메뉴 건너뛰기




Volumn 40, Issue 8, 2012, Pages 2002-2008

Transient earth voltage measurement in PD detection of artificial defect models in SF 6

Author keywords

Gas insulation switchgear (GIS); insulation defect; insulation diagnosis; partial discharge (PD); transient Earth voltage measurement (TEVM)

Indexed keywords

ARTIFICIAL DEFECTS; FREQUENCY DISTRIBUTIONS; GAS INSULATION SWITCHGEAR; HIGH VOLTAGE; IMPULSE VOLTAGE; INSULATION DEFECTS; INSULATION DIAGNOSIS; MEASUREMENT SENSITIVITY; METAL PARTICLE; NEEDLE-PLANE; PARTIAL DISCHARGE DETECTION; PD PATTERN; PHASE DISTRIBUTION; PULSE NUMBER; RELATIVE AMPLITUDE; TEST OBJECT; VOLTAGE SENSOR;

EID: 84865213424     PISSN: 00933813     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPS.2012.2199135     Document Type: Article
Times cited : (37)

References (13)
  • 1
    • 84865227728 scopus 로고    scopus 로고
    • 2002-2008
  • 4
    • 58149129376 scopus 로고    scopus 로고
    • Partial discharge measurements in the ultra high frequency (UHF) range
    • Dec.
    • S. Tenbohlen, D. Denissov, S. Hoek, and S. M. Markalous, "Partial discharge measurements in the ultra high frequency (UHF) range," IEEE Trans. Dielectr. Elect. Insul., vol. 15, no. 6, pp. 1544-1552, Dec. 2008.
    • (2008) IEEE Trans. Dielectr. Elect. Insul. , vol.15 , Issue.6 , pp. 1544-1552
    • Tenbohlen, S.1    Denissov, D.2    Hoek, S.3    Markalous, S.M.4
  • 5
    • 0027804011 scopus 로고
    • A partial discharge monitor for the measurement of partial discharges in a high voltage plant by the transient earth voltage technique
    • Canterbury, U.K., Sep.
    • E. Jennings and A. Collinson, "A partial discharge monitor for the measurement of partial discharges in a high voltage plant by the transient earth voltage technique," in Proc. IEEE Int. Conf. Partial Discharge, Canterbury, U.K., Sep. 1993, pp. 90-91.
    • (1993) Proc. IEEE Int. Conf. Partial Discharge , pp. 90-91
    • Jennings, E.1    Collinson, A.2
  • 6
    • 0025502877 scopus 로고
    • Acoustic diagnosis of gas insulated substations: A theoretical and experimental basis
    • Oct.
    • L. E. Lundgaard, M. Runde, and B. Skyberg, "Acoustic diagnosis of gas insulated substations: A theoretical and experimental basis," IEEE Trans. Power Del., vol. 5, no. 4, pp. 1751-1759, Oct. 1990.
    • (1990) IEEE Trans. Power Del. , vol.5 , Issue.4 , pp. 1751-1759
    • Lundgaard, L.E.1    Runde, M.2    Skyberg, B.3
  • 7
    • 78649665473 scopus 로고    scopus 로고
    • Benefits and experiences of non-intrusive partial discharge measurements on MV switchgear
    • Vienna, Austria Paper 0475
    • N. Davies, J. C. Y. Tang, and P. Shiel, "Benefits and experiences of non-intrusive partial discharge measurements on MV switchgear," in Proc. CIRED 19th Int. Conf. Elect. Distrib., Vienna, Austria, 2007, p. Paper 0475.
    • (2007) Proc. CIRED 19th Int. Conf. Elect. Distrib.
    • Davies, N.1    Tang, J.C.Y.2    Shiel, P.3
  • 8
    • 0022917072 scopus 로고
    • 6 mixtures under positive impulse conditions: I. corona development
    • 6 mixtures under positive impulse conditions: I. Corona development," J. Phys. D, Appl. Phys., vol. 19, no. 12, pp. 2351-2361, Dec. 1986. (Pubitemid 17495914)
    • (1986) Journal of Physics D: Applied Physics , vol.19 , Issue.12 , pp. 2351-2361
    • Gallimberti, I.1    Wiegart, N.2
  • 9
    • 0026618713 scopus 로고
    • Partial discharge-X: PD in gas-insulated substations-Measurement and practical considerations
    • DOI 10.1109/57.120634
    • R. Baumgartner, "Partial discharge-part X: PD in gas-insulated substations-measurement and practical considerations," IEEE Elect. Insul. Mag., vol. 8, no. 1, pp. 16-27, Jan./Feb. 1992. (Pubitemid 23563779)
    • (1992) IEEE Electrical Insulation Magazine , vol.8 , Issue.1 , pp. 16-27
    • Baumgartner, R.1    Fruth, B.2    Lanz, W.3    Pettersson, K.4
  • 10
    • 84988765378 scopus 로고
    • Frequency component of current pulse waveform in partial discharge measurement
    • Graz, Austria
    • H. Okubo, A. Suzuki, T. Kato, N. Hayakawa et al., "Frequency component of current pulse waveform in partial discharge measurement," in Proc. 9th Int. Conf. High Voltage Eng., Graz, Austria, 1995, p. 5634.
    • (1995) Proc. 9th Int. Conf. High Voltage Eng. , pp. 5634
    • Okubo, H.1    Suzuki, A.2    Kato, T.3    Hayakawa, N.4
  • 11
    • 79951927040 scopus 로고    scopus 로고
    • Partial discharge characteristics and mechanism in voids under impulse voltage
    • Mar.
    • X. F. Zhao, X. Yao, Z. F. Guo, Y. Y. Wang, J. H. Li, and Y. M. Li, "Partial discharge characteristics and mechanism in voids under impulse voltage," Meas. Sci. Technol., vol. 22, no. 3, pp. 35704-35710, Mar. 2011.
    • (2011) Meas. Sci. Technol. , vol.22 , Issue.3 , pp. 35704-35710
    • Zhao, X.F.1    Yao, X.2    Guo, Z.F.3    Wang, Y.Y.4    Li, J.H.5    Li, Y.M.6
  • 13
    • 0003233471 scopus 로고    scopus 로고
    • Insulation coordination of GIS: Return of experience, on site tests and diagnostic techniques
    • Feb.
    • "Insulation coordination of GIS: Return of experience, on site tests and diagnostic techniques," Electra, no. 176, pp. 67-97, Feb. 1998.
    • (1998) Electra , Issue.176 , pp. 67-97


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.