메뉴 건너뛰기




Volumn 30, Issue 3, 2004, Pages 369-379

The wall signal removal in Doppler ultrasound systems based on recursive PCA

Author keywords

Doppler ultrasound; High pass filter; PCA; Recursive process; SVD; Wall signal

Indexed keywords

ALGORITHMS; BLOOD; COMPUTER SIMULATION; DATA ACQUISITION; DOPPLER EFFECT; FILTERS (FOR FLUIDS); FLOW OF FLUIDS; HIGH PASS FILTERS; PRINCIPAL COMPONENT ANALYSIS; RECURSIVE FUNCTIONS;

EID: 1842455126     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ultrasmedbio.2003.11.014     Document Type: Article
Times cited : (19)

References (19)
  • 1
    • 0030313384 scopus 로고    scopus 로고
    • Amsterdam: IEEE Engineering in Medicine and Biology Society. Proceedings of the 18th Annual International Conference of the IEEE
    • Bastos C.A.C., Fish P.J., Vaz F. A model for generating Doppler ultrasound signals from pulsatile flow. 1:1996;121-122 IEEE Engineering in Medicine and Biology Society, Amsterdam. Proceedings of the 18th Annual International Conference of the IEEE.
    • (1996) A Model for Generating Doppler Ultrasound Signals from Pulsatile Flow , vol.1 , pp. 121-122
    • Bastos, C.A.C.1    Fish, P.J.2    Vaz, F.3
  • 2
    • 0032277072 scopus 로고    scopus 로고
    • Blood detection performance in moving tissue
    • Bjaerum S., Torp H. Blood detection performance in moving tissue. Proc IEEE Ultrason Sympos. 2:1998;1571-1574.
    • (1998) Proc IEEE Ultrason Sympos , vol.2 , pp. 1571-1574
    • Bjaerum, S.1    Torp, H.2
  • 4
    • 1842596522 scopus 로고    scopus 로고
    • Singapore: IEEE Engineering in Medicine and Biology Society. In: Proceedings of the International Congress on Medical and Biological Engineering, D1I-1145
    • Cardoso J.C., Fish P.J., Bastos C.A.C. Improved blood/wall signal separation in Doppler ultrasound. 2002;IEEE Engineering in Medicine and Biology Society, Singapore. In: Proceedings of the International Congress on Medical and Biological Engineering, D1I-1145.
    • (2002) Improved Blood/wall Signal Separation in Doppler Ultrasound
    • Cardoso, J.C.1    Fish, P.J.2    Bastos, C.A.C.3
  • 5
    • 0000775422 scopus 로고
    • Local-geometric-projection method for noise reduction in chaotic maps and flows
    • Cawley R., Hsu G.H. Local-geometric-projection method for noise reduction in chaotic maps and flows. Phys Rev A. 46:1992;3057-3082.
    • (1992) Phys Rev a , vol.46 , pp. 3057-3082
    • Cawley, R.1    Hsu, G.H.2
  • 7
    • 0020403104 scopus 로고
    • Some aspects of the relationship between instantaneous volumetric blood flow and continuous wave Doppler ultrasound recordings III
    • Evans D.H. Some aspects of the relationship between instantaneous volumetric blood flow and continuous wave Doppler ultrasound recordings III. Ultrasound Med Biol. 8:1982;617-623.
    • (1982) Ultrasound Med Biol , vol.8 , pp. 617-623
    • Evans, D.H.1
  • 10
    • 1842439838 scopus 로고    scopus 로고
    • Singapore: IEEE Engineering in Medicine and Biology Society. In: Proceedings of the International Congress on Medical and Biological Engineering, D1I-1200
    • Fish P.J., Cardoso J.C., Bastos C.A.C. Doppler ultrasound wall thump removal with minimal loss of low-flow signal. 2002;IEEE Engineering in Medicine and Biology Society, Singapore. In: Proceedings of the International Congress on Medical and Biological Engineering, D1I-1200.
    • (2002) Doppler Ultrasound Wall Thump Removal with Minimal Loss of Low-flow Signal
    • Fish, P.J.1    Cardoso, J.C.2    Bastos, C.A.C.3
  • 11
    • 0036992901 scopus 로고    scopus 로고
    • Adaptive clutter filtering via blind signal separation for lateral blood velocity measurement
    • Galippi C.M., Trahey G.E. Adaptive clutter filtering via blind signal separation for lateral blood velocity measurement. IEEE Ultrason Sympos Proc. 2:2002;1517-1521.
    • (2002) IEEE Ultrason Sympos Proc , vol.2 , pp. 1517-1521
    • Galippi, C.M.1    Trahey, G.E.2
  • 13
    • 0036197267 scopus 로고    scopus 로고
    • Movement artefact suppression in perfusion measurement using a multifrequency technique
    • Jansson T., Persson H.W., Lindstrom K. Movement artefact suppression in perfusion measurement using a multifrequency technique. Ultrasound Med Biol. 28:2002;69-79.
    • (2002) Ultrasound Med Biol , vol.28 , pp. 69-79
    • Jansson, T.1    Persson, H.W.2    Lindstrom, K.3
  • 14
    • 0036771561 scopus 로고    scopus 로고
    • A new high resolution color flow system using an eigendecomposition- based adaptive filter for clutter rejection
    • Kruse D.E., Ferrara K.W. A new high resolution color flow system using an eigendecomposition-based adaptive filter for clutter rejection. IEEE Tran Ultrason Ferroelec Freq Control. 49:2002;1384-1399.
    • (2002) IEEE Tran Ultrason Ferroelec Freq Control , vol.49 , pp. 1384-1399
    • Kruse, D.E.1    Ferrara, K.W.2
  • 15
    • 0030848446 scopus 로고    scopus 로고
    • Reduction of clutter component in Doppler ultrasound signals based on singular value decomposition: A simulation study
    • Ledoux L.A.F., Brands P.J., Hoeks A.P.G. Reduction of clutter component in Doppler ultrasound signals based on singular value decomposition A simulation study. Ultrason Imaging. 19:1997;1-18.
    • (1997) Ultrason Imaging , vol.19 , pp. 1-18
    • Ledoux, L.A.F.1    Brands, P.J.2    Hoeks, A.P.G.3
  • 17
    • 0035075949 scopus 로고    scopus 로고
    • Applying nonlinear noise reduction in the analysis of heart rate variability
    • Signorini M.G., Marchetti F., Cerutti S. Applying nonlinear noise reduction in the analysis of heart rate variability. IEEE Eng Med Biol. 20:2001;59-68.
    • (2001) IEEE Eng Med Biol , vol.20 , pp. 59-68
    • Signorini, M.G.1    Marchetti, F.2    Cerutti, S.3
  • 18
    • 0029979779 scopus 로고    scopus 로고
    • Comparison of Doppler signal analysis techniques for velocity waveform, turbulence and vortex measurement: A simulation study
    • Wang Y., Fish P.J. Comparison of Doppler signal analysis techniques for velocity waveform, turbulence and vortex measurement A simulation study. Ultrasound Med Biol. 22:1996;635-649.
    • (1996) Ultrasound Med Biol , vol.22 , pp. 635-649
    • Wang, Y.1    Fish, P.J.2
  • 19
    • 1842439120 scopus 로고    scopus 로고
    • Arterial Doppler signal simulation by time domain processing
    • Wang Y., Fish P.J. Arterial Doppler signal simulation by time domain processing. Eur J Ultrasound. 18:1996;170-233.
    • (1996) Eur J Ultrasound , vol.18 , pp. 170-233
    • Wang, Y.1    Fish, P.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.