메뉴 건너뛰기




Volumn 34, Issue 8, 2012, Pages 1037-1040

Comparison of lead aVR " net QRS area" and " peak-to-peak amplitude" as indices of all limb electrocardiogram leads: Implications for the diagnosis, management, and follow-up in patients with heart failure

Author keywords

Amplitude of QRS complexes; AVR limb lead; Comparison of methods; Electrical potentials; Electrical signals; Electrocardiogram; Electrophysiology; Heart failure; Limb ECG leads; Net QRS area; Peripheral edema

Indexed keywords

COMPARISON OF METHODS; ELECTRICAL POTENTIAL; ELECTRICAL SIGNAL; HEART FAILURE; NET QRS AREA; PERIPHERAL EDEMA; QRS COMPLEXES;

EID: 84865561780     PISSN: 13504533     EISSN: 18734030     Source Type: Journal    
DOI: 10.1016/j.medengphy.2011.11.006     Document Type: Article
Times cited : (2)

References (15)
  • 1
    • 77951239000 scopus 로고    scopus 로고
    • Low-voltage electrocardiogram in patients with hypothyroidism and pericardial effusion: can serial comparative quantitative electrocardiography offer more?
    • Madias J.E. Low-voltage electrocardiogram in patients with hypothyroidism and pericardial effusion: can serial comparative quantitative electrocardiography offer more?. Cardiology 2010, 116:29-31.
    • (2010) Cardiology , vol.116 , pp. 29-31
    • Madias, J.E.1
  • 2
    • 0347624455 scopus 로고    scopus 로고
    • A comparison of 2-lead, 6-lead, and 12-lead ECGs in patients with changing edematous states: implications for the employment of quantitative electrocardiography in research and clinical applications
    • Madias J.E. A comparison of 2-lead, 6-lead, and 12-lead ECGs in patients with changing edematous states: implications for the employment of quantitative electrocardiography in research and clinical applications. Chest 2003, 124:2057-2063.
    • (2003) Chest , vol.124 , pp. 2057-2063
    • Madias, J.E.1
  • 3
    • 35548940280 scopus 로고    scopus 로고
    • Augmentation of ECG QRS complexes after fluid removal via a mechanical ultrafiltration pump in patients with congestive heart failure
    • Madias J.E., Guglin M.E. Augmentation of ECG QRS complexes after fluid removal via a mechanical ultrafiltration pump in patients with congestive heart failure. Ann Noninvasive Electrocardiol 2007, 12:291-297.
    • (2007) Ann Noninvasive Electrocardiol , vol.12 , pp. 291-297
    • Madias, J.E.1    Guglin, M.E.2
  • 4
    • 34548184859 scopus 로고    scopus 로고
    • Superiority of the limb leads over the precordial leads on the 12-lead ECG in monitoring fluctuating fluid overload in a patient with congestive heart failure
    • Madias J.E. Superiority of the limb leads over the precordial leads on the 12-lead ECG in monitoring fluctuating fluid overload in a patient with congestive heart failure. J Electrocardiol 2007, 40:395-399.
    • (2007) J Electrocardiol , vol.40 , pp. 395-399
    • Madias, J.E.1
  • 5
    • 58149229432 scopus 로고    scopus 로고
    • ECG leads I&II to evaluate diuresis of patients with congestive heart failure admitted to the hospital via the emergency department
    • Lumlertgul S., Chenthanakij B., Madias J.E. ECG leads I&II to evaluate diuresis of patients with congestive heart failure admitted to the hospital via the emergency department. Pacing Clin Electrophysiol 2009, 32:64-71.
    • (2009) Pacing Clin Electrophysiol , vol.32 , pp. 64-71
    • Lumlertgul, S.1    Chenthanakij, B.2    Madias, J.E.3
  • 6
    • 33947712041 scopus 로고    scopus 로고
    • Recommendations for the standardization and interpretation of the electrocardiogram: part I: the electrocardiogram and its technology: a scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Cardiology Foundation; and the Heart Rhythm Society: endorsed by the International Society for Computer
    • Kligfield P., Gettes L.S., Bailey J.J., Childers R., Deal B.J., Hancock E.W., et al. Recommendations for the standardization and interpretation of the electrocardiogram: part I: the electrocardiogram and its technology: a scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Cardiology Foundation; and the Heart Rhythm Society: endorsed by the International Society for Computerized Electrocardiology. Circulation 2007, 115:1306-1324.
    • (2007) Circulation , vol.115 , pp. 1306-1324
    • Kligfield, P.1    Gettes, L.S.2    Bailey, J.J.3    Childers, R.4    Deal, B.J.5    Hancock, E.W.6
  • 7
    • 77955433067 scopus 로고    scopus 로고
    • Differences in QRS axis measurements, classification of inferior myocardial infarction, and noise tolerance for 12-lead electrocardiograms acquired from monitoring electrode positions compared to standard locations
    • Welinder A., Wagner G.S., Maynard C., Pahlm O. Differences in QRS axis measurements, classification of inferior myocardial infarction, and noise tolerance for 12-lead electrocardiograms acquired from monitoring electrode positions compared to standard locations. Am J Cardiol 2010, 106:581-586.
    • (2010) Am J Cardiol , vol.106 , pp. 581-586
    • Welinder, A.1    Wagner, G.S.2    Maynard, C.3    Pahlm, O.4
  • 8
    • 55649110297 scopus 로고    scopus 로고
    • The standard 12-lead electrocardiogram: is the standard wrong?
    • Drew B.J. The standard 12-lead electrocardiogram: is the standard wrong?. J Electrocardiol 2007, 40:380-381.
    • (2007) J Electrocardiol , vol.40 , pp. 380-381
    • Drew, B.J.1
  • 9
    • 70449713364 scopus 로고    scopus 로고
    • AVR, an index of all ECG limb leads, with clinical utility for monitoring of patients with edematous states, including heart failure
    • Madias J.E. aVR, an index of all ECG limb leads, with clinical utility for monitoring of patients with edematous states, including heart failure. Pacing Clin Electrophysiol 2009, 32:1567-1576.
    • (2009) Pacing Clin Electrophysiol , vol.32 , pp. 1567-1576
    • Madias, J.E.1
  • 10
    • 84872829650 scopus 로고    scopus 로고
    • The 12-lead algorithm physician's guide, Publication number M 5000-9100. 1st ed. Hewlett Packard Str
    • 2, 71034, Böblingen, Germany: Phillips, Medizinsysteme Röblingen GmbH.
    • The 12-lead algorithm physician's guide, Publication number M 5000-9100. 1st ed. Hewlett Packard Str. 2, 71034, Böblingen, Germany: Phillips, Medizinsysteme Röblingen GmbH.
  • 11
    • 0004216962 scopus 로고
    • Little, Brown and Co., Boston, 207
    • Colton T. Statistics in medicine 1974, Little, Brown and Co., Boston, p. 134, 207. 1st ed.
    • (1974) Statistics in medicine , pp. 134
    • Colton, T.1
  • 13
    • 33846287574 scopus 로고    scopus 로고
    • The resting electrocardiogram in the management of patients with congestive heart failure: established applications and new insights
    • Madias J.E. The resting electrocardiogram in the management of patients with congestive heart failure: established applications and new insights. Pacing Clin Electrophysiol 2007, 30:123-128.
    • (2007) Pacing Clin Electrophysiol , vol.30 , pp. 123-128
    • Madias, J.E.1
  • 14
    • 0042320695 scopus 로고    scopus 로고
    • Augmentation of the amplitude of electrocardiographic QRS complexes immediately after hemodialysis: a study of 26 hemodialysis sessions of a single patient, aided by measurements of resistance, reactance, and impedance
    • Madias J.E., Narayan V. Augmentation of the amplitude of electrocardiographic QRS complexes immediately after hemodialysis: a study of 26 hemodialysis sessions of a single patient, aided by measurements of resistance, reactance, and impedance. J Electrocardiol 2003, 36:263-271.
    • (2003) J Electrocardiol , vol.36 , pp. 263-271
    • Madias, J.E.1    Narayan, V.2
  • 15
    • 0034841457 scopus 로고    scopus 로고
    • Anasarca-mediated attenuation of the amplitude of electrocardiogram complexes: a description of a heretofore unrecognized phenomenon
    • Madias J.E., Bazaz R., Agarwal H., Win M., Medepalli L. Anasarca-mediated attenuation of the amplitude of electrocardiogram complexes: a description of a heretofore unrecognized phenomenon. J Am Coll Cardiol 2001, 38:756-764.
    • (2001) J Am Coll Cardiol , vol.38 , pp. 756-764
    • Madias, J.E.1    Bazaz, R.2    Agarwal, H.3    Win, M.4    Medepalli, L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.