메뉴 건너뛰기




Volumn 325-327, Issue , 2012, Pages 73-79

Self-correlation method for processing random phase signals in Fourier transform mass spectrometry

Author keywords

Fourier Transform Mass Spectrometry; Ion trap; Non destructive ion detection; Self correlation; Signal enhancement

Indexed keywords


EID: 84865486142     PISSN: 13873806     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijms.2012.06.013     Document Type: Article
Times cited : (2)

References (39)
  • 1
    • 0030461690 scopus 로고    scopus 로고
    • Fourier Transform Mass Spectrometry
    • I.J. Amster Fourier Transform Mass Spectrometry Journal of Mass Spectrometry 31 1996 1325 1337
    • (1996) Journal of Mass Spectrometry , vol.31 , pp. 1325-1337
    • Amster, I.J.1
  • 3
    • 0041408938 scopus 로고    scopus 로고
    • Electrostatic axially harmonic orbital trapping: A high-performance technique of mass analysis
    • A. Makarov Electrostatic axially harmonic orbital trapping: a high-performance technique of mass analysis Analytical Chemistry 72 2000 1156 1162
    • (2000) Analytical Chemistry , vol.72 , pp. 1156-1162
    • Makarov, A.1
  • 4
  • 6
    • 0000751135 scopus 로고
    • Cluster experiments in radio frequency Paul traps: Collisional relaxation and dissociation
    • J.H. Parks, S. Pollack, and W. Hill Cluster experiments in radio frequency Paul traps: collisional relaxation and dissociation The Journal of Chemical Physics 101 1994 6666 6685
    • (1994) The Journal of Chemical Physics , vol.101 , pp. 6666-6685
    • Parks, J.H.1    Pollack, S.2    Hill, W.3
  • 7
    • 0001268221 scopus 로고
    • Fourier transform ion cyclotron resonance spectroscopy
    • M.B. Comisarow, and A.G. Marshall Fourier transform ion cyclotron resonance spectroscopy Chemical Physics Letters 25 1974 282 283
    • (1974) Chemical Physics Letters , vol.25 , pp. 282-283
    • Comisarow, M.B.1    Marshall, A.G.2
  • 8
    • 49549153202 scopus 로고
    • Frequency-sweep fourier transform ion cyclotron resonance spectroscopy
    • M.B. Comisarow, and A.G. Marshall Frequency-sweep fourier transform ion cyclotron resonance spectroscopy Chemical Physics Letters 26 1974 489 490
    • (1974) Chemical Physics Letters , vol.26 , pp. 489-490
    • Comisarow, M.B.1    Marshall, A.G.2
  • 14
    • 0002572969 scopus 로고
    • Quadrupolar excitation and collisional cooling for axialization and high pressure trapping of ions in Fourier transform ion cyclotron resonance mass spectrometry
    • L. Schweikhard, S. Guan, and A.G. Marshall Quadrupolar excitation and collisional cooling for axialization and high pressure trapping of ions in Fourier transform ion cyclotron resonance mass spectrometry International Journal of Mass Spectrometry and Ion Processes 120 1992 71 83
    • (1992) International Journal of Mass Spectrometry and Ion Processes , vol.120 , pp. 71-83
    • Schweikhard, L.1    Guan, S.2    Marshall, A.G.3
  • 15
    • 0037099128 scopus 로고    scopus 로고
    • Surface-induced dissociation in a fourier transform ion cyclotron resonance mass spectrometer: Instrument design and evaluation
    • J. Laskin, E.V. Denisov, A.K. Shukla, S.E. Barlow, and J.H. Futrell Surface-induced dissociation in a fourier transform ion cyclotron resonance mass spectrometer: instrument design and evaluation Analytical Chemistry 74 2002 3255 3261
    • (2002) Analytical Chemistry , vol.74 , pp. 3255-3261
    • Laskin, J.1    Denisov, E.V.2    Shukla, A.K.3    Barlow, S.E.4    Futrell, J.H.5
  • 16
    • 4744352678 scopus 로고    scopus 로고
    • Broadband phase correction of FT-ICR mass spectra via simultaneous excitation and detection
    • S.C. Beu, G.T. Blakney, J.P. Quinn, C.L. Hendrickson, and A.G. Marshall Broadband phase correction of FT-ICR mass spectra via simultaneous excitation and detection Analytical Chemistry 76 2004 5756 5761
    • (2004) Analytical Chemistry , vol.76 , pp. 5756-5761
    • Beu, S.C.1    Blakney, G.T.2    Quinn, J.P.3    Hendrickson, C.L.4    Marshall, A.G.5
  • 17
    • 0000851292 scopus 로고
    • Automated phase correction of FT NMR-spectra by means of phase measurement based on dispersion versus absorption relation (DISPA)
    • E.C. Craig, and A.G. Marshall Automated phase correction of FT NMR-spectra by means of phase measurement based on dispersion versus absorption relation (DISPA) Journal of Magnetic Resonance 76 1988 458 475
    • (1988) Journal of Magnetic Resonance , vol.76 , pp. 458-475
    • Craig, E.C.1    Marshall, A.G.2
  • 20
    • 0033555329 scopus 로고    scopus 로고
    • Phase correction for collision model analysis and enhanced resolving power of Fourier transform ion cyclotron resonance mass spectra
    • B.A. Vining, R.E. Bossio, and A.G. Marshall Phase correction for collision model analysis and enhanced resolving power of Fourier transform ion cyclotron resonance mass spectra Analytical Chemistry 71 1999 460 467
    • (1999) Analytical Chemistry , vol.71 , pp. 460-467
    • Vining, B.A.1    Bossio, R.E.2    Marshall, A.G.3
  • 21
    • 78049516195 scopus 로고    scopus 로고
    • Automated broadband phase correction of fourier transform ion cyclotron resonance mass spectra
    • F. Xian, C.L. Hendrickson, G.T. Blakney, S.C. Beu, and A.G. Marshall Automated broadband phase correction of fourier transform ion cyclotron resonance mass spectra Analytical Chemistry 82 2010 8807 8812
    • (2010) Analytical Chemistry , vol.82 , pp. 8807-8812
    • Xian, F.1    Hendrickson, C.L.2    Blakney, G.T.3    Beu, S.C.4    Marshall, A.G.5
  • 22
    • 6144234381 scopus 로고
    • Theory of fourier-transform ion-cyclotron resonance mass spectroscopy-III. 1. Relaxation and spectral-line shape in Fourier-transform ion resonance spectroscopy
    • A.G. Marshall, M.B. Comisarow, and G. Parisod Theory of fourier-transform ion-cyclotron resonance mass spectroscopy-III. 1. Relaxation and spectral-line shape in Fourier-transform ion resonance spectroscopy Journal of Chemical Physics 71 1979 4434 4444
    • (1979) Journal of Chemical Physics , vol.71 , pp. 4434-4444
    • Marshall, A.G.1    Comisarow, M.B.2    Parisod, G.3
  • 23
    • 4244055957 scopus 로고
    • Dispersion versus absorption - Spectral-line shape analysis for radiofrequency and microwave spectrometry
    • A.G. Marshall, and D.C. Roe Dispersion versus absorption - spectral-line shape analysis for radiofrequency and microwave spectrometry Analytical Chemistry 50 1978 756 763
    • (1978) Analytical Chemistry , vol.50 , pp. 756-763
    • Marshall, A.G.1    Roe, D.C.2
  • 25
    • 0029388690 scopus 로고
    • Data reflection algorithm for spectral enhancement in Fourier-transform ICR and NMR spectroscopies
    • M.V. Gorshkov, and R.T. Kouzes Data reflection algorithm for spectral enhancement in Fourier-transform ICR and NMR spectroscopies Analytical Chemistry 67 1995 3412 3420
    • (1995) Analytical Chemistry , vol.67 , pp. 3412-3420
    • Gorshkov, M.V.1    Kouzes, R.T.2
  • 26
    • 0027120083 scopus 로고
    • Hartley/Hilbert transform spectroscopy: Absorption-mode resolution with magnitude-mode precision
    • C.P. Williams, and A.G. Marshall Hartley/Hilbert transform spectroscopy: absorption-mode resolution with magnitude-mode precision Analytical Chemistry 64 1992 916 923
    • (1992) Analytical Chemistry , vol.64 , pp. 916-923
    • Williams, C.P.1    Marshall, A.G.2
  • 27
    • 0009772461 scopus 로고
    • Resolution enhancement and parameter-estimation in Fourier-analysis
    • Y. Balcou Resolution enhancement and parameter-estimation in Fourier-analysis Rapid Communications in Mass Spectrometry 8 1994 942 944
    • (1994) Rapid Communications in Mass Spectrometry , vol.8 , pp. 942-944
    • Balcou, Y.1
  • 28
    • 0029151469 scopus 로고
    • Magnitude-mode multiple-derivative spectra for resolution enhancement without loss in signal-to-noise ratio in Fourier-Transform Spectroscopy
    • H.S. Kim, and A.G. Marshall Magnitude-mode multiple-derivative spectra for resolution enhancement without loss in signal-to-noise ratio in Fourier-Transform Spectroscopy Journal of Mass Spectrometry 30 1995 1237 1244
    • (1995) Journal of Mass Spectrometry , vol.30 , pp. 1237-1244
    • Kim, H.S.1    Marshall, A.G.2
  • 31
    • 18744411077 scopus 로고    scopus 로고
    • Improved peak detection and quantification of mass spectrometry data acquired from surface-enhanced laser desorption and ionization by denoising spectra with the undecimated discrete wavelet transform
    • K.R. Coombes, S. Tsavachidis, J.S. Morris, K.A. Baggerly, M.-C. Hung, and H.M. Kuerer Improved peak detection and quantification of mass spectrometry data acquired from surface-enhanced laser desorption and ionization by denoising spectra with the undecimated discrete wavelet transform PROTEOMICS 5 2005 4107 4117
    • (2005) PROTEOMICS , vol.5 , pp. 4107-4117
    • Coombes, K.R.1    Tsavachidis, S.2    Morris, J.S.3    Baggerly, K.A.4    Hung, M.-C.5    Kuerer, H.M.6
  • 32
    • 80053054267 scopus 로고    scopus 로고
    • Modeling of ion transient response to dipolar AC excitation in a quadrupole ion trap
    • W. Xu, W.J. Chappell, and Z. Ouyang Modeling of ion transient response to dipolar AC excitation in a quadrupole ion trap International Journal of Mass Spectrometry 308 2011 49 55
    • (2011) International Journal of Mass Spectrometry , vol.308 , pp. 49-55
    • Xu, W.1    Chappell, W.J.2    Ouyang, Z.3
  • 33
    • 0030999705 scopus 로고    scopus 로고
    • An introduction to quadrupole ion trap mass spectrometry
    • R.E. March An introduction to quadrupole ion trap mass spectrometry Journal of Mass Spectrometry 32 1997 351 369
    • (1997) Journal of Mass Spectrometry , vol.32 , pp. 351-369
    • March, R.E.1
  • 36
    • 0002991935 scopus 로고
    • Application of correlation-analysis techniques to mass-spectral data
    • K.G. Owens Application of correlation-analysis techniques to mass-spectral data Applied Spectroscopy Reviews 27 1992 1 49
    • (1992) Applied Spectroscopy Reviews , vol.27 , pp. 1-49
    • Owens, K.G.1
  • 37
    • 0032129491 scopus 로고    scopus 로고
    • Automation of data collection for matrix assisted laser desorption/ionization mass spectrometry using a correlative analysis algorithm
    • A.J. Nicola, A.I. Gusev, A. Proctor, and D.M. Hercules Automation of data collection for matrix assisted laser desorption/ionization mass spectrometry using a correlative analysis algorithm Analytical Chemistry 70 1998 3213 3219
    • (1998) Analytical Chemistry , vol.70 , pp. 3213-3219
    • Nicola, A.J.1    Gusev, A.I.2    Proctor, A.3    Hercules, D.M.4
  • 39
    • 0026514122 scopus 로고
    • Comparison of simca pattern-recognition and library search identification of hazardous compounds from mass-spectra
    • M. Sarker, W.G. Glen, L.B. Yin, W.J. Dunn, D.R. Scott, and S. Swanson Comparison of simca pattern-recognition and library search identification of hazardous compounds from mass-spectra Analytica Chimica Acta 257 1992 229 238
    • (1992) Analytica Chimica Acta , vol.257 , pp. 229-238
    • Sarker, M.1    Glen, W.G.2    Yin, L.B.3    Dunn, W.J.4    Scott, D.R.5    Swanson, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.