메뉴 건너뛰기




Volumn 17, Issue 9, 1999, Pages 1335-1345

Mapping eddy current induced fields for the correction of diffusion- weighted echo planar images

Author keywords

Diffusion; Distortion; Echo planar; Warping

Indexed keywords

ARTICLE; IMAGE ANALYSIS; IMAGE QUALITY; MAGNETIC FIELD; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL;

EID: 0032741073     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0730-725X(99)00077-6     Document Type: Article
Times cited : (101)

References (17)
  • 1
    • 0026761501 scopus 로고
    • Fast magnetic resonance diffusion-weighted imaging of acute stroke
    • Warach S., Chien D., Li W., Ronthal M., Edelman R.R. Fast magnetic resonance diffusion-weighted imaging of acute stroke. Neurology. 42:1992;1717-1723.
    • (1992) Neurology , vol.42 , pp. 1717-1723
    • Warach, S.1    Chien, D.2    Li, W.3    Ronthal, M.4    Edelman, R.R.5
  • 4
    • 0028324684 scopus 로고
    • Correction of motional artefacts in diffusion-weighted MR images using navigator echoes
    • Ordidge R.J., Helpern J.A., Quing Z.X., Knight R.A., Nagesh V. Correction of motional artefacts in diffusion-weighted MR images using navigator echoes. Magn. Reson. Imaging. 12:1994;455-460.
    • (1994) Magn. Reson. Imaging , vol.12 , pp. 455-460
    • Ordidge, R.J.1    Helpern, J.A.2    Quing, Z.X.3    Knight, R.A.4    Nagesh, V.5
  • 5
    • 0028030441 scopus 로고
    • Analysis and correction of motion artefacts in diffusion-weighted MR imaging
    • Anderson A.W., Gore J.C. Analysis and correction of motion artefacts in diffusion-weighted MR imaging. Magn. Reson. Med. 32:1994;379-387.
    • (1994) Magn. Reson. Med. , vol.32 , pp. 379-387
    • Anderson, A.W.1    Gore, J.C.2
  • 7
    • 0029866438 scopus 로고    scopus 로고
    • Diffusion-weighted interleaved echo-planar imaging with a pair of orthogonal navigator echoes
    • Butts K., de Crespigny A.J., Pauly J.M., Moseley M.E. Diffusion-weighted interleaved echo-planar imaging with a pair of orthogonal navigator echoes. Magn. Reson. Med. 35:1996;763-770.
    • (1996) Magn. Reson. Med. , vol.35 , pp. 763-770
    • Butts, K.1    De Crespigny, A.J.2    Pauly, J.M.3    Moseley, M.E.4
  • 8
    • 0031978367 scopus 로고    scopus 로고
    • Characterization of and correction for eddy current artifacts in echo planar diffusion imaging
    • Jezzard P., Barnett A.S., Pierpaoli C. Characterization of and correction for eddy current artifacts in echo planar diffusion imaging. Magn. Reson. Med. 39:1998;801-812.
    • (1998) Magn. Reson. Med. , vol.39 , pp. 801-812
    • Jezzard, P.1    Barnett, A.S.2    Pierpaoli, C.3
  • 9
    • 0029994241 scopus 로고    scopus 로고
    • Correction for distortion of echo-planar images used to calculate the apparent diffusion coefficient
    • Haselgrove J.C., Moore J.R. Correction for distortion of echo-planar images used to calculate the apparent diffusion coefficient. Magn. Reson. Med. 36:1996;960-964.
    • (1996) Magn. Reson. Med. , vol.36 , pp. 960-964
    • Haselgrove, J.C.1    Moore, J.R.2
  • 10
    • 0032835247 scopus 로고    scopus 로고
    • Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
    • Jones D.K., Horsfield M.A., Simmons A. Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging. Magn. Reson. Med. 42:1999;515-525.
    • (1999) Magn. Reson. Med. , vol.42 , pp. 515-525
    • Jones, D.K.1    Horsfield, M.A.2    Simmons, A.3
  • 12
    • 0001426032 scopus 로고
    • Analytical methods for the compensation of eddy current effects induced by pulsed magnetic field gradients in NMR systems
    • Johnson P., Westphal M., Schuff N. Analytical methods for the compensation of eddy current effects induced by pulsed magnetic field gradients in NMR systems. J. Magn. Reson. 90:1990;264-278.
    • (1990) J. Magn. Reson. , vol.90 , pp. 264-278
    • Johnson, P.1    Westphal, M.2    Schuff, N.3
  • 14
    • 0028067552 scopus 로고
    • Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeter
    • Maryanski M.J., Schulz R.J., Ibbott G.S., et al. Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeter. Phys. Med. Biol. 39:1994;1437-1455.
    • (1994) Phys. Med. Biol. , vol.39 , pp. 1437-1455
    • Maryanski, M.J.1    Schulz, R.J.2    Ibbott, G.S.3
  • 16
    • 0031028413 scopus 로고    scopus 로고
    • Automated three-dimensional registration of magnetic resonance and positron emission tomography brain images by multi-resolution optimization of voxel similarity measures
    • Studholme C., Hill D.L.G., Hawkes D.J. Automated three-dimensional registration of magnetic resonance and positron emission tomography brain images by multi-resolution optimization of voxel similarity measures. Med. Phys. 24:1997;25-35.
    • (1997) Med. Phys. , vol.24 , pp. 25-35
    • Studholme, C.1    Hill, D.L.G.2    Hawkes, D.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.