Volumn 56, Issue 5, 2010, Pages 410-416

Hemodynamic responses to continuous versus pulsatile mechanical unloading of the failing left ventricle

Author keywords

[No Author keywords available]

Indexed keywords

AORTIC PRESSURE; AORTIC VALVES; CONTINUOUS FLOWS; DIASTOLIC PRESSURE; ENERGY EQUIVALENT PRESSURES; HEART FAILURE; HEMODYNAMIC ENERGY; HEMODYNAMIC PARAMETERS; HEMODYNAMIC RESPONSE; LEFT VENTRICLES; LEFT VENTRICULAR; LEFT VENTRICULAR ASSIST DEVICES; MECHANICAL CIRCULATORY SUPPORT; PULSE PRESSURE; REPEATED MEASURES; SURPLUS HEMODYNAMIC ENERGIES; SYSTOLIC PRESSURE; T-TESTS;

EID: 77956394931     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/MAT.0b013e3181e7bf3c     Document Type: Article
Times cited : (66)

References (37)
  • 1
    • 0032547931 scopus 로고    scopus 로고
    • Implantable left ventricular assist devices
    • Goldstein DJ, Oz MC, Rose EA: Implantable left ventricular assist devices. N Engl J Med 339: 1522-1533, 1998.
    • (1998) N Engl J Med , vol.339 , pp. 1522-1533
    • Goldstein, D.J.1    Oz, M.C.2    Rose, E.A.3
  • 2
    • 0035892018 scopus 로고    scopus 로고
    • Long-term mechanical left ventricular assistance for end-stage heart failure
    • Rose EA, Gelijns AC, Moskowitz AJ, et al: Long-term mechanical left ventricular assistance for end-stage heart failure. N Engl J Med 345: 1435-1443, 2001.
    • (2001) N Engl J Med , vol.345 , pp. 1435-1443
    • Rose, E.A.1    Gelijns, A.C.2    Moskowitz, A.J.3
  • 3
    • 73349129701 scopus 로고    scopus 로고
    • Advanced heart failure treated with continuous-flow left ventricular assist device
    • Slaughter MS, Rogers JG, Milano CA, et al: Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med 361: 2241-2251, 2009.
    • (2009) N Engl J Med , vol.361 , pp. 2241-2251
    • Slaughter, M.S.1    Rogers, J.G.2    Milano, C.A.3
  • 4
    • 1642409474 scopus 로고    scopus 로고
    • The role of bridge to transplantation: Should LVAD patients be transplanted?
    • Birks EJ, Yacoub MH, Banner NR, et al: The role of bridge to transplantation: Should LVAD patients be transplanted? Curr Opin Cardiol 19: 148-153, 2004.
    • (2004) Curr Opin Cardiol , vol.19 , pp. 148-153
    • Birks, E.J.1    Yacoub, M.H.2    Banner, N.R.3
  • 5
    • 0032727086 scopus 로고    scopus 로고
    • Left ventricular assist system as a bridge to myocardial recovery
    • Frazier OH, Myers TJ: Left ventricular assist system as a bridge to myocardial recovery. Ann Thorac Surg 68: 734-741, 1999.
    • (1999) Ann Thorac Surg , vol.68 , pp. 734-741
    • Frazier, O.H.1    Myers, T.J.2
  • 6
    • 33750500333 scopus 로고    scopus 로고
    • Left ventricular assist device and drug therapy for the reversal of heart failure
    • Birks EJ, Tansley PD, Hardy J, et al: Left ventricular assist device and drug therapy for the reversal of heart failure. N Engl J Med 355: 1873-1884, 2006.
    • (2006) N Engl J Med , vol.355 , pp. 1873-1884
    • Birks, E.J.1    Tansley, P.D.2    Hardy, J.3
  • 7
    • 33645903552 scopus 로고    scopus 로고
    • Mechanical devices and US Food and Drug Adminis-tration (FDA) approval
    • Reitz BA: Mechanical devices and US Food and Drug Adminis-tration (FDA) approval. Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu 123-127, 2006.
    • (2006) Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu , pp. 123-127
    • Reitz, B.A.1
  • 9
    • 33646242043 scopus 로고    scopus 로고
    • Progress of rotary blood pumps
    • Takatani S: Progress of rotary blood pumps. Artif Organs 30: 317-321, 2006.
    • (2006) Artif Organs , vol.30 , pp. 317-321
    • Takatani, S.1
  • 10
    • 34547477618 scopus 로고    scopus 로고
    • Comparison of perfusion modes on microcircula-tion during acute and chronic cardiac support: Is there a difference?
    • Ji B, Undar A: Comparison of perfusion modes on microcircula-tion during acute and chronic cardiac support: Is there a difference? Perfusion 22: 115-119, 2007.
    • (2007) Perfusion , vol.22 , pp. 115-119
    • Ji, B.1    Undar, A.2
  • 11
    • 4544295738 scopus 로고    scopus 로고
    • Left ventricular and myocardial perfusion responses to volume unloading and after load reduction in a computer simulation
    • Giridharan GA, Ewert DL, Pantalos GM, et al: Left ventricular and myocardial perfusion responses to volume unloading and after load reduction in a computer simulation. ASAIO J 50: 512-518, 2004.
    • (2004) ASAIO J , vol.50 , pp. 512-518
    • Giridharan, G.A.1    Ewert, D.L.2    Pantalos, G.M.3
  • 12
    • 0346059626 scopus 로고    scopus 로고
    • Hemodynamic and pressure-volume responses to continuous and pulsatile ventricular assist in an adult mock circulation
    • Koenig SC, Pantalos GM, Gillars KJ, et al: Hemodynamic and pressure-volume responses to continuous and pulsatile ventricular assist in an adult mock circulation. ASAIO J 50: 15-24, 2004.
    • (2004) ASAIO J , vol.50 , pp. 15-24
    • Koenig, S.C.1    Pantalos, G.M.2    Gillars, K.J.3
  • 13
    • 57049090050 scopus 로고    scopus 로고
    • Human, bovine and porcine systematic vascular input impedances are not equivalent: Implications for device testing and xenotransplanta-tion in heart failure
    • Koenig SC, Giridharan GA, Ewart DL, et al: Human, bovine and porcine systematic vascular input impedances are not equivalent: Implications for device testing and xenotransplanta-tion in heart failure. J Heart Lung Transplant 27: 1340-1347, 2008.
    • (2008) J Heart Lung Transplant , vol.27 , pp. 1340-1347
    • Koenig, S.C.1    Giridharan, G.A.2    Ewart, D.L.3
  • 14
    • 34249014596 scopus 로고    scopus 로고
    • Effect of continuous and pulsatile flow left ventricular assist on pulsatility in a pe-diatric animal model of left ventricular dysfunction: Pilot observations
    • Pantalos GM, Giridharan G, Colyer J, et al: Effect of continuous and pulsatile flow left ventricular assist on pulsatility in a pe-diatric animal model of left ventricular dysfunction: Pilot observations. ASAIO J 53: 385-391, 2007.
    • (2007) ASAIO J , vol.53 , pp. 385-391
    • Pantalos, G.M.1    Giridharan, G.2    Colyer, J.3
  • 15
    • 33846390671 scopus 로고    scopus 로고
    • Vascular pulsatility in patients with a pulsatile-or continuous-flow ventricular assist device
    • Travis AR, Giridharan GA, Pantalos GM, et al: Vascular pulsatility in patients with a pulsatile-or continuous-flow ventricular assist device. J Thorac Cardiovasc Surg 133: 517-524, 2007.
    • (2007) J Thorac Cardiovasc Surg , vol.133 , pp. 517-524
    • Travis, A.R.1    Giridharan, G.A.2    Pantalos, G.M.3
  • 16
    • 21244503142 scopus 로고    scopus 로고
    • Monensin toxicosis in the domestic bovine calf: A large animal model of cardiac dysfunction
    • Litwak KN, McMahan A, Lott KA, et al: Monensin toxicosis in the domestic bovine calf: A large animal model of cardiac dysfunction. Contemp Top Lab Anim Sci 44: 45-49, 2005.
    • (2005) Contemp Top Lab Anim Sci , vol.44 , pp. 45-49
    • Litwak, K.N.1    McMahan, A.2    Lott, K.A.3
  • 17
    • 0023006851 scopus 로고
    • Adriamycin cardio-myopathy: Pathological and membrane functional changes in a canine model with mild impairment of left ventricular function
    • Tomlinson CW, McGrath GM, McNeill JH: Adriamycin cardio-myopathy: Pathological and membrane functional changes in a canine model with mild impairment of left ventricular function. Can J Cardiol 2: 368-374, 1986.
    • (1986) Can J Cardiol , vol.2 , pp. 368-374
    • Tomlinson, C.W.1    McGrath, G.M.2    McNeill, J.H.3
  • 18
    • 0025865760 scopus 로고
    • A canine model of chronic heart failure produced by multiple sequential coronary micro-embolizations
    • Sabbah HN, Stein PD, Kono T, et al: A canine model of chronic heart failure produced by multiple sequential coronary micro-embolizations. Am J Physiol 260: H1379-H1384, 1991.
    • (1991) Am J Physiol , vol.260
    • Sabbah, H.N.1    Stein, P.D.2    Kono, T.3
  • 19
    • 77954350611 scopus 로고    scopus 로고
    • A novel subcutane-ous counterpulsation device: Acute hemodynamic responses to pharmacologically-induced hypertension, hypotension, and heart failure
    • (in press)
    • Bartoli CR, Wilson GC, Giridharan GA, et al: A novel subcutane-ous counterpulsation device: Acute hemodynamic responses to pharmacologically- induced hypertension, hypotension, and heart failure. Artif Organs 2010 (in press).
    • (2010) Artif Organs
    • Bartoli, C.R.1    Wilson, G.C.2    Giridharan, G.A.3
  • 20
    • 2442704269 scopus 로고    scopus 로고
    • Integrated data acquisition system for medical device testing and physiology research in compliance with good laboratory practices
    • Koenig SC, Woolard C, Drew G, et al: Integrated data acquisition system for medical device testing and physiology research in compliance with good laboratory practices. Biomed Instrum Technol 38: 229-240, 2004.
    • (2004) Biomed Instrum Technol , vol.38 , pp. 229-240
    • Koenig, S.C.1    Woolard, C.2    Drew, G.3
  • 21
    • 0020024492 scopus 로고
    • Work as a correlate of canine left ventricular oxygen consumption, and the problem of catecholamine oxygen wasting
    • Rooke GA, Feigl EO: Work as a correlate of canine left ventricular oxygen consumption, and the problem of catecholamine oxygen wasting. Circ Res 50: 273-286, 1982.
    • (1982) Circ Res , vol.50 , pp. 273-286
    • Rooke, G.A.1    Feigl, E.O.2
  • 22
    • 2442599564 scopus 로고    scopus 로고
    • HEART: An automated beat-to-beat cardiovascular analysis package using Matlab
    • Schroeder MJ, Perreault B, Ewert DL, Koenig SC: HEART: An automated beat-to-beat cardiovascular analysis package using Matlab. Comput Biol Med 34: 371-388, 2004.
    • (2004) Comput Biol Med , vol.34 , pp. 371-388
    • Schroeder, M.J.1    Perreault, B.2    Ewert, D.L.3    Koenig, S.C.4
  • 23
    • 33847357357 scopus 로고    scopus 로고
    • Molecular basis of the effects of mechan-ical stretch on vascular smooth muscle cells
    • Haga JH, Li YS, Chien S: Molecular basis of the effects of mechan-ical stretch on vascular smooth muscle cells. J Biomech 40: 947-960, 2007.
    • (2007) J Biomech , vol.40 , pp. 947-960
    • Haga, J.H.1    Li, Y.S.2    Chien, S.3
  • 24
    • 0023815639 scopus 로고
    • Cardiac disuse atrophy during LVAD pumping
    • Kinoshita M, Takano H, Taenaka Y, et al: Cardiac disuse atrophy during LVAD pumping. ASAIO Trans 34: 208-212, 1988.
    • (1988) ASAIO Trans , vol.34 , pp. 208-212
    • Kinoshita, M.1    Takano, H.2    Taenaka, Y.3
  • 25
    • 0030022732 scopus 로고    scopus 로고
    • Influence of prolonged ventricular assistance on myocardial histopathology in intact heart
    • Kinoshita M, Takano H, Takaichi S, et al: Influence of prolonged ventricular assistance on myocardial histopathology in intact heart. Ann Thorac Surg 61: 640-645, 1996.
    • (1996) Ann Thorac Surg , vol.61 , pp. 640-645
    • Kinoshita, M.1    Takano, H.2    Takaichi, S.3
  • 26
    • 84931012864 scopus 로고
    • Effects of graded pulsatile pressure on the reflex vasomotor responses elicited by changes of mean pressure in the perfused carotid sinus-aortic arch regions of the dog
    • Angell James JE, Daly Mde B: Effects of graded pulsatile pressure on the reflex vasomotor responses elicited by changes of mean pressure in the perfused carotid sinus-aortic arch regions of the dog. J Physiol 214: 51-64, 1971.
    • (1971) J Physiol , vol.214 , pp. 51-64
    • Angell James, J.E.1    Daly Mde, B.2
  • 27
    • 14444268039 scopus 로고    scopus 로고
    • Prolonged nonpulsatile left heart bypass with reduced systemic pulse pressure causes morphological changes in the aortic wall
    • Nishimura T, Tatsumi E, Takaichi S, et al: Prolonged nonpulsatile left heart bypass with reduced systemic pulse pressure causes morphological changes in the aortic wall. Artif Organs 22: 405-410, 1998.
    • (1998) Artif Organs , vol.22 , pp. 405-410
    • Nishimura, T.1    Tatsumi, E.2    Takaichi, S.3
  • 30
    • 74249110561 scopus 로고    scopus 로고
    • European results with a continuous-flow ventricular assist device for advanced heart-failure patients
    • Lahpor J, Khaghani A, Hetzer R, et al: European results with a continuous-flow ventricular assist device for advanced heart-failure patients. Eur J Cardiothorac Surg 37: 357-361, 2010.
    • (2010) Eur J Cardiothorac Surg , vol.37 , pp. 357-361
    • Lahpor, J.1    Khaghani, A.2    Hetzer, R.3
  • 31
    • 66149135264 scopus 로고    scopus 로고
    • Severely impaired von Willebrand factor-dependent platelet aggregation in patients with a continuous-flow left ventricular assist device (HeartMate II)
    • Klovaite J, Gustafsson F, Mortensen SA, et al: Severely impaired von Willebrand factor-dependent platelet aggregation in patients with a continuous-flow left ventricular assist device (HeartMate II). J Am Coll Cardiol 53: 2162-2167, 2009.
    • (2009) J Am Coll Cardiol , vol.53 , pp. 2162-2167
    • Klovaite, J.1    Gustafsson, F.2    Mortensen, S.A.3
  • 32
    • 40649123746 scopus 로고    scopus 로고
    • Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand disease
    • Geisen U, Heilmann C, Beyersdorf F, et al: Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand disease. Eur J Cardiothorac Surg 33: 679-684, 2008.
    • (2008) Eur J Cardiothorac Surg , vol.33 , pp. 679-684
    • Geisen, U.1    Heilmann, C.2    Beyersdorf, F.3
  • 33
    • 34748926436 scopus 로고    scopus 로고
    • Hemodynamic and exercise performance with pulsatile and continuous-flow left ventricular assist devices
    • Haft J, Armstrong W, Dyke DB, et al: Hemodynamic and exercise performance with pulsatile and continuous-flow left ventricular assist devices. Circulation 116(suppl 11): I8-I15, 2007.
    • (2007) Circulation , vol.116 , Issue.SUPPL. 11
    • Haft, J.1    Armstrong, W.2    Dyke, D.B.3
  • 34
    • 58249093243 scopus 로고    scopus 로고
    • Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices
    • Crow S, John R, Boyle A, et al: Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices. J Thorac Cardiovasc Surg 137: 208-215, 2009.
    • (2009) J Thorac Cardiovasc Surg , vol.137 , pp. 208-215
    • Crow, S.1    John, R.2    Boyle, A.3
  • 35
    • 13844250349 scopus 로고    scopus 로고
    • Pathology in patients with ventricular assist devices: A study of 21 autopsies, 24 ventricular apical core biopsies and 24 explanted hearts
    • Rose AG, Park SJ: Pathology in patients with ventricular assist devices: A study of 21 autopsies, 24 ventricular apical core biopsies and 24 explanted hearts. Cardiovasc Pathol 14: 19-23, 2005.
    • (2005) Cardiovasc Pathol , vol.14 , pp. 19-23
    • Rose, A.G.1    Park, S.J.2
  • 36
    • 33645743807 scopus 로고    scopus 로고
    • Modeling ventricular function during cardiac assist: Does time-varying elastance work?
    • Vandenberghe S, Segers P, Steendijk P, et al: Modeling ventricular function during cardiac assist: Does time-varying elastance work? ASAIO J 52: 4-8, 2006.
    • (2006) ASAIO J , vol.52 , pp. 4-8
    • Vandenberghe, S.1    Segers, P.2    Steendijk, P.3
  • 37
    • 58149231147 scopus 로고    scopus 로고
    • Intraoperative eval-uation of the HeartMate II flow estimator
    • Slaughter MS, Bartoli CR, Sobieski MA, et al: Intraoperative eval-uation of the HeartMate II flow estimator. J Heart Lung Transpl 28: 39-43, 2009.
    • (2009) J Heart Lung Transpl , vol.28 , pp. 39-43
    • Slaughter, M.S.1    Bartoli, C.R.2    Sobieski, M.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.