메뉴 건너뛰기




Volumn 43, Issue 10, 2012, Pages 1764-1770

Bone properties affect loosening of half-pin external fixators at the pin-bone interface

Author keywords

Ageing; Finite element analysis; Fracture fixation; Implant material; Orthotropy

Indexed keywords

TITANIUM;

EID: 84865472331     PISSN: 00201383     EISSN: 18790267     Source Type: Journal    
DOI: 10.1016/j.injury.2012.07.001     Document Type: Article
Times cited : (49)

References (40)
  • 1
    • 0023679936 scopus 로고
    • Mechanical performance of standard Orthofix external fixator
    • E.Y.S. Chao, and T.J. Hein Mechanical performance of standard Orthofix external fixator Orthopedics 11 1988 1057 1069
    • (1988) Orthopedics , vol.11 , pp. 1057-1069
    • Chao, E.Y.S.1    Hein, T.J.2
  • 3
    • 0027435284 scopus 로고
    • Cortical bone reactions at the interface of external fixation half-pins under different loading conditions
    • H.T. Aro, M.D. Markel, and E.Y.S. Chao Cortical bone reactions at the interface of external fixation half-pins under different loading conditions The Journal of Trauma 35 1993 776 785
    • (1993) The Journal of Trauma , vol.35 , pp. 776-785
    • Aro, H.T.1    Markel, M.D.2    Chao, E.Y.S.3
  • 5
    • 0029135259 scopus 로고
    • Thermal response and torque resistance of five cortical half-pins under simulated insertion technique
    • M.A. Wikenheiser, M.D. Markel, D.G. Lewallen, and E.Y.S. Chao Thermal response and torque resistance of five cortical half-pins under simulated insertion technique Journal of Orthopaedic Research 13 1995 615 619
    • (1995) Journal of Orthopaedic Research , vol.13 , pp. 615-619
    • Wikenheiser, M.A.1    Markel, M.D.2    Lewallen, D.G.3    Chao, E.Y.S.4
  • 7
    • 0022387481 scopus 로고
    • Parametric analyses of pin-bone stresses in external fracture fixation devices
    • R. Huiskes, E.Y.S. Chao, and T.E. Crippen Parametric analyses of pin-bone stresses in external fracture fixation devices Journal of Orthopaedic Research 3 1985 341 349
    • (1985) Journal of Orthopaedic Research , vol.3 , pp. 341-349
    • Huiskes, R.1    Chao, E.Y.S.2    Crippen, T.E.3
  • 8
    • 0023185850 scopus 로고
    • Complications of external fixation of open fractures of the tibia
    • R.P. Clifford, T.J. Lyons, and J.K. Webb Complications of external fixation of open fractures of the tibia Injury 18 1987 174 176
    • (1987) Injury , vol.18 , pp. 174-176
    • Clifford, R.P.1    Lyons, T.J.2    Webb, J.K.3
  • 10
    • 0018331354 scopus 로고    scopus 로고
    • Changes in the impact energy absorption of bone with age
    • J.D. Currey Changes in the impact energy absorption of bone with age Journal of Biomechanics 12 1997 459 469
    • (1997) Journal of Biomechanics , vol.12 , pp. 459-469
    • Currey, J.D.1
  • 14
    • 0020364649 scopus 로고
    • Rigidity and stress analyses of external fracture fixation devices - A theoretical approach
    • E.Y.S. Chao, R.A. Kasman, and K.N. An Rigidity and stress analyses of external fracture fixation devices - a theoretical approach Journal of Biomechanics 15 1982 971 983
    • (1982) Journal of Biomechanics , vol.15 , pp. 971-983
    • Chao, E.Y.S.1    Kasman, R.A.2    An, K.N.3
  • 15
    • 0022579452 scopus 로고
    • Guidelines for external fixation frame rigidity and stresses
    • R. Huiskes, and E.Y.S. Chao Guidelines for external fixation frame rigidity and stresses Journal of Orthopaedic Research 4 1986 68 75
    • (1986) Journal of Orthopaedic Research , vol.4 , pp. 68-75
    • Huiskes, R.1    Chao, E.Y.S.2
  • 16
    • 0026927643 scopus 로고
    • Biomechanical consequences of callus development in Hoffmann, Wagner, orthofix and Ilizarov external fixators
    • J.A. Juan, J. Prat, P. Vera, J.V. Hoyos, J. Sanchez-Lacuesta, and J.L. Peris Biomechanical consequences of callus development in Hoffmann, Wagner, orthofix and Ilizarov external fixators Journal of Biomechanics 25 1992 995 1006
    • (1992) Journal of Biomechanics , vol.25 , pp. 995-1006
    • Juan, J.A.1    Prat, J.2    Vera, P.3    Hoyos, J.V.4    Sanchez-Lacuesta, J.5    Peris, J.L.6
  • 17
    • 0027385338 scopus 로고
    • A finite element analysis of the effect of pin distribution on the rigidity of a unilateral external fixation system
    • O.O.A. Oni, M. Capper, and C. Soutis A finite element analysis of the effect of pin distribution on the rigidity of a unilateral external fixation system Injury 24 1993 525 527
    • (1993) Injury , vol.24 , pp. 525-527
    • Oni, O.O.A.1    Capper, M.2    Soutis, C.3
  • 19
    • 84858276696 scopus 로고    scopus 로고
    • Investigation of factors affecting loosening of Ilizarov ring-wire external fixator systems at the bone-wire interface
    • F.E. Donaldson, P. Pankaj, and A.H.R.W. Simpson Investigation of factors affecting loosening of Ilizarov ring-wire external fixator systems at the bone-wire interface Journal of Orthopaedic Research 30 2012 726 732
    • (2012) Journal of Orthopaedic Research , vol.30 , pp. 726-732
    • Donaldson, F.E.1    Pankaj, P.2    Simpson, A.H.R.W.3
  • 20
    • 77952876793 scopus 로고    scopus 로고
    • Finite element modelling of a unilateral fixator for bone reconstruction: Importance of contact settings
    • K. Karunratanakul, J. Schrooten, and H. Van Oosterwyck Finite element modelling of a unilateral fixator for bone reconstruction: Importance of contact settings Medical Engineering and Physics 32 2010 461 467
    • (2010) Medical Engineering and Physics , vol.32 , pp. 461-467
    • Karunratanakul, K.1    Schrooten, J.2    Van Oosterwyck, H.3
  • 21
    • 2942612757 scopus 로고    scopus 로고
    • Fracture stabilization with type II external fixator vs. type i external fixator with im pin
    • R. Shahar, and Y. Shani Fracture stabilization with type II external fixator vs. type I external fixator with IM pin Veterinary and Comparative Orthopaedics and Traumatology 17 2004 91 96
    • (2004) Veterinary and Comparative Orthopaedics and Traumatology , vol.17 , pp. 91-96
    • Shahar, R.1    Shani, Y.2
  • 22
    • 0024462229 scopus 로고
    • Identification of the elastic symmetry of bone and other materials
    • S.C. Cowin, and M.M. Mehrabadi Identification of the elastic symmetry of bone and other materials Journal of Biomechanics 22 1989 503 515
    • (1989) Journal of Biomechanics , vol.22 , pp. 503-515
    • Cowin, S.C.1    Mehrabadi, M.M.2
  • 23
    • 0026982450 scopus 로고
    • A performance study of tetrahedral and hexahedral elements in 3-D finite element structural analysis
    • A.O. Cifuentes, and A. Kalbag A performance study of tetrahedral and hexahedral elements in 3-D finite element structural analysis Finite Elements in Analysis and Design 12 1992 313 318
    • (1992) Finite Elements in Analysis and Design , vol.12 , pp. 313-318
    • Cifuentes, A.O.1    Kalbag, A.2
  • 24
    • 0031072752 scopus 로고    scopus 로고
    • Averaging anisotropic elastic constant data
    • S.C. Cowin, and G. Yang Averaging anisotropic elastic constant data Journal of Elasticity 46 1997 151 180
    • (1997) Journal of Elasticity , vol.46 , pp. 151-180
    • Cowin, S.C.1    Yang, G.2
  • 25
    • 34047254339 scopus 로고    scopus 로고
    • Strain redistribution and cracking behaviour of human bone during bending
    • V. Ebacher, C. Tang, H. McKay, T.R. Oxland, P. Guy, and R. Wang Strain redistribution and cracking behaviour of human bone during bending Bone 40 2007 1265 1275
    • (2007) Bone , vol.40 , pp. 1265-1275
    • Ebacher, V.1    Tang, C.2    McKay, H.3    Oxland, T.R.4    Guy, P.5    Wang, R.6
  • 26
    • 33644803353 scopus 로고    scopus 로고
    • Mechanisms governing the inelastic deformation of cortical bone and application to trabecular bone
    • C. Mercer, M.Y. He, R. Wang, and A.G. Evans Mechanisms governing the inelastic deformation of cortical bone and application to trabecular bone Acta Biomaterialia 2 2006 59 68
    • (2006) Acta Biomaterialia , vol.2 , pp. 59-68
    • Mercer, C.1    He, M.Y.2    Wang, R.3    Evans, A.G.4
  • 28
    • 0036269098 scopus 로고    scopus 로고
    • Optimizing the biomechanical compatibility of orthopedic screws for bone fracture fixation
    • A. Gefen Optimizing the biomechanical compatibility of orthopedic screws for bone fracture fixation Medical Engineering and Physics 24 2002 337 347
    • (2002) Medical Engineering and Physics , vol.24 , pp. 337-347
    • Gefen, A.1
  • 30
    • 0029822858 scopus 로고    scopus 로고
    • Biomechanics of transfixation in pedicle screw instrumentation
    • T.-H. Lim, J.C. Eck, H. An, J.H. Hong, J.-Y. Ahn, and J.W. You Biomechanics of transfixation in pedicle screw instrumentation Spine 21 1996 2224 2229
    • (1996) Spine , vol.21 , pp. 2224-2229
    • Lim, T.-H.1    Eck, J.C.2    An, H.3    Hong, J.H.4    Ahn, J.-Y.5    You, J.W.6
  • 31
    • 0037400997 scopus 로고    scopus 로고
    • Biomechanical investigation of pedicle screw-vertebrae complex: A finite element approach using bonded and contact interface conditions
    • S.I. Chen, R.M. Lin, and C.H. Chang Biomechanical investigation of pedicle screw-vertebrae complex: a finite element approach using bonded and contact interface conditions Medical Engineering and Physics 25 2003 275 282
    • (2003) Medical Engineering and Physics , vol.25 , pp. 275-282
    • Chen, S.I.1    Lin, R.M.2    Chang, C.H.3
  • 32
    • 0141453861 scopus 로고    scopus 로고
    • The many adaptations of bone
    • J.D. Currey The many adaptations of bone Journal of Biomechanics 36 2003 1487 1495
    • (2003) Journal of Biomechanics , vol.36 , pp. 1487-1495
    • Currey, J.D.1
  • 33
    • 0038174611 scopus 로고    scopus 로고
    • Treatment of displaced bicondylar tibial plateau fractures (OTA-41C2&3) in patients older than 60 years of age
    • A.M. Ali, M. Burton, M. Hashmi, and M. Saleh Treatment of displaced bicondylar tibial plateau fractures (OTA-41C2&3) in patients older than 60 years of age Journal of Orthopaedic Trauma 17 2003 346 352
    • (2003) Journal of Orthopaedic Trauma , vol.17 , pp. 346-352
    • Ali, A.M.1    Burton, M.2    Hashmi, M.3    Saleh, M.4
  • 34
    • 33751517410 scopus 로고    scopus 로고
    • Why fine-wire fixators work: An analysis of pressure distribution at the wire-bone interface
    • T.N. Board, L. Yang, and M. Saleh Why fine-wire fixators work: an analysis of pressure distribution at the wire-bone interface Journal of Biomechanics 40 2007 20 25
    • (2007) Journal of Biomechanics , vol.40 , pp. 20-25
    • Board, T.N.1    Yang, L.2    Saleh, M.3
  • 35
    • 0013888833 scopus 로고
    • Cancellous bone: Its strength and changes with aging and an evaluation of some methods for measuring its mineral content
    • J.K. Weaver, and J. Chalmers Cancellous bone: its strength and changes with aging and an evaluation of some methods for measuring its mineral content The Journal of Bone and Joint Surgery (American) 48-A 1966 289 298
    • (1966) The Journal of Bone and Joint Surgery (American) , vol.48 , pp. 289-298
    • Weaver, J.K.1    Chalmers, J.2
  • 36
    • 0021690879 scopus 로고
    • Comparison of osteotomy healing under external fixation devices with different stiffness characteristics
    • J.J. Wu, H.S. Shyr, E.Y. Chao, and P.J. Kelly Comparison of osteotomy healing under external fixation devices with different stiffness characteristics The Journal of Bone and Joint Surgery (American) 66 1984 1258 1264
    • (1984) The Journal of Bone and Joint Surgery (American) , vol.66 , pp. 1258-1264
    • Wu, J.J.1    Shyr, H.S.2    Chao, E.Y.3    Kelly, P.J.4
  • 38
    • 0024636172 scopus 로고
    • Measurement of fracture movement in patients treated with unilateral external skeletal fixation
    • J.L. Cunningham, M. Evans, and J. Kenwright Measurement of fracture movement in patients treated with unilateral external skeletal fixation Journal of Biomedical Engineering 11 1989 118 122
    • (1989) Journal of Biomedical Engineering , vol.11 , pp. 118-122
    • Cunningham, J.L.1    Evans, M.2    Kenwright, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.