-
1
-
-
33746803555
-
Image formation by induced local interactions: Examples employing nuclear magnetic resonance
-
Lauterbur PC,. Image formation by induced local interactions: examples employing nuclear magnetic resonance. Nature 1973; 242: 190-191.
-
(1973)
Nature
, vol.242
, pp. 190-191
-
-
Lauterbur, P.C.1
-
2
-
-
13144294740
-
"Diffraction" and microscopy in solids and liquids by NMR
-
Mansfield P, Grannell PK,. "Diffraction" and microscopy in solids and liquids by NMR. Phys Rev B 1975; 12: 3618-3634.
-
(1975)
Phys Rev B
, vol.12
, pp. 3618-3634
-
-
Mansfield, P.1
Grannell, P.K.2
-
3
-
-
0017168510
-
Field focusing nuclear magnetic resonance (FONAR): Visualization of a tumor in a live animal
-
Damadian R, Minkoff L, Goldsmith M, Stanford M, Koutcher J,. Field focusing nuclear magnetic resonance (FONAR): visualization of a tumor in a live animal. Science 1976; 194: 1430-1432.
-
(1976)
Science
, vol.194
, pp. 1430-1432
-
-
Damadian, R.1
Minkoff, L.2
Goldsmith, M.3
Stanford, M.4
Koutcher, J.5
-
4
-
-
0019614402
-
Detectability of hepatomas in rat livers by nuclear magnetic resonance imaging
-
Davis PL, Kaufman L, Crooks LE, Miller TR,. 1981 Memorial Award Paper. Detectability of hepatomas in rat livers by nuclear magnetic resonance imaging. Invest Radiol 1981; 16: 354-359. (Pubitemid 11020616)
-
(1981)
Investigative Radiology
, vol.16
, Issue.5
, pp. 354-359
-
-
Davis, P.L.1
Kaufman, L.2
Crooks, L.E.3
Miller, T.R.4
-
5
-
-
0018893070
-
In vivo imaging of the rat anatomy with nulear magnetic resonance
-
Hansen G, Crooks L, Davis P, De Groot J, Herfkens R, Margulis A, Gooding C, Kaufman L, Hoenninger J, Arakawa M, McRee R, Watts J,. In vivo imaging of the rat anatomy with nuclear magnetic resonance. Radiology 1980; 136: 695-700. (Pubitemid 10049104)
-
(1980)
Radiology
, vol.136
, Issue.3
, pp. 695-700
-
-
Hansen, G.1
Crooks, L.E.2
Davis, P.3
-
6
-
-
0036669846
-
MR microscopy and high resolution small animal MRI: Applications in neuroscience research
-
DOI 10.1016/S0301-0082(02)00020-5, PII S0301008202000205
-
Benveniste H, Blackband S,. MR microscopy and high resolution small animal MRI: applications in neuroscience research. Prog Neurobiol 2002; 67: 393-420. (Pubitemid 35257912)
-
(2002)
Progress in Neurobiology
, vol.67
, Issue.5
, pp. 393-420
-
-
Benveniste, H.1
Blackband, S.2
-
7
-
-
0022526725
-
Nuclear magnetic resonance imaging of a single cell
-
Aguayo JB, Blackband SJ, Schoeniger J, Mattingly MA, Hintermann M,. Nuclear magnetic resonance imaging of a single cell. Nature 1986; 322: 190-191. (Pubitemid 16005461)
-
(1986)
Nature
, vol.322
, Issue.6075
, pp. 190-191
-
-
Aguayo, J.B.1
Blackband, S.J.2
Schoeniger, J.3
-
8
-
-
0001212368
-
High-resolution imaging: The NMR microscope
-
Eccles CD, Callaghan PT,. High-resolution imaging: the NMR microscope. J Magn Reson 1986; 68: 393-398.
-
(1986)
J Magn Reson
, vol.68
, pp. 393-398
-
-
Eccles, C.D.1
Callaghan, P.T.2
-
9
-
-
0001305395
-
Nuclear magnetic resonance imaging at microscopic resolution
-
Johnson GA, Thompson MB, Gewalt SL, Hayes CE,. Nuclear magnetic resonance imaging at microscopic resolution. J Magn Reson 1986; 68: 129-137.
-
(1986)
J Magn Reson
, vol.68
, pp. 129-137
-
-
Johnson, G.A.1
Thompson, M.B.2
Gewalt, S.L.3
Hayes, C.E.4
-
10
-
-
0027572255
-
Histology by magnetic resonance microscopy
-
Johnson GA, Benveniste H, Black RD, Hedlund LW, Maronpot RR, Smith BR,. Histology by magnetic resonance microscopy. Magn Reson Q 1993; 9: 1-30.
-
(1993)
Magn Reson Q
, vol.9
, pp. 1-30
-
-
Johnson, G.A.1
Benveniste, H.2
Black, R.D.3
Hedlund, L.W.4
Maronpot, R.R.5
Smith, B.R.6
-
11
-
-
0026635543
-
Three-dimensional NMR microscopy: Improving SNR with temperature and microcoils
-
McFarland EW, Mortara A,. Three-dimensional NMR microscopy: improving SNR with temperature and microcoils. Magn Reson Imaging 1992; 10: 279-288.
-
(1992)
Magn Reson Imaging
, vol.10
, pp. 279-288
-
-
McFarland, E.W.1
Mortara, A.2
-
12
-
-
0027980240
-
NMR microspectroscopy using 100 microns planar RF coils fabricated on gallium arsenide substrates
-
Peck TL, Magin RL, Kruse J, Feng M,. NMR microspectroscopy using 100 microns planar RF coils fabricated on gallium arsenide substrates. IEEE Trans Biomed Eng 1994; 41: 706-709.
-
(1994)
IEEE Trans Biomed Eng
, vol.41
, pp. 706-709
-
-
Peck, T.L.1
Magin, R.L.2
Kruse, J.3
Feng, M.4
-
13
-
-
0029355413
-
Design and analysis of microcoils for NMR microscopy
-
Peck TL, Magin RL, Lauterbur PC,. Design and analysis of microcoils for NMR microscopy. J Magn Reson B 1995; 108: 114-124.
-
(1995)
J Magn Reson B
, vol.108
, pp. 114-124
-
-
Peck, T.L.1
Magin, R.L.2
Lauterbur, P.C.3
-
14
-
-
0029154873
-
On-line NMR detection of amino acids and peptides in microbore LC
-
Wu N, Webb A, Peck TL, Sweedler JV,. On-line NMR detection of amino acids and peptides in microbore LC. Anal Chem 1995; 67: 3101-3107.
-
(1995)
Anal Chem
, vol.67
, pp. 3101-3107
-
-
Wu, N.1
Webb, A.2
Peck, T.L.3
Sweedler, J.V.4
-
15
-
-
79959575876
-
-
High-field MRI of single histological slices using an inductively coupled, self-resonant microcoil: application to ex vivo samples of patients with Alzheimer's disease
-
Nabuurs RJA, Hegeman I, Natté R, van Duinen SG, van Buchem MA, van der Weerd L, Webb AG,. High-field MRI of single histological slices using an inductively coupled, self-resonant microcoil: application to ex vivo samples of patients with Alzheimer's disease. NMR Biomed 2011; 24: 351-357.
-
(2011)
NMR Biomed
, vol.24
, pp. 351-357
-
-
Nabuurs, R.J.A.1
Hegeman, I.2
Natté, R.3
Van Duinen, S.G.4
Van Buchem, M.A.5
Van Der Weerd, L.6
Webb, A.G.7
-
17
-
-
0036435755
-
3D MR microscopy with resolution 3.7 microm by 3.3 microm by 3.3 microm
-
Ciobanu L, Seeber DA, Pennington CH,. 3D MR microscopy with resolution 3.7 microm by 3.3 microm by 3.3 microm. J Magn Reson 2002; 158: 178-182.
-
(2002)
J Magn Reson
, vol.158
, pp. 178-182
-
-
Ciobanu, L.1
Seeber, D.A.2
Pennington, C.H.3
-
18
-
-
0035742358
-
One micrometer resolution NMR microscopy
-
Lee SC, Kim K, Kim J, Lee S, Han Yi J, Kim SW, Ha KS, Cheong C,. One micrometer resolution NMR microscopy. J Magn Reson 2001; 150: 207-213.
-
(2001)
J Magn Reson
, vol.150
, pp. 207-213
-
-
Lee, S.C.1
Kim, K.2
Kim, J.3
Lee, S.4
Han Yi, J.5
Kim, S.W.6
Ha, K.S.7
Cheong, C.8
-
19
-
-
67349119508
-
Magnetic resonance microscopy of mammalian neurons
-
Flint JJ, Lee CH, Hansen B, Fey M, Schmidig D, Bui JD, King MA, Vestergaard-Poulsen P, Blackband SJ,. Magnetic resonance microscopy of mammalian neurons. Neuroimage 2009; 46: 1037-1040.
-
(2009)
Neuroimage
, vol.46
, pp. 1037-1040
-
-
Flint, J.J.1
Lee, C.H.2
Hansen, B.3
Fey, M.4
Schmidig, D.5
Bui, J.D.6
King, M.A.7
Vestergaard-Poulsen, P.8
Blackband, S.J.9
-
20
-
-
67049107831
-
MR microscopy of micron scale structures
-
Lee SC, Kim K, Kim J, Yi JH, Lee S, Cheong C,. MR microscopy of micron scale structures. Magn Reson Imaging 2009; 27: 828-833.
-
(2009)
Magn Reson Imaging
, vol.27
, pp. 828-833
-
-
Lee, S.C.1
Kim, K.2
Kim, J.3
Yi, J.H.4
Lee, S.5
Cheong, C.6
-
21
-
-
54949104373
-
-
NMR microscopy with isotropic resolution of 3.0 μm using dedicated hardware and optimized methods
-
Weiger M, Schmidig D, Denoth S, Massin C, Vincent F, Schenkel M, Fey M,. NMR microscopy with isotropic resolution of 3.0 μm using dedicated hardware and optimized methods. Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering 2008; 33B: 84-93.
-
(2008)
Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering
, vol.33 B
, pp. 84-93
-
-
Weiger, M.1
Schmidig, D.2
Denoth, S.3
Massin, C.4
Vincent, F.5
Schenkel, M.6
Fey, M.7
-
22
-
-
77649110041
-
In vivo high-resolution magnetic resonance skin imaging at 1.5 T and 3 T
-
Barral JK, Bangerter NK, Hu BS, Nishimura DG,. In vivo high-resolution magnetic resonance skin imaging at 1.5 T and 3 T. Magn Reson Med 2010; 63: 790-796.
-
(2010)
Magn Reson Med
, vol.63
, pp. 790-796
-
-
Barral, J.K.1
Bangerter, N.K.2
Hu, B.S.3
Nishimura, D.G.4
-
23
-
-
33751356547
-
Advances in MR imaging of the skin
-
DOI 10.1002/nbm.1101
-
Bittoun J, Querleux B, Darrasse L,. Advances in MR imaging of the skin. NMR Biomed 2006; 19: 723-730. (Pubitemid 44811540)
-
(2006)
NMR in Biomedicine
, vol.19
, Issue.7
, pp. 723-730
-
-
Bittoun, J.1
Querleux, B.2
Darrasse, L.3
-
24
-
-
0025286847
-
In vivo high-resolution MR imaging of the skin in a whole-body system at 1.5 T
-
Bittoun J, Saint-Jalmes H, Querleux BG, Darrasse L, Jolivet O, Idy-Peretti I, Wartski M, Richard SB, Leveque JL,. In vivo high-resolution MR imaging of the skin in a whole-body system at 1.5 T. Radiology 1990; 176: 457-460. (Pubitemid 20225136)
-
(1990)
Radiology
, vol.176
, Issue.2
, pp. 457-460
-
-
Bittoun, J.1
Saint-Jalmes, H.2
Querleux, B.G.3
Darrasse, L.4
Jolivet, O.5
Idy-Peretti, I.6
Wartski, M.7
Richard, S.B.8
Leveque, J.-L.9
-
25
-
-
79958266219
-
-
Magnetic resonance microimaging of human skin vasculature in vivo at 3 Tesla
-
Laistler E, Loewe R, Moser E,. Magnetic resonance microimaging of human skin vasculature in vivo at 3 Tesla. Magnetic Resonance in Medicine 2011; 65: 1718-1723.
-
(2011)
Magnetic Resonance in Medicine
, vol.65
, pp. 1718-1723
-
-
Laistler, E.1
Loewe, R.2
Moser, E.3
-
26
-
-
0028799813
-
Role of high-resolution magnetic resonance imaging for differentiating melanin-containing skin tumors
-
Maurer J, Knollmann FD, Schlums D, Garbe C, Vogl TJ, Bier J, Felix R,. Role of high-resolution magnetic resonance imaging for differentiating melanin-containing skin tumors. Invest Radiol 1995; 30: 638-643.
-
(1995)
Invest Radiol
, vol.30
, pp. 638-643
-
-
Maurer, J.1
Knollmann, F.D.2
Schlums, D.3
Garbe, C.4
Vogl, T.J.5
Bier, J.6
Felix, R.7
-
27
-
-
0025759073
-
In vivo proton relaxation times analysis of the skin layers by magnetic resonance imaging
-
Richard S, Querleux B, Bittoun J, Idy-Peretti I, Jolivet O, Cermakova E, Leveque JL,. In vivo proton relaxation times analysis of the skin layers by magnetic resonance imaging. J Invest Dermatol 1991; 97: 120-125.
-
(1991)
J Invest Dermatol
, vol.97
, pp. 120-125
-
-
Richard, S.1
Querleux, B.2
Bittoun, J.3
Idy-Peretti, I.4
Jolivet, O.5
Cermakova, E.6
Leveque, J.L.7
-
28
-
-
0007487099
-
In vivo MR microscopy of the human skin
-
DOI 10.1002/mrm.1910370207
-
Song HK, Wehrli FW, Ma J,. In vivo MR microscopy of the human skin. Magn Reson Med 1997; 37: 185-191. (Pubitemid 27045389)
-
(1997)
Magnetic Resonance in Medicine
, vol.37
, Issue.2
, pp. 185-191
-
-
Song, H.K.1
Wehrli, F.W.2
Ma, J.3
-
29
-
-
3342973064
-
Comparison of high-resolution MRI, optical microscopy and SEM for quantitation of trabecular architecture in the rat femur
-
DOI 10.1016/j.mri.2004.02.008, PII S0730725X04001249
-
Hopper TA, Meder R, Pope JM,. Comparison of high-resolution MRI, optical microscopy and SEM for quantitation of trabecular architecture in the rat femur. Magn Reson Imaging 2004; 22: 953-961. (Pubitemid 38993525)
-
(2004)
Magnetic Resonance Imaging
, vol.22
, Issue.7
, pp. 953-961
-
-
Hopper, T.A.J.1
Meder, R.2
Pope, J.M.3
-
30
-
-
33750942521
-
Observation of anomalous diffusion in excised tissue by characterizing the diffusion-time dependence of the MR signal
-
DOI 10.1016/j.jmr.2006.08.009, PII S1090780706002527
-
Ozarslan E, Basser PJ, Shepherd TM, Thelwall PE, Vemuri BC, Blackband SJ,. Observation of anomalous diffusion in excised tissue by characterizing the diffusion-time dependence of the MR signal. J Magn Reson 2006; 183: 315-323. (Pubitemid 44739339)
-
(2006)
Journal of Magnetic Resonance
, vol.183
, Issue.2
, pp. 315-323
-
-
Ozarslan, E.1
Basser, P.J.2
Shepherd, T.M.3
Thelwall, P.E.4
Vemuri, B.C.5
Blackband, S.J.6
-
31
-
-
0036708142
-
Simultaneous diffusion MRI measurements from multiple perfused rat hippocampal slices
-
DOI 10.1002/mrm.10241
-
Shepherd TM, Blackband SJ, Wirth ED, III,. Simultaneous diffusion MRI measurements from multiple perfused rat hippocampal slices. Magn Reson Med 2002; 48: 565-569. (Pubitemid 34951340)
-
(2002)
Magnetic Resonance in Medicine
, vol.48
, Issue.3
, pp. 565-569
-
-
Shepherd, T.M.1
Blackband, S.J.2
Wirth III, E.D.3
-
32
-
-
33645731533
-
MR microscopy of rat hippocampal slice cultures: A novel model for studying cellular processes and chronic perturbations to tissue microstructure
-
Shepherd TM, Scheffler B, King MA, Stanisz GJ, Steindler DA, Blackband SJ,. MR microscopy of rat hippocampal slice cultures: a novel model for studying cellular processes and chronic perturbations to tissue microstructure. Neuroimage 2006; 30: 780-786.
-
(2006)
Neuroimage
, vol.30
, pp. 780-786
-
-
Shepherd, T.M.1
Scheffler, B.2
King, M.A.3
Stanisz, G.J.4
Steindler, D.A.5
Blackband, S.J.6
-
33
-
-
0346881341
-
Diffusion Magnetic Resonance Imaging Study of a Rat Hippocampal Slice Model for Acute Brain Injury
-
Shepherd TM, Thelwall PE, Blackband SJ, Pike BR, Hayes RL, Wirth ED, 3rd,. Diffusion magnetic resonance imaging study of a rat hippocampal slice model for acute brain injury. J Cereb Blood Flow Metab 2003; 23: 1461-1470. (Pubitemid 38018265)
-
(2003)
Journal of Cerebral Blood Flow and Metabolism
, vol.23
, Issue.12
, pp. 1461-1470
-
-
Shepherd, T.M.1
Thelwall, P.E.2
Blackband, S.J.3
Pike, B.R.4
Hayes, R.L.5
Wirth III, E.D.6
-
34
-
-
0037406523
-
Water diffusion measurements in perfused human hippocampal slices undergoing tonicity changes
-
DOI 10.1002/mrm.10456
-
Shepherd TM, Wirth ED, III, Thelwall PE, Chen HX, Roper SN, Blackband SJ,. Water diffusion measurements in perfused human hippocampal slices undergoing tonicity changes. Magn Reson Med 2003; 49: 856-863. (Pubitemid 36523472)
-
(2003)
Magnetic Resonance in Medicine
, vol.49
, Issue.5
, pp. 856-863
-
-
Shepherd, T.M.1
Wirth III, E.D.2
Thelwall, P.E.3
Chen, H.-X.4
Roper, S.N.5
Blackband, S.J.6
-
36
-
-
21244482534
-
Parallel imaging for NMR microscopy at 14.1 Tesla
-
DOI 10.1002/mrm.20531
-
Sutton BP, Ciobanu L, Zhang X, Webb A,. Parallel imaging for NMR microscopy at 14.1 Tesla. Magn Reson Med 2005; 54: 9-13. (Pubitemid 40898390)
-
(2005)
Magnetic Resonance in Medicine
, vol.54
, Issue.1
, pp. 9-13
-
-
Sutton, B.P.1
Ciobanu, L.2
Zhang, X.3
Webb, A.4
-
37
-
-
40449084737
-
Ultra-fast and accurate assessment of cardiac function in rats using accelerated MRI at 9.4 Tesla
-
DOI 10.1002/mrm.21491
-
Schneider JE, Lanz T, Barnes H, Medway D, Stork LA, Lygate CA, Smart S, Griswold MA, Neubauer S,. Ultra-fast and accurate assessment of cardiac function in rats using accelerated MRI at 9.4 Tesla. Magn Reson Med 2008; 59: 636-641. (Pubitemid 351348236)
-
(2008)
Magnetic Resonance in Medicine
, vol.59
, Issue.3
, pp. 636-641
-
-
Schneider, J.E.1
Lanz, T.2
Barnes, H.3
Medway, D.4
Stork, L.-A.5
Lygate, C.A.6
Smart, S.7
Griswold, M.A.8
Neubauer, S.9
-
38
-
-
34249656209
-
-
Mouse MRI using phased-array coils
-
Gareis D, Wichmann T, Lanz T, Melkus G, Horn M, Jakob PM,. Mouse MRI using phased-array coils. NMR in Biomedicine 2007; 20: 326-334.
-
(2007)
NMR in Biomedicine
, vol.20
, pp. 326-334
-
-
Gareis, D.1
Wichmann, T.2
Lanz, T.3
Melkus, G.4
Horn, M.5
Jakob, P.M.6
-
39
-
-
79960594280
-
A 20-channel receive-only mouse array coil for a 3 T clinical MRI system
-
Keil B, Wiggins GC, Triantafyllou C, Wald LL, Meise FM, Schreiber LM, Klose KJ, Heverhagen JT,. A 20-channel receive-only mouse array coil for a 3 T clinical MRI system. Magn Reson Med 2011; 66: 584-595.
-
(2011)
Magn Reson Med
, vol.66
, pp. 584-595
-
-
Keil, B.1
Wiggins, G.C.2
Triantafyllou, C.3
Wald, L.L.4
Meise, F.M.5
Schreiber, L.M.6
Klose, K.J.7
Heverhagen, J.T.8
-
41
-
-
84865520411
-
A 20 coil array system for parallel imaging-accelerated multiple mouse MRI
-
Montreal. p
-
Ramirez MS, Chen Y, Lai SY, Bankson JA,. A 20 coil array system for parallel imaging-accelerated multiple mouse MRI. In: Proc. of the annual meeting of the International Society of Magnetic Resonance in Medicine (ISMRM), 2011, Montreal. p 1820.
-
(2011)
Proc. of the Annual Meeting of the International Society of Magnetic Resonance in Medicine (ISMRM)
, pp. 1820
-
-
Ramirez, M.S.1
Chen, Y.2
Lai, S.Y.3
Bankson, J.A.4
-
42
-
-
17144399252
-
Parallel imaging: System design and limitations
-
2004 2nd IEEE International Symposium on Biomedical Imaging: Macro to Nano
-
Wright SM, McDougall MP, Kurpad K, Brown DG,. Parallel imaging: system design and limitations. In: 2004 2nd IEEE International Symposium on Biomedical Imaging: Macro to Nano (IEEE Cat No. 04EX821), Arlington, VA, 2004. pp 1200-1203. (Pubitemid 40514158)
-
(2004)
2004 2nd IEEE International Symposium on Biomedical Imaging: Macro to Nano
, vol.2
, pp. 1200-1203
-
-
Wright, S.M.1
McDougall, M.P.2
Kurpad, K.3
Brown, D.G.4
-
43
-
-
22744435455
-
64-Channel array coil for single echo acquisition magnetic resonance imaging
-
DOI 10.1002/mrm.20568
-
McDougall MP, Wright SM,. 64-Channel array coil for single echo acquisition magnetic resonance imaging. Magn Reson Med 2005; 54: 386-392. (Pubitemid 41033555)
-
(2005)
Magnetic Resonance in Medicine
, vol.54
, Issue.2
, pp. 386-392
-
-
McDougall, M.P.1
Wright, S.M.2
-
44
-
-
84865509144
-
Simple digital tuning system for large arrays of coils
-
Toronto, p
-
Feng K, McDougall MP, Wright SM,. Simple digital tuning system for large arrays of coils. In: Int Soc Magn Reson Med, Toronto, 2007. p. 1050.
-
(2007)
Int Soc Magn Reson Med
, pp. 1050
-
-
Feng, K.1
McDougall, M.P.2
Wright, S.M.3
-
45
-
-
0024513186
-
-
Magnetic resonance imaging using a ribbonator: hand and wrist
-
Marshall EA, Listinsky JJ, Ceckler TL, Szumowski J, Bryant RG, Hornak JP,. Magnetic resonance imaging using a ribbonator: hand and wrist. Magnetic Resonance in Medicine 1989; 9: 369-378.
-
(1989)
Magnetic Resonance in Medicine
, vol.9
, pp. 369-378
-
-
Marshall, E.A.1
Listinsky, J.J.2
Ceckler, T.L.3
Szumowski, J.4
Bryant, R.G.5
Hornak, J.P.6
-
46
-
-
0025226022
-
The NMR phased array
-
Roemer PB, Edelstein WA, Hayes CE, Souza SP, Mueller OM,. The NMR phased array. Magn Reson Med 1990; 16: 192-225.
-
(1990)
Magn Reson Med
, vol.16
, pp. 192-225
-
-
Roemer, P.B.1
Edelstein, W.A.2
Hayes, C.E.3
Souza, S.P.4
Mueller, O.M.5
-
48
-
-
34249871358
-
Investigation of coil phase compensation in 3D imaging at very high acceleration factors
-
DOI 10.1002/jmri.20938
-
McDougall MP, Wright SM,. Investigation of coil phase compensation in 3D imaging at very high acceleration factors. J Magn Reson Imaging 2007; 25: 1305-1311. (Pubitemid 46870292)
-
(2007)
Journal of Magnetic Resonance Imaging
, vol.25
, Issue.6
, pp. 1305-1311
-
-
McDougall, M.P.1
Wright, S.M.2
-
49
-
-
0033772492
-
Partially parallel imaging with localized sensitivities (PILS)
-
Griswold MA, Jakob PM, Nittka M, Goldfarb JW, Haase A,. Partially parallel imaging with localized sensitivities (PILS). Magn Reson Med 2000; 44: 602-609.
-
(2000)
Magn Reson Med
, vol.44
, pp. 602-609
-
-
Griswold, M.A.1
Jakob, P.M.2
Nittka, M.3
Goldfarb, J.W.4
Haase, A.5
|