI using a twice-refocused spin echo. Magn Reson Med 2003, 49:177-182.
    • (2003) Magn Reson Med , vol.49 , pp. 177-182
    • Reese, T.G.1    Heid, O.2    Weisskoff, R.M.3    Wedeen, V.J.4
  • 8
    • 0031978367 scopus 로고    scopus 로고
    • Characterization of and correction for eddy current artifacts in echo planar diffusion imaging
    • Jezzard P., Barnett A.S., Pierpaoli C. Characterization of and correction for eddy current artifacts in echo planar diffusion imaging. Magn Reson Med 1998, 39:801-812.
    • (1998) Magn Reson Med , vol.39 , pp. 801-812
    • Jezzard, P.1    Barnett, A.S.2    Pierpaoli, C.3
  • 9
    • 0032951005 scopus 로고    scopus 로고
    • Correction for eddy current induced Bo shifts in diffusion-weighted echo-planar imaging
    • Calamante F., Porter D.A., Gadian D.G., Connelly A. Correction for eddy current induced Bo shifts in diffusion-weighted echo-planar imaging. Magn Reson Med 1999, 41:95-102.
    • (1999) Magn Reson Med , vol.41 , pp. 95-102
    • Calamante, F.1    Porter, D.A.2    Gadian, D.G.3    Connelly, A.4
  • 10
    • 18244365359 scopus 로고    scopus 로고
    • K-Space correction of eddy-current-induced distortions in diffusion-weighted echo-planar imaging
    • Papadakis N.G., Smponias T., Berwick J., Mayhew J.E. k-Space correction of eddy-current-induced distortions in diffusion-weighted echo-planar imaging. Magn Reson Med 2005, 53:1103-1111.
    • (2005) Magn Reson Med , vol.53 , pp. 1103-1111
    • Papadakis, N.G.1    Smponias, T.2    Berwick, J.3    Mayhew, J.E.4
  • 11
    • 0029994241 scopus 로고    scopus 로고
    • Correction for distortion of echo-planar images used to calculate the apparent diffusion coefficient
    • Haselgrove J.C., Moore J.R. Correction for distortion of echo-planar images used to calculate the apparent diffusion coefficient. Magn Reson Med 1996, 36:960-964.
    • (1996) Magn Reson Med , vol.36 , pp. 960-964
    • Haselgrove, J.C.1    Moore, J.R.2
  • 12
    • 0032866744 scopus 로고    scopus 로고
    • Correction of eddy current-induced artefacts in diffusion tensor imaging using iterative cross-correlation
    • Bastin M.E. Correction of eddy current-induced artefacts in diffusion tensor imaging using iterative cross-correlation. Magn Reson Imaging 1999, 17:1011-1024.
    • (1999) Magn Reson Imaging , vol.17 , pp. 1011-1024
    • Bastin, M.E.1
  • 13
    • 0034768728 scopus 로고    scopus 로고
    • On the use of the FLAIR technique to improve the correction of eddy current induced artefacts in MR diffusion tensor imaging
    • Bastin M.E. On the use of the FLAIR technique to improve the correction of eddy current induced artefacts in MR diffusion tensor imaging. Magn Reson Imaging 2001, 19:937-950.
    • (2001) Magn Reson Imaging , vol.19 , pp. 937-950
    • Bastin, M.E.1
  • 14
    • 0033895720 scopus 로고    scopus 로고
    • On the use of water phantom images to calibrate and correct eddy current induced artefacts in MR diffusion tensor imaging
    • Bastin M.E., Armitage P.A. On the use of water phantom images to calibrate and correct eddy current induced artefacts in MR diffusion tensor imaging. Magn Reson Imaging 2000, 18:681-687.
    • (2000) Magn Reson Imaging , vol.18 , pp. 681-687
    • Bastin, M.E.1    Armitage, P.A.2
  • 15
    • 0345742632 scopus 로고    scopus 로고
    • Eddy current correction in diffusion-weighted imaging using pairs of images acquired with opposite diffusion gradient polarity
    • Bodammer N., Kaufmann J., Kanowski M., Tempelmann C. Eddy current correction in diffusion-weighted imaging using pairs of images acquired with opposite diffusion gradient polarity. Magn Reson Med 2004, 51:188-193.
    • (2004) Magn Reson Med , vol.51 , pp. 188-193
    • Bodammer, N.1    Kaufmann, J.2    Kanowski, M.3    Tempelmann, C.4
  • 17
    • 0032741073 scopus 로고    scopus 로고
    • Mapping eddy current induced fields for the correction of diffusion-weighted echo planar images
    • Horsfield M.A. Mapping eddy current induced fields for the correction of diffusion-weighted echo planar images. Magn Reson Imaging 1999, 17:1335-1345.
    • (1999) Magn Reson Imaging , vol.17 , pp. 1335-1345
    • Horsfield, M.A.1
  • 18
    • 0345742636 scopus 로고    scopus 로고
    • Comprehensive approach for correction of motion and distortion in diffusion-weighted MRI
    • Rohde G.K., Barnett A.S., Basser P.J., Marenco S., Pierpaoli C. Comprehensive approach for correction of motion and distortion in diffusion-weighted MRI. Magn Reson Med 2004, 51:103-114.
    • (2004) Magn Reson Med , vol.51 , pp. 103-114
    • Rohde, G.K.1    Barnett, A.S.2    Basser, P.J.3    Marenco, S.4    Pierpaoli, C.5
  • 19
    • 33746697689 scopus 로고    scopus 로고
    • Retrospective distortion correction for 3D MR diffusion tensor microscopy using mutual information and Fourier deformations
    • Mistry N.N., Hsu E.W. Retrospective distortion correction for 3D MR diffusion tensor microscopy using mutual information and Fourier deformations. Magn Reson Med 2006, 56:310-316.
    • (2006) Magn Reson Med , vol.56 , pp. 310-316
    • Mistry, N.N.1    Hsu, E.W.2
  • 20
    • 0031345518 scopus 로고    scopus 로고
    • Algorithm 778: L-BFGS-B: Fortran subroutines for large-scale bound-constrained optimization
    • Zhu C.Y., Byrd R.H., Lu P.H., Nocedal J. Algorithm 778: L-BFGS-B: Fortran subroutines for large-scale bound-constrained optimization. ACM Trans Math Softw 1997, 23:550-560.
    • (1997) ACM Trans Math Softw , vol.23 , pp. 550-560
    • Zhu, C.Y.1    Byrd, R.H.2    Lu, P.H.3    Nocedal, J.4
  • 22
    • 0034238080 scopus 로고    scopus 로고
    • Image registration by maximization of combined mutual information and gradient information
    • Pluim J.P., Maintz J.B., Viergever M.A. Image registration by maximization of combined mutual information and gradient information. IEEE Trans Med Imaging 2000, 19:809-814.
    • (2000) IEEE Trans Med Imaging , vol.19 , pp. 809-814
    • Pluim, J.P.1    Maintz, J.B.2    Viergever, M.A.3
  • 23
    • 48649101495 scopus 로고    scopus 로고
    • Efficient image registration by decoupled parameter estimation using gradient-based techniques and mutual information
    • Shams R., Kennedy R.A., Sadeghi P. Efficient image registration by decoupled parameter estimation using gradient-based techniques and mutual information. Proc. TENCON 2007 2007.
    • (2007) Proc. TENCON 2007
    • Shams, R.1    Kennedy, R.A.2    Sadeghi, P.3
  • 24
    • 0043028206 scopus 로고    scopus 로고
    • Mutual-information-based registration of medical images: a survey
    • Pluim J.P.W., Maintz J.B.A., Viergever M.A. Mutual-information-based registration of medical images: a survey. IEEE Trans Med Imaging 2003, 22:986-1004.
    • (2003) IEEE Trans Med Imaging , vol.22 , pp. 986-1004
    • Pluim, J.P.W.1    Maintz, J.B.A.2    Viergever, M.A.3
  • 27
    • 39549110427 scopus 로고    scopus 로고
    • Mutual information-based multimodal image registration using a novel joint histogram estimation
    • Lu X.S., Zhang S., Su H., Chen Y.Z. Mutual information-based multimodal image registration using a novel joint histogram estimation. Comput Med Imaging Graph 2008, 32:202-209.
    • (2008) Comput Med Imaging Graph , vol.32 , pp. 202-209
    • Lu, X.S.1    Zhang, S.2    Su, H.3    Chen, Y.Z.4
  • 28
    • 33947114412 scopus 로고    scopus 로고
    • A quantitative comparison of two methods to correct eddy current-induced distortions in DT-MRI
    • Munoz Maniega S., Bastin M.E., Armitage P.A. A quantitative comparison of two methods to correct eddy current-induced distortions in DT-MRI. Magn Reson Imaging 2007, 25:341-349.
    • (2007) Magn Reson Imaging , vol.25 , pp. 341-349
    • Munoz Maniega, S.1    Bastin, M.E.2    Armitage, P.A.3
  • 29
    • 77957306385 scopus 로고    scopus 로고
    • Correcting eddy current and motion effects by affine whole-brain registrations: evaluation of three-dimensional distortions and comparison with slicewise correction
    • Mohammadi S., Moller H.E., Kugel H., Muller D.K., Deppe M. Correcting eddy current and motion effects by affine whole-brain registrations: evaluation of three-dimensional distortions and comparison with slicewise correction. Magn Reson Med 2010, 64:1047-1056.
    • (2010) Magn Reson Med , vol.64 , pp. 1047-1056
    • Mohammadi, S.1    Moller, H.E.2    Kugel, H.3    Muller, D.K.4    Deppe, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.