메뉴 건너뛰기




Volumn 33, Issue 2, 2008, Pages 84-93

NMR microscopy with isotropic resolution of 3.0 μm using dedicated hardware and optimized methods

Author keywords

Constant time imaging; Diffusion; NMR microscopy; Planar gradients; RF microcoil; Spatial resolution

Indexed keywords


EID: 54949104373     PISSN: 15525031     EISSN: 1552504X     Source Type: Journal    
DOI: 10.1002/cmr.b.20112     Document Type: Article
Times cited : (57)

References (39)
  • 1
    • 0028393459 scopus 로고
    • Relaxation-time and diffusion NMR microscopy of single neurons
    • Schoeniger JS, Aiken N, Hsu E, Blackband SJ. 1994. Relaxation-time and diffusion NMR microscopy of single neurons. J Magn Reson B 103:261-273.
    • (1994) J Magn Reson B , vol.103 , pp. 261-273
    • Schoeniger, J.S.1    Aiken, N.2    Hsu, E.3    Blackband, S.J.4
  • 4
    • 0036801687 scopus 로고    scopus 로고
    • Limits to magnetic resonance microscopy
    • Glover P, Mansfield P. 2002. Limits to magnetic resonance microscopy. Rep Prog Phys 65:1489-1511.
    • (2002) Rep Prog Phys , vol.65 , pp. 1489-1511
    • Glover, P.1    Mansfield, P.2
  • 6
    • 0000178929 scopus 로고
    • Sensitivity and resolution in NMR imaging
    • Callaghan PT, Eccles CD. 1987. Sensitivity and resolution in NMR imaging. J Magn Reson 71:426-445.
    • (1987) J Magn Reson , vol.71 , pp. 426-445
    • Callaghan, P.T.1    Eccles, C.D.2
  • 8
    • 0026635543 scopus 로고
    • Three-dimensional NMR microscopy: Improving SNR with temperature and microcoils
    • McFarland EW, Mortara A. 1992. Three-dimensional NMR microscopy: improving SNR with temperature and microcoils. Magn Reson Imag 10:279-288.
    • (1992) Magn Reson Imag , vol.10 , pp. 279-288
    • McFarland, E.W.1    Mortara, A.2
  • 9
    • 0028455272 scopus 로고
    • The design and construction of a NMR microscopy probe
    • Schoeniger JS, Blackband SJ. 1992. The design and construction of a NMR microscopy probe. J Magn Reson B 104:127-134.
    • (1992) J Magn Reson B , vol.104 , pp. 127-134
    • Schoeniger, J.S.1    Blackband, S.J.2
  • 10
    • 0028221835 scopus 로고
    • A microscope slide probe for high resolution imaging at 11.7 tesla
    • Glover PM, Bowtell RW, Brown GD, Mansfield P. 1994. A microscope slide probe for high resolution imaging at 11.7 tesla. Magn Reson Med 31:423-428.
    • (1994) Magn Reson Med , vol.31 , pp. 423-428
    • Glover, P.M.1    Bowtell, R.W.2    Brown, G.D.3    Mansfield, P.4
  • 11
    • 0029355413 scopus 로고
    • Design and analysis of microcoils for NMR microscopy
    • Peck TL, Magin RL, Lauterbur PC. 1995. Design and analysis of microcoils for NMR microscopy. J Magn Reson B 108:114-124.
    • (1995) J Magn Reson B , vol.108 , pp. 114-124
    • Peck, T.L.1    Magin, R.L.2    Lauterbur, P.C.3
  • 12
    • 0035582655 scopus 로고    scopus 로고
    • Solenoidal microcoil design. I. Optimizing RF homogeneity and coil dimensions
    • Minard KR, Wind RA. 2001. Solenoidal microcoil design. I. Optimizing RF homogeneity and coil dimensions. Concepts Magn Reson 13:128-142.
    • (2001) Concepts Magn Reson , vol.13 , pp. 128-142
    • Minard, K.R.1    Wind, R.A.2
  • 13
    • 0035630560 scopus 로고    scopus 로고
    • Solenoidal microcoil design. II. Optimizing winding parameters for maximum signal-to-noise performance
    • Minard KR, Wind RA. 2001. Solenoidal microcoil design. II. Optimizing winding parameters for maximum signal-to-noise performance. Concepts Magn Reson 13:190-210
    • (2001) Concepts Magn Reson , vol.13 , pp. 190-210
    • Minard, K.R.1    Wind, R.A.2
  • 15
    • 0011525098 scopus 로고
    • Diffusion-limited resolution in nuclear magnetic resonance microscopy
    • Callaghan PT, Eccles CD. 1988. Diffusion-limited resolution in nuclear magnetic resonance microscopy. J Magn Reson 78:1-8.
    • (1988) J Magn Reson , vol.78 , pp. 1-8
    • Callaghan, P.T.1    Eccles, C.D.2
  • 16
    • 0024504169 scopus 로고
    • A generalized formulation of diffusion effects in mm resolution nuclear magnetic resonance imaging
    • Ahn CB, Cho ZH. 1989. A generalized formulation of diffusion effects in mm resolution nuclear magnetic resonance imaging. Med Phys 16:22-28.
    • (1989) Med Phys , vol.16 , pp. 22-28
    • Ahn, C.B.1    Cho, Z.H.2
  • 17
  • 19
    • 0039795635 scopus 로고
    • Correlated susceptibility and diffusion effects in NMR microscopy using both phase-frequency encoding and phase-phase encoding
    • Callaghan PT, Forde LC, Rofe CJ. 1994. Correlated susceptibility and diffusion effects in NMR microscopy using both phase-frequency encoding and phase-phase encoding. J Magn Reson B 104:34-53.
    • (1994) J Magn Reson B , vol.104 , pp. 34-53
    • Callaghan, P.T.1    Forde, L.C.2    Rofe, C.J.3
  • 20
    • 0002312260 scopus 로고
    • Sensitivity and resolution of constant-time imaging
    • Gravina S, Cory DG. 1994. Sensitivity and resolution of constant-time imaging. J Magn Reson B 104:53-61.
    • (1994) J Magn Reson B , vol.104 , pp. 53-61
    • Gravina, S.1    Cory, D.G.2
  • 22
    • 0023812470 scopus 로고
    • Nuclear magnetic resonance microscopy with 4-mm resolution: Theoretical study and experimental results
    • Cho ZH, Ahn CB, Juh SC, Lee HK, Jacobs RE, Lee S, Yi JH, Jo JM. 1988. Nuclear magnetic resonance microscopy with 4-mm resolution: theoretical study and experimental results. Med Phys 15:815-824.
    • (1988) Med Phys , vol.15 , pp. 815-824
    • Cho, Z.H.1    Ahn, C.B.2    Juh, S.C.3    Lee, H.K.4    Jacobs, R.E.5    Lee, S.6    Yi, J.H.7    Jo, J.M.8
  • 24
    • 0036435755 scopus 로고    scopus 로고
    • 3D MR microscopy with resolution 3.7 μm by 3.3 μm by 3.3 μm
    • Ciobanu L, Seeber DA, Pennington CH. 2002. 3D MR microscopy with resolution 3.7 μm by 3.3 μm by 3.3 μm. J Magn Reson 158:178-182.
    • (2002) J Magn Reson , vol.158 , pp. 178-182
    • Ciobanu, L.1    Seeber, D.A.2    Pennington, C.H.3
  • 25
    • 44949291663 scopus 로고
    • A method for imaging nuclei with short T2 relaxation and its application to boron-11 NMR imaging of a BNCT agent in an intact rat
    • Bendel P, Davis M, Berman E, Kabalka GW. 1990. A method for imaging nuclei with short T2 relaxation and its application to boron-11 NMR imaging of a BNCT agent in an intact rat. J Magn Reson 88:369-375.
    • (1990) J Magn Reson , vol.88 , pp. 369-375
    • Bendel, P.1    Davis, M.2    Berman, E.3    Kabalka, G.W.4
  • 26
    • 0026724894 scopus 로고
    • Time-independent point-spread function for NMR microscopy
    • McFarland EW. 1992. Time-independent point-spread function for NMR microscopy. Magn Reson Imag 10:269-278.
    • (1992) Magn Reson Imag , vol.10 , pp. 269-278
    • McFarland, E.W.1
  • 27
    • 18444365887 scopus 로고    scopus 로고
    • Optimising the point spread function in phase-encoded magnetic resonance microscopy
    • Webb AG. 2004. Optimising the point spread function in phase-encoded magnetic resonance microscopy. Concepts Magn Reson A 22:25-36.
    • (2004) Concepts Magn Reson A , vol.22 , pp. 25-36
    • Webb, A.G.1
  • 28
    • 36149003638 scopus 로고
    • Bloch equations with diffusion terms
    • Torrey HC. 1956. Bloch equations with diffusion terms. Phys Rev 104:563-565.
    • (1956) Phys Rev , vol.104 , pp. 563-565
    • Torrey, H.C.1
  • 29
    • 36849118375 scopus 로고
    • Electrical current shims for correcting magnetic fields
    • Anderson WA. 1961. Electrical current shims for correcting magnetic fields. Rev Sci Instr 32:241-250.
    • (1961) Rev Sci Instr , vol.32 , pp. 241-250
    • Anderson, W.A.1
  • 31
    • 0001166277 scopus 로고
    • Effects of restricted diffusion on microscopic NMR imaging
    • Hyslop WB, Lauterbur PC. 1991. Effects of restricted diffusion on microscopic NMR imaging. J Magn Reson 94:501-510.
    • (1991) J Magn Reson , vol.94 , pp. 501-510
    • Hyslop, W.B.1    Lauterbur, P.C.2
  • 32
    • 30244535047 scopus 로고
    • Edge enhancement by diffusion in microscopic magnetic resonance imaging
    • Pütz B, Barsky D, Schulten K. 1992. Edge enhancement by diffusion in microscopic magnetic resonance imaging. J Magn Reson 97:27-53.
    • (1992) J Magn Reson , vol.97 , pp. 27-53
    • Pütz, B.1    Barsky, D.2    Schulten, K.3
  • 33
    • 43949173750 scopus 로고
    • Diffusive relaxation and edge enhancement in NMR Microscopy
    • Callaghan PT, Coy A, Forde LC, Rofe CJ. 1993. Diffusive relaxation and edge enhancement in NMR Microscopy. J Magn Reson A 101:347-350.
    • (1993) J Magn Reson A , vol.101 , pp. 347-350
    • Callaghan, P.T.1    Coy, A.2    Forde, L.C.3    Rofe, C.J.4
  • 34
    • 58149364485 scopus 로고
    • Diffusive edge enhancement in imaging
    • DeSwiet TM. 1995. Diffusive edge enhancement in imaging. J Magn Reson B 109:12-18.
    • (1995) J Magn Reson B , vol.109 , pp. 12-18
    • DeSwiet, T.M.1
  • 35
    • 35949039106 scopus 로고
    • Importance of classical diffusion in NMR studies of water in biological cells
    • Brownstein KR, Tarr CE. 1979. Importance of classical diffusion in NMR studies of water in biological cells. Phys Rev 19:2446-2453.
    • (1979) Phys Rev , vol.19 , pp. 2446-2453
    • Brownstein, K.R.1    Tarr, C.E.2
  • 37
    • 4544341068 scopus 로고    scopus 로고
    • Prospects for diffusion enhancement of signal and resolution in magnetic resonance microscopy
    • Pennington CH. 2003. Prospects for diffusion enhancement of signal and resolution in magnetic resonance microscopy. Concepts Magn Reson A 19:71-79.
    • (2003) Concepts Magn Reson A , vol.19 , pp. 71-79
    • Pennington, C.H.1
  • 38
    • 4544368188 scopus 로고    scopus 로고
    • Signal enhancement by diffusion: Experimental observation of the "DESIRE" effect
    • Ciobanu L, Webb AG, Pennington CH. 2004. Signal enhancement by diffusion: experimental observation of the "DESIRE" effect. J Magn Reson 170:252-256.
    • (2004) J Magn Reson , vol.170 , pp. 252-256
    • Ciobanu, L.1    Webb, A.G.2    Pennington, C.H.3
  • 39
    • 36849006451 scopus 로고    scopus 로고
    • A closer look into DESIRE for NMR microscopy
    • Weiger M, Zeng Y, Fey M. 2008. A closer look into DESIRE for NMR microscopy. J Magn Reson 190:95-104.
    • (2008) J Magn Reson , vol.190 , pp. 95-104
    • Weiger, M.1    Zeng, Y.2    Fey, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.