Volumn 141, Issue 1, 2009, Pages 7-12

Detection of CO in H2-rich gases with a samarium doped ceria (SDC) sensor for fuel cell applications

Author keywords

CO detection; Fuel cell; Hydrogen rich gases; SCD sensors

Indexed keywords

CARRIER GAS; CO CONCENTRATIONS; CO DETECTION; ELECTRICAL CONTACTS; EXCHANGE MEMBRANES; FUEL CELL APPLICATION; HOT PLATES; LABORATORY TESTING; MEASUREMENT CELL; PROTONIC; REVERSE SIDE; SAMARIUM DOPED CERIAS; SCD SENSORS; SENSOR RESPONSE;

EID: 67949120221     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2009.06.004     Document Type: Article
Times cited : (20)

References (15)
  • 3
    • 0037512516 scopus 로고    scopus 로고
    • Detection of CO in a reducing, hydrous environment using CuBr as electrolyte
    • Reddy G., Dutta P.K., and Akbar S.A. Detection of CO in a reducing, hydrous environment using CuBr as electrolyte. Sens. Actuators B 92 (2003) 351-355
    • (2003) Sens. Actuators B , vol.92 , pp. 351-355
    • Reddy, G.1    Dutta, P.K.2    Akbar, S.A.3
  • 4
    • 10044275478 scopus 로고    scopus 로고
    • A low temperature sensor for the detection of carbon monoxide in hydrogen
    • Mukundan R., Brosha E.L., and Garzon F.H. A low temperature sensor for the detection of carbon monoxide in hydrogen. Solid State Ionics 175 (2004) 497-501
    • (2004) Solid State Ionics , vol.175 , pp. 497-501
    • Mukundan, R.1    Brosha, E.L.2    Garzon, F.H.3
  • 5
    • 0042234121 scopus 로고    scopus 로고
    • Detection of low level carbon monoxide in hydrogen-rich gas streams
    • Kirby K.W., Chu A.C., and Fuller K.C. Detection of low level carbon monoxide in hydrogen-rich gas streams. Sens. Actuators B 95 (2003) 224-231
    • (2003) Sens. Actuators B , vol.95 , pp. 224-231
    • Kirby, K.W.1    Chu, A.C.2    Fuller, K.C.3
  • 6
    • 0037199891 scopus 로고    scopus 로고
    • Solid oxide fuel cells that enable the detection of CO in reformed gases
    • Hashimoto A., Hibino T., and Sano M. Solid oxide fuel cells that enable the detection of CO in reformed gases. Sens. Actuators B 86 (2002) 12-19
    • (2002) Sens. Actuators B , vol.86 , pp. 12-19
    • Hashimoto, A.1    Hibino, T.2    Sano, M.3
  • 7
    • 0036741927 scopus 로고    scopus 로고
    • Development of a gas sensor by thick film technology for automotive applications: choice of materials-realization of a prototype
    • Guillet N., Lalauze R., Viricelle J.P., Pijolat C., and Montanaro L. Development of a gas sensor by thick film technology for automotive applications: choice of materials-realization of a prototype. Mater. Sci. Eng. C 21 (2002) 97-103
    • (2002) Mater. Sci. Eng. C , vol.21 , pp. 97-103
    • Guillet, N.1    Lalauze, R.2    Viricelle, J.P.3    Pijolat, C.4    Montanaro, L.5
  • 9
    • 29344440831 scopus 로고    scopus 로고
    • Dependence of potentiometric oxygen sensing characteristics on the nature of electrodes
    • Ramamoorthy R., Akbar S.A., and Dutta P.K. Dependence of potentiometric oxygen sensing characteristics on the nature of electrodes. Sens. Actuators B 113 (2006) 162-168
    • (2006) Sens. Actuators B , vol.113 , pp. 162-168
    • Ramamoorthy, R.1    Akbar, S.A.2    Dutta, P.K.3
  • 10
    • 40749152354 scopus 로고    scopus 로고
    • 2 sensing performances of planar sensor using stabilized zirconia and thin-NiO sensing electrode
    • 2 sensing performances of planar sensor using stabilized zirconia and thin-NiO sensing electrode. Sens. Actuators B 130 (2008) 231-239
    • (2008) Sens. Actuators B , vol.130 , pp. 231-239
    • Plashnitsa a, V.1    Uedab, T.2    Elumalai a, P.3    Miura, N.4
  • 11
    • 1342328130 scopus 로고    scopus 로고
    • Oxygen and carbon monoxide role on the electrical response of a non-Nernstian potentiometric gas sensor; proposition of a model
    • Guillet N., Lalauze R., and Pijolat C. Oxygen and carbon monoxide role on the electrical response of a non-Nernstian potentiometric gas sensor; proposition of a model. Sens. Actuators B 98 (2004) 130-139
    • (2004) Sens. Actuators B , vol.98 , pp. 130-139
    • Guillet, N.1    Lalauze, R.2    Pijolat, C.3
  • 13
    • 33748756336 scopus 로고    scopus 로고
    • Mixed potential NOx sensors using thin film electrodes and electrolytes for stationary reciprocating engine type applications
    • Brosha E.L., Mukundan R., Lujan R., and Garzon F.H. Mixed potential NOx sensors using thin film electrodes and electrolytes for stationary reciprocating engine type applications. Sens. Actuators B 119 (2006) 398-408
    • (2006) Sens. Actuators B , vol.119 , pp. 398-408
    • Brosha, E.L.1    Mukundan, R.2    Lujan, R.3    Garzon, F.H.4
  • 14
    • 29344465173 scopus 로고    scopus 로고
    • Absolute potential analysis of the mixed potential occurring at the oxide/YSZ electrode at high temperature in NOx-containing air
    • Park a C.O., and Miura N. Absolute potential analysis of the mixed potential occurring at the oxide/YSZ electrode at high temperature in NOx-containing air. Sens. Actuators B 113 (2006) 316-319
    • (2006) Sens. Actuators B , vol.113 , pp. 316-319
    • Park a, C.O.1    Miura, N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.