메뉴 건너뛰기




Volumn 16, Issue 9, 2012, Pages 2891-2898

A highly sensitive electrochemiluminescence immunosensor based on magnetic nanoparticles and its application in CA125 determination

Author keywords

CA125; Electrochemiluminescence; Enzyme amplifier; Immunosensor; Magnetic nanoparticles

Indexed keywords

ANALYTES; CA125; CARBON PASTE ELECTRODE; DETECTION LIMITS; ELECTROCHEMILUMINESCENCE; ELECTROGENERATED CHEMILUMINESCENCE; ENZYMATIC REACTION; LUMINOLS; MAGNETIC NANOPARTICLES; SERUM SAMPLES;

EID: 84865527255     PISSN: 14328488     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10008-012-1719-2     Document Type: Article
Times cited : (23)

References (41)
  • 1
    • 4043156991 scopus 로고    scopus 로고
    • Magnetic nanoparticle design for medical diagnosis and therapy
    • Mornet S, Vasseur S, Grasset F, Duguet E (2004) Magnetic nanoparticle design for medical diagnosis and therapy. J Mater Chem 14:2161-2175
    • (2004) J Mater Chem , vol.14 , pp. 2161-2175
    • Mornet, S.1    Vasseur, S.2    Grasset, F.3    Duguet, E.4
  • 2
    • 67650672138 scopus 로고    scopus 로고
    • Biomedical applications of distally controlled magnetic nanoparticles
    • Corchero JL, Villaverde A (2009) Biomedical applications of distally controlled magnetic nanoparticles. Trends Biotechnol 27:468-476
    • (2009) Trends Biotechnol , vol.27 , pp. 468-476
    • Corchero, J.L.1    Villaverde, A.2
  • 3
    • 67349226688 scopus 로고    scopus 로고
    • Synthesis of magnetic nanoparticles composed by Prussian blue and glucose oxidase for preparing highly sensitive and selective glucose biosensor
    • Li JP, Wei XP, Yuan YH (2009) Synthesis of magnetic nanoparticles composed by Prussian blue and glucose oxidase for preparing highly sensitive and selective glucose biosensor. Sens Actuators B: Chem 139:400-406
    • (2009) Sens Actuators B: Chem , vol.139 , pp. 400-406
    • Li, J.P.1    Wei, X.P.2    Yuan, Y.H.3
  • 4
    • 41449086419 scopus 로고    scopus 로고
    • Fe3O4 magnetic nanoparticles as peroxidase mimetics and their applications in H2O2 and glucose detection
    • Wei H, Wang EK (2008) Fe3O4 magnetic nanoparticles as peroxidase mimetics and their applications in H2O2 and glucose detection. Anal Chem 80:2250-2254
    • (2008) Anal Chem , vol.80 , pp. 2250-2254
    • Wei, H.1    Wang, E.K.2
  • 5
    • 53649090036 scopus 로고    scopus 로고
    • Magnetic nanoparticles utilized in hemodialysis for the treatment of hyperhomocysteinemia: The new challenge of nanobiotechnology
    • Stamopoulos D (2008) Magnetic nanoparticles utilized in hemodialysis for the treatment of hyperhomocysteinemia: the new challenge of nanobiotechnology. Curr Nanosci 4:302-307
    • (2008) Curr Nanosci , vol.4 , pp. 302-307
    • Stamopoulos, D.1
  • 7
    • 35848947236 scopus 로고    scopus 로고
    • Detection of Creactive protein based on immunoassay using antibody-conjugated magnetic nanoparticles
    • Tsai HY, Hsu CF, Chiu IW, Bor Fuh C (2007) Detection of Creactive protein based on immunoassay using antibody-conjugated magnetic nanoparticles. Anal Chem 79:8416-8419
    • (2007) Anal Chem , vol.79 , pp. 8416-8419
    • Tsai, H.Y.1    Hsu, C.F.2    Chiu, I.W.3    Bor Fuh, C.4
  • 8
    • 42149182452 scopus 로고    scopus 로고
    • Theoretical analysis of a magnetic separator device for ex-vivo blood detoxification
    • Chen HT, Ebnerc AD, Ritterc JA, Kaminskid MD, Rosengarte AJ (2008) Theoretical analysis of a magnetic separator device for ex-vivo blood detoxification. Technology 43:996-1020
    • (2008) Technology , vol.43 , pp. 996-1020
    • Chen, H.T.1    Ebnerc, A.D.2    Ritterc, J.A.3    Kaminskid, M.D.4    Rosengarte, A.J.5
  • 9
    • 65349174488 scopus 로고    scopus 로고
    • Micromagnetic-microfluidic blood cleansing device
    • Yung CW, Fiering J, Mueller AJ, Ingber DE (2009) Micromagnetic- microfluidic blood cleansing device. Lab Chip 9:1171-1177
    • (2009) Lab Chip , vol.9 , pp. 1171-1177
    • Yung, C.W.1    Fiering, J.2    Mueller, A.J.3    Ingber, D.E.4
  • 11
    • 34347375937 scopus 로고    scopus 로고
    • Magnetic control of an electrochemical microfluidic device with an arrayed immunosensor for simultaneous multiple immunoassays
    • Tang DP, Yuan R, Chai YQ (2007) Magnetic control of an electrochemical microfluidic device with an arrayed immunosensor for simultaneous multiple immunoassays. Clin Chem 53:1323-1329
    • (2007) Clin Chem , vol.53 , pp. 1323-1329
    • Tang, D.P.1    Yuan, R.2    Chai, Y.Q.3
  • 13
    • 33745791962 scopus 로고    scopus 로고
    • 4@Ag nanoparticles coated carbon paste interface for studies of carcinoembryonic antigen in clinical immunoassay
    • 4@Ag nanoparticles coated carbon paste interface for studies of carcinoembryonic antigen in clinical immunoassay. J Phys Chem B 110:11640-11646
    • (2006) J Phys Chem B , vol.110 , pp. 11640-11646
    • Tang, D.P.1    Yuan, R.2    Chai, Y.Q.3
  • 14
    • 77951151249 scopus 로고    scopus 로고
    • An electrochemical immunosensor for carcinoembryonic antigen enhanced by self-assembled nanogold coatings on magnetic particles
    • Li JP, Gao HL, Chen ZQ, Wei XP, Yang CF (2010) An electrochemical immunosensor for carcinoembryonic antigen enhanced by self-assembled nanogold coatings on magnetic particles. Anal Chim Acta 665:98-104
    • (2010) Anal Chim Acta , vol.665 , pp. 98-104
    • Li, J.P.1    Gao, H.L.2    Chen, Z.Q.3    Wei, X.P.4    Yang, C.F.5
  • 15
    • 31844442230 scopus 로고    scopus 로고
    • Core-shell magnetic nanoparticles applied for immobilization of antibody on carbon paste electrode and amperometric immunosensing
    • Liu ZM, Yang HF, Li YF, Liu YL, Shen GL, Yu RQ (2006) Core-shell magnetic nanoparticles applied for immobilization of antibody on carbon paste electrode and amperometric immunosensing. Sens Actuators B: Chem 113:956-962
    • (2006) Sens Actuators B: Chem , vol.113 , pp. 956-962
    • Liu, Z.M.1    Yang, H.F.2    Li, Y.F.3    Liu, Y.L.4    Shen, G.L.5    Yu, R.Q.6
  • 16
    • 34248170619 scopus 로고    scopus 로고
    • Antibody-functionalized magnetic nano-particles for the detection of carcinoembryonic antigen using a flow-injection electrochemical device
    • Pan J, Yang QW (2007) Antibody-functionalized magnetic nano-particles for the detection of carcinoembryonic antigen using a flow-injection electrochemical device. Anal Bioanal Chem 388:279-286
    • (2007) Anal Bioanal Chem , vol.388 , pp. 279-286
    • Pan, J.1    Yang, Q.W.2
  • 17
    • 84865308802 scopus 로고    scopus 로고
    • Chemiluminescence enzyme immunoassay based on magnetic nanoparticles for detection of hepatocellular carcinoma marker glypican-3
    • Zhang QY, Chen H, Lin Z, Lin JM (2011) Chemiluminescence enzyme immunoassay based on magnetic nanoparticles for detection of hepatocellular carcinoma marker glypican-3. J Pharm Anal 1:166-174
    • (2011) J Pharm Anal , vol.1 , pp. 166-174
    • Zhang, Q.Y.1    Chen, H.2    Lin, Z.3    Lin, J.M.4
  • 18
    • 65249161141 scopus 로고    scopus 로고
    • Bifunctional nanoparticles with magnetization and luminescence
    • Wang LY, Yang ZH, Zhang Y, Wang L (2009) Bifunctional nanoparticles with magnetization and luminescence. J Phy Chem C 113:3955-3959
    • (2009) J Phy Chem C , vol.113 , pp. 3955-3959
    • Wang, L.Y.1    Yang, Z.H.2    Zhang, Y.3    Wang, L.4
  • 19
    • 80052336829 scopus 로고    scopus 로고
    • Highly sensitive label-free immunosensor for ochratoxin A based on functionalized magnetic nanoparticles and EIS/SPR detection
    • Zamfir LG, Geana I, Bourigua S, Rotariu L, Bala C, Errachid A, Jaffrezic-Renault N (2011) Highly sensitive label-free immunosensor for ochratoxin A based on functionalized magnetic nanoparticles and EIS/SPR detection. Sens Actuators B: Chem 159:178-184
    • (2011) Sens Actuators B: Chem , vol.159 , pp. 178-184
    • Zamfir, L.G.1    Geana, I.2    Bourigua, S.3    Rotariu, L.4    Bala, C.5    Errachid, A.6    Jaffrezic-Renault, N.7
  • 20
    • 37549047971 scopus 로고    scopus 로고
    • Electro-chemiluminescent biosensing
    • Marquette CA, Blum LJ (2008) Electro-chemiluminescent biosensing. Anal Bioanal Chem 390:155-168
    • (2008) Anal Bioanal Chem , vol.390 , pp. 155-168
    • Marquette, C.A.1    Blum, L.J.2
  • 21
  • 22
    • 18844453958 scopus 로고    scopus 로고
    • Gold nanoparticlecatalyzed luminol chemiluminescence and its analytical applications
    • Zhang ZF, Cui H, Lai CZ, Liu LJ (2005) Gold nanoparticlecatalyzed luminol chemiluminescence and its analytical applications. Anal Chem 77:3324-3329
    • (2005) Anal Chem , vol.77 , pp. 3324-3329
    • Zhang, Z.F.1    Cui, H.2    Lai, C.Z.3    Liu, L.J.4
  • 23
    • 37349072917 scopus 로고    scopus 로고
    • An ECL biosensor for glucose based on carbon-nanotube/Nafion film modified glass carbon electrode
    • Lin ZY, Chen JH, Chen GN (2008) An ECL biosensor for glucose based on carbon-nanotube/Nafion film modified glass carbon electrode. Electrochim Acta 53:2396-2401
    • (2008) Electrochim Acta , vol.53 , pp. 2396-2401
    • Lin, Z.Y.1    Chen, J.H.2    Chen, G.N.3
  • 24
    • 33846874359 scopus 로고    scopus 로고
    • Comparative studies on electro-generated chemiluminescence of luminol on gold nanoparticle modified electrodes
    • Dong YP, Cui H, Xu Y (2007) Comparative studies on electro-generated chemiluminescence of luminol on gold nanoparticle modified electrodes. Langmuir 23:523-529
    • (2007) Langmuir , vol.23 , pp. 523-529
    • Dong, Y.P.1    Cui, H.2    Xu, Y.3
  • 25
    • 78651263682 scopus 로고    scopus 로고
    • 4/CdSe-CdS nanoparticle/polyelectrolyte nanocomposite for highly efficient immunosensing of a cancer biomarker
    • 4/CdSe-CdS nanoparticle/polyelectrolyte nanocomposite for highly efficient immunosensing of a cancer biomarker. Chem Eur J 17:641-648
    • (2011) Chem Eur J , vol.17 , pp. 641-648
    • Jie, G.F.1    Wang, L.2    Zhang, S.S.3
  • 26
    • 77957552147 scopus 로고    scopus 로고
    • A novel electrochemiluminescence biosensor based on glucose oxidase immobilized on magnetic nanoparticles
    • Xiong ZG, Li JP, Tang L, Chen ZQ (2010) A novel electrochemiluminescence biosensor based on glucose oxidase immobilized on magnetic nanoparticles. Chin J Anal Chem 38:800-804
    • (2010) Chin J Anal Chem , vol.38 , pp. 800-804
    • Xiong, Z.G.1    Li, J.P.2    Tang, L.3    Chen, Z.Q.4
  • 27
    • 77956641906 scopus 로고    scopus 로고
    • Electrochemical and electrochemiluminescence determination of cancer cells based on aptamers and magnetic beads
    • Ding CF, Ge Y, Zhang SS (2010) Electrochemical and electrochemiluminescence determination of cancer cells based on aptamers and magnetic beads. Chem Eur J 16:10707-10714
    • (2010) Chem Eur J , vol.16 , pp. 10707-10714
    • Ding, C.F.1    Ge, Y.2    Zhang, S.S.3
  • 28
    • 0022591775 scopus 로고
    • Antigen detection by the monoclonal antibodies CA 19-9 and CA 125 in normal and tumor tissue and patients' sera
    • Dietel M, Arps H, Klapdor R, Muller-Hagen S, Sieck M, Hoffmann L (1986) Antigen detection by the monoclonal antibodies CA 19-9 and CA 125 in normal and tumor tissue and patients' sera. J Cancer Res Clin Oncol 111:257-265
    • (1986) J Cancer Res Clin Oncol , vol.111 , pp. 257-265
    • Dietel, M.1    Arps, H.2    Klapdor, R.3    Muller-Hagen, S.4    Sieck, M.5    Hoffmann, L.6
  • 29
    • 0033067405 scopus 로고    scopus 로고
    • Technical and clinical comparison of two fully automated methods for the immunoassay of CA 125 in serum
    • Yan GF, Ju HX, Liang ZC, Zhang TQ (1999) Technical and clinical comparison of two fully automated methods for the immunoassay of CA 125 in serum. J Immun Meth 255:1-8
    • (1999) J Immun Meth , vol.255 , pp. 1-8
    • Yan, G.F.1    Ju, H.X.2    Liang, Z.C.3    Zhang, T.Q.4
  • 30
    • 0027155115 scopus 로고
    • Monitoring cancer antigen 125 in serum of ovarian cancer patients after administration of 131I-Labeled F(ab′)2 fragments of OC125 antibody
    • Reinsberg J, Schultes B, Wagner U, Krebs D (1993) Monitoring cancer antigen 125 in serum of ovarian cancer patients after administration of 131I-Labeled F(ab′)2 fragments of OC125 antibody. Clin Chem 39:891-896
    • (1993) Clin Chem , vol.39 , pp. 891-896
    • Reinsberg, J.1    Schultes, B.2    Wagner, U.3    Krebs, D.4
  • 32
    • 57849107175 scopus 로고    scopus 로고
    • Streptavidin-functionalized three-dimensional ordered nanoporous silica film for highly efficient chemiluminescent immunosensing
    • Yang ZJ, Xie ZY, Liu H, Yan F, Ju HX (2008) Streptavidin-functionalized three-dimensional ordered nanoporous silica film for highly efficient chemiluminescent immunosensing. Adv Funct Mater 18:3991-3998
    • (2008) Adv Funct Mater , vol.18 , pp. 3991-3998
    • Yang, Z.J.1    Xie, Z.Y.2    Liu, H.3    Yan, F.4    Ju, H.X.5
  • 33
    • 0000019211 scopus 로고
    • Detection of glucose via electrochemiluminescence in a thin-layer cell with a planar optical waveguide
    • Kremeskotter J, Wilson R, Schiffrin DJ, Luff BJ, Wilkinson JS (1995) Detection of glucose via electrochemiluminescence in a thin-layer cell with a planar optical waveguide. Meas Sci Technol 6:1325-1328
    • (1995) Meas Sci Technol , vol.6 , pp. 1325-1328
    • Kremeskotter, J.1    Wilson, R.2    Schiffrin, D.J.3    Luff, B.J.4    Wilkinson, J.S.5
  • 34
    • 77955231615 scopus 로고    scopus 로고
    • Electrogenerated chemiluminescence of luminol at a carbon nanotube perfluorosulfonate polymer (Nafion) modified gold electrode
    • Dong YP (2010) Electrogenerated chemiluminescence of luminol at a carbon nanotube perfluorosulfonate polymer (Nafion) modified gold electrode. J Lumin 130:1539-1549
    • (2010) J Lumin , vol.130 , pp. 1539-1549
    • Dong, Y.P.1
  • 35
    • 0024963570 scopus 로고
    • Conformational states in β-lactamase: Molten-globule states at acidic and alkaline pH with high salt
    • Goto Y, Fink AL (1989) Conformational states in β-lactamase: molten-globule states at acidic and alkaline pH with high salt. Biochemistry 28:945-952
    • (1989) Biochemistry , vol.28 , pp. 945-952
    • Goto, Y.1    Fink, A.L.2
  • 36
    • 76849102209 scopus 로고    scopus 로고
    • Nanoparticle-based sandwich electrochemical immunoassay for carbohydrate antigen 125 with signal enhancement using enzyme-coated nanometer-sized enzyme-doped silica beads
    • Tang DP, Su BL, Tang J, Ren JJ, Chen GN (2010) Nanoparticle-based sandwich electrochemical immunoassay for carbohydrate antigen 125 with signal enhancement using enzyme-coated nanometer-sized enzyme-doped silica beads. Anal Chem 82:1527-1534
    • (2010) Anal Chem , vol.82 , pp. 1527-1534
    • Tang, D.P.1    Su, B.L.2    Tang, J.3    Ren, J.J.4    Chen, G.N.5
  • 37
    • 29244446800 scopus 로고    scopus 로고
    • Electrochemical immunoassay for CA125 based on cellulose acetate stabilized antigen/ colloidal gold nanoparticles membrane
    • Wu LN, Chen J, Du D, Ju HX (2006) Electrochemical immunoassay for CA125 based on cellulose acetate stabilized antigen/ colloidal gold nanoparticles membrane. Electrochim Acta 51:1208-1214
    • (2006) Electrochim Acta , vol.51 , pp. 1208-1214
    • Wu, L.N.1    Chen, J.2    Du, D.3    Ju, H.X.4
  • 38
    • 64649093149 scopus 로고    scopus 로고
    • Single conducting polymer nanowire chemiresistive label-free immunosensor for cancer biomarker
    • Bangar MA, Shirale DJ, Chen W, Myung NV, Mulchandani A (2009) Single conducting polymer nanowire chemiresistive label-free immunosensor for cancer biomarker. Anal Chem 81:2168-2175
    • (2009) Anal Chem , vol.81 , pp. 2168-2175
    • Bangar, M.A.1    Shirale, D.J.2    Chen, W.3    Myung, N.V.4    Mulchandani, A.5
  • 39
    • 34147162372 scopus 로고    scopus 로고
    • An amperometric immunosensor for separation-free immunoassay of CA125 based on its covalent immobilization coupled with thionine on carbon nanofiber
    • Wu LN, Yan F, Ju HX (2007) An amperometric immunosensor for separation-free immunoassay of CA125 based on its covalent immobilization coupled with thionine on carbon nanofiber. J Immunol Methods 322:12-19
    • (2007) J Immunol Methods , vol.322 , pp. 12-19
    • Wu, L.N.1    Yan, F.2    Ju, H.X.3
  • 40
    • 70349506773 scopus 로고    scopus 로고
    • Electrochemical sensing platform based on tris(2,2′-bipyridyl) cobalt(III) and multiwall carbon nanotubes-Nafion composite for immunoassay of carcinoma antigen-125
    • Chen SH, Yuan R, Chai YQ, Min LG, Li WJ, Xu Y (2009) Electrochemical sensing platform based on tris(2,2′-bipyridyl)cobalt(III) and multiwall carbon nanotubes-Nafion composite for immunoassay of carcinoma antigen-125. Electrochim Acta 54:7242-7247
    • (2009) Electrochim Acta , vol.54 , pp. 7242-7247
    • Chen, S.H.1    Yuan, R.2    Chai, Y.Q.3    Min, L.G.4    Li, W.J.5    Xu, Y.6
  • 41
    • 33645983368 scopus 로고    scopus 로고
    • Electrochemical immunobioanalysis for carcinoma antigen 125 based on thionine and gold nanoparticles-modified carbon paste interface
    • Tang DP, Yuan R, Chai YQ (2006) Electrochemical immunobioanalysis for carcinoma antigen 125 based on thionine and gold nanoparticles-modified carbon paste interface. Anal Chim Acta 564:158-165
    • (2006) Anal Chim Acta , vol.564 , pp. 158-165
    • Tang, D.P.1    Yuan, R.2    Chai, Y.Q.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.