메뉴 건너뛰기




Volumn 85, Issue 1016, 2012, Pages 1112-1117

Investigating the relationship between virtual cystoscopy image quality and CT slice thickness

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BLADDER CANCER; BLADDER WALL; COMPARATIVE STUDY; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; CYSTOGRAPHY; CYSTOSCOPY; FEMALE; HUMAN; IMAGE QUALITY; IMAGE RECONSTRUCTION; MALE; NOISE; PELVIS RADIOGRAPHY; QUALITATIVE ANALYSIS; RADIOLOGICAL PARAMETERS; SCORING SYSTEM; STANDARD; VIRTUAL CYSTOSCOPY;

EID: 84864834125     PISSN: 00071285     EISSN: None     Source Type: Journal    
DOI: 10.1259/bjr/99567374     Document Type: Article
Times cited : (10)

References (26)
  • 1
    • 0033790953 scopus 로고    scopus 로고
    • Early complications of endoscopic treatment for superficial bladder tumors
    • Collado A, Chechile GE, Salvador J, Vicente J. Early complications of endoscopic treatment for superficial bladder tumors. J Urol 2000;164:1529-32.
    • (2000) J Urol , vol.164 , pp. 1529-1532
    • Collado, A.1    Chechile, G.E.2    Salvador, J.3    Vicente, J.4
  • 2
    • 33645811724 scopus 로고    scopus 로고
    • Risk factors for adverse outcomes after transurethral resection of bladder tumors
    • Hollenbeck BK, Miller DC, Taub D, Dunn RL, Khuri SF, Henderson WG, et al. Risk factors for adverse outcomes after transurethral resection of bladder tumors. Cancer 2006;106:1527-35.
    • (2006) Cancer , vol.106 , pp. 1527-1535
    • Hollenbeck, B.K.1    Miller, D.C.2    Taub, D.3    Dunn, R.L.4    Khuri, S.F.5    Henderson, W.G.6
  • 3
    • 27744458332 scopus 로고    scopus 로고
    • Transurethral bladder tumor resection: Intraoperative and postoperative complications in a residency setting
    • DOI 10.1097/01.ju.0000181797.19395.03
    • Nieder AM, Meinbach DS, Kim SS, Soloway MS. Transurethral bladder tumor resection: intraoperative and postoperative complications in a residency setting. J Urol 2005;174:2307-9. (Pubitemid 41611811)
    • (2005) Journal of Urology , vol.174 , Issue.6 , pp. 2307-2309
    • Nieder, A.M.1    Meinbach, D.S.2    Kim, S.S.3    Soloway, M.S.4
  • 5
    • 27744505810 scopus 로고    scopus 로고
    • Comparison of virtual cystoscopy, multiplanar reformation, and source CT images with contrast material-filled bladder for detecting lesions
    • Kim JK, Park SY, Kim HS, Kim SH, Cho KS. Comparison of virtual cystoscopy, multiplanar reformation, and source CT images with contrast material-filled bladder for detecting lesions. AJR Am J Roentgenol 2005;185:689-96.
    • (2005) AJR Am J Roentgenol , vol.185 , pp. 689-696
    • Kim, J.K.1    Park, S.Y.2    Kim, H.S.3    Kim, S.H.4    Cho, K.S.5
  • 6
    • 10644263598 scopus 로고    scopus 로고
    • CT cystography and virtual cystoscopy in the assessment of new and recurrent bladder neoplasms
    • DOI 10.1016/j.ejrad.2004.02.002, PII S0720048X04000452, Pediatric Intervention and Angiography
    • Browne RF, Murphy SM, Grainger R, Hamilton S. CT cystography and virtual cystoscopy in the assessment of new and recurrent bladder neoplasms. Eur J Radiol 2005;53:147-53. (Pubitemid 39656092)
    • (2005) European Journal of Radiology , vol.53 , Issue.1 , pp. 147-153
    • Browne, R.F.J.1    Murphy, S.M.2    Grainger, R.3    Hamilton, S.4
  • 7
    • 0038756485 scopus 로고    scopus 로고
    • Diagnostic potential of virtual cystoscopy of the bladder: MRI vs CT. Preliminary report
    • Bernhardt TM, Schmidl H, Philipp C, Allhoff EP, Rapp-Bernhardt U. Diagnostic potential of virtual cystoscopy of the bladder: MRI vs CT. Preliminary report. Eur Radiol 2003;13:305-12. (Pubitemid 36798608)
    • (2003) European Radiology , vol.13 , Issue.2 , pp. 305-312
    • Bernhardt, T.M.1    Schmidl, H.2    Philipp, C.3    Allhoff, E.P.4    Rapp-Bernhardt, U.5
  • 10
    • 0030854315 scopus 로고    scopus 로고
    • Virtual cystoscopy: Early clinical experience
    • Fenlon HM, Bell TV, Ahari HK, Hussain S. Virtual cystoscopy: early clinical experience. Radiology 1997;205:272-5. (Pubitemid 27415161)
    • (1997) Radiology , vol.205 , Issue.1 , pp. 272-275
    • Fenlon, H.M.1    Bell, T.V.2    Ahari, H.K.3    Hussain, S.4
  • 11
    • 0030656538 scopus 로고    scopus 로고
    • Thin-section helical computed tomography of the bladder: Initial clinical experience with virtual reality imaging
    • discussion: 689
    • Hussain S, Loeffler JA, Babayan RK, Fenlon HM. Thin-section helical computed tomography of the bladder: initial clinical experience with virtual reality imaging. Urology 1997;50:685-8 (discussion: 689).
    • (1997) Urology , vol.50 , pp. 685-688
    • Hussain, S.1    Loeffler, J.A.2    Babayan, R.K.3    Fenlon, H.M.4
  • 13
    • 0036664625 scopus 로고    scopus 로고
    • CT-virtual endoscopy of the urinary tract
    • Prando A. CT-virtual endoscopy of the urinary tract. Int Braz J Urol 2002;28:317-22. (Pubitemid 36322437)
    • (2002) International Braz J Urol , vol.28 , Issue.4 , pp. 317-322
    • Prando, A.1
  • 15
    • 1642421892 scopus 로고    scopus 로고
    • Virtual cystoscopy in the evaluation of bladder tumors
    • DOI 10.1016/S0899-7071(03)00117-7, PII S0899707103001177
    • Yazgan C, Fitoz S, Atasoy C, Turkolmez K, Yagci C, Akyar S. Virtual cystoscopy in the evaluation of bladder tumors. Clin Imaging 2004;28:138-42. (Pubitemid 38402061)
    • (2004) Clinical Imaging , vol.28 , Issue.2 , pp. 138-142
    • Yazgan, C.1    Fitoz, S.2    Atasoy, C.3    Turkolmez, K.4    Yagci, C.5    Akyar, S.6
  • 17
    • 0345015530 scopus 로고    scopus 로고
    • CT Colonography Data Interpretation: Effect of Different Section Thicknesses-Preliminary Observations
    • DOI 10.1148/radiol.2293021404
    • Lui YW, Macari M, Israel G, Bini EJ, Wang H, Babb J. CT colonography data interpretation: effect of different section thicknesses - preliminary observations. Radiology 2003;229:791-7. (Pubitemid 37467585)
    • (2003) Radiology , vol.229 , Issue.3 , pp. 791-797
    • Lui, Y.W.1    Macari, M.2    Israel, G.3    Bini, E.J.4    Wang, H.5    Babb, J.6
  • 19
  • 21
    • 43049148708 scopus 로고    scopus 로고
    • Contrast-enhanced multislice pneumo-CTcystography in the evaluation of urinary bladder neoplasms
    • Scardapane A, Pagliarulo V, Ianora AA, Pagliarulo A, Angelelli G. Contrast-enhanced multislice pneumo-CTcystography in the evaluation of urinary bladder neoplasms. Eur J Radiol 2007;66:246-52.
    • (2007) Eur J Radiol , vol.66 , pp. 246-252
    • Scardapane, A.1    Pagliarulo, V.2    Ianora, A.A.3    Pagliarulo, A.4    Angelelli, G.5
  • 23
    • 0038005444 scopus 로고    scopus 로고
    • Experimental colonic phantom for the evaluation of the optimal scanning technique for CT colonography using a multidetector spiral CT equipment
    • Laghi A, Iannaccone R, Mangiapane F, Piacentini F, Iori S, Passariello R. Experimental colonic phantom for the evaluation of the optimal scanning technique for CT colonography using a multidetector spiral CT equipment. Eur Radiol 2003;13:459-66. (Pubitemid 36790518)
    • (2003) European Radiology , vol.13 , Issue.3 , pp. 459-466
    • Laghi, A.1    Iannaccone, R.2    Mangiapane, F.3    Piacentini, F.4    Iori, S.5    Passariello, R.6
  • 24
    • 0042431539 scopus 로고    scopus 로고
    • CT colonography: Protocol optimization with multi-detector row CT - Study in an anthropomorphic colon phantom
    • DOI 10.1148/radiol.2283020928
    • Wessling J, Fischbach R, Meier N, Allkemper T, Klusmeier J, Ludwig K, et al. CT colonography: Protocol optimization with multi-detector row CT - study in an anthropomorphic colon phantom. Radiology 2003;228:753-9. (Pubitemid 37025486)
    • (2003) Radiology , vol.228 , Issue.3 , pp. 753-759
    • Wessling, J.1    Fischbach, R.2    Meier, N.3    Allkemper, T.4    Klusmeier, J.5    Ludwig, K.6    Heindel, W.7
  • 25
    • 0348134469 scopus 로고    scopus 로고
    • Optimization of scanning parameters for multi-slice CT colonography: Experiments with synthetic and animal phantoms
    • DOI 10.1016/S0009-9260(03)00297-6
    • Embleton KV, Nicholson DA, Hufton AP, Jackson A. Optimization of scanning parameters for multi-slice CT colonography: experiments with synthetic and animal phantoms. Clin Radiol 2003;58:955-63. (Pubitemid 37527152)
    • (2003) Clinical Radiology , vol.58 , Issue.12 , pp. 955-963
    • Embleton, K.V.1    Nicholson, D.A.2    Hufton, A.P.3    Jackson, A.4
  • 26
    • 33748921885 scopus 로고    scopus 로고
    • Detection of colorectal polyps: Comparison of multi-detector row CT and MR colonography in a colon phantom
    • DOI 10.1148/radiol.2411050292
    • Wessling J, Fischbach R, Borchert A, Kugel H, Allkemper T, Osada N, et al. Detection of colorectal polyps: comparison of multi-detector row CT and MR colonography in a colon phantom. Radiology 2006;241:125-31. (Pubitemid 44433342)
    • (2006) Radiology , vol.241 , Issue.1 , pp. 125-131
    • Wessling, J.1    Fischbach, R.2    Borchert, A.3    Kugel, H.4    Allkemper, T.5    Osada, N.6    Heindel, W.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.