메뉴 건너뛰기




Volumn 404, Issue 3, 2012, Pages 863-874

On-line solid-phase extraction high-performance liquid chromatography- tandem mass spectrometry for the quantitative analysis of tacrolimus in whole blood hemolyzate

Author keywords

Electrospray ionization mass spectrometry; Liquid chromatography; On line solid phase extraction; Tacrolimus; Whole blood analysis

Indexed keywords

ALKALINE PH; ANALYTES; BIOLOGICAL FLUIDS; BLOOD SAMPLES; BLOOD SAMPLING; ELECTROSPRAY IONIZATION MASS SPECTROMETRY; ETHYLENE DIAMINE TETRA-ACETIC ACID; EXTERNAL CALIBRATION; EXTRACTION EFFICIENCIES; IMMUNOSUPPRESSIVE DRUGS; LARGE BIOMOLECULES; LOWER LIMITS OF DETECTIONS; ON-LINE SOLID PHASE EXTRACTION; REACTION MONITORING; RESTRICTED ACCESS MATERIALS; SAMPLE PREPARATION; STATIONARY PHASE; TACROLIMUS; TANDEM MASS SPECTROMETRY; THERAPEUTIC MONITORING; WHOLE BLOOD;

EID: 84865530272     PISSN: 16182642     EISSN: 16182650     Source Type: Journal    
DOI: 10.1007/s00216-012-6201-6     Document Type: Article
Times cited : (12)

References (45)
  • 1
    • 84865514270 scopus 로고    scopus 로고
    • New directions in whole blood analysis: Dried blood spot analysis and beyond
    • Majors RE (2011) New directions in whole blood analysis: dried blood spot analysis and beyond. LC GC North America Jan. 2011:1-14
    • (2011) LC GC North America J.a.n. , vol.2011 , pp. 1-14
  • 4
    • 29744444606 scopus 로고    scopus 로고
    • Effects of total plasma protein concentration on plasma sodium, potassium and chloride measurements by an indirect ion selective electrode measuring system
    • Dimeski G, Barnett RJ (2005) Effects of total plasma protein concentration on plasma sodium, potassium and chloride measurements by an indirect ion selective electrode measuring system. Crit Care Resusc 7(1):12-15
    • (2005) Crit Care Resusc , vol.7 , Issue.1 , pp. 12-15
    • Dimeski, G.1    Barnett, R.J.2
  • 7
    • 0036001229 scopus 로고    scopus 로고
    • A clinical pharmacokinetic study of tacrolimus and sirolimus combination immunosuppression comparing simultaneous to separated administration
    • McAlister VC, Mahalati K, Peltekian KM, Fraser A, MacDonald AS (2002) A clinical pharmacokinetic study of tacrolimus and sirolimus combination immunosuppression comparing simultaneous to separated administration. Ther Drug Monit 24(3):346-350
    • (2002) Ther Drug Monit , vol.24 , Issue.3 , pp. 346-350
    • McAlister, V.C.1    Mahalati, K.2    Peltekian, K.M.3    Fraser, A.4    MacDonald, A.S.5
  • 8
    • 0035166897 scopus 로고    scopus 로고
    • Sirolimus: A comprehensive review
    • Kahan BD (2001) Sirolimus: a comprehensive review. Expert Opin Pharmacother 2(11):1903-1917
    • (2001) Expert Opin Pharmacother , vol.2 , Issue.11 , pp. 1903-1917
    • Kahan, B.D.1
  • 9
    • 0034751045 scopus 로고    scopus 로고
    • Therapeutic drug monitoring for immunosuppressants
    • Wong SH (2001) Therapeutic drug monitoring for immunosuppressants. Clin Chim Acta 313(1-2):241-253
    • (2001) Clin Chim Acta , vol.313 , Issue.1-2 , pp. 241-253
    • Wong, S.H.1
  • 10
    • 0032420378 scopus 로고    scopus 로고
    • Tacrolimus metabolite cross-reactivity in different tacrolimus assays
    • Murthy JN, Davis DL, Yatscoff RW, Soldin SJ (1998) Tacrolimus metabolite cross-reactivity in different tacrolimus assays. Clin Biochem 31(8):613-617
    • (1998) Clin Biochem , vol.31 , Issue.8 , pp. 613-617
    • Murthy, J.N.1    Davis, D.L.2    Yatscoff, R.W.3    Soldin, S.J.4
  • 12
    • 70449519965 scopus 로고    scopus 로고
    • Therapeutic monitoring of tacrolimus: Aberrant results by an immunoassay with automated pretreatment
    • Moscato D, Nonnato A, Adamo R, Vancheri M, Caropreso A (2010) Therapeutic monitoring of tacrolimus: aberrant results by an immunoassay with automated pretreatment. Clin Chim Acta 411(1-2):77-80
    • (2010) Clin Chim Acta , vol.411 , Issue.1-2 , pp. 77-80
    • Moscato, D.1    Nonnato, A.2    Adamo, R.3    Vancheri, M.4    Caropreso, A.5
  • 13
    • 64749097079 scopus 로고    scopus 로고
    • A rapid HPLC-MS/MS method for the simultaneous quantification of cyclosporine A, tacrolimus, sirolimus and everolimus in human blood samples
    • Seger C, Tentschert K, Stoggl W, Griesmacher A, Ramsay SL (2009) A rapid HPLC-MS/MS method for the simultaneous quantification of cyclosporine A, tacrolimus, sirolimus and everolimus in human blood samples. Nat Protoc 4(4):526-534
    • (2009) Nat Protoc , vol.4 , Issue.4 , pp. 526-534
    • Seger, C.1    Tentschert, K.2    Stoggl, W.3    Griesmacher, A.4    Ramsay, S.L.5
  • 14
    • 67649801479 scopus 로고    scopus 로고
    • Review of the newest HPLC methods with mass spectrometry detection for determination of immunosuppressive drugs in clinical practice
    • Korecka M, Shaw LM (2009) Review of the newest HPLC methods with mass spectrometry detection for determination of immunosuppressive drugs in clinical practice. Ann Transplant 14(2):61-72
    • (2009) Ann Transplant , vol.14 , Issue.2 , pp. 61-72
    • Korecka, M.1    Shaw, L.M.2
  • 15
    • 60449097232 scopus 로고    scopus 로고
    • Robust, high-throughput LC-MS/MS method for therapeutic drug monitoring of cyclosporine, tacrolimus, everolimus, and sirolimus in whole blood
    • Koster RA, Dijkers EC, Uges DR (2009) Robust, high-throughput LC-MS/MS method for therapeutic drug monitoring of cyclosporine, tacrolimus, everolimus, and sirolimus in whole blood. Ther Drug Monit 31(1):116-125
    • (2009) Ther Drug Monit , vol.31 , Issue.1 , pp. 116-125
    • Koster, R.A.1    Dijkers, E.C.2    Uges, D.R.3
  • 16
    • 0034306732 scopus 로고    scopus 로고
    • Automated, fast and sensitive quantification of drugs in blood by liquid chromatography-mass spectrometry with on-line extraction: Immunosuppressants
    • Christians U, Jacobsen W, Serkova N, Benet LZ, Vidal C, Sewing KF, Manns MP, Kirchner GI (2000) Automated, fast and sensitive quantification of drugs in blood by liquid chromatography-mass spectrometry with on-line extraction: immunosuppressants. J Chromatogr B: Biomed Sci Appl 748(1):41-53
    • (2000) J Chromatogr B: Biomed Sci Appl , vol.748 , Issue.1 , pp. 41-53
    • Christians, U.1    Jacobsen, W.2    Serkova, N.3    Benet, L.Z.4    Vidal, C.5    Sewing, K.F.6    Manns, M.P.7    Kirchner, G.I.8
  • 17
    • 77950353073 scopus 로고    scopus 로고
    • Quantitation of tacrolimus in whole blood using high performance liquid chromatographytandem mass spectrometry (HPLC-MS-MS)
    • Donaldson KJ, Shaw LM (2010) Quantitation of tacrolimus in whole blood using high performance liquid chromatographytandem mass spectrometry (HPLC-MS-MS). Methods Mol Biol 603:479-487
    • (2010) Methods Mol Biol , vol.603 , pp. 479-487
    • Donaldson, K.J.1    Shaw, L.M.2
  • 18
    • 63649092684 scopus 로고    scopus 로고
    • Dried blood spots as a sample collection technique for the determination of pharmacokinetics in clinical studies: Considerations for the validation of a quantitative bioanalytical method
    • Spooner N, Lad R, Barfield M (2009) Dried blood spots as a sample collection technique for the determination of pharmacokinetics in clinical studies: considerations for the validation of a quantitative bioanalytical method. Anal Chem 81 (4):1557-1563
    • (2009) Anal Chem , vol.81 , Issue.4 , pp. 1557-1563
    • Spooner, N.1    Lad, R.2    Barfield, M.3
  • 21
    • 0032704588 scopus 로고    scopus 로고
    • Pharmacokinetics of tacrolimus: Clinically relevant aspects
    • Undre NA, Stevenson P, Schafer A (1999) Pharmacokinetics of tacrolimus: clinically relevant aspects. Transplant Proc 31 (7A):21S-24S
    • (1999) Transplant Proc , vol.31 , Issue.7 A
    • Undre, N.A.1    Stevenson, P.2    Schafer, A.3
  • 22
    • 0035724321 scopus 로고    scopus 로고
    • Validation of methods to study the distribution and protein binding of tacrolimus in human blood
    • Zahir H, Nand RA, Brown KF, Tattam BN, McLachlan AJ (2001) Validation of methods to study the distribution and protein binding of tacrolimus in human blood. J Pharmacol Toxicol Methods 46 (1):27-35
    • (2001) J Pharmacol Toxicol Methods , vol.46 , Issue.1 , pp. 27-35
    • Zahir, H.1    Nand, R.A.2    Brown, K.F.3    Tattam, B.N.4    McLachlan, A.J.5
  • 23
    • 84865474542 scopus 로고    scopus 로고
    • SPE-LC-MS/MS analysis of immunosuppressants directly in whole blood using a unique in-line processing procedure
    • Morello R, Miljokovic J, Boos K-S (2007) SPE-LC-MS/MS analysis of immunosuppressants directly in whole blood using a unique in-line processing procedure. Ther Drug Monit 29(4):505
    • (2007) Ther Drug Monit , vol.29 , Issue.4 , pp. 505
    • Morello, R.1    Miljokovic, J.2    Boos, K.-S.3
  • 25
    • 0031740899 scopus 로고    scopus 로고
    • Quantitative analysis of sirolimus (Rapamycin) in blood by high-performance liquid chromatography-electrospray tandem mass spectrometry
    • Taylor PJ, Johnson AG (1998) Quantitative analysis of sirolimus (Rapamycin) in blood by high-performance liquid chromatography-electrospray tandem mass spectrometry. J Chromatogr B: Biomed Sci Appl 718(2):251-257
    • (1998) J Chromatogr B: Biomed Sci Appl , vol.718 , Issue.2 , pp. 251-257
    • Taylor, P.J.1    Johnson, A.G.2
  • 26
    • 0028302364 scopus 로고
    • Solid-phase extraction technique for the analysis of biological samples
    • Krishnan TR, Ibraham I (1994) Solid-phase extraction technique for the analysis of biological samples. J Pharm Biomed Anal 12 (3):287-294
    • (1994) J Pharm Biomed Anal , vol.12 , Issue.3 , pp. 287-294
    • Krishnan, T.R.1    Ibraham, I.2
  • 29
    • 84865451347 scopus 로고    scopus 로고
    • Multidimensional SPE-LC-MS/MS for therapeutic drug monitoring
    • Boos KS, Morello R (2007) Multidimensional SPE-LC-MS/MS for therapeutic drug monitoring. Ther Drug Monit 29(4):523-524
    • (2007) Ther Drug Monit , vol.29 , Issue.4 , pp. 523-524
    • Boos, K.S.1    Morello, R.2
  • 30
    • 1642564155 scopus 로고    scopus 로고
    • Restricted access materials and large particle supports for on-line sample preparation: An attractive approach for biological fluids analysis
    • Souverain S, Rudaz S, Veuthey JL (2004) Restricted access materials and large particle supports for on-line sample preparation: an attractive approach for biological fluids analysis. J Chromatogr B Analyt Technol Biomed Life Sci 801(2):141-156
    • (2004) J Chromatogr B Analyt Technol Biomed Life Sci , vol.801 , Issue.2 , pp. 141-156
    • Souverain, S.1    Rudaz, S.2    Veuthey, J.L.3
  • 31
    • 33745141189 scopus 로고    scopus 로고
    • Multidimensional on-line SPE for undisturbed LC-MS-MS analysis of basic drugs in biofluids
    • Georgi K, Boos KS (2006) Multidimensional on-line SPE for undisturbed LC-MS-MS analysis of basic drugs in biofluids. Chromatographia 63(11/12):523-531
    • (2006) Chromatographia , vol.63 , Issue.11-12 , pp. 523-531
    • Georgi, K.1    Boos, K.S.2
  • 34
    • 78650417838 scopus 로고    scopus 로고
    • Chemical analysis-decision limit, detection limit and determination limit under repeatability conditions-terms, methods, evaluation
    • 32465
    • Chemical analysis-decision limit, detection limit and determination limit under repeatability conditions-terms, methods, evaluation (2008). DIN 32465:2008-11
    • (2008) DIN , pp. 2008-11
  • 35
    • 0003852727 scopus 로고
    • their production, properties and use in LC. Wiley: Chichester
    • Scott RPW (ed) (1993) Silica gel and bonded phases. their production, properties and use in LC. Wiley: Chichester
    • (1993) Silica Gel and Bonded Phases
    • Scott, R.P.W.1
  • 36
    • 0033018785 scopus 로고    scopus 로고
    • High-performance liquid chromatography integrated solid-phase extraction in bioanalysis using restricted access precolumn packings
    • Boos K-S, Grimm C-H (1999) High-performance liquid chromatography integrated solid-phase extraction in bioanalysis using restricted access precolumn packings. TrAC, Trends Anal Chem 18(3):175-180
    • (1999) TrAC, Trends Anal Chem , vol.18 , Issue.3 , pp. 175-180
    • Boos, K.-S.1    Grimm, C.-H.2
  • 37
    • 0028575357 scopus 로고
    • Thermal broadening of the Soret band in heme complexes and in hemeproteins: Role of iron dynamics
    • Leone M, Cupane A, Militello V, Cordone L (1994) Thermal broadening of the Soret band in heme complexes and in hemeproteins: role of iron dynamics. Eur Biophys J 23(5):349-352
    • (1994) Eur Biophys J , vol.23 , Issue.5 , pp. 349-352
    • Leone, M.1    Cupane, A.2    Militello, V.3    Cordone, L.4
  • 39
    • 0020595002 scopus 로고
    • Characterization of heparins by high-performance size exclusion liquid-chromatography
    • Harenberg J, Devries JX (1983) Characterization of heparins by high-performance size exclusion liquid-chromatography. J Chromatogr 261(2):287-292
    • (1983) J Chromatogr , vol.261 , Issue.2 , pp. 287-292
    • Harenberg, J.1    Devries, J.X.2
  • 40
    • 9444241503 scopus 로고    scopus 로고
    • Heparine, thrombin-und faktor-xa-inhibitoren
    • Harenberg J, Fenyvesi T (2004) Heparine, Thrombin-und Faktor-Xa-Inhibitoren. Hämostaseologie 4:261-278
    • (2004) Hämostaseologie , vol.4 , pp. 261-278
    • Harenberg, J.1    Fenyvesi, T.2
  • 41
    • 0038409064 scopus 로고    scopus 로고
    • Investigation of EDTA anticoagulant in plasma to improve the throughput of liquid chromatography/tandem mass spectrometric assays
    • Sadagopan NP, Li W, Cook JA, Galvan B, Weller DL, Fountain ST, Cohen LH (2003) Investigation of EDTA anticoagulant in plasma to improve the throughput of liquid chromatography/tandem mass spectrometric assays. Rapid Commun Mass Spectrom 17(10):1065-1070
    • (2003) Rapid Commun Mass Spectrom , vol.17 , Issue.10 , pp. 1065-1070
    • Sadagopan, N.P.1    Li, W.2    Cook, J.A.3    Galvan, B.4    Weller, D.L.5    Fountain, S.T.6    Cohen, L.H.7
  • 42
    • 81055146012 scopus 로고    scopus 로고
    • Committee for Medical Products for Human Use . UK, London
    • Committee for Medical Products for Human Use (2012) Guideline on bioanalytical method validation. UK, London
    • (2012) Guideline on Bioanalytical Method Validation
  • 43
  • 44
    • 0030063763 scopus 로고    scopus 로고
    • Sensitive, specific quantitative analysis of tacrolimus (FK506) in blood by liquid chromatography-electrospray tandem mass spectrometry
    • Taylor PJ, Jones A, Balderson GA, Lynch SV, Norris RL, Pond SM (1996) Sensitive, specific quantitative analysis of tacrolimus (FK506) in blood by liquid chromatography-electrospray tandem mass spectrometry. Clin Chem 42(2):279-285
    • (1996) Clin Chem , vol.42 , Issue.2 , pp. 279-285
    • Taylor, P.J.1    Jones, A.2    Balderson, G.A.3    Lynch, S.V.4    Norris, R.L.5    Pond, S.M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.