-
1
-
-
34249805397
-
Mid-term results of cementless total hip replacement using a ceramic-on-ceramic bearing with and without computer navigation
-
Sugano N., Nishii T., Miki H., et al. Mid-term results of cementless total hip replacement using a ceramic-on-ceramic bearing with and without computer navigation. J Bone Joint Surg Br 2007, 89:455.
-
(2007)
J Bone Joint Surg Br
, vol.89
, pp. 455
-
-
Sugano, N.1
Nishii, T.2
Miki, H.3
-
2
-
-
57649088878
-
Effect of reduced diameter neck stem on incidence of radiographic cup loosening and revisions in Charnley low-frictional torque arthroplasty
-
Wroblewski B.M., Siney P.D., Fleming P.A. Effect of reduced diameter neck stem on incidence of radiographic cup loosening and revisions in Charnley low-frictional torque arthroplasty. J Arthroplasty 2009, 24:10.
-
(2009)
J Arthroplasty
, vol.24
, pp. 10
-
-
Wroblewski, B.M.1
Siney, P.D.2
Fleming, P.A.3
-
3
-
-
0016707369
-
Range of motion studies for total hip replacements. A comparative study with a new experimental apparatus
-
Amstutz H.C., Lodwig R.M., Schurman D.J., et al. Range of motion studies for total hip replacements. A comparative study with a new experimental apparatus. Clin Orthop Relat Res 1975, 111:124.
-
(1975)
Clin Orthop Relat Res
, vol.111
, pp. 124
-
-
Amstutz, H.C.1
Lodwig, R.M.2
Schurman, D.J.3
-
4
-
-
0020074590
-
Prosthetic hip range of motion and impingement. The effects of head and neck geometry
-
Chandler D.R., Glousman R., Hull D., et al. Prosthetic hip range of motion and impingement. The effects of head and neck geometry. Clin Orthop Relat Res 1982, 166:284.
-
(1982)
Clin Orthop Relat Res
, vol.166
, pp. 284
-
-
Chandler, D.R.1
Glousman, R.2
Hull, D.3
-
5
-
-
0023778007
-
Position, orientation and component interaction in dislocation of the total hip prosthesis
-
Herrlin K., Selvik G., Pettersson H., et al. Position, orientation and component interaction in dislocation of the total hip prosthesis. Acta Radiol 1988, 29:441.
-
(1988)
Acta Radiol
, vol.29
, pp. 441
-
-
Herrlin, K.1
Selvik, G.2
Pettersson, H.3
-
6
-
-
0024243572
-
Range of motion caused by design of the total hip prosthesis
-
Herrlin K., Selvik G., Pettersson H., et al. Range of motion caused by design of the total hip prosthesis. Acta Radiol 1988, 29:701.
-
(1988)
Acta Radiol
, vol.29
, pp. 701
-
-
Herrlin, K.1
Selvik, G.2
Pettersson, H.3
-
7
-
-
0037398768
-
Kinematics, kinetics, and finite element analysis of commonplace maneuvers at risk for total hip dislocation
-
Nadzadi M.E., Pedersen D.R., Yack H.J., et al. Kinematics, kinetics, and finite element analysis of commonplace maneuvers at risk for total hip dislocation. J Biomech 2003, 36:577.
-
(2003)
J Biomech
, vol.36
, pp. 577
-
-
Nadzadi, M.E.1
Pedersen, D.R.2
Yack, H.J.3
-
8
-
-
2942615374
-
Compliant positioning of total hip components for optimal range of motion
-
Widmer K.H., Zurfluh B. Compliant positioning of total hip components for optimal range of motion. J Orthop Res 2004, 22:815.
-
(2004)
J Orthop Res
, vol.22
, pp. 815
-
-
Widmer, K.H.1
Zurfluh, B.2
-
9
-
-
0034868709
-
Activities of daily living in non-Western cultures: range of motion requirements for hip and knee joint implants
-
Mulholland S.J., Wyss U.P. Activities of daily living in non-Western cultures: range of motion requirements for hip and knee joint implants. Int J Rehabil Res 2001, 24:191.
-
(2001)
Int J Rehabil Res
, vol.24
, pp. 191
-
-
Mulholland, S.J.1
Wyss, U.P.2
-
10
-
-
37349117304
-
Open-configuration MRI study of femoro-acetabular impingement
-
Yamamura M., Miki H., Nakamura N., et al. Open-configuration MRI study of femoro-acetabular impingement. J Orthop Res 2007, 25:1582.
-
(2007)
J Orthop Res
, vol.25
, pp. 1582
-
-
Yamamura, M.1
Miki, H.2
Nakamura, N.3
-
11
-
-
11144355411
-
A novel system of four-dimensional motion analysis after total hip arthroplasty
-
Hagio K., Sugano N., Nishii T., et al. A novel system of four-dimensional motion analysis after total hip arthroplasty. J Orthop Res 2004, 22:665.
-
(2004)
J Orthop Res
, vol.22
, pp. 665
-
-
Hagio, K.1
Sugano, N.2
Nishii, T.3
-
12
-
-
26444618521
-
Four-dimensional model of the lower extremity after total hip arthroplasty
-
Otake Y., Suzuki N., Hattori A., et al. Four-dimensional model of the lower extremity after total hip arthroplasty. J Biomech 2005, 38:2397.
-
(2005)
J Biomech
, vol.38
, pp. 2397
-
-
Otake, Y.1
Suzuki, N.2
Hattori, A.3
-
13
-
-
34848905651
-
Anatomic hip range of motion after implantation during total hip arthroplasty as measured by a navigation system
-
Miki H., Yamanashi W., Nishii T., et al. Anatomic hip range of motion after implantation during total hip arthroplasty as measured by a navigation system. J Arthroplasty 2007, 22:946-952.
-
(2007)
J Arthroplasty
, vol.22
, pp. 946-952
-
-
Miki, H.1
Yamanashi, W.2
Nishii, T.3
-
14
-
-
0014525462
-
Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation
-
Harris W.H. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am 1969, 51:737.
-
(1969)
J Bone Joint Surg Am
, vol.51
, pp. 737
-
-
Harris, W.H.1
-
15
-
-
0030836574
-
The influence of patient-related factors and the position of the acetabular component on the rate of dislocation after total hip replacement
-
Paterno S.A., Lachiewicz P.F., Kelley S.S. The influence of patient-related factors and the position of the acetabular component on the rate of dislocation after total hip replacement. J Bone Joint Surg Am 1997, 79:1202.
-
(1997)
J Bone Joint Surg Am
, vol.79
, pp. 1202
-
-
Paterno, S.A.1
Lachiewicz, P.F.2
Kelley, S.S.3
-
16
-
-
13444278486
-
The role of patient restrictions in reducing the prevalence of early dislocation following total hip arthroplasty. A randomized, prospective study
-
Peak E.L., Parvizi J., Ciminiello M., et al. The role of patient restrictions in reducing the prevalence of early dislocation following total hip arthroplasty. A randomized, prospective study. J Bone Joint Surg Am 2005, 87:247.
-
(2005)
J Bone Joint Surg Am
, vol.87
, pp. 247
-
-
Peak, E.L.1
Parvizi, J.2
Ciminiello, M.3
-
17
-
-
70450237086
-
Risk factors for revision total hip arthroplasty: emphasis on the characteristics of Japanese lifestyle
-
Satoh M., Kawaguchi T., Masuhara K. Risk factors for revision total hip arthroplasty: emphasis on the characteristics of Japanese lifestyle. Arch Orthop Trauma Surg 2009, 129:1707.
-
(2009)
Arch Orthop Trauma Surg
, vol.129
, pp. 1707
-
-
Satoh, M.1
Kawaguchi, T.2
Masuhara, K.3
-
18
-
-
0030111274
-
Position and orientation in space of bones during movement: experimental artefacts
-
Cappozzo A., Catani F., Leardini A., et al. Position and orientation in space of bones during movement: experimental artefacts. Clin Biomech 1996, 11:90.
-
(1996)
Clin Biomech
, vol.11
, pp. 90
-
-
Cappozzo, A.1
Catani, F.2
Leardini, A.3
-
19
-
-
0031039789
-
Tibiocalcaneal motion during running, measured with external and bone markers
-
Reinschmidt C., van den Bogert A.J., Murphy N., et al. Tibiocalcaneal motion during running, measured with external and bone markers. Clin Biomech 1997, 12:8.
-
(1997)
Clin Biomech
, vol.12
, pp. 8
-
-
Reinschmidt, C.1
van den Bogert, A.J.2
Murphy, N.3
-
20
-
-
0031194416
-
Effect of skin movement on the analysis of skeletal knee joint motion during running
-
Reinschmidt C., van den Bogert A.J., Nigg B.M., et al. Effect of skin movement on the analysis of skeletal knee joint motion during running. J Biomech 1997, 30:729.
-
(1997)
J Biomech
, vol.30
, pp. 729
-
-
Reinschmidt, C.1
van den Bogert, A.J.2
Nigg, B.M.3
-
21
-
-
0035134053
-
Correcting for deformation in skin-based marker systems
-
Alexander E.J., Andriacchi T.P. Correcting for deformation in skin-based marker systems. J Biomech 2001, 34:355.
-
(2001)
J Biomech
, vol.34
, pp. 355
-
-
Alexander, E.J.1
Andriacchi, T.P.2
-
22
-
-
0032411404
-
A point cluster method for in vivo motion analysis: applied to a study of knee kinematics
-
Andriacchi T.P., Alexander E.J., Toney M.K., et al. A point cluster method for in vivo motion analysis: applied to a study of knee kinematics. J Biomech Eng 1998, 120:743.
-
(1998)
J Biomech Eng
, vol.120
, pp. 743
-
-
Andriacchi, T.P.1
Alexander, E.J.2
Toney, M.K.3
-
23
-
-
0032212111
-
Skin movement artefact assessment and compensation in the estimation of knee-joint kinematics
-
Lucchetti L., Cappozzo A., Cappello A., et al. Skin movement artefact assessment and compensation in the estimation of knee-joint kinematics. J Biomech 1998, 31:977.
-
(1998)
J Biomech
, vol.31
, pp. 977
-
-
Lucchetti, L.1
Cappozzo, A.2
Cappello, A.3
-
24
-
-
0033081306
-
Bone position estimation from skin marker co-ordinates using global optimisation with joint constraints
-
Lu T.W., O'Connor J.J. Bone position estimation from skin marker co-ordinates using global optimisation with joint constraints. J Biomech 1999, 32:129.
-
(1999)
J Biomech
, vol.32
, pp. 129
-
-
Lu, T.W.1
O'Connor, J.J.2
-
25
-
-
0018841551
-
Rigid body motion calculated from spatial co-ordinates of markers
-
Spoor C.W., Veldpaus F.E. Rigid body motion calculated from spatial co-ordinates of markers. J Biomech 1980, 13:391.
-
(1980)
J Biomech
, vol.13
, pp. 391
-
-
Spoor, C.W.1
Veldpaus, F.E.2
-
26
-
-
0032178167
-
The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment
-
DiGioia A.M., Jaramaz B., Blackwell M., et al. The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment. Clin Orthop Relat Res 1998, 355:8.
-
(1998)
Clin Orthop Relat Res
, vol.355
, pp. 8
-
-
DiGioia, A.M.1
Jaramaz, B.2
Blackwell, M.3
-
27
-
-
0031690023
-
Computer assisted measurement of cup placement in total hip replacement
-
Jaramaz B., DiGioia A.M., Blackwell M., et al. Computer assisted measurement of cup placement in total hip replacement. Clin Orthop Relat Res 1998, 354:70.
-
(1998)
Clin Orthop Relat Res
, vol.354
, pp. 70
-
-
Jaramaz, B.1
DiGioia, A.M.2
Blackwell, M.3
-
28
-
-
33646193989
-
Hip, knee, and ankle kinematics of high range of motion activities of daily living
-
Hemmerich A., Brown H., Smith S., et al. Hip, knee, and ankle kinematics of high range of motion activities of daily living. J Orthop Res 2006, 24:770.
-
(2006)
J Orthop Res
, vol.24
, pp. 770
-
-
Hemmerich, A.1
Brown, H.2
Smith, S.3
|