메뉴 건너뛰기




Volumn 107, Issue 2, 2012, Pages 252-261

The influence of local effects on thermal sensation under non-uniform environmental conditions - Gender differences in thermophysiology, thermal comfort and productivity during convective and radiant cooling

Author keywords

Cooling; Gender differences; Non uniform environmental conditions; Physiology; Productivity; Thermal comfort

Indexed keywords

ADULT; ARTICLE; BODY TEMPERATURE; BODY TEMPERATURE SENSATION; COOLING; ENVIRONMENTAL TEMPERATURE; FEMALE; HUMAN; HUMAN EXPERIMENT; MALE; NORMAL HUMAN; PRIORITY JOURNAL; SEX DIFFERENCE; SKIN TEMPERATURE;

EID: 84865062657     PISSN: 00319384     EISSN: 1873507X     Source Type: Journal    
DOI: 10.1016/j.physbeh.2012.07.008     Document Type: Article
Times cited : (168)

References (51)
  • 1
    • 0004037722 scopus 로고
    • Danish Technical University, Copenhagen
    • Fanger O. Thermal comfort 1970, Danish Technical University, Copenhagen.
    • (1970) Thermal comfort
    • Fanger, O.1
  • 4
    • 43449130890 scopus 로고    scopus 로고
    • Forty years of Fanger's model of thermal comfort: comfort for all?
    • van Hoof J. Forty years of Fanger's model of thermal comfort: comfort for all?. Indoor Air 2008, 18:182-201.
    • (2008) Indoor Air , vol.18 , pp. 182-201
    • van Hoof, J.1
  • 5
    • 0034289249 scopus 로고    scopus 로고
    • A standard for natural ventilation
    • Brager G.S., de Dear R. A standard for natural ventilation. Ashrae J 2000, 42:21-28.
    • (2000) Ashrae J , vol.42 , pp. 21-28
    • Brager, G.S.1    de Dear, R.2
  • 6
    • 0036642994 scopus 로고    scopus 로고
    • The validity of ISO-PMV for predicting comfort votes in every-day thermal environments
    • Humphreys M.A., Nicol J.F. The validity of ISO-PMV for predicting comfort votes in every-day thermal environments. Energy Build 2002, 34:667-684.
    • (2002) Energy Build , vol.34 , pp. 667-684
    • Humphreys, M.A.1    Nicol, J.F.2
  • 9
    • 84860861128 scopus 로고    scopus 로고
    • The thermoneutral zone: implications for metabolic studies
    • Kingma B., Frijns A., Van Marken Lichtenbelt W. The thermoneutral zone: implications for metabolic studies. Front Biosci 2012, E4:1975-1985.
    • (2012) Front Biosci , vol.E4 , pp. 1975-1985
    • Kingma, B.1    Frijns, A.2    Van Marken Lichtenbelt, W.3
  • 10
    • 84858151538 scopus 로고    scopus 로고
    • Thermal comfort and gender: a literature review
    • Karjalainen S. Thermal comfort and gender: a literature review. Indoor Air 2011, 22(2):96-109.
    • (2011) Indoor Air , vol.22 , Issue.2 , pp. 96-109
    • Karjalainen, S.1
  • 13
    • 77951091557 scopus 로고    scopus 로고
    • Gender differences in thermal comfort and mental performance at different vertical air temperatures
    • Hashiguchi N., Feng Y., Tochihara Y. Gender differences in thermal comfort and mental performance at different vertical air temperatures. Eur J Appl Physiol 2010, 109:41-48.
    • (2010) Eur J Appl Physiol , vol.109 , pp. 41-48
    • Hashiguchi, N.1    Feng, Y.2    Tochihara, Y.3
  • 14
    • 20844444925 scopus 로고    scopus 로고
    • International standards for the indoor environment
    • Olesen B.W. International standards for the indoor environment. Indoor Air 2004, 14:18-26.
    • (2004) Indoor Air , vol.14 , pp. 18-26
    • Olesen, B.W.1
  • 15
    • 32344433039 scopus 로고    scopus 로고
    • Partial- and whole-body thermal sensation and comfort - part II: non-uniform environmental conditions
    • Arens E., Zhang H., Huizenga C. Partial- and whole-body thermal sensation and comfort - part II: non-uniform environmental conditions. J Therm Biol 2006, 31:60-66.
    • (2006) J Therm Biol , vol.31 , pp. 60-66
    • Arens, E.1    Zhang, H.2    Huizenga, C.3
  • 16
    • 70350163024 scopus 로고    scopus 로고
    • Thermal sensation and comfort models for non-uniform and transient environments: part I: local sensation of individual body parts
    • Zhang H., Arens E., Huizenga C., Han T. Thermal sensation and comfort models for non-uniform and transient environments: part I: local sensation of individual body parts. Build Environ 2010, 45:380-388.
    • (2010) Build Environ , vol.45 , pp. 380-388
    • Zhang, H.1    Arens, E.2    Huizenga, C.3    Han, T.4
  • 17
    • 27744548574 scopus 로고    scopus 로고
    • Passive cooling in a low-energy office building
    • Breesch H., Bossaer A., Janssens A. Passive cooling in a low-energy office building. Sol Energy 2005, 79:682-696.
    • (2005) Sol Energy , vol.79 , pp. 682-696
    • Breesch, H.1    Bossaer, A.2    Janssens, A.3
  • 18
    • 33751538902 scopus 로고    scopus 로고
    • Gender differences in thermal comfort and use of thermostats in everyday thermal environments
    • Karjalainen S. Gender differences in thermal comfort and use of thermostats in everyday thermal environments. Build Environ 2007, 42:1594-1603.
    • (2007) Build Environ , vol.42 , pp. 1594-1603
    • Karjalainen, S.1
  • 19
    • 45549101819 scopus 로고    scopus 로고
    • Investigation of gender difference in thermal comfort for Chinese people
    • Lan L., Lian Z., Liu W., Liu Y. Investigation of gender difference in thermal comfort for Chinese people. Eur J Appl Physiol 2008, 102:471-480.
    • (2008) Eur J Appl Physiol , vol.102 , pp. 471-480
    • Lan, L.1    Lian, Z.2    Liu, W.3    Liu, Y.4
  • 20
    • 77952997853 scopus 로고    scopus 로고
    • Thermal discomfort with cold extremities in relation to age, gender, and body mass index in a random sample of a Swiss urban population
    • Mozaffarieh M., Fontana Gasio P., Schotzau A., Orgul S., Flammer J., Krauchi K. Thermal discomfort with cold extremities in relation to age, gender, and body mass index in a random sample of a Swiss urban population. Popul Health Metrics 2010, 8:17-22.
    • (2010) Popul Health Metrics , vol.8 , pp. 17-22
    • Mozaffarieh, M.1    Fontana Gasio, P.2    Schotzau, A.3    Orgul, S.4    Flammer, J.5    Krauchi, K.6
  • 22
    • 0034874811 scopus 로고    scopus 로고
    • Oral contraceptives alter sleep and raise body temperature in young women
    • Baker F.C., Mitchell D., Driver H.S. Oral contraceptives alter sleep and raise body temperature in young women. Pflugers Arch 2001, 442:729-737.
    • (2001) Pflugers Arch , vol.442 , pp. 729-737
    • Baker, F.C.1    Mitchell, D.2    Driver, H.S.3
  • 23
    • 0014115757 scopus 로고
    • The assessment of the amount of fat in the human body from measurements of skinfold thickness
    • Durnin J.V., Rahaman M.M. The assessment of the amount of fat in the human body from measurements of skinfold thickness. Br J Nutr 1967, 21:681-689.
    • (1967) Br J Nutr , vol.21 , pp. 681-689
    • Durnin, J.V.1    Rahaman, M.M.2
  • 26
    • 0001247871 scopus 로고
    • A database for determining the evaporative resistance of clothing
    • Mccullough E.A., Jones B.W., Tamura T. A database for determining the evaporative resistance of clothing. ASHRAE Trans 1989, 95:316-328.
    • (1989) ASHRAE Trans , vol.95 , pp. 316-328
    • Mccullough, E.A.1    Jones, B.W.2    Tamura, T.3
  • 27
    • 0028706655 scopus 로고
    • Thermal insulation provided by chairs
    • Mccullough E.A., Olesen B.W., Hong S. Thermal insulation provided by chairs. ASHRAE Trans 1994, 100(1):795-802.
    • (1994) ASHRAE Trans , vol.100 , Issue.1 , pp. 795-802
    • Mccullough, E.A.1    Olesen, B.W.2    Hong, S.3
  • 28
    • 0032635185 scopus 로고    scopus 로고
    • Using large radiant panels for indoor climate conditioning
    • Roulet C.A., Rossy J.P., Roulet Y. Using large radiant panels for indoor climate conditioning. Energy Build 1999, 30:121-126.
    • (1999) Energy Build , vol.30 , pp. 121-126
    • Roulet, C.A.1    Rossy, J.P.2    Roulet, Y.3
  • 29
    • 0036836499 scopus 로고    scopus 로고
    • Radiant ceiling panel heating-cooling systems: experimental and simulated study of the performances, thermal comfort and energy consumptions
    • Miriel J., Serres L., Trombe A. Radiant ceiling panel heating-cooling systems: experimental and simulated study of the performances, thermal comfort and energy consumptions. Appl Therm Eng 2002, 22:1861-1873.
    • (2002) Appl Therm Eng , vol.22 , pp. 1861-1873
    • Miriel, J.1    Serres, L.2    Trombe, A.3
  • 31
    • 1842868595 scopus 로고    scopus 로고
    • Using skin temperature gradients or skin heat flux measurements to determine thresholds of vasoconstriction and vasodilatation
    • House J.R., Tipton M.J. Using skin temperature gradients or skin heat flux measurements to determine thresholds of vasoconstriction and vasodilatation. Eur J Appl Physiol 2002, 88:141-145.
    • (2002) Eur J Appl Physiol , vol.88 , pp. 141-145
    • House, J.R.1    Tipton, M.J.2
  • 32
    • 0037635936 scopus 로고    scopus 로고
    • Skin-temperature gradients are a validated measure of fingertip perfusion
    • [author reply 3-4]
    • Sessler D.I. Skin-temperature gradients are a validated measure of fingertip perfusion. Eur J Appl Physiol 2003, 89:401-402. [author reply 3-4].
    • (2003) Eur J Appl Physiol , vol.89 , pp. 401-402
    • Sessler, D.I.1
  • 38
    • 0032855118 scopus 로고    scopus 로고
    • Visual analogue scales for detecting changes in symptoms of the sick building syndrome in an intervention study
    • Kildeso J., Wyon D., Skov T., Schneider T. Visual analogue scales for detecting changes in symptoms of the sick building syndrome in an intervention study. Scand J Work Environ Health 1999, 25:361-367.
    • (1999) Scand J Work Environ Health , vol.25 , pp. 361-367
    • Kildeso, J.1    Wyon, D.2    Skov, T.3    Schneider, T.4
  • 40
    • 4744367511 scopus 로고    scopus 로고
    • Skin and core temperature response to partial- and whole-body heating and cooling
    • Huizenga C., Zhang H., Arens E., Wang D. Skin and core temperature response to partial- and whole-body heating and cooling. J Therm Biol 2004, 29:549-558.
    • (2004) J Therm Biol , vol.29 , pp. 549-558
    • Huizenga, C.1    Zhang, H.2    Arens, E.3    Wang, D.4
  • 41
    • 0036089772 scopus 로고    scopus 로고
    • Thermal regulation and comfort during a mild-cold exposure in young Japanese women complaining of unusual coldness
    • Nagashima K., Yoda T., Yagishita T., Taniguchi A., Hosono T., Kanosue K. Thermal regulation and comfort during a mild-cold exposure in young Japanese women complaining of unusual coldness. J Appl Physiol 2002, 92:1029-1035.
    • (2002) J Appl Physiol , vol.92 , pp. 1029-1035
    • Nagashima, K.1    Yoda, T.2    Yagishita, T.3    Taniguchi, A.4    Hosono, T.5    Kanosue, K.6
  • 42
    • 57449099066 scopus 로고    scopus 로고
    • Cold extremities and difficulties initiating sleep: evidence of co-morbidity from a random sample of a Swiss urban population
    • Krauchi K., Gasio P.F., Vollenweider S., Von Arb M., Dubler B., Orgul S., et al. Cold extremities and difficulties initiating sleep: evidence of co-morbidity from a random sample of a Swiss urban population. J Sleep Res 2008, 17:420-426.
    • (2008) J Sleep Res , vol.17 , pp. 420-426
    • Krauchi, K.1    Gasio, P.F.2    Vollenweider, S.3    Von Arb, M.4    Dubler, B.5    Orgul, S.6
  • 43
    • 0018642097 scopus 로고
    • Sex-differences in human thermoregulatory response to heat and cold stress
    • Burse R.L. Sex-differences in human thermoregulatory response to heat and cold stress. Hum Factors 1979, 21:687-699.
    • (1979) Hum Factors , vol.21 , pp. 687-699
    • Burse, R.L.1
  • 44
    • 0015792421 scopus 로고
    • Assessment of man's thermal comfort in practice
    • Fanger P.O. Assessment of man's thermal comfort in practice. Br J Ind Med 1973, 30:313-324.
    • (1973) Br J Ind Med , vol.30 , pp. 313-324
    • Fanger, P.O.1
  • 45
    • 76149143729 scopus 로고    scopus 로고
    • Investigation on the impacts of different genders and ages on satisfaction with thermal environments in office buildings
    • Choi J., Aziz A., Loftness V. Investigation on the impacts of different genders and ages on satisfaction with thermal environments in office buildings. Build Environ 2010, 45:1529-1535.
    • (2010) Build Environ , vol.45 , pp. 1529-1535
    • Choi, J.1    Aziz, A.2    Loftness, V.3
  • 46
    • 0034878685 scopus 로고    scopus 로고
    • Thermal comfort and behavioural strategies in office buildings located in a hot-arid climate
    • Cena K., de Dear R. Thermal comfort and behavioural strategies in office buildings located in a hot-arid climate. J Therm Biol 2001, 26:409-414.
    • (2001) J Therm Biol , vol.26 , pp. 409-414
    • Cena, K.1    de Dear, R.2
  • 47
    • 77953130709 scopus 로고    scopus 로고
    • Influence of age on thermal thresholds, thermal pain thresholds, and reaction time
    • Huang H.W., Wang W.C., Lin C.C. Influence of age on thermal thresholds, thermal pain thresholds, and reaction time. J Clin Neurosci 2010, 17:722-726.
    • (2010) J Clin Neurosci , vol.17 , pp. 722-726
    • Huang, H.W.1    Wang, W.C.2    Lin, C.C.3
  • 48
    • 0036730052 scopus 로고    scopus 로고
    • Circadian and age-related modulation of thermoreception and temperature regulation: mechanisms and functional implications
    • Van Someren E.J., Raymann R.J., Scherder E.J., Daanen H.A., Swaab D.F. Circadian and age-related modulation of thermoreception and temperature regulation: mechanisms and functional implications. Ageing Res Rev 2002, 1:721-778.
    • (2002) Ageing Res Rev , vol.1 , pp. 721-778
    • Van Someren, E.J.1    Raymann, R.J.2    Scherder, E.J.3    Daanen, H.A.4    Swaab, D.F.5
  • 49
    • 43449114551 scopus 로고    scopus 로고
    • Thermal comfort and older adults
    • van Hoof J., Hensen J.L.M. Thermal comfort and older adults. Gerontechnology 2006, 4:223-228.
    • (2006) Gerontechnology , vol.4 , pp. 223-228
    • van Hoof, J.1    Hensen, J.L.M.2
  • 50
    • 77955160676 scopus 로고    scopus 로고
    • Differences between young adults and elderly in thermal comfort, productivity, and thermal physiology in response to a moderate temperature drift and a steady-state condition
    • Schellen L., Lichtenbelt W.D.V., Loomans M.G.L.C., Toftum J., de Wit M.H. Differences between young adults and elderly in thermal comfort, productivity, and thermal physiology in response to a moderate temperature drift and a steady-state condition. Indoor Air 2010, 20:273-283.
    • (2010) Indoor Air , vol.20 , pp. 273-283
    • Schellen, L.1    Lichtenbelt, W.D.V.2    Loomans, M.G.L.C.3    Toftum, J.4    de Wit, M.H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.