Volumn 36, Issue 12, 2010, Pages 1990-1997

Real-time qualitative ultrasound elastography of cervical lymph nodes in routine clinical practice: Interobserver agreement and correlation with malignancy

Author keywords

Diagnosis; Elastography; Lymph nodes; Neck; Ultrasound

Indexed keywords

CERVICAL LYMPH NODES; CLINICAL PRACTICES; CUT-OFF; ELASTICITY IMAGING; ELASTOGRAPHY; FINE-NEEDLE ASPIRATIONS; INTEROBSERVER AGREEMENT; LYMPH NODE; LYMPHADENOPATHY; MANN-WHITNEY U TEST; NECK; RECEIVER OPERATING CHARACTERISTIC CURVES; ULTRASOUND; ULTRASOUND ELASTOGRAPHY;

EID: 78449306435     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ultrasmedbio.2010.08.016     Document Type: Article
Times cited : (63)

References (29)
  • 1
    • 0035289918 scopus 로고    scopus 로고
    • Distribution of intranodal vessels in differentiating benign from metastatic neck nodes
    • Ahuja A.T., Ying M., Ho S.S., Metreweli C. Distribution of intranodal vessels in differentiating benign from metastatic neck nodes. Clin Radiol 2001, 56:197-201.
    • (2001) Clin Radiol , vol.56 , pp. 197-201
    • Ahuja, A.T.1    Ying, M.2    Ho, S.S.3    Metreweli, C.4
  • 2
    • 49149112778 scopus 로고    scopus 로고
    • Accuracy of sonographic elastography in the differential diagnosis of enlarged cervical lymph nodes: Comparison with conventional B-mode sonography
    • Alam F., Naito K., Horiguchi J., Fukuda H., Tachikake T., Ito K. Accuracy of sonographic elastography in the differential diagnosis of enlarged cervical lymph nodes: Comparison with conventional B-mode sonography. AJR Am J Roentgenol 2008, 191:604-610.
    • (2008) AJR Am J Roentgenol , vol.191 , pp. 604-610
    • Alam, F.1    Naito, K.2    Horiguchi, J.3    Fukuda, H.4    Tachikake, T.5    Ito, K.6
  • 4
    • 72549106069 scopus 로고    scopus 로고
    • Usefulness of real-time tissue elastography for detecting lymph-node metastases in squamous cell carcinoma
    • Aoyagi S., Izumi K., Hata H., Kawasaki H., Shimizu H. Usefulness of real-time tissue elastography for detecting lymph-node metastases in squamous cell carcinoma. Clin Exp Dermatol 2009, 34:e744-e747.
    • (2009) Clin Exp Dermatol , vol.34
    • Aoyagi, S.1    Izumi, K.2    Hata, H.3    Kawasaki, H.4    Shimizu, H.5
  • 7
    • 34249874877 scopus 로고    scopus 로고
    • Ultrasound thyroid elastography using carotid artery pulsation: preliminary study
    • Bae U., Dighe M., Dubinsky T., Minoshima S., Shamdasani V., Kim Y. Ultrasound thyroid elastography using carotid artery pulsation: preliminary study. J Ultrasound Med 2007, 26:797-805.
    • (2007) J Ultrasound Med , vol.26 , pp. 797-805
    • Bae, U.1    Dighe, M.2    Dubinsky, T.3    Minoshima, S.4    Shamdasani, V.5    Kim, Y.6
  • 8
    • 34247590422 scopus 로고    scopus 로고
    • Ultrasonography of abnormal neck lymph nodes
    • Chan J.M., Shin L.K., Jeffrey R.B. Ultrasonography of abnormal neck lymph nodes. Ultrasound Q 2007, 23:47-54.
    • (2007) Ultrasound Q , vol.23 , pp. 47-54
    • Chan, J.M.1    Shin, L.K.2    Jeffrey, R.B.3
  • 9
    • 37349107460 scopus 로고    scopus 로고
    • Imaging and estimation of tissue elasticity by ultrasound
    • Garra B.S. Imaging and estimation of tissue elasticity by ultrasound. Ultrasound Q 2007, 23:255-268.
    • (2007) Ultrasound Q , vol.23 , pp. 255-268
    • Garra, B.S.1
  • 10
    • 0037361541 scopus 로고    scopus 로고
    • In vivo real-time freehand palpation imaging
    • Hall T.J., Zhu Y., Spalding C.S. In vivo real-time freehand palpation imaging. Ultrasound Med Biol 2003, 29:427-435.
    • (2003) Ultrasound Med Biol , vol.29 , pp. 427-435
    • Hall, T.J.1    Zhu, Y.2    Spalding, C.S.3
  • 11
    • 67649777170 scopus 로고    scopus 로고
    • Real-time ultrasound elastography in the differential diagnosis of benign and malignant thyroid nodules
    • Hong Y., Liu X., Li Z., Zhang X., Chen M., Luo Z. Real-time ultrasound elastography in the differential diagnosis of benign and malignant thyroid nodules. J Ultrasound Med 2009, 28:861-867.
    • (2009) J Ultrasound Med , vol.28 , pp. 861-867
    • Hong, Y.1    Liu, X.2    Li, Z.3    Zhang, X.4    Chen, M.5    Luo, Z.6
  • 13
    • 34248655670 scopus 로고    scopus 로고
    • EUS elastography of the pancreas: Feasibility and pattern description of the normal pancreas, chronic pancreatitis, and focal pancreatic lesions
    • Janssen J., Schlorer E., Greiner L. EUS elastography of the pancreas: Feasibility and pattern description of the normal pancreas, chronic pancreatitis, and focal pancreatic lesions. Gastrointest Endosc 2007, 65:971-978.
    • (2007) Gastrointest Endosc , vol.65 , pp. 971-978
    • Janssen, J.1    Schlorer, E.2    Greiner, L.3
  • 14
    • 0033811492 scopus 로고    scopus 로고
    • Ultrasonography-guided fine-needle aspiration for the assessment of cervical metastases
    • Knappe M., Louw M., Gregor R.T. Ultrasonography-guided fine-needle aspiration for the assessment of cervical metastases. Arch Otolaryngol Head Neck Surg 2000, 126:1091-1096.
    • (2000) Arch Otolaryngol Head Neck Surg , vol.126 , pp. 1091-1096
    • Knappe, M.1    Louw, M.2    Gregor, R.T.3
  • 17
    • 34249302747 scopus 로고    scopus 로고
    • Transient elastography using impulsive ultrasound radiation force: A preliminary comparison with surface palpation elastography
    • Melodelima D., Bamber J.C., Duck F.A., Shipley J.A. Transient elastography using impulsive ultrasound radiation force: A preliminary comparison with surface palpation elastography. Ultrasound Med Biol 2007, 33:959-969.
    • (2007) Ultrasound Med Biol , vol.33 , pp. 959-969
    • Melodelima, D.1    Bamber, J.C.2    Duck, F.A.3    Shipley, J.A.4
  • 18
    • 34547765491 scopus 로고    scopus 로고
    • Elastography: New developments in ultrasound for predicting malignancy in thyroid nodules
    • Rago T., Santini F., Scutari M., Pinchera A., Vitti P. Elastography: New developments in ultrasound for predicting malignancy in thyroid nodules. J Clin Endocrinol Metab 2007, 92:2917-2922.
    • (2007) J Clin Endocrinol Metab , vol.92 , pp. 2917-2922
    • Rago, T.1    Santini, F.2    Scutari, M.3    Pinchera, A.4    Vitti, P.5
  • 21
    • 33846170059 scopus 로고    scopus 로고
    • Analysis of endoscopic ultrasound elastography used for characterisation and differentiation of benign and malignant lymph nodes
    • Saftoiu A., Vilmann P., Hassan H., Gorunescu F. Analysis of endoscopic ultrasound elastography used for characterisation and differentiation of benign and malignant lymph nodes. Ultraschall Med 2006, 27:535-542.
    • (2006) Ultraschall Med , vol.27 , pp. 535-542
    • Saftoiu, A.1    Vilmann, P.2    Hassan, H.3    Gorunescu, F.4
  • 24
    • 33846213605 scopus 로고    scopus 로고
    • Real-time sonoelastography of the cervix: Tissue elasticity of the normal and abnormal cervix
    • Thomas A., Kummel S., Gemeinhardt O., Fischer T. Real-time sonoelastography of the cervix: Tissue elasticity of the normal and abnormal cervix. Acad Radiol 2007, 14:193-200.
    • (2007) Acad Radiol , vol.14 , pp. 193-200
    • Thomas, A.1    Kummel, S.2    Gemeinhardt, O.3    Fischer, T.4
  • 25
    • 0024575944 scopus 로고
    • Ultrasonographic evaluation of cervical lymph node metastases in esophageal cancer with special reference to the relationship between the short to long axis ratio (S/L) and the cancer content
    • Tohnosu N., Onoda S., Isono K. Ultrasonographic evaluation of cervical lymph node metastases in esophageal cancer with special reference to the relationship between the short to long axis ratio (S/L) and the cancer content. J Clin Ultrasound 1989, 17:101-106.
    • (1989) J Clin Ultrasound , vol.17 , pp. 101-106
    • Tohnosu, N.1    Onoda, S.2    Isono, K.3
  • 27
    • 0027879198 scopus 로고
    • In vitro high-resolution ultrasonography of benign and malignant lymph nodes. A sonographic-pathologic correlation
    • Vassallo P., Edel G., Roos N., Naguib A., Peters P.E. In vitro high-resolution ultrasonography of benign and malignant lymph nodes. A sonographic-pathologic correlation. Invest Radiol 1993, 28:698-705.
    • (1993) Invest Radiol , vol.28 , pp. 698-705
    • Vassallo, P.1    Edel, G.2    Roos, N.3    Naguib, A.4    Peters, P.E.5
  • 28
    • 0026507824 scopus 로고
    • Differentiation of benign from malignant superficial lymphadenopathy: The role of high-resolution US
    • Vassallo P., Wernecke K., Roos N., Peters P.E. Differentiation of benign from malignant superficial lymphadenopathy: The role of high-resolution US. Radiology 1992, 183:215-220.
    • (1992) Radiology , vol.183 , pp. 215-220
    • Vassallo, P.1    Wernecke, K.2    Roos, N.3    Peters, P.E.4
  • 29
    • 34249897745 scopus 로고    scopus 로고
    • Comparison of ultrasound elastography, mammography, and sonography in the diagnosis of solid breast lesions
    • Zhi H., Ou B., Luo B.M., Feng X., Wen Y.L., Yang H.Y. Comparison of ultrasound elastography, mammography, and sonography in the diagnosis of solid breast lesions. J Ultrasound Med 2007, 26:807-815.
    • (2007) J Ultrasound Med , vol.26 , pp. 807-815
    • Zhi, H.1    Ou, B.2    Luo, B.M.3    Feng, X.4    Wen, Y.L.5    Yang, H.Y.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.