메뉴 건너뛰기




Volumn 21, Issue 1, 2006, Pages 49-53

Load transmission through a healing tibial fracture

Author keywords

External fixator; Load transmission; Tibial fracture; Weightbearing

Indexed keywords

FRACTURE; STRESSES; TISSUE; TOMOGRAPHY;

EID: 28444445977     PISSN: 02680033     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clinbiomech.2005.08.011     Document Type: Article
Times cited : (24)

References (13)
  • 1
    • 0021073859 scopus 로고
    • Monitoring fracture site properties with external fixation
    • G.S. Beaupre, W.C. Hayes, M.H. Jofe, and A.A. White Monitoring fracture site properties with external fixation Trans. ASME 105 1983 120 126
    • (1983) Trans. ASME , vol.105 , pp. 120-126
    • Beaupre, G.S.1    Hayes, W.C.2    Jofe, M.H.3    White, A.A.4
  • 2
    • 0017698252 scopus 로고
    • The compressive behaviour of bone as a two-phase porous structure
    • D.R. Carter, and W.C. Hayes The compressive behaviour of bone as a two-phase porous structure J. Bone. Joint Surg. 59-A 1977 954 996
    • (1977) J. Bone. Joint Surg. , vol.59 A , pp. 954-996
    • Carter, D.R.1    Hayes, W.C.2
  • 4
    • 0033104459 scopus 로고    scopus 로고
    • Magnitude of local stress and strain along bony surfaces predict the course and type of fracture healing
    • L.E. Claes, and C.A. Heigele Magnitude of local stress and strain along bony surfaces predict the course and type of fracture healing J. Biomech. 32 1999 255 266
    • (1999) J. Biomech. , vol.32 , pp. 255-266
    • Claes, L.E.1    Heigele, C.A.2
  • 5
    • 0026945142 scopus 로고
    • Relative stiffness, transverse displacement and dynamisation in comparable external fixators
    • T.N. Gardner, and M. Evans Relative stiffness, transverse displacement and dynamisation in comparable external fixators Clin. Biomech. 7 1992 231 239
    • (1992) Clin. Biomech. , vol.7 , pp. 231-239
    • Gardner, T.N.1    Evans, M.2
  • 6
    • 0030175608 scopus 로고    scopus 로고
    • The influence of external fixators on fracture motion during simulated walking
    • T.N. Gardner, M. Evans, and J. Kenwright The influence of external fixators on fracture motion during simulated walking J. Med. Eng. Phys. 18 1996 305 313
    • (1996) J. Med. Eng. Phys. , vol.18 , pp. 305-313
    • Gardner, T.N.1    Evans, M.2    Kenwright, J.3
  • 7
    • 0030298494 scopus 로고    scopus 로고
    • An instrumented spatial linkage for monitoring relative three-dimensional motion between fracture fragments
    • T.N. Gardner, M. Evans, and P.J. Kyberd An instrumented spatial linkage for monitoring relative three-dimensional motion between fracture fragments J. Biomech. Eng., ASME 118 1996 586 594
    • (1996) J. Biomech. Eng., ASME , vol.118 , pp. 586-594
    • Gardner, T.N.1    Evans, M.2    Kyberd, P.J.3
  • 8
    • 0033968708 scopus 로고    scopus 로고
    • The influence of mechanical stimulus on the pattern of tissue differentiation in a long bone fracture-an FEM study
    • T.N. Gardner, L. Marks, T. Stoll, and M. Knothe-Tate The influence of mechanical stimulus on the pattern of tissue differentiation in a long bone fracture-an FEM study J. Biomech. 33 2000 415 425
    • (2000) J. Biomech. , vol.33 , pp. 415-425
    • Gardner, T.N.1    Marks, L.2    Stoll, T.3    Knothe-Tate, M.4
  • 9
    • 0026735701 scopus 로고
    • Biomechanical study on the load-bearing characteristics of the fibula and the effects of fibular resection
    • J.C.H. Goh, E.H. Lee, E.J. Ang, P. Bayon, and R.W.H. Pho Biomechanical study on the load-bearing characteristics of the fibula and the effects of fibular resection Clin. Orthop. Rel. Res. 279 1992 223 228
    • (1992) Clin. Orthop. Rel. Res. , vol.279 , pp. 223-228
    • Goh, J.C.H.1    Lee, E.H.2    Ang, E.J.3    Bayon, P.4    Pho, R.W.H.5
  • 10
    • 0034988888 scopus 로고    scopus 로고
    • Forces and moments telemetered from two distal femoral replacements during various activities
    • S.J.G. Taylor, and P.S. Walker Forces and moments telemetered from two distal femoral replacements during various activities J. Biomech. 34 2001 839 848
    • (2001) J. Biomech. , vol.34 , pp. 839-848
    • Taylor, S.J.G.1    Walker, P.S.2
  • 11
    • 0031838760 scopus 로고    scopus 로고
    • The forces in the distal femur and the knee during walking and other activities measured by telemetry
    • S.J.G. Taylor, P.S. Walker, J.S. Perry, S.R. Cannon, and R. Woledge The forces in the distal femur and the knee during walking and other activities measured by telemetry J. Arthroplast. 13 1998 428 437
    • (1998) J. Arthroplast. , vol.13 , pp. 428-437
    • Taylor, S.J.G.1    Walker, P.S.2    Perry, J.S.3    Cannon, S.R.4    Woledge, R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.