메뉴 건너뛰기




Volumn 42, Issue 9, 2012, Pages 906-914

A computer simulation model for Doppler ultrasound signals from pulsatile blood flow in stenosed vessels

Author keywords

Computer simulation model; Doppler ultrasound signal; Pulsatile flow; Stenosed vessel

Indexed keywords

ACOUSTIC FACTORS; CARDIAC CYCLES; CIRCULAR TUBES; COMPUTER SIMULATION MODEL; DOPPLER BLOOD FLOW SIGNALS; DOPPLER SIGNALS; DOPPLER ULTRASOUND SIGNALS; ELEMENTAL VOLUME; POWER SPECTRAL DENSITIES (PSD); PULSATILE BLOOD FLOW; SAMPLE VOLUME; STENOSED VESSEL; VELOCITY FIELD;

EID: 84865534657     PISSN: 00104825     EISSN: 18790534     Source Type: Journal    
DOI: 10.1016/j.compbiomed.2012.07.002     Document Type: Article
Times cited : (10)

References (24)
  • 1
    • 8844247928 scopus 로고    scopus 로고
    • Parameters describing motion in carotid artery plaques from ultrasound examination: a reproducibility study
    • Dahi T., Bang J., Ushakova A., Lydersen S., Myhre H.O. Parameters describing motion in carotid artery plaques from ultrasound examination: a reproducibility study. Ultrasound Med. Biol. 2004, 30:1133-1143.
    • (2004) Ultrasound Med. Biol. , vol.30 , pp. 1133-1143
    • Dahi, T.1    Bang, J.2    Ushakova, A.3    Lydersen, S.4    Myhre, H.O.5
  • 2
    • 26044477200 scopus 로고    scopus 로고
    • Noninvasive evaluation of carotid artery stenosis: indications, strategies, and accuracy
    • Romero J.M., Ackerman R.H., Dault N.A., Lev M.H. Noninvasive evaluation of carotid artery stenosis: indications, strategies, and accuracy. Neuroimaging Clin. N. Am. 2005, 15:351-365.
    • (2005) Neuroimaging Clin. N. Am. , vol.15 , pp. 351-365
    • Romero, J.M.1    Ackerman, R.H.2    Dault, N.A.3    Lev, M.H.4
  • 4
    • 1842455126 scopus 로고    scopus 로고
    • The wall signal removal in Doppler ultrasound systems based on recursive PCA
    • Tao Q., Wang Y., Fish P.J., Wang W., Cardoso J.C. The wall signal removal in Doppler ultrasound systems based on recursive PCA. Ultrasound Med. Biol. 2004, 30:369-379.
    • (2004) Ultrasound Med. Biol. , vol.30 , pp. 369-379
    • Tao, Q.1    Wang, Y.2    Fish, P.J.3    Wang, W.4    Cardoso, J.C.5
  • 6
    • 73649089666 scopus 로고    scopus 로고
    • Assessment of arterial distension based on continuous wave Doppler ultrasound with an improved Hilbert-huang processing
    • Zhang Y., Su N., Li Z., Gou Z., Chen Q., Zhang Y. Assessment of arterial distension based on continuous wave Doppler ultrasound with an improved Hilbert-huang processing. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 2010, 57:203-213.
    • (2010) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.57 , pp. 203-213
    • Zhang, Y.1    Su, N.2    Li, Z.3    Gou, Z.4    Chen, Q.5    Zhang, Y.6
  • 7
    • 34548129291 scopus 로고    scopus 로고
    • The removal of wall components in Doppler ultrasound signals by using the empirical mode decomposition algorithm
    • Zhang Y., Gao Y., Wang L., Chen J., Shi X. The removal of wall components in Doppler ultrasound signals by using the empirical mode decomposition algorithm. IEEE Trans. Biomed. Eng. 2007, 54:1631-1642.
    • (2007) IEEE Trans. Biomed. Eng. , vol.54 , pp. 1631-1642
    • Zhang, Y.1    Gao, Y.2    Wang, L.3    Chen, J.4    Shi, X.5
  • 8
    • 63149162776 scopus 로고    scopus 로고
    • A two-fluid model for pulsatile flow in catheterized blood vessels
    • Sankar D.S. A two-fluid model for pulsatile flow in catheterized blood vessels. Int. J. Non-Linear Mech. 2009, 44:337-351.
    • (2009) Int. J. Non-Linear Mech. , vol.44 , pp. 337-351
    • Sankar, D.S.1
  • 9
    • 33845689943 scopus 로고    scopus 로고
    • Doppler ultrasound signals simulation from vessels with various stenosis degrees
    • Fang X., Wang Y., Wang W.Q. Doppler ultrasound signals simulation from vessels with various stenosis degrees. Ultrasonics 2006, 44(Suppl. 1):e173-e177.
    • (2006) Ultrasonics , vol.44 , Issue.SUPPL. 1
    • Fang, X.1    Wang, Y.2    Wang, W.Q.3
  • 10
    • 33845863421 scopus 로고    scopus 로고
    • Pulsatile flow of Herschel-Bulkley fluid through stenosed arteries-a mathematical model
    • Sankar D.S., Hemalatha K. Pulsatile flow of Herschel-Bulkley fluid through stenosed arteries-a mathematical model. Int. J. Non-Linear Mech. 2006, 41:979-990.
    • (2006) Int. J. Non-Linear Mech. , vol.41 , pp. 979-990
    • Sankar, D.S.1    Hemalatha, K.2
  • 12
    • 84865534976 scopus 로고    scopus 로고
    • Real-Time Virtual Doppler Ultrasound, Thesis, University of Western Ontario, Canada
    • M. Khoshniat, Real-Time Virtual Doppler Ultrasound, Thesis, University of Western Ontario, Canada, 2004.
    • (2004)
    • Khoshniat, M.1
  • 13
    • 0030462817 scopus 로고    scopus 로고
    • Doppler ultrasound simulation model for pulsatile flow with nonaxial components
    • Oung H., Forsberg F. Doppler ultrasound simulation model for pulsatile flow with nonaxial components. Ultrason. Imaging 1996, 18:157-172.
    • (1996) Ultrason. Imaging , vol.18 , pp. 157-172
    • Oung, H.1    Forsberg, F.2
  • 14
    • 0028401173 scopus 로고
    • A theoretical and experimental analysis of the received signal from disturbed blood flow
    • Ferrara K.W., Algazi V.R. A theoretical and experimental analysis of the received signal from disturbed blood flow. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 1994, 41:172-184.
    • (1994) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.41 , pp. 172-184
    • Ferrara, K.W.1    Algazi, V.R.2
  • 15
    • 56749132344 scopus 로고    scopus 로고
    • 3D dynamic model of healthy and pathologic arteries for ultrasound technique evaluation
    • Balocco S., Basset O., Azencot J., Tortoli P., Cachard C. 3D dynamic model of healthy and pathologic arteries for ultrasound technique evaluation. Med. Phys. 2008, 35:5440-5450.
    • (2008) Med. Phys. , vol.35 , pp. 5440-5450
    • Balocco, S.1    Basset, O.2    Azencot, J.3    Tortoli, P.4    Cachard, C.5
  • 17
    • 84862936419 scopus 로고
    • Fudan University Presses, Shanghai, (in Chinese).
    • Z.R. Liu, Cardiovascular Hydrodynamics, Fudan University Presses, Shanghai, 1986 (in Chinese).
    • (1986) Cardiovascular Hydrodynamics
    • Liu, Z.R.1
  • 18
    • 1942432509 scopus 로고    scopus 로고
    • Velocity profile of periodic oscillatory blood flow in circular tube
    • (in Chinese)
    • Liu B., Guo B., Liu Z. Velocity profile of periodic oscillatory blood flow in circular tube. Chin. Q. Mech. 2002, 23:15-22. (in Chinese).
    • (2002) Chin. Q. Mech. , vol.23 , pp. 15-22
    • Liu, B.1    Guo, B.2    Liu, Z.3
  • 19
    • 84907877158 scopus 로고    scopus 로고
    • Velocity and shear stress of periodic oscillatory blood flow in vessel with stenosis
    • (in Chinese)
    • Sun H., Liu Z. Velocity and shear stress of periodic oscillatory blood flow in vessel with stenosis. Chin. Q. Mech. 2002, 23:148-156. (in Chinese).
    • (2002) Chin. Q. Mech. , vol.23 , pp. 148-156
    • Sun, H.1    Liu, Z.2
  • 23
    • 0030378068 scopus 로고    scopus 로고
    • Analysis of oscillatory flow in consideration of a plasma layer in arterial stenoses
    • Wang C., Liu Z. Analysis of oscillatory flow in consideration of a plasma layer in arterial stenoses. Appl. Math. Mech. (English Edition) 1996, 17:1127-1135.
    • (1996) Appl. Math. Mech. (English Edition) , vol.17 , pp. 1127-1135
    • Wang, C.1    Liu, Z.2
  • 24
    • 33646359414 scopus 로고    scopus 로고
    • Correction for broadening in Doppler blood flow spectrum estimated using wavelet transform
    • Zhang Y., Xu L., Chen J., Ma H., Shi X. Correction for broadening in Doppler blood flow spectrum estimated using wavelet transform. Med. Eng. Phys. 2006, 28:596-603.
    • (2006) Med. Eng. Phys. , vol.28 , pp. 596-603
    • Zhang, Y.1    Xu, L.2    Chen, J.3    Ma, H.4    Shi, X.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.