-
1
-
-
0035947890
-
Carbon monoxide poisoning of proton exchange membrane fuel cells
-
J.J. Baschuk, and X. Li Carbon monoxide poisoning of proton exchange membrane fuel cells Int J Energy Res 25 2001 695 713
-
(2001)
Int J Energy Res
, vol.25
, pp. 695-713
-
-
Baschuk, J.J.1
Li, X.2
-
2
-
-
0347388416
-
The CO poisoning effect in PEMFCs operational at temperatures up to 200 °c
-
Q. Li, R. He, J. Gao, J.O. Jensen, and N.J. Bjerrum The CO poisoning effect in PEMFCs operational at temperatures up to 200 °C J Electrochem Soc 150 2003 A1599 A1605
-
(2003)
J Electrochem Soc
, vol.150
-
-
Li, Q.1
He, R.2
Gao, J.3
Jensen, J.O.4
Bjerrum, N.J.5
-
3
-
-
33745695503
-
-
2nd ed. John Wiley & Sons, Inc. Hoboken, New Jersey
-
R.P. O'Hayre, S.W. Cha, W. Colella, and F.B. Prinz Fuel cell fundamentals 2nd ed. 2009 John Wiley & Sons, Inc. Hoboken, New Jersey
-
(2009)
Fuel Cell Fundamentals
-
-
O'Hayre, R.P.1
Cha, S.W.2
Colella, W.3
Prinz, F.B.4
-
6
-
-
67949120221
-
2-rich gases with a samarium doped ceria (SDC) sensor for fuel cell application
-
2-rich gases with a samarium doped ceria (SDC) sensor for fuel cell application Sens Actuators B 141 2009 7 12
-
(2009)
Sens Actuators B
, vol.141
, pp. 7-12
-
-
Pijolat, C.1
Tournier, G.2
Viricelle, J.P.3
-
9
-
-
0037512516
-
Detection of CO in a reducing, hydrous environment using CuBr as electrolyte
-
C.V. Gopal Reddy, P.K. Dutta, and S.A. Akbar Detection of CO in a reducing, hydrous environment using CuBr as electrolyte Sens Actuators B 92 2003 351 355
-
(2003)
Sens Actuators B
, vol.92
, pp. 351-355
-
-
Gopal Reddy, C.V.1
Dutta, P.K.2
Akbar, S.A.3
-
10
-
-
0037146563
-
Carbon monoxide sensor for PEM fuel cell systems
-
C.T. Holt, A.M. Azad, S.L. Swartz, R.R. Rao, and P.K. Dutta Carbon monoxide sensor for PEM fuel cell systems Sens Actuators B 87 2002 414 420
-
(2002)
Sens Actuators B
, vol.87
, pp. 414-420
-
-
Holt, C.T.1
Azad, A.M.2
Swartz, S.L.3
Rao, R.R.4
Dutta, P.K.5
-
11
-
-
0037199891
-
Solid oxide fuel cells that enable the detection of CO in reformed gases
-
A. Hashimoto, T. Hibino, and M. Sano Solid oxide fuel cells that enable the detection of CO in reformed gases Sens Actuators B 86 2002 12 19
-
(2002)
Sens Actuators B
, vol.86
, pp. 12-19
-
-
Hashimoto, A.1
Hibino, T.2
Sano, M.3
-
12
-
-
0042234121
-
Detection of low level carbon monoxide in hydrogen-rich gas streams
-
K.W. Kirby, A.C. Chu, and K.C. Fuller Detection of low level carbon monoxide in hydrogen-rich gas streams Sens Actuators B 95 2003 224 231
-
(2003)
Sens Actuators B
, vol.95
, pp. 224-231
-
-
Kirby, K.W.1
Chu, A.C.2
Fuller, K.C.3
-
13
-
-
10044275478
-
A low temperature sensor for the detection of carbon monoxide in hydrogen
-
R. Mukundan, E.L. Brosha, and F.H. Garzon A low temperature sensor for the detection of carbon monoxide in hydrogen Solid State Ionics 175 2004 497 501
-
(2004)
Solid State Ionics
, vol.175
, pp. 497-501
-
-
Mukundan, R.1
Brosha, E.L.2
Garzon, F.H.3
-
15
-
-
34047135967
-
Gas sensor based on conducting polymers
-
H. Bai, and G.Q. Shi Gas sensor based on conducting polymers Sensors 7 2007 267 307
-
(2007)
Sensors
, vol.7
, pp. 267-307
-
-
Bai, H.1
Shi, G.Q.2
-
17
-
-
33751322656
-
Hydrogen sensors based on conductivity changes in polyaniline nanofibers
-
S. Virji, R.B. Kaner, and B.H. Weiller Hydrogen sensors based on conductivity changes in polyaniline nanofibers J Phys Chem B 110 2006 22266 22270
-
(2006)
J Phys Chem B
, vol.110
, pp. 22266-22270
-
-
Virji, S.1
Kaner, R.B.2
Weiller, B.H.3
-
18
-
-
34548182876
-
Doped and dedoped polyaniline nanofiber based conductometric hydrogen gas sensors
-
A.Z. Sadek, W. Wlodarski, K. Kalantar-Zadeh, C. Baker, and R.B. Kaner Doped and dedoped polyaniline nanofiber based conductometric hydrogen gas sensors Sens Actuators B 139 2007 53 57
-
(2007)
Sens Actuators B
, vol.139
, pp. 53-57
-
-
Sadek, A.Z.1
Wlodarski, W.2
Kalantar-Zadeh, K.3
Baker, C.4
Kaner, R.B.5
-
19
-
-
3042817795
-
Vacuum-deposited nanocrystallline polyaniline thin film sensors for detection of carbon monoxide
-
S.C.K. Misra, P. Mathur, and B.K. Srivastava Vacuum-deposited nanocrystallline polyaniline thin film sensors for detection of carbon monoxide Sens Actuators B 114 2004 30 35
-
(2004)
Sens Actuators B
, vol.114
, pp. 30-35
-
-
Misra, S.C.K.1
Mathur, P.2
Srivastava, B.K.3
-
21
-
-
72149100979
-
Electrochemical deposition of nanostructured polyaniline on an insulating substrate
-
C. Liu, K. Hayashi, and K. Toko Electrochemical deposition of nanostructured polyaniline on an insulating substrate Electrochem Commun 12 2010 36 39
-
(2010)
Electrochem Commun
, vol.12
, pp. 36-39
-
-
Liu, C.1
Hayashi, K.2
Toko, K.3
-
22
-
-
79953857435
-
Template-free deposition of polyaniline nanostructures on solid substrates with horizontal orientation
-
C. Liu, K. Hayashi, and K. Toko Template-free deposition of polyaniline nanostructures on solid substrates with horizontal orientation Macromolecules 44 2011 2212 2219
-
(2011)
Macromolecules
, vol.44
, pp. 2212-2219
-
-
Liu, C.1
Hayashi, K.2
Toko, K.3
-
23
-
-
0037020380
-
Direct assembly of large arrays of oriented conducting polymer nanowires
-
L. Liang, J. Liu, C.F. Windisch, G.C. Exarhos, and Y. Lin Direct assembly of large arrays of oriented conducting polymer nanowires Angew Chem Int Ed 41 2002 3665 3668
-
(2002)
Angew Chem Int Ed
, vol.41
, pp. 3665-3668
-
-
Liang, L.1
Liu, J.2
Windisch, C.F.3
Exarhos, G.C.4
Lin, Y.5
-
24
-
-
34249938475
-
Growth and alignment of polyaniline nanofibers with superhydrophobic, superhydrophilic and other properties
-
N. Chiou, C. Liu, J. Guan, L.J. Lee, and A.J. Epstein Growth and alignment of polyaniline nanofibers with superhydrophobic, superhydrophilic and other properties Nat Nanotech 2 2007 354 357
-
(2007)
Nat Nanotech
, vol.2
, pp. 354-357
-
-
Chiou, N.1
Liu, C.2
Guan, J.3
Lee, L.J.4
Epstein, A.J.5
-
25
-
-
70349208458
-
Characterization of gas sensing behavior of multi walled carbon nanotube polyaniline composite fulms
-
S. Srivastava, S.S. Sharma, S. Agrawal, S. Kumar, S. Agrawal, and M. Singh Characterization of gas sensing behavior of multi walled carbon nanotube polyaniline composite fulms Int J Hydrogen Energy 34 2009 8445 8450
-
(2009)
Int J Hydrogen Energy
, vol.34
, pp. 8445-8450
-
-
Srivastava, S.1
Sharma, S.S.2
Agrawal, S.3
Kumar, S.4
Agrawal, S.5
Singh, M.6
-
26
-
-
77957608946
-
Graphene/polyaniline nanocomposite for hydrogen sensing
-
L. Al-Mashat, K. Shin, K. Kalantar-zadeh, J.D. Plessis, S.H. Han, and R.W. Kojima Graphene/polyaniline nanocomposite for hydrogen sensing J Phys Chem C 114 2010 16168 16173
-
(2010)
J Phys Chem C
, vol.114
, pp. 16168-16173
-
-
Al-Mashat, L.1
Shin, K.2
Kalantar-Zadeh, K.3
Plessis, J.D.4
Han, S.H.5
Kojima, R.W.6
-
27
-
-
8344242962
-
Effect of morphology on the response of polyaniline-based conductometric gas sensors: Nanofibers vs. thin films
-
G.F. Li, C. Martinez, J. Janata, J.A. Smith, M. Josowica, and S. Semancik Effect of morphology on the response of polyaniline-based conductometric gas sensors: nanofibers vs. thin films Electrochem Solid-State Lett 7 2004 H44 H47
-
(2004)
Electrochem Solid-State Lett
, vol.7
-
-
Li, G.F.1
Martinez, C.2
Janata, J.3
Smith, J.A.4
Josowica, M.5
Semancik, S.6
-
28
-
-
0042591804
-
Investigation of contact and bulk resistance of conducting polymers by simultaneous two- and four-point technique
-
Q. Hao, V. Kulikov, and V.M. Mirsky Investigation of contact and bulk resistance of conducting polymers by simultaneous two- and four-point technique Sens Actuators B 94 2003 352 357
-
(2003)
Sens Actuators B
, vol.94
, pp. 352-357
-
-
Hao, Q.1
Kulikov, V.2
Mirsky, V.M.3
-
30
-
-
84856213186
-
Au nanoparticles decorated polyaniline nanofiber sensor for detecting volatile sulfur compounds in expired breath
-
C. Liu, K. Hayashi, and K. Toko Au nanoparticles decorated polyaniline nanofiber sensor for detecting volatile sulfur compounds in expired breath Sens Actuators B 161 2012 504 509
-
(2012)
Sens Actuators B
, vol.161
, pp. 504-509
-
-
Liu, C.1
Hayashi, K.2
Toko, K.3
|