메뉴 건너뛰기




Volumn 47, Issue 9, 2012, Pages 884-894

Quantification of shape of flow-volume loop of healthy preschool children and preschool children with wheezing disorders

Author keywords

child; maximal expiratory flow volume curve; preschool; reference values; spirometry; wheezing disorders

Indexed keywords

BECLOMETASONE; FLUTICASONE; IPRATROPIUM BROMIDE;

EID: 84865077387     PISSN: 87556863     EISSN: 10990496     Source Type: Journal    
DOI: 10.1002/ppul.22518     Document Type: Article
Times cited : (17)

References (33)
  • 5
    • 0015612569 scopus 로고
    • Analysis of the forced expiratory maneuver
    • Green M, Mead J, Hoppin F, Wohl ME,. Analysis of the forced expiratory maneuver. Chest 1973; 63: 33S-36S.
    • (1973) Chest , vol.63
    • Green, M.1    Mead, J.2    Hoppin, F.3    Wohl, M.E.4
  • 9
    • 46349104622 scopus 로고    scopus 로고
    • Quality control for spirometry in preschool children
    • author reply 107-108
    • Nève V, Matran R, Edme JL,. Quality control for spirometry in preschool children. Am J Respir Crit Care Med 2008; 178: 107; author reply 107-108.
    • (2008) Am J Respir Crit Care Med , vol.178 , pp. 107
    • Nève, V.1    Matran, R.2    Edme, J.L.3
  • 10
    • 0037370048 scopus 로고    scopus 로고
    • Forced expiratory parameters in healthy preschool children (3-6 years of age)
    • Zapletal A, Chalupova J,. Forced expiratory parameters in healthy preschool children (3-6 years of age). Pediatr Pulmonol 2003; 35: 200-207.
    • (2003) Pediatr Pulmonol , vol.35 , pp. 200-207
    • Zapletal, A.1    Chalupova, J.2
  • 14
    • 40649118054 scopus 로고    scopus 로고
    • Correlation of spirometry and symptom scores in childhood asthma and the usefulness of curvature assessment in expiratory flow-volume curves
    • Wildhaber JH, Sznitman J, Harpes P, Straub D, Moller A, Basek P, Sennhauser FH,. Correlation of spirometry and symptom scores in childhood asthma and the usefulness of curvature assessment in expiratory flow-volume curves. Respir Care 2007; 52: 1744-1752.
    • (2007) Respir Care , vol.52 , pp. 1744-1752
    • Wildhaber, J.H.1    Sznitman, J.2    Harpes, P.3    Straub, D.4    Moller, A.5    Basek, P.6    Sennhauser, F.H.7
  • 15
    • 0018242503 scopus 로고
    • Analysis of the configuration of maximum expiratory flow-volume curves
    • Mead J,. Analysis of the configuration of maximum expiratory flow-volume curves. J Appl Physiol 1978; 44: 156-165.
    • (1978) J Appl Physiol , vol.44 , pp. 156-165
    • Mead, J.1
  • 17
    • 0024807073 scopus 로고
    • Changes in maximum expiratory flow-volume curve configuration after treatment with inhaled corticosteroids
    • Kraan J, van der Mark TW, Koeter GH,. Changes in maximum expiratory flow-volume curve configuration after treatment with inhaled corticosteroids. Thorax 1989; 44: 1015-1021.
    • (1989) Thorax , vol.44 , pp. 1015-1021
    • Kraan, J.1    Van Der Mark, T.W.2    Koeter, G.H.3
  • 18
    • 53049096094 scopus 로고    scopus 로고
    • Effects of time, albuterol, and budesonide on the shape of the flow-volume loop in children with asthma
    • for the Childhood Asthma Management Program Research Group
    • Patel AC, Van Natta ML, Tonascia J, Wise RA, Strunk RC, for the Childhood Asthma Management Program Research Group. Effects of time, albuterol, and budesonide on the shape of the flow-volume loop in children with asthma. J Allergy Clin Immunol 2008; 122: 781-787.
    • (2008) J Allergy Clin Immunol , vol.122 , pp. 781-787
    • Patel, A.C.1    Van Natta, M.L.2    Tonascia, J.3    Wise, R.A.4    Strunk, R.C.5
  • 20
    • 24944557936 scopus 로고    scopus 로고
    • The role of computer games in measuring spirometry in healthy and "asthmatic" preschool children
    • Vilozni D, Barak A, Efrati O, Augarten A, Springer C, Yahav Y, Bentur L,. The role of computer games in measuring spirometry in healthy and "asthmatic" preschool children. Chest 2005; 128: 1146-1155.
    • (2005) Chest , vol.128 , pp. 1146-1155
    • Vilozni, D.1    Barak, A.2    Efrati, O.3    Augarten, A.4    Springer, C.5    Yahav, Y.6    Bentur, L.7
  • 21
    • 0037114201 scopus 로고    scopus 로고
    • An interactive computer-animated system (SpiroGame) facilitates spirometry in preschool children
    • Vilozni D, Barker M, Jellouschek H, Heimann G, Blau H,. An interactive computer-animated system (SpiroGame) facilitates spirometry in preschool children. Am J Respir Crit Care Med 2001; 164: 2200-2205.
    • (2001) Am J Respir Crit Care Med , vol.164 , pp. 2200-2205
    • Vilozni, D.1    Barker, M.2    Jellouschek, H.3    Heimann, G.4    Blau, H.5
  • 22
    • 0942287704 scopus 로고    scopus 로고
    • Model of forced expiratory flows and airway geometry in infants
    • Lambert RK, Castile RG, Tepper RS,. Model of forced expiratory flows and airway geometry in infants. J Appl Physiol 2004; 96: 688-692.
    • (2004) J Appl Physiol , vol.96 , pp. 688-692
    • Lambert, R.K.1    Castile, R.G.2    Tepper, R.S.3
  • 23
    • 0014531639 scopus 로고
    • Maximum expiratory flow rates in induced bronchoconstriction in man
    • Bouhuys A, Hunt VR, Kim BM, Zapletal A,. Maximum expiratory flow rates in induced bronchoconstriction in man. J Clin Invest 1969; 48: 1159-1168.
    • (1969) J Clin Invest , vol.48 , pp. 1159-1168
    • Bouhuys, A.1    Hunt, V.R.2    Kim, B.M.3    Zapletal, A.4
  • 24
    • 0015350810 scopus 로고
    • A reduction in maximum mid-expiratory flow rate. A spirographic manifestation of small airway disease
    • McFadden ER, Jr., Linden DA,. A reduction in maximum mid-expiratory flow rate. A spirographic manifestation of small airway disease. Am J Med 1972; 52: 725-737.
    • (1972) Am J Med , vol.52 , pp. 725-737
    • McFadden, Jr.E.R.1    Linden, D.A.2
  • 25
    • 0015860959 scopus 로고
    • Total occlusion of airways producing a restrictive pattern of ventilatory impairment
    • Colp C, Williams MH, Jr., Total occlusion of airways producing a restrictive pattern of ventilatory impairment. Am Rev Respir Dis 1973; 108: 118-122.
    • (1973) Am Rev Respir Dis , vol.108 , pp. 118-122
    • Colp, C.1    Williams, Jr.M.H.2
  • 26
    • 33846146676 scopus 로고    scopus 로고
    • Restrictive impairment in patients with asthma
    • Miller A, Palecki A,. Restrictive impairment in patients with asthma. Respir Med 2007; 101: 272-276.
    • (2007) Respir Med , vol.101 , pp. 272-276
    • Miller, A.1    Palecki, A.2
  • 27
    • 77953335194 scopus 로고    scopus 로고
    • True restrictive ventilatory pattern in asthma
    • Rothe T,. True restrictive ventilatory pattern in asthma. J Asthma 2010; 47: 594-596.
    • (2010) J Asthma , vol.47 , pp. 594-596
    • Rothe, T.1
  • 29
    • 0344084189 scopus 로고    scopus 로고
    • Usefulness of monitoring lung function in asthma
    • Brand PL, Roorda RJ,. Usefulness of monitoring lung function in asthma. Arch Dis Child 2003; 88: 1021-1025.
    • (2003) Arch Dis Child , vol.88 , pp. 1021-1025
    • Brand, P.L.1    Roorda, R.J.2
  • 32
    • 1642570300 scopus 로고    scopus 로고
    • Is forced expiratory volume in one second the best measure of severity in childhood asthma?
    • Spahn JD, Cherniack R, Paull K, Gelfand EW,. Is forced expiratory volume in one second the best measure of severity in childhood asthma? Am J Respir Crit Care Med 2004; 169: 784-786.
    • (2004) Am J Respir Crit Care Med , vol.169 , pp. 784-786
    • Spahn, J.D.1    Cherniack, R.2    Paull, K.3    Gelfand, E.W.4
  • 33
    • 66849138231 scopus 로고    scopus 로고
    • Detection of upper airway obstruction with spirometry results and the flow-volume loop: A comparison of quantitative and visual inspection criteria
    • Modrykamien AM, Gudavalli R, McCarthy K, Liu X, Stoller JK,. Detection of upper airway obstruction with spirometry results and the flow-volume loop: a comparison of quantitative and visual inspection criteria. Respir Care 2009; 54: 474-479.
    • (2009) Respir Care , vol.54 , pp. 474-479
    • Modrykamien, A.M.1    Gudavalli, R.2    McCarthy, K.3    Liu, X.4    Stoller, J.K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.