메뉴 건너뛰기




Volumn 81, Issue 10, 2012, Pages 2576-2584

Real-time elastography for the differentiation of benign and malignant superficial lymph nodes: A meta-analysis

Author keywords

Diagnostic accuracy; Elastography; Lymph nodes; Sensitivity; Specificity

Indexed keywords

ARTICLE; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; DIFFERENTIATION; ELASTOGRAPHY; HUMAN; LYMPH NODE; LYMPH NODE METASTASIS; LYMPHADENOPATHY; META ANALYSIS; PRIORITY JOURNAL; REAL TIME ELASTOGRAPHY; SENSITIVITY AND SPECIFICITY;

EID: 84865262319     PISSN: 0720048X     EISSN: 18727727     Source Type: Journal    
DOI: 10.1016/j.ejrad.2011.10.026     Document Type: Article
Times cited : (86)

References (18)
  • 1
    • 79955607707 scopus 로고    scopus 로고
    • Bilateral negative sentinel nodes accurately predict absence of lymph node metastasis in early cervical cancer: Results of the SENTICOL study
    • F. Lecuru, P. Mathevet, and D. Querleu Bilateral negative sentinel nodes accurately predict absence of lymph node metastasis in early cervical cancer: results of the SENTICOL study J Clin Oncol 29 13 2011 1686 1691
    • (2011) J Clin Oncol , vol.29 , Issue.13 , pp. 1686-1691
    • Lecuru, F.1    Mathevet, P.2    Querleu, D.3
  • 2
    • 77954200235 scopus 로고    scopus 로고
    • Diagnostic performance of computer tomography, magnetic resonance imaging, and positron emission tomography or positron emission tomography/computer tomography for detection of metastatic lymph nodes in patients with cervical cancer: Meta-analysis
    • H.J. Choi, W. Ju, and S.K. Myung Diagnostic performance of computer tomography, magnetic resonance imaging, and positron emission tomography or positron emission tomography/computer tomography for detection of metastatic lymph nodes in patients with cervical cancer: meta-analysis Cancer Sci 101 6 2010 1471 1479
    • (2010) Cancer Sci , vol.101 , Issue.6 , pp. 1471-1479
    • Choi, H.J.1    Ju, W.2    Myung, S.K.3
  • 4
    • 44349148710 scopus 로고    scopus 로고
    • Improving B mode ultrasound evaluation of breast lesions with real-time ultrasound elastography: A clinical approach
    • S.M. Tan, H.S. Teh, and J.F. Mancer Improving B mode ultrasound evaluation of breast lesions with real-time ultrasound elastography: a clinical approach Breast 17 3 2008 252 257
    • (2008) Breast , vol.17 , Issue.3 , pp. 252-257
    • Tan, S.M.1    Teh, H.S.2    Mancer, J.F.3
  • 5
    • 34147214914 scopus 로고    scopus 로고
    • Cervical lymph node metastases: Diagnosis at sonoelastography: Initial experience
    • A. Lyshchik, T. Higashi, and R. Asato Cervical lymph node metastases: diagnosis at sonoelastography: initial experience Radiology 243 1 2007 258 267
    • (2007) Radiology , vol.243 , Issue.1 , pp. 258-267
    • Lyshchik, A.1    Higashi, T.2    Asato, R.3
  • 6
    • 84861589673 scopus 로고    scopus 로고
    • Quantitative analysis of elastography images in the detection of breast cancer
    • 10.1016/j.ejrad.2011.04.012
    • V. Landoni, V. Francione, and S. Marzi Quantitative analysis of elastography images in the detection of breast cancer Eur J Radiol 2011 10.1016/j.ejrad.2011.04.012
    • (2011) Eur J Radiol
    • Landoni, V.1    Francione, V.2    Marzi, S.3
  • 7
    • 78449306435 scopus 로고    scopus 로고
    • Real-time qualitative ultrasound elastography of cervical lymph nodes in routine clinical practice: Interobserver agreement and correlation with malignancy
    • K.S. Bhatia, C.C. Cho, and Y.H. Yuen Real-time qualitative ultrasound elastography of cervical lymph nodes in routine clinical practice: interobserver agreement and correlation with malignancy Ultrasound Med Biol 36 12 2010 1990 1997
    • (2010) Ultrasound Med Biol , vol.36 , Issue.12 , pp. 1990-1997
    • Bhatia, K.S.1    Cho, C.C.2    Yuen, Y.H.3
  • 8
    • 2942700307 scopus 로고    scopus 로고
    • The development of QUADAS: A tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews
    • P. Whiting, A.W. Rutjes, and J.B. Reitsma The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews BMC Med Res Methodol 3 2003 25
    • (2003) BMC Med Res Methodol , vol.3 , pp. 25
    • Whiting, P.1    Rutjes, A.W.2    Reitsma, J.B.3
  • 9
    • 23644432857 scopus 로고    scopus 로고
    • The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed
    • J.J. Deeks, P. Macaskill, and L. Irwig The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed J Clin Epidemiol 58 9 2005 882 893
    • (2005) J Clin Epidemiol , vol.58 , Issue.9 , pp. 882-893
    • Deeks, J.J.1    MacAskill, P.2    Irwig, L.3
  • 10
    • 16244377720 scopus 로고    scopus 로고
    • A ruler for interpreting diagnostic test results
    • M. Hellmich, and W. Lehmacher A ruler for interpreting diagnostic test results Methods Inf Med 44 1 2005 124 126
    • (2005) Methods Inf Med , vol.44 , Issue.1 , pp. 124-126
    • Hellmich, M.1    Lehmacher, W.2
  • 11
    • 49149112778 scopus 로고    scopus 로고
    • Accuracy of sonographic elastography in the differential diagnosis of enlarged cervical lymph nodes: Comparison with conventional B-mode sonography
    • F. Alam, K. Naito, and J. Horiguchi Accuracy of sonographic elastography in the differential diagnosis of enlarged cervical lymph nodes: comparison with conventional B-mode sonography AJR Am J Roentgenol 191 2 2008 604 610
    • (2008) AJR Am J Roentgenol , vol.191 , Issue.2 , pp. 604-610
    • Alam, F.1    Naito, K.2    Horiguchi, J.3
  • 12
    • 69849104105 scopus 로고    scopus 로고
    • The role of sonoelastography in the differential diagnosis of neck nodules
    • L. Rubaltelli, R. Stramare, and A. Tregnaghi The role of sonoelastography in the differential diagnosis of neck nodules J Ultrasound 12 3 2009 93 100
    • (2009) J Ultrasound , vol.12 , Issue.3 , pp. 93-100
    • Rubaltelli, L.1    Stramare, R.2    Tregnaghi, A.3
  • 13
    • 84873484600 scopus 로고    scopus 로고
    • Comparative study of ultrasonic elastography with conventional ultrasonography in cervical lymph nodes [in Chinese]
    • G.H. Shi, X.M. Wang, and G.C. Ou Comparative study of ultrasonic elastography with conventional ultrasonography in cervical lymph nodes [in Chinese] Chin J Ultrasound Med 26 8 2010 730 733
    • (2010) Chin J Ultrasound Med , vol.26 , Issue.8 , pp. 730-733
    • Shi, G.H.1    Wang, X.M.2    Ou, G.C.3
  • 14
    • 69549138066 scopus 로고    scopus 로고
    • The value of ultrasound elastography in differential diagnosis of superficial lymph nodes
    • Y.R. Zhang, Q. Lv, and Y.H. Yin The value of ultrasound elastography in differential diagnosis of superficial lymph nodes Front Med China 3 3 2009 368 374
    • (2009) Front Med China , vol.3 , Issue.3 , pp. 368-374
    • Zhang, Y.R.1    Lv, Q.2    Yin, Y.H.3
  • 15
    • 77952925829 scopus 로고    scopus 로고
    • Ultrasound elastography: Its potential role in assessment of cervical lymphadenopathy
    • R. Tan, Y. Xiao, and Q. He Ultrasound elastography: its potential role in assessment of cervical lymphadenopathy Acad Radiol 17 7 2010 849 855
    • (2010) Acad Radiol , vol.17 , Issue.7 , pp. 849-855
    • Tan, R.1    Xiao, Y.2    He, Q.3
  • 16
    • 79953323273 scopus 로고    scopus 로고
    • Role of sonographic elastography in the differential diagnosis of axillary lymph nodes in breast cancer
    • J.J. Choi, B.J. Kang, and S.H. Kim Role of sonographic elastography in the differential diagnosis of axillary lymph nodes in breast cancer J Ultrasound Med 30 4 2011 429 436
    • (2011) J Ultrasound Med , vol.30 , Issue.4 , pp. 429-436
    • Choi, J.J.1    Kang, B.J.2    Kim, S.H.3
  • 17
    • 80052965629 scopus 로고    scopus 로고
    • Ultrasound elastography as an adjuvant to conventional ultrasound in the preoperative assessment of axillary lymph nodes in suspected breast cancer: A pilot study
    • K. Taylor, S. O'Keeffe, and P.D. Britton Ultrasound elastography as an adjuvant to conventional ultrasound in the preoperative assessment of axillary lymph nodes in suspected breast cancer: a pilot study Clin Radiol 66 11 2011 1064 1071
    • (2011) Clin Radiol , vol.66 , Issue.11 , pp. 1064-1071
    • Taylor, K.1    O'Keeffe, S.2    Britton, P.D.3
  • 18
    • 52049089683 scopus 로고    scopus 로고
    • Freehand real-time elastography: Impact of scanning parameters on image quality and in vitro intra- and interobserver validations
    • R.F. Havre, E. Elde, and O.H. Gilja Freehand real-time elastography: impact of scanning parameters on image quality and in vitro intra- and interobserver validations Ultrasound Med Biol 34 10 2008 1638 1650
    • (2008) Ultrasound Med Biol , vol.34 , Issue.10 , pp. 1638-1650
    • Havre, R.F.1    Elde, E.2    Gilja, O.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.