Volumn 61, Issue 9, 2012, Pages 2374-2383

An electronic system to heat MOX sensors with synchronized and programmable thermal profiles

Author keywords

Metal oxide (MOX) sensors; parasitic capacitance estimation; sensor heater management; synchronous measurement; wide range resistances

Indexed keywords

APPLICATION FIELDS; CARBON MONOXIDE DETECTION; ELECTRONIC SYSTEMS; ENVIRONMENTAL MONITORING; FAST TRANSIENTS; FOOD CONTROL; HOME AUTOMATION; MEASUREMENT CONDITIONS; MEASUREMENT TECHNIQUES; METAL OXIDES; NEW INSTRUMENT; PARASITIC CAPACITANCE; READOUT TIME; RESEARCH ACTIVITIES; SENSOR RESISTANCE; SYNCHRONOUS MEASUREMENTS; THERMAL DYNAMICS; THERMAL PROFILES; WIDE-RANGE RESISTANCES;

EID: 84865258870     PISSN: 00189456     EISSN: None     Source Type: Journal    
DOI: 10.1109/TIM.2012.2199192     Document Type: Article
Times cited : (9)

References (26)
  • 1
    • 84865275414 scopus 로고    scopus 로고
    • 2374-2383
  • 4
    • 0033364719 scopus 로고    scopus 로고
    • Temperature modulation in semiconductor gas sensing
    • DOI 10.1016/S0925-4005(99)00241-5
    • A. P. Lee and B. J. Reedy, "Temperature modulation in semiconductor gas sensing," Sens. Actuators B, Chem., vol. 60, no. 1, pp. 35-42, Nov. 1999. (Pubitemid 30523539)
    • (1999) Sensors and Actuators, B: Chemical , vol.60 , Issue.1 , pp. 35-42
    • Lee, A.P.1    Reedy, B.J.2
  • 6
    • 67349253061 scopus 로고    scopus 로고
    • Model and experimental characterization of dynamic behavior of low-power carbon monoxide MOX sensors operated with pulsed temperature profiles
    • May
    • S. Bicelli, A. Depari, G. Faglia, A. Flammini, A. Fort, M. Mugnaini, A. Ponzoni, V. Vignoli, and S. Rocchi, "Model and experimental characterization of dynamic behavior of low-power carbon monoxide MOX sensors operated with pulsed temperature profiles," IEEE Trans. Instrum. Meas., vol. 58, no. 5, pp. 1324-1332, May 2009.
    • (2009) IEEE Trans. Instrum. Meas. , vol.58 , Issue.5 , pp. 1324-1332
    • Bicelli, S.1    Depari, A.2    Faglia, G.3    Flammini, A.4    Fort, A.5    Mugnaini, M.6    Ponzoni, A.7    Vignoli, V.8    Rocchi, S.9
  • 7
    • 0029309726 scopus 로고
    • 2 sensors: Current status and future prospects
    • May
    • 2 sensors: Current status and future prospects," Sens. Actuators B, Chem., vol. 26/27, no. 1-3, pp. 1-12, May 1995.
    • (1995) Sens. Actuators B, Chem. , vol.26-27 , Issue.1-3 , pp. 1-12
    • Goepel, W.1    Schierbaum, K.D.2
  • 9
    • 0037058578 scopus 로고    scopus 로고
    • 2 using AC impedance spectroscopy
    • DOI 10.1016/S0925-4005(02)00188-0, PII S0925400502001880
    • 2 using AC impedance spectroscopy," Sens. Actuators B, Chem., vol. 87, no. 2, pp. 215-221, Dec. 2002. (Pubitemid 35282266)
    • (2002) Sensors and Actuators, B: Chemical , vol.87 , Issue.2 , pp. 215-221
    • Ling, Z.1    Leach, C.2    Freer, R.3
  • 11
    • 67649971559 scopus 로고    scopus 로고
    • Digital systems architecture to accommodate wide range resistance changes of metal oxide sensors
    • Lecce, Italy, Oct. 26-29
    • U. Frey, M. Graf, S. Taschini, K.-U. Kirstein, and A. Hierlemann, "Digital systems architecture to accommodate wide range resistance changes of metal oxide sensors," in Proc. IEEE Sens., Lecce, Italy, Oct. 26-29, 2008, pp. 593-595.
    • (2008) Proc. IEEE Sens. , pp. 593-595
    • Frey, U.1    Graf, M.2    Taschini, S.3    Kirstein, K.-U.4    Hierlemann, A.5
  • 14
    • 77957743036 scopus 로고    scopus 로고
    • CMOS interfacing for integrated gas sensors: A review
    • Dec.
    • J. W. Gardner, P. K. Guha, F. Udrea, and J. A. Covington, "CMOS interfacing for integrated gas sensors: A review," IEEE Sens. J., vol. 10, no. 12, pp. 1833-1848, Dec. 2010.
    • (2010) IEEE Sens. J. , vol.10 , Issue.12 , pp. 1833-1848
    • Gardner, J.W.1    Guha, P.K.2    Udrea, F.3    Covington, J.A.4
  • 17
    • 79953803407 scopus 로고    scopus 로고
    • A system for the dynamic control and thermal characterization of ultra low power gas sensors
    • May
    • F. Rastrello, P. Placidi, and A. Scorzoni, "A system for the dynamic control and thermal characterization of ultra low power gas sensors," IEEE Trans. Instrum. Meas., vol. 60, no. 5, pp. 1876-1883, May 2011.
    • (2011) IEEE Trans. Instrum. Meas. , vol.60 , Issue.5 , pp. 1876-1883
    • Rastrello, F.1    Placidi, P.2    Scorzoni, A.3
  • 18
    • 77951097978 scopus 로고    scopus 로고
    • A 10 ms-readout interface for the characterization of high-value wide-range experimental resistive sensors
    • Apr.
    • A. Depari, A. Flammini, D. Marioli, E. Sisinni, E. Comini, and A. Ponzoni, "A 10 ms-readout interface for the characterization of high-value wide-range experimental resistive sensors," Sens. Actuators B, Chem., vol. 146, no. 2, pp. 495-501, Apr. 2010.
    • (2010) Sens. Actuators B, Chem. , vol.146 , Issue.2 , pp. 495-501
    • Depari, A.1    Flammini, A.2    Marioli, D.3    Sisinni, E.4    Comini, E.5    Ponzoni, A.6
  • 19
    • 77957839983 scopus 로고    scopus 로고
    • A fast-readout interface circuit for high-value and wide-range resistive chemical sensors
    • Austin, TX, May 3-6
    • A. Depari, A. Flammini, D. Marioli, and E. Sisinni, "A fast-readout interface circuit for high-value and wide-range resistive chemical sensors," in Proc. IEEE I2MTC, Austin, TX, May 3-6, 2010, pp. 116-120.
    • (2010) Proc. IEEE I2MTC , pp. 116-120
    • Depari, A.1    Flammini, A.2    Marioli, D.3    Sisinni, E.4
  • 20
    • 31144446931 scopus 로고    scopus 로고
    • A low-cost circuit for high-value resistive sensors varying over a wide range
    • DOI 10.1088/0957-0233/17/2/016, PII S0957023306974220
    • A. Depari, A. Flammini, D. Marioli, S. Rosa, and A. Taroni, "A low-cost circuit for high-value resistive sensors varying over a wide range," Meas. Sci. Technol., vol. 17, no. 2, pp. 353-358, Feb. 2006. (Pubitemid 43131593)
    • (2006) Measurement Science and Technology , vol.17 , Issue.2 , pp. 353-358
    • Depari, A.1    Flammini, A.2    Marioli, D.3    Rosa, S.4    Taroni, A.5
  • 22
    • 0029309687 scopus 로고
    • AC measurements on tin oxide sensors to improve selectivities and sensitivities
    • Jul.
    • U. Weimar and W. Gopel, "AC measurements on tin oxide sensors to improve selectivities and sensitivities," Sens. Actuators B, Chem., vol. 26, no. 1-3, pp. 13-18, Jul. 1995.
    • (1995) Sens. Actuators B, Chem. , vol.26 , Issue.1-3 , pp. 13-18
    • Weimar, U.1    Gopel, W.2
  • 23
    • 0343289075 scopus 로고    scopus 로고
    • Micromachined metal oxide gas sensors: Opportunities to improve sensor performance
    • DOI 10.1016/S0925-4005(00)00639-0
    • I. Simon, N. Barsan, M. Bauer, and U. Weimar, "Micromachined metal oxide gas sensors: Opportunities to improve sensor performance," Sens. Actuators B, Chem., vol. 73, no. 1, pp. 1-26, Feb. 2001. (Pubitemid 32874436)
    • (2001) Sensors and Actuators, B: Chemical , vol.73 , Issue.1 , pp. 1-26
    • Simon, I.1    Barsan, N.2    Bauer, M.3    Weimar, U.4
  • 24
    • 84867518773 scopus 로고    scopus 로고
    • An electronic system for the thermal management of MOX sensors
    • San Antonio, TX, Feb. 22-24
    • A. Depari, A. Flammini, D. Marioli, E. Sisinni, E. Comini, and A. Ponzoni, "An electronic system for the thermal management of MOX sensors," in Proc SAS, San Antonio, TX, Feb. 22-24, 2011, pp. 292-297.
    • (2011) Proc SAS , pp. 292-297
    • Depari, A.1    Flammini, A.2    Marioli, D.3    Sisinni, E.4    Comini, E.5    Ponzoni, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.